967 resultados para Analog readout
Resumo:
This work aims to investigate more deeply the concept of Newsgame in order to map essencial features for this new type of media product. Based on several examples, we will analyze the different ways in which a game can behave journalistically. We shall seek the author who coined the term “newsgame”, Gonzalo Frasca, and other international authors, based or not on the first, that attempt to point out limits for these electronic games that aspire Journalism. Some models are harsh, while others are more embracing, but all are intended to achieve a new paradigm in communication that releases itself from static representation stemmed from analog media and ventures into the potential of simulation brought from the digital platform. Examples of newsgames and its theories set forth herein also include Brazilian cases, which we will try to prove to be the most laymen on the subject
Resumo:
This monograph proposes the implementation of a low cost PID controller utilizing a PIC microcontroller, and its application in a positioning system previously controlled by a dedicated integrated circuit for a positioning system. Applying the closed-loop PID control, the system instability was reduced, and its response was smoother, eliminating vibrations and mechanical wear compared to its response with the dedicated integrated circuit, which has a very limited control action. The actuator of the system is a DC motor, whose speed is controlled by the Pulse Width Modulation (PWM) technique, using a Full-Bridge circuit, allowing the shift of direction of rotation. The utilized microcontroller was the PIC16F684, which has an enhanced PWM module, with its analog converters used as reference and position feedback. The positioning sensor is a multiturn potentiometer coupled to the motor axis by gears. The possibility of programming the PID coefficients in the microcontroller, as well as the adjustment of the sampling rate, allows the implemented system achieving high level of versatility
Resumo:
The main objective of the presented study is the design of a analog multiplier-divider as integrant part of the type-reducer circuit of type-2 fuzzy controller chip. The proposed circuit is a multiplier/divider which operates in current mode, in the CMOS technology with a supply voltage of 1.8 V.The circuit simulation was performed in PSPICE software with simulation model provided by AMS (Austria Mikro Systems International) in CMOS technology 0.35μm
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Pós-graduação em Comunicação - FAAC
Resumo:
Pós-graduação em Biotecnologia - IQ
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Background: The aim of this study was to determine the perception of smile esthetics among orthodontists and laypeople with respect to the presence of diastemas in the upper lateral incisor in the mesial, distal, and both surfaces using an oblique smile analysis. Methods: Two standardized oblique photos of pleasant smiles from two white women were selected. Images were digitally altered to create diastemas in the lateral incisor, in 0.5-mm increments, in the mesial, distal, or both surfaces. Final images were randomly assembled in a photo album, which was given to 120 judgesd60 orthodontists and 60 laypersons. Each rater was asked to evaluate the attractiveness of the images on a visual analog scale. The data collected were submitted to statistical analysis by the means of one-way ANOVA with the Tukey post hoc test and the unpaired Student’s t test. Results: The most attractive smile was the one without spacing, and the presence of diastemas was considered unattractive by both groups of raters, following a pattern: the greater and the more mesially located, the more unattractive was the smile. Conclusions: The results of this study suggest that diastemas in the upper lateral incisor area were considered unattractive, following a pattern: the greater and the more mesially located, the more unattractive was the smile.
Resumo:
Composite resin is a dental material susceptible to color change over time which limits the longevity of restorations made with this material. The influence of light curing units and different fluoride mouthrinses on superficial morphology and color stability of a nanofilled composite resin was evaluated. Specimens (N = 150) were prepared and polished. The experimental groups were divided according to the type of light source (halogen and LED) and immersion media (artificial saliva, 0.05% sodium fluoride solution-manipulated, Fluordent Reach, Oral B, Fluorgard). Specimens remained in artificial saliva for 24-h baseline. For 60 days, they were immersed in solutions for 1 min. Color readout was taken at baseline and after 60 days of immersion. Surface morphology was analyzed by Scanning Electron Microscopy (SEM) after 60 days of immersion. Color change data were submitted to two-way Analysis of Variance and Tukey tests (α = 0.05). Surface morphology was qualitatively analyzed. The factor light source presented no significant variability (P = 0.281), the immersion media, significant variability (P < 0.001) and interaction between factors, no significant variability (P = 0.050). According to SEM observations, no difference was noted in the surface of the specimens polymerized by different light sources, irrespective of the immersion medium. It was concluded that the light source did not influence the color stability of composite, irrespective of the immersion media, and among the fluoride solutions analyzed, Fluorgard was the one that promoted the greatest color change, however, this was not clinically perceptible. The immersion media did not influence the morphology of the studied resin. Microsc. Res. Tech. 77:941–946, 2014. © 2014 Wiley Periodicals, Inc.
Resumo:
Purpose: Angiogenesis involves many mediators including integrins, and the tripeptide RGD is a target amino acid recognition sequence for many of them. Hindlimb ischemia is a simple and convenient animal model however standardization of the injection procedures in the devascularized and control limb is lacking, thus rendering difficult the interpretation of results. The aim of this investigations was to evaluate neovascularization in a hindlimb murine model by means of 99mTc-HYNIC-ß-Ala-RGD. Methods: 99mTc-HYNIC-RGD analog was prepared using coligands. Ischemia was induced in Wistar rats by double- ligation of the common femoral artery. Radiolabeled RGD was injected after 2h, as well as 1, 3, 5, 7, 10 and 14 days. Uptake was evaluated by planar imaging and biodistribution studies. Results: The highest ratio between ischemia and control was achieved at the 7th day (2.62 ± 0.95), with substantial decrease by the 14th day. For pertechnetate the 7th day ratio was 0.87 ± 0.23. Scintigraphic image confirmed different uptakes. Conclusion: 99mTc-HYNIC-RGD analog concentrated in ischemic tissue by the time of widespread angiogenesis and pertechnetate confirmed reduction in blood flow. In this sense, the protocol can be recommended for ischemic models.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Introduction: the assessment of the activity of rheumatoid arthritis and juvenile idiopathic arthritis is made by means of different tools, respectively DAS-28 and JADAS.Objective: To compare DAS-28 and JADAS with scores of 71, 27 and 10 joint counts in juvenile idiopathic arthritis.Method: A secondary analysis of a phase III placebo-controlled trial, testing safety and efficacy of abatacept was conducted in 8 patients with 178 assessment visits. Joint count scores for active and limited joints, physician's and parents'global assessment by 0-10 cm Visual Analog Scale, and erythrocyte sedimentation rate normalized to 0-10 scale, in all visits. The comparison among the activity indices in different observations was made through Anova or adjusted gamma model. The paired observations between DAS-28 and JADAS 71, 27 and 10, respectively, were analyzed by linear regression.Results: There were significant differences among individual measures, except for ESR, in the first four months of biological treatment, when five of the eight patients reached ACR-Pedi 30, with improvement. The indices of DAS-28, JADAS 71, 27 and 10 also showed significant difference during follow-up. Linear regression adjusted model between DAS-28 and JADAS resulted in mathematical formulas for conversion: [DAS-28 = 0.0709 (JADAS 71) + 1.267] (R-2 = 0.49); [DAS-28 = 0.084 (JADAS 27) + 1.7404] (R-2 = 0.47) and [DAS-28 = 0.1129 (JADAS-10) + 1.5748] (R-2 = 0.50).Conclusion: The conversion of scores of DAS-28 and JADAS 71, 27 and 10 for this mathematical model would allow equivalent application of both in adolescents with arthritis. (C) 2014 Elsevier Editora Ltda. All rights reserved.