847 resultados para total energy expenditure
Resumo:
There is a great global concern about the depletion and the high cost of fossil fuel reserves exploitation, more than ever, it is necessary to make a profound study and take advantage of alternative sources that can be used as energy efficiency with an appropriate pricing and low environmental impact. Brazil, which has highlighted using alternative energy sources as the use of ethanol and, in recent years, has been encouraging the expansion of its energy matrix in which the biodiesel will have a strategic importance within the agrobusiness area. Biodiesel is a fuel that can replace the diesel, which is a petroleum derivative. It is an ester, produced in the transesterification reaction of vegetable oils and animal greases, in an alcohol with an additional catalyst, are converted into fatty acids and result in esters with glycerol as sub products. The objective of this study was to estimate the final energy balance for the process biodiesel production from oil chicken waste. The energy balance estimation was quantified in calorific value according to the energy expenditure by calorimetric bomb method. The relationship between input and output of energy was around 0.97. In a first evaluation, the procedures adopted should be improved enough, so the process can become energetic and economically viable.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
This study aimed to analyze the energy efficiency ratings and cost of farming families producing milk in the city of Pardinho (SP). The hypothesis that guides the study is that energy expenditure may be coincident with the economic expenditure showing that there is a relationship between these flows, which can be sustainable or not. To better define the producers studied criteria were used in the official system of rural credit FEAP. Through primary data obtained by the speeches, the itineraries were reconstituted technical detailing the operations employed. Thus, we found two producers with different technical routes. The producer was the one who got one of the highest efficiencies 8.66 and 1.48 respectively. Related to the efficiency, we can see that are close related and when there is a broader idea of the allocation of energy resources and, thus, a better view of the sustainability of the agro ecosystem.
Resumo:
The objective of this work was to evaluate the energy and economic efficiency indexes per unit of cotton agro-ecosystem area in family production systems of Paraguay and Brazil; and, to establish a relationship between the energy and economic. Typologies presented by the Program to Support Small Cotton Holdings (Paraguay), and by the National Program for Strengthening Family Agriculture (Brazil). Family systems of the two countries were identified; these are located from Paraguay (San Juan–CA) and from Brazil (Leme–SP). To construct the energy expenditure structure of the cotton agro-ecosystem, as well as to assess the economic efficiency, the mean values obtained were considered, when they presented similarities in production systems and they were within the typology proposed in this study. From the technical itinerary observed the Paraguayan agro-ecosystem depended (fossil fuel 56.76%) and industrial source (35.99%). Thus, the energy balance of the agricultural stage was established, which attained a value of 17,740.69 MJ ha-1; an energy efficiency of 5.28, and a cultural efficiency of 3.04. The Brazilian agro-ecosystem depended on energy from industrial source (insecticides 39.82%) and from fossil fuel (33.59%); it reached an energy balance of 19,547.88 MJ ha-1; an energy efficiency of 2.12, and a cultural efficiency index of 0.71. In the economic and energy indicator ratio, with regard to the months referring to the harvest time, that is to say, March, April, and May, the maximum economic efficiency indicator of paraguay was attained in the month of May (1,00), and from Brazil in the month of May (1,71). Both production systems analyzed were presented efficient, however, dependent of external circumstances and non-renewable energy sources.
Resumo:
The objective of this work was to evaluate the energy and economic efficiency indexes per unit of cotton agro-ecosystem area in family production systems of Paraguay and Brazil; and, to establish a relationship between the energy and economic. Typologies presented by the Program to Support Small Cotton Holdings (Paraguay), and by the National Program for Strengthening Family Agriculture (Brazil). Family systems of the two countries were identified; these are located from Paraguay (San Juan–CA) and from Brazil (Leme–SP). To construct the energy expenditure structure of the cotton agro-ecosystem, as well as to assess the economic efficiency, the mean values obtained were considered, when they presented similarities in production systems and they were within the typology proposed in this study. From the technical itinerary observed the Paraguayan agro-ecosystem depended (fossil fuel 56.76%) and industrial source (35.99%). Thus, the energy balance of the agricultural stage was established, which attained a value of 17,740.69 MJ ha-1; an energy efficiency of 5.28, and a cultural efficiency of 3.04. The Brazilian agro-ecosystem depended on energy from industrial source (insecticides 39.82%) and from fossil fuel (33.59%); it reached an energy balance of 19,547.88 MJ ha-1; an energy efficiency of 2.12, and a cultural efficiency index of 0.71. In the economic and energy indicator ratio, with regard to the months referring to the harvest time, that is to say, March, April, and May, the maximum economic efficiency indicator of paraguay was attained in the month of May (1,00), and from Brazil in the month of May (1,71). Both production systems analyzed were presented efficient, however, dependent of external circumstances and non-renewable energy sources.
Resumo:
The aim of this paper was to perform an energy assessment of firewood and woodshaving use for energy generation in sericulture agroindustry boilers. In this research, we used a boiler from a silk spinning factory located in the city of Duartina, São Paulo, Brazil, that currently uses eucalyptus firewood as fuel to generate water vapour used in silk fiber production. In the studied fuels utilization system energy consumption structure development, we considered energy input in Megajoule (MJ) by type, source and form involved in several firewood use technical itinerary operations, as well as in woodshaving use technical itinerary operations. From these fuels utilization built structure, we performed a firewood- and woodshaving-generated energy input comparative analysis, in Megajoule/hour (MJ.h-1), to produce 2.968,80 kg.h-1 of vapour, which is the boiler average production, during the following years: 2004, 2005, and 2006. The energy analysis results revealed that to replace eucalyptus firewood with woodshaving is something possible in the boiler, reducing total energy consumption approximately by 21%.
Resumo:
This study aimed to account the energy balance of six different farming systems: CMT (minimum tillage with transgenic corn); CMNT (minimum tillage with non-transgenic corn); PCT (conventional tillage with transgenic corn); PCNT (conventional tillage with non-transgenic corn); PDT (no-tillage system with transgenic corn) and PDNT (no-tillage system with non-transgenic corn). The study was carried out at the Experimental Farm Lageado FCA/Unesp, Botucatu - SP. The energy balance was performed by subtracting the total energy inputs by the total energy output. Energy efficiency was calculated by dividing the total energy output by the total energy inputs. The total values of energy inputs and outputs were expressed in MJ.ha-1 (mega joules per hectare). To calculate the energy inputs were accounted the fuel consumption and lubricants, depreciation energy of machinery and implements, manpower and agricultural inputs. The energy outputs were calculated according to the maize yield. The result shows that the system PDT was the system that had better energy efficiency and the system that had the lowest efficiency was the PCT system. The system with lower energy demand was the PDT and the greatest demand was PCNT.