948 resultados para non invasive sampling
Resumo:
While histopathology of excised tissue remains the gold standard for diagnosis, several new, non-invasive diagnostic techniques are being developed. They rely on physical and biochemical changes that precede and mirror malignant change within tissue. The basic principle involves simple optical techniques of tissue interrogation. Their accuracy, expressed as sensitivity and specificity, are reported in a number of studies suggests that they have a potential for cost effective, real-time, in situ diagnosis.
Resumo:
Background Independent of other cardiovascular (CV) risk factors, increased arterial stiffness has been established as a predictor of morbidity and mortality. The main aim of this study was to investigate the impact of diabetes on arterial stiffness in a representative sample of an urban Brazilian population plus Amerindians. Methods A total of 1,415 individuals from the general population were randomly selected plus 588 Amerindians from a native community in Brazil. In addition, a sub-sample of 380 individuals from the general population had 5-year follow-up data. Pulse wave velocity (PWV) was measured with a non-invasive automatic device (Complior, Colson; Garges les Gonesses, France) and increased arterial stiffness was defined as PWV ≥ 12 m/s. Results In the overall group, diabetic individuals had higher frequencies of increased arterial stiffness and hypertension. They also had higher values of PWV, body mass index, total cholesterol, triglycerides, systolic and diastolic blood pressures compared to non-diabetic individuals (p < 0.01). In an analysis stratified by hypertension, PWV values and increased arterial stiffness frequency were higher in diabetic individuals in both groups (hypertensive and non-hypertensive) (p < 0.05). Furthermore, higher risk for increased arterial stiffness was observed in the diabetic individuals from the overall group (OR = 2.27; CI = 1.47-3.52, p < 0.001) and from the hypertensive group (OR = 2.70; CI = 1.58-4.75, p < 0.001), adjusted for covariates. Regarding the ethnic stratification, diabetic individuals from Amerindian, White, and Mulatto (mixed-race) groups had higher PWV values and a greater frequency of increased arterial stiffness compared to non-diabetic individuals. Both diabetic and non-diabetic individuals had higher PWV values after 5 years. There was no significant difference in the 5-year PWV progression in diabetic compared to non-diabetic individuals. Conclusions These results confirm, in a sample of Brazilian population, that the presence of diabetes is associated with increased arterial stiffness and it may contribute in part to increased cardiovascular risk in diabetic patients.
Resumo:
Transcranial sonography has become a useful tool in the differential diagnosis of parkinsonian syndromes. This is a non-invasive, low cost procedure. The main finding on transcranial sonography in patients with idiopathic Parkinson's disease is an increased echogenicity of the mesencephalic substantia nigra region. This hyperechogenicity is present in more than 90% of cases, and reflects a dysfunction in the dopaminergic nigrostriatal pathway. This study discussed how the hyperechogenicity of the substantia nigra may facilitate the differential diagnosis of parkinsonian syndromes.
Resumo:
Background: The methods used for evaluating wound dimensions, especially the chronic ones, are invasive and inaccurate. The fringe projection technique with phase shift is a non-invasive, accurate and low-cost optical method. Objective: The aim is to validate the technique through the determination of dimensions of objects of known topography and with different geometries and colors to simulate the wounds and tones of skin color. Taking into account the influence of skin wound optical factors, the technique will be used to evaluate actual patients’ wound dimensions and to study its limitations in this application. Methods: Four sinusoidal fringe patterns, displaced ¼ of period each, were projected onto the objects surface. The object dimensions were obtained from the unwrapped phase map through the observation of the fringe deformations caused by the object topography and using phase shift analysis. An object with simple geometry was used for dimensional calibration and the topographic dimensions of the others were determined from it. After observing the compatibility with the data and validating the method, it was used for measuring the dimensions of real patients’ wounds. Results and Conclusions: The discrepancies between actual topography and dimensions determined with Fringe Projection Technique and for the known object were lower than 0.50 cm. The method was successful in obtaining the topography of real patient’s wounds. Objects and wounds with sharp topographies or causing shadow or reflection are difficult to be evaluated with this technique.
Resumo:
PREMESSA: La progressione della recidiva d’epatite C è accelerata nei pazienti sottoposti a trapianto di fegato e ciò ha portato alla necessità di sviluppare nuove e validate metodiche non invasive per la quantificazione e la misura della fibrosi epatica. SCOPI: Stabilire l’efficacia dell’elastometria epatica (Fibroscan®) e dei parametri sierici di fibrosi, attualmente disponibili nella pratica clinica, per predire il grado di fibrosi nei pazienti sottoposti a trapianto epatico. METODI: La correlazione fra fibrosi epatica, determinata mediante biopsia epatica ed esame istologico, e Fibroscan® o indici clinico-sierologici di fibrosi (Benlloch, Apri, Forns, Fibrotest and Doppler resistance index), è stata studiata in pazienti che avevano ricevuto un trapianto ortotopico di fegato con evidenza di recidiva d’epatite da HCV. Un totale di 36 pazienti, con la seguente classificazione istologica: fibrosi secondom METAVIR F1=24, F2=8, F3=3, F4=1, sono stati arruolati nella popolazione oggetto di studio. Un totale di 29 individui volontari sani sono serviti come controllo. Le differenze fra gli stadi di fibrosi sono state calcolate mediante analisi statistica non parametrica. Il miglior cut-off per la differenziazione di fibrosi significativa (F2-F4) è stato identificato mediante l’analisi delle curve ROC. RISULTATI: La rigidità epatica ha presentato valori di 4.4 KPa (2.7-6.9) nei controlli (mediane e ranges), con valori in tutti i soggeti <7.0 KPa; 7.75 KPa (4.2-28.0) negli F1; 16.95 KPa (10.2-31.6) negli F2; 21.10 KPa nell’unico paziente F4 cirrotico. Le differenze sono state statisticamente significative per i soggetti controllo versus F1 e F2 (p<0.0001) e per F1 versus F2 (p<0.0001). Un cut-off elastografico di 11.2 KPagarantisce 88% di Sensibilità, 90% di Specificità, 79% di PPV e 95% di NPV nel differenziare i soggetti F1 dagli F2-F4. Le AUROC, relativamente alla capacità di discriminare fra i differenti gradi di fibrosi, evidenziavano un netto vantaggio per il Fibroscan® rispetto ad ognuno degli indici non invasivi di fibrosi. CONCLUSIONI: L’elastometria epatica presenta una buona accuratezza diagnostica nell’identificare pazienti con fibrosi epatica di grado significativo, superiore a quella di tutti gli altri test non invasivi al momento disponibili nella clinica, nei pazienti portatori di trapianto epatico ortotopico da cadavere con recidiva di HCV.
Resumo:
This research investigated someone of the main problems connected to the application of Tissue Engineering in the prosthetic field, in particular about the characterization of the scaffolding materials and biomimetic strategies adopted in order to promote the implant integration. The spectroscopic and thermal analysis techniques were usefully applied to characterize the chemico-physