973 resultados para AUTOMATED SAMPLE PREPARATION
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Mestrado Integrado em Engenharia Química e Bioquímica
Resumo:
Enterococci are increasingly responsible for nosocomial infections worldwide. This study was undertaken to compare the identification and susceptibility profile using an automated MicrosScan system, PCR-based assay and disk diffusion assay of Enterococcus spp. We evaluated 30 clinical isolates of Enterococcus spp. Isolates were identified by MicrosScan system and PCR-based assay. The detection of antibiotic resistance genes (vancomycin, gentamicin, tetracycline and erythromycin) was also determined by PCR. Antimicrobial susceptibilities to vancomycin (30 µg), gentamicin (120 µg), tetracycline (30 µg) and erythromycin (15 µg) were tested by the automated system and disk diffusion method, and were interpreted according to the criteria recommended in CLSI guidelines. Concerning Enterococcus identification the general agreement between data obtained by the PCR method and by the automatic system was 90.0% (27/30). For all isolates of E. faecium and E. faecalis we observed 100% agreement. Resistance frequencies were higher in E. faecium than E. faecalis. The resistance rates obtained were higher for erythromycin (86.7%), vancomycin (80.0%), tetracycline (43.35) and gentamicin (33.3%). The correlation between disk diffusion and automation revealed an agreement for the majority of the antibiotics with category agreement rates of > 80%. The PCR-based assay, the van(A) gene was detected in 100% of vancomycin resistant enterococci. This assay is simple to conduct and reliable in the identification of clinically relevant enterococci. The data obtained reinforced the need for an improvement of the automated system to identify some enterococci.
Resumo:
Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Biomédica
Resumo:
Dissertation to obtain the Master Degree in Biotechnology
Resumo:
RESUMO - O presente trabalho pretende estudar a cultura de segurança de doente em alunos do ensino superior, na área das tecnologias de diagnóstico e terapêutica. Esta problemática não tem sido abordada pela comunidade científica, pelo que o seu estudo é relevante. Os alunos que finalizam a licenciatura estão legalmente autorizados para intervir perante o doente, contudo, a sensibilidade que têm para as questões da segurança do doente deve ser analisada com o intuito de melhorar a sua preparação como futuros profissionais de saúde. Neste estudo participaram 180 alunos estratificados consoante o curso e sexo de modo a obter uma amostra representativa da população alvo. Foi constituído um questionário com 31 itens numa escala dicotómica que avaliam a cultura de segurança do doente em 7 dimensões – liderança, trabalho de equipa, a prática baseada na evidência científica, a comunicação, a aprendizagem, a justiça, e a prática clínica centrada no doente. Pode igualmente compor-se uma medida global de cultura de segurança do doente através do somatório das 7 dimensões. Os resultados evidenciam a existência de uma correlação positiva moderada entre as dimensões – Trabalho em equipa (0,660); Liderança (0,610); Prática baseada na evidência científica (0,627); Ambiente justo (0,570); Comunicação (0,501) e o Total.
Resumo:
The hemolytic power of rattlesnake venom (Crotalus durissus terrificus) was Studied. A high percentage of sample with negative hemolytic power was detected when sheep red blood cells were used. A large number of venoms with hemolytic power, though with a low hemolysis percentage, were detected when liquid, recently extracted venom was used. When crystallized venom was used under the same experimental conditions, a higher percentage ofpositivityfor hemolysis was obtained. When the results obtained on agar plates were compared to those obtained in test tubes, a large number of animals with a higher percentage of hemolysis were detected, though this value was not proportional to the number of animals showing positive plate hemolysis. When the hemolytic power of these venoms was tested on human red blood cells, a large percentage of animals with venoms having a low hemolytic power was also detected. Hemolytic power was much greater when human red blood cells were tested with crystallized venom. The preparation of red blood cells also had an important effect and the use of red blood cells from defibrinated blood is recommended. We conclude that rattlesnake venom has hemolytic power that increases when the venom is crystallized. Red blood cells should be properly preparedfor the lysis reactions. We suggest that the lytic power of the venom is related to venom concentration and to the purity of its fractions.
