919 resultados para optical anisotropy


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Plasmas generated in de discharges in aromatic compounds have been used for several years in polymerization processes. The chemical kinetics developed in such a plasma environment are extremely complicated. Therefore it is extremely important to set up optical and electrical diagnostics in order to establish the kinetics of the film growth, In this work we studied de plasmas generated ill low-pressure atmospheres of benzene for different values of gas pressure and power coupled to the discharge. The pressure range varied from 0.2 to 1.0 mbar for electric power running from 4 to 25 W, the main chemical species observed within the discharge were CH, H and C. It was observed that the CH relative concentration increases continuously with the power in the range investigated. The electron temperature varied from 0.5 to 2.0 eV with the increase of the power, for a fixed value of gas pressure. The relative dielectric constant of the plasma polymerized benzene was kept around 4.8 from 100 Hz to 10 kHz, presenting a resonance near 25 kHz. This electric behaviour of the film was the same fur different conditions of polymeric film deposition, (C) 1997 Elsevier B.V. S.A.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Modern industry has frequently employed ethylene glycol ethers as monomers in plasma polymerization process to produce different types of coatings. In this work we used a stainless steel plasma reactor to grow thin polymeric films from low pressure RF excited plasma of diethylene glycol dimethyl ether. Plasmas were generated at 5W RF power in the range of 16 Pa to 60 Pa. The molecular structure of plasma polymerized films and their optical properties were analyzed by Fourier Transform Infrared Spectroscopy (FTIR) and UltravioletVisible Spectroscopy, respectively. The IR spectra show C-H stretching at 3000-2900 cm(-1), C=O stretching at 1730-1650 cm(-1), C-H bending at 1440-1380 cm(-1), C-O and C-O-C stretching at 1200-1000 cm(-1). The refraction index was around 1.5 and the optical gap calculated from absorption coefficient presented value near 3.8 eV. Water contact angle of the films ranged from 40 degrees to 35 degrees with corresponding surface energy from 66 to 73x10(-7) J. Because of its favorable optical and hydrophilic characteristics these films can be used in ophthalmic industries as glass lenses coatings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An interferometric technique was used to determine the temperature coefficient of the optical path length (dS/dT) as a function of the temperature in several optical glasses. The temperature range was between 25degreesC and 180degreesC. The studied samples included undoped and doped oxide glasses, such as low silica calcium aluminosilicate, phosphates, borates and also chalcogenides. The oxide glasses had dS/dT between 10 X 10(-6) K-1 and 20x10(-6) K-1, while for the chalcogenides, these were around 70 x 10(-6)K(-1). The results showed that dS/dTs increased with the temperature in all samples. For samples doped with Nd the dS/dT values were found to be independent of concentration. on the other hand, for the phosphate glass doped with Cr, dS/dT increased about 5% when compared with the Nd doped one. In conclusion, the used interferometric method, which is a considerably simpler and a lower cost technique, and is a useful tool to measure dS/dT in semi-transparent glasses as a function of the composition and temperature. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work has as objective to develop an interesting research line in the Optical Instrumentation area, that is to associate the Optical Design to the Ophthalmology area. The purpose of it is handling the optical design techniques to design a widely used ophthalmologic instrument called slit lamp. The optical and mechanical design of the slit lamp prototype was carefully projected in order to improve the best quality image, the comfort of the patient and the user, the simplicity of handling, the facility of production the availability of optical and mechanical components in the national market and the low cost of production. The main goal of this work was to realize a project using totally national technology, cheapening the cost and forming the optimum image required for the slit lamp optical system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work we have developed a way to grow Fe/MgO(100) monocrystals by magnetron sputtering DC. We investigated the growing in a temperature range among 100 oC and 300 oC. Structural and magneto-crystalline properties were studied by different experimental techniques. Thickness and surface roughness of the films were investigated by atomic force microscopy, while magneto-crystalline properties were investigated by magneto-optical Kerr effect and ferromagnetic resonance. Our results show that as we increase the deposition temperature, the magneto-crystalline anisotropy of the films also increases, following the equation of Avrami. The best temperature value to make a film is 300 oC. As the main result, we built a base of magnetoresistence devices and as an aplication, we present measurements of Fe/Cr/Fe trilayer coupling. In a second work we investigated the temperature dependence of the first three interlayer spacings of Ag(100) surface using low energy electron diffraction. A linear expansion model of crystal surface was used and the values of Debye temperatures of the first two layers and thermal expansion coefficient were determinated. A relaxation of 1% was found for Ag(100) surface and these results are matched with faces (110) and (111) of the silver. iv

