975 resultados para three-step derivatization


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tese de Doutoramento em Ciências da Comunicação - Especialidade em Comunicação Estratégica e Organizacional

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia de Materiais

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The MAP-i Doctoral Programme in Informatics, of the Universities of Minho, Aveiro and Porto

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tese de Doutoramento em Psicologia (Especialidade de Psicologia Experimental e Ciências Cognitivas)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tese de Doutoramento em Engenharia Civil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To determine whether the use of 3-dimensional (3D) imaging translates into a better surgical performance of naïve urologic laparoscopic surgeons during pyeloplasty (PY) and partial nephrectomy (PN) procedures. Materials and Methods Eighteen surgeons without any previous laparoscopic experience were randomly assigned to perform PY and PN in a porcine model using initially 2-dimensional (2D) and 3D laparoscopy. A surgical performance score was rated by an "expert" tutor through a modified 5-item global rating scale contemplating operative field view, bimanual dexterity, efficiency, tissue handling, and autonomy. Overall surgical time, complications, subjective perception of participating surgeons, and inconveniences related to the 3D vision were recorded. Results No difference in terms if operative time was found between 2D or 3D laparoscopy for both the PY (P =.51) and the PN (P =.28) procedures. A better rate in terms of surgical performance score was noted by the tutors when the study participants were using 3D vs 2D, for both PY (3.6 [0.8] vs 3.0 [0.4]; P =.034) and PN (3.6 [0.51] vs 3.15 [0.63]; P =.001). No complications occurred in any of the procedures. Most (77.2%) of the participating na??ve laparoscopic surgeons had the perception that 3D laparoscopy was overall easier than 2D. Headache (18.1%), nausea (18.1%), and visual disturbance (18.1%) were the most common issues reported by the surgeons during 3D procedures. Conclusion Despite the absence of translation in a shorter operative time, the use of 3D technology seems to facilitate the surgical performance of naive surgeons during laparoscopic kidney procedures on a porcine model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT Objective To assess cardiorespiratory capacity through subjective and objective tests in older adults diagnosed with major depression (MDD), Alzheimer disease (AD) and healthy older adults. Methods Fifty seven subjects (72 ± 7.9 years) were divided into three groups: MDD (n = 20), AD (n = 17) and Healthy (n = 20). The subjects answered Hamilton Scale (HAM-D), Mini-Mental State Examination (MMSE), Veterans Specific Activity Questionnaire (VSAQ) and 2-minute Step test. Results MDD and AD showed lower scores than healthy group for Nomogram VSAQ (p < 0.001) and 2-minute Step (p = 0.009; p = 0.008, respectively). Adjusted for age and educational level, no differences among groups were observed for Step (MDD, p = 0.097; AD, p = 0.102). AD group did not present differences to healthy group for Step, when adjusting for MMSE (p = 0.261). Conclusions Despite the lower cardiorespiratory fitness of elderly patients with DM and DA have been found in both evaluations, the results should be viewed with caution, since the tests showed low correlation and different risk classifications of functional loss. In addition, age, level educational and cognitive performance are variables that can influence the performance objective evaluation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Here we focus on factor analysis from a best practices point of view, by investigating the factor structure of neuropsychological tests and using the results obtained to illustrate on choosing a reasonable solution. The sample (n=1051 individuals) was randomly divided into two groups: one for exploratory factor analysis (EFA) and principal component analysis (PCA), to investigate the number of factors underlying the neurocognitive variables; the second to test the "best fit" model via confirmatory factor analysis (CFA). For the exploratory step, three extraction (maximum likelihood, principal axis factoring and principal components) and two rotation (orthogonal and oblique) methods were used. The analysis methodology allowed exploring how different cognitive/psychological tests correlated/discriminated between dimensions, indicating that to capture latent structures in similar sample sizes and measures, with approximately normal data distribution, reflective models with oblimin rotation might prove the most adequate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de Mestrado (Programa Doutoral em Informática)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate echocardiography accuracy in performing and obtaining images for dynamical three-dimensional (3D) reconstruction. METHODS: Three-dimensional (3D) image reconstruction was obtained in 20 consecutive patients who underwent transesophageal echocardiography. A multiplanar 5 MHz transducer was used for 3D reconstruction. RESULTS: Twenty patients were studied consecutively. The following cardiac diseases were present: valvar prostheses-6 (2 mitral, 2 aortic and 2 mitral and aortic); mitral valve prolapse- 3; mitral and aortic disease - 2; aortic valve disease- 5; congenital heart disease- 3 (2 atrial septal defect- ASD - and 1 transposition of the great arteries -TGA); arteriovenous fistula- 1. In 7 patients, color Doppler was also obtained and used for 3D flow reconstruction. Twenty five cardiac structures were acquired and 60 reconstructions generated (28 of mitral valves, 14 of aortic valves, 4 of mitral prostheses, 7 of aortic prostheses and 7 of the ASD). Fifty five of 60 (91.6%) reconstructions were considered of good quality by 2 independent observers. The 11 reconstructed mitral valves/prostheses and the 2 reconstructed ASDs provided more anatomical information than two dimensional echocardiography (2DE) alone. CONCLUSION: 3D echocardiography using a transesophageal transducer is a feasible technique, which improves detection of anatomical details of cardiac structures, particularly of the mitral valve and atrial septum.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In Portugal, maize is the cereal that involves more agriculture explorations. Aspergillus spp., among other species, are usually associated with this cereal, during drying and storage, making this commodity susceptible to mycotoxins (such as aflatoxins, ochratoxins, and cyclopiazonic acid). The aim of this study was to evaluate the mycotoxigenic potential of isolated Aspergillus strains from these maize samples and correlate it with the sampling place, the weather conditions, and local practices during drying and storage. The samples were collected between November 2008 and April 2009 in maize association of producers facilities in Coimbra, Santarém and Portalegre. The isolated strains were divided in three distinct groups, Aspergillus section Flavi, Aspergillus section Nigri and others Aspergillus. The preliminary results show that there are differences between the incidence of these groups in the three sampling places, especially in Coimbra, probably due to a lower mean temperatures and higher humidity levels. These data will be presented and discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado em Ciências da Comunicação (área de especialização em Informação e Jornalismo)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado em Ciências da Comunicação (área de especialização em Informação e Jornalismo)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Beginning with a patient presenting with an atrial septal defect (ASD) of the secundum type, the genealogy was identified in four affected individuals who belonged to three successive generations of the same family. The defects were visually confirmed in all individuals and were found to be anatomically similar. No other congenital malformations were present in these individuals. The genealogy was identified in 1972, when ASD recurred in two generations, and it was concluded that the mechanism of transmission was autosomal recessive. The fifth individual, identified 21 years later, and having an anomaly identical to that of the others, was the child of a couple who had no consaguinity and whose mother was a member of the previously studied genealogy. Considering the absence of phenotype in the parents and the rarity of the ASD gene in the general population, the occurrence of the uniparental disomy for this family nucleus, and the same autosomal recessive mechanism of transmission by this affected individual is possible. This study reports the familial occurrence of ASD by genetic mechanisms of transmission, emphasizing the necessity for genetic-clinical studies in members of the familial nucleus in order to detect new carriers, who usually are asymptomatic, thereby allowing for early and adequate treatment of individuals who may be affected.