Resumo:
Dissertation presented to Faculdade de Ciências e Tecnologia, Universidade Nova de Lisboa for obtaining the master degree in Membrane Engineering
Resumo:
The influence of time and temperature on the storage of an alkaline antigen of L.major-like and L.(V.) braziliensis promastigotes added or not of a proteases inhibitor (PMSF) was evaluted by means of an IgG-ELISA. Antibodies in assays using L. major-like antigen stored at -20oC for 6 monsths had a statistically lower geometric mean titer (GMT) and different 95% confidence interval limits (CL) than antigens stored otherwise, as assessed by the "t" statistic. The PMSF L. major-like antigen after storage for 6 months at a temperature of 4oC had the same GMT and 95% CL displayed at time zero as well as when storage for 4 and 6 months at -20oC. Significant diferences were not found when L.(V.) braziliensis antigens were stored at times and temperatures mentioned; the PMSF antigen stored for 2 months at -70oC resulted in a lower serum GMT and 95% CL than any other, as assessed by the "t" statistic. Antigen performance did not show any statistical difference associated to the addition of PMSF within the same species; the largest difference between antigens was that between PMSF-L. (V.) braziliensis and L. major-like without PMSF.
Resumo:
RESUMO: As Análises Clínicas são um precioso elemento entre os meios complementares de diagnóstico e terapêutica permitindo uma enorme panóplia de informações sobre o estado de saúde de determinado utente. O objetivo do laboratório é fornecer informação analítica sobre as amostras biológicas, sendo esta caracterizada pela sua fiabilidade, relevância e facultada em tempo útil. Assim, tratando-se de saúde, e mediante o propósito do laboratório, é notória a sua importância, bem como, a dos fatores associados para o cumprimento do mesmo. O bom desenrolar do ciclo laboratorial, compreendido pelas fases pré-analítica, analítica e pós-analítica é crucial para que o objetivo do laboratório seja cumprido com rigor e rapidez. O presente trabalho “O Erro na Fase Pré-Analítica: Amostras Não Conformes versus Procedimentos”, enquadrado no mestrado de Qualidade e Organização no Laboratório de Análises Clínicas, pretendeu enfatizar a importância da fase pré- analítica, sendo ela apontada como a primordial em erros que acabam por atrasar a saída de resultados ou por permitir que os mesmos não sejam fidedignos como se deseja, podendo acarretar falsos diagnósticos e decisões clínicas erradas. Esta fase, iniciada no pedido médico e finalizada com a chegada das amostras biológicas ao laboratório está entregue a uma diversidade de procedimentos que acarretam, por si só, uma grande diversidade de intervenientes, para além de uma variabilidade de factores que influenciam a amostra e seus resultados. Estes fatores, que podem alterar de algum modo a “veracidade” dos resultados analíticos, devem ser identificados e tidos em consideração para que estejamos convitos que os resultados auxiliam diagnósticos precisos e uma avaliação correta do estado do utente. As colheitas que por quaisquer divergências não originam amostras que cumpram o objectivo da sua recolha, não estando por isso em conformidade com o pretendido, constituem uma importante fonte de erro para esta fase pré-analítica. Neste estudo foram consultados os dados relativos a amostras de sangue e urina não conformes detetadas no laboratório, em estudo, durante o 1º trimestre de 2012, para permitir conhecer o tipo de falhas que acontecem e a sua frequência. Aos Técnicos de Análises Clínicas, colaboradores do laboratório, foi-lhes pedido que respondessem a um questionário sobre os seus procedimentos quotidianos e constituíssem, assim, a população desta 2ª parte do projeto. Preenchido e devolvido de forma anónima, este questionário pretendeu conhecer os procedimentos na tarefa de executar colheitas e, hipoteticamente, confrontá-los com as amostras não conformes verificadas. No 1ºsemestre de 2012 e num total de 25319 utentes registaram-se 146 colheitas que necessitaram de repetição por se verificarem não conformes. A “amostra não colhida” foi a não conformidade mais frequente (50%) versus a “má identificação” que registou somente 1 acontecimento. Houve ainda não conformidades que não se registaram como “preparação inadequada” e “amostra mal acondicionada”. Os técnicos revelaram-se profissionais competentes, conhecedores das tarefas a desempenhar e preocupados em executá-las com qualidade. Eliminar o erro não estará, seguramente, ao nosso alcance porém admitir a sua presença, detetá-lo e avaliar a sua frequência fará com que possamos diminuir a sua existência e melhorar a qualidade na fase pré-analítica, atribuindo-lhe a relevância que desempenha no processo laboratorial.-----------ABSTRACT:Clinical analyses are a precious element among diagnostic and therapeutic tests as they allow an enormous variety of information on the state of health of a user. The aim of the laboratory is to supply reliable, relevant and timely analytical information on biological samples. In health-related matters, in accordance with the objective of the laboratory, their importance is vital, as is the assurance that all the tools are in place for the fulfillment of its purpose. A good laboratory cycle, which includes the pre-analytical, analytical and post-analytical phases, is crucial in fulfilling the laboratory’s mission rapidly and efficiently. The present work - "Error in the pre-analytical phase: non-compliant samples versus procedures”, as part of the Master’s in Quality and Organization in the Clinical Analyses Laboratory, wishes to emphasize the importance