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study was carried out at Faculdade de Medicina Veterinária e Zootecnia, Universidade Estadual Paulista, Botucatu, SP, Brazil, and evaluated bone quality in broiler breeders. Twenty-three families of Ross broiler breeders were housed in 5.0-m² pens. The families were comprised of 13 females and one male at the onset of the experimental period. The mean number of females per family was 9.34 at the end of the trial. The feeding program and management followed strain guidelines (Agroceres Ross, 2003). Bone analyses were performed in the right tibia and femur using optical radiographic densitometry at 4, 8, 12, 15, 20, 24, 30, 35, 42, 47 and 52 weeks of rearing. Trap nests were used to collect eggs from the breeders two weeks before and after the evaluation weeks. At each evaluation day, five birds were sacrificed after radiographs were taken and the tibias and femurs were collected to perform the following analyses: fatfree dry matter, ash percentage, bone resistance and Seedor index. Therefore, it was possible to establish correlations between bone quality and eggshell quality. Characteristics of bone quality were highly correlated to each other; on the other hand, there were no correlations between bone quality and external egg quality. In conclusion, there was no effect of egg production on egg quality, possibly because there was no reabsorption of bone minerals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Em 12 fêmeas e 12 machos da raça Puro Sangue Inglês com idade média de 12 meses, avaliou-se os valores normais da densidade mineral óssea do carpo acessório em milímetros de alumínio (mmAl) até o momento do fechamento completo da epífise distal do rádio, por meio do método de densitometria óptica em imagens radiográficas. A avaliação foi realizada por meio de um programa computacional (software) especialmente desenvolvido para medida de densidade óptica em filmes de raios-X, o qual contém a imagem radiográfica do osso carpo acessório, região de partes moles adjacente ao carpo acessório e os degraus de uma escala de alumínio (phatom), que permitiu a medida de densidade mineral óssea, sendo esta a média aritmética da região de interesse determinada no osso carpo acessório correspondente ao valor em milímetros da escala. Os valores da densidade mineral óssea em mmAl do acessório do carpo em função da idade não apresentaram diferenças entre os sexos (p=0,86) permitindo que uma equação de reta fosse ajustada para ambos os sexos (densidade mineral óssea (DMO) mmAl = 3.109 + 0,056 x idade em meses), na faixa etária estudada.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Computer-aided design/computer-aided manufacturing images can be taken through either direct or indirect imaging. For the indirect systems, the digitalization is obtained from the impression material or cast, and for the direct ones the image is taken directly from the mouth using intraoral scanners.The direct acquisition systems have been constantly improved because these are less invasive, quicker, and more precise than the conventional method. Besides, the digital images can be easily stored for a long time. Therefore, the aim of this paper was to describe and discuss based on the literature the main direct image acquisition systems available on the market: CEREC Bluecam (Sirona), Lava C.O.S. System (3M ESPE), iTero System (Cadent/Straumann), and E4D System (D4D Technologies).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Some photosensitizers (PSs) used for PACT (Antimicrobial Photodynamic Therapy) show an affinity for bacterial walls and can be photo-activated to cause the desired damage. However, on dentine bacterias may be less susceptible to PACT as a result of limited penetration of the PS. The aim of this study was to evaluate the diffusion of one PS based on hematoporphyrin on dentine structures. Twelve bovine incisors were used. Class III cavities (3 x 3 x 1 mm) were prepared on the mesial or distal surfaces using a diamond bur. Photogem (R) solution at 1 mg/mL (10 uL for each cavity) was used. The experimental Groups were divided according to thickness of dentine remaining and etched or no-etched before the PS application. The fluorescence excitation source was a VelScope (R) system. For image capture a scientific CCD color camera PixelFly (R) was coupled to VelScope. For image acquisition and processing, a computational routine was developed at Matlab (R). Fick's Law was used to obtain the average diffusion coefficient of PS. Differences were found between all Groups. The longitudinal temporal diffusion was influenced by the different times, thickness and acid etching.