of the pre-analytical phase, as the phase containing most errors which eventually lead to delays in the issue of results, or the one which enables those results not to be as reliable as desired, which can lead to false diagnosis and wrong clinical decisions. This phase, which starts with the medical request and ends with the arrival of the biological samples to the laboratory, entails a variety of procedures, which require the intervention of different players, not to mention a great number of factors, which influence the sample and the results. These factors, capable of somehow altering the “truth” of the analytical results, must be identified and taken into consideration so that we may ensure that the results help to make precise diagnoses and a correct evaluation of the user’s condition. Those collections which, due to any type of differences, do not originate samples capable of fulfilling their purpose, and are therefore not compliant with the objective, constitute an important source of error in this pre-analytical phase. In the present study, we consulted data from non-compliant blood and urine samples, detected at the laboratory during the 1st quarter of 2012, to find out the type of faults that happen and their frequency. The clinical analysis technicians working at the laboratory were asked to fill out a questionnaire regarding their daily procedures, forming in this way the population for this second part of the project. Completed and returned anonymously, this questionnaire intended to investigate the procedures for collections and, hypothetically, confront them with the verified non-compliant samples. In the first semester of 2012, and out of a total of 25319 users, 146 collections had to be repeated due to non-compliance. The “uncollected sample” was the most frequent non-compliance (>50%) versus “incorrect identification” which had only one occurrence. There were also unregistered non-compliance issues such as “inadequate preparation” and “inappropriately packaged sample”. The technicians proved to be competent professionals, with knowledge of the tasks they have to perform and eager to carry them out efficiently. We will certainly not be able to eliminate error, but recognizing its presence, detecting it and evaluating its frequency will help to decrease its occurrence and improve quality in the pre-analytical phase, giving it the relevance it has within the laboratory process.
Resumo:
A avaliação de terras é o processo que permite estimar o uso potencial da terra com base em seus atributos. Grande variedade de modelos analíticos pode ser usada neste processo. No Brasil, os dois sistemas de avaliação das terras mais utilizados são o Sistema de Classificação da Capacidade de Uso da Terra e o Sistema FAO/Brasileiro de Aptidão Agrícola das Terras. Embora difiram em vários aspectos, ambos exigem o cruzamento de inúmeras variáveis ambientais. O ALES (Automated Land Evaluation System) é um programa de computador que permite construir sistemas especialistas para avaliação de terras. As entidades avaliadas pelo ALES são as unidades de mapeamento, as quais podem ser de caráter generalizado ou detalhado. A área objeto desta avaliação é composta pelas microrregiões de Chapecó e Xanxerê, no Oeste catarinense, e engloba 54 municípios. Os dados sobre os solos e sobre as características da paisagem foram obtidos no levantamento de reconhecimento dos solos do Estado, na escala de 1:250.000. O presente estudo desenvolveu o sistema especialista ATOSC (Avaliação das Terras do Oeste de Santa Catarina) e, na sua construção, incluiu-se a definição dos requerimentos dos tipos de utilização da terra, bem como foi feita a subsequente comparação destes com os atributos de cada unidade de mapeamento. Os tipos de utilização da terra considerados foram: feijão, milho, soja e trigo, em cultivos solteiros, sob condições de sequeiro e de manejo característicos destas culturas no Estado. As informações sobre os recursos naturais compreendem os atributos climáticos, de solos e das condições da paisagem que interferem na produção destas culturas. Para cada tipo de utilização da terra foram especificados, no ATOSC, o código, o nome e seus respectivos requerimentos de uso da terra. Os requerimentos de cada cultura foram definidos por uma combinação específica das características das terras selecionadas, que determina o nível de severidade de cada um deles em relação à cultura. Estabeleceram-se quatro níveis de severidade que indicam aumento do grau de limitação ou diminuição do potencial para determinado tipo de uso da terra, a saber: limitação nula ou ligeira (favorável); limitação moderada (moderadamente favorável), limitação forte (pouco favorável); e limitação muito forte (desfavorável). Na árvore de decisão, componente básico do sistema especialista, são implementadas as regras que permitirão o enquadramento das terras em classes de adequação definidas, baseado na qualidade dos requerimentos de acordo com o tipo de uso. O ATOSC facilitou o processo de comparação entre as características das terras das microrregiões de Chapecó e Xanxerê e os requerimentos de uso considerados, por permitir efetuar automaticamente a avaliação das terras, reduzindo, assim, o tempo gasto neste processo. As terras das microrregiões de Chapecó e Xanxerê foram enquadradas, em sua maior parte, nas classes de adequação pouco favorável (3) e desfavorável (4) para os cultivos considerados. Os principais fatores limitantes identificados nestas microrregiões foram a fertilidade natural e o risco de erosão, para o feijão e o milho, e condições de mecanização e risco de erosão, para a soja e o trigo.
Resumo:
Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.
Resumo:
Detection of anti-toxoplasma IgM antibodies has frequently been used as a serological marker for diagnosing recently acquired toxoplasmosis. However, the persistence of these antibodies in some patients has complicated the interpretation of serological results when toxoplasmosis is suspected. The purpose of the present study was to evaluate the avidity of IgG antibodies against excreted/secreted antigens of Toxoplasma gondii by means of immunoblot, to establish a profile for acute recent infection in a single serum sample and confirm the presence of residual IgM antibodies obtained in automated assays. When we evaluated the avidity of IgG antibodies against excreted/secreted antigens of Toxoplasma gondii by means of immunoblot, we observed phase-specific reactivity, i.e. cases of acute recent toxoplasmosis presented low avidity and cases of non-acute recent toxoplasmosis presented high avidity towards the 30kDa protein fraction, which probably corresponds to the SAG-1 surface antigen. Our results suggest that the avidity of IgG antibodies against excreted/secreted antigens of Toxoplasma gondii is an important immunological marker for distinguishing between recent infections and for determining the presence of residual IgM antibodies obtained from automated assays.
Resumo:
There were two main objectives in this thesis investigation, first, the production, characterisation, in vitro degradation and release studies of double walled microspheres for drug release control. The second one, and the most challenging, was the production of double walled nanospheres, also for drug control delivery. The spheres were produced using two polymers, the Poly(L-lactide)Acid, PLLA, and the Poly(L-lactide-co-glycolic)Acid, PLGA.Afterwards, a model drug, Meloxicam, which is an antiinflammatory drug, was encapsulated into the particles. Micro and nanospheres were produced by the solvent extraction/evaporation method, where perfect spherical particles were obtained. By varying the polymers PLLA/PLGA mass ratio, different core and shell composition, as well as several shell and core thickness were observed. In the particles with a PLLA/PLGA mass ratio 1:1, the shell is composed by PLLA and the core by PLGA. It was also verified that the Meloxicam has a tendency to be distributed in the PLGA layer. Micro and nanoparticles were characterised in morphology, size, polymer cristalinity properties and drug distribution. Particles degradation studies was performed, where the particles in a PVA solution of pH 7,4 where placed in an incubator, during approximately 40 days, at 120rpm, and 37ºC, simulating, as much as possible, the human body environment. From these studies, the conclusion was that particles containing a PLGA shell and a PLLA core degrade more rapidly, due to the fact that PLLA is more hydrophobic than the PLGA. Concerning the drug release controlled results, done also for 40 and 50 days, they showed that the microspheres containing a shell of PLLA release more slowly than when the shell is composed of PLGA. This result was predictable, since the drug is solubilised in the PLGA polymer and so, in that case, the PLLA shell works like a barrier between the drug and the outer medium. Another positive aspect presented by this study is the lower initial burst effect, obtained when using double walled particles, which is one of the advantages of the same. In a second part of this investigation, the production of the nanospheres was the main goal, since it was not yet accomplished by other authors or investigators. After several studies, referring to the speed, time and type of agitation, as well as, the concentration and volume of the first aqueous solution of poly-vinyl-alcohol (PVA) during the process of solvent extraction/evaporation it was possible to obtain double walled nanospheres.(...)
Resumo:
The aims of this study were to carry out a serological survey of canine leishmaniasis and identify the phlebotomine fauna in the urban area of Bonito, Mato Grosso do Sul. The serological survey was conducted on a sample of 303 dogs, by means of the indirect immunofluorescence test. Phlebotomines were captured using automated light traps. The serological survey found that 30% of the dogs were seropositive, both from the center and from all districts of the town. A total of 2,772 specimens of phlebotomines were caught and the species most found was Lutzomyia longipalpis (90.4%), which corroborated its role as the vector of for canine visceral leishmaniasis in the region. Phlebotomines of the species Bichromomyia flaviscutellata (the main vector for Leishmania (Leishmania) amazonensis) and Nyssomyia whitmani (the vector for Leishmania (Viannia) brasiliensis) were also caught. The findings indicate the need for continuous epidemiological surveillance, with attention towards diminishing the vector breeding sites and the transmission of these diseases in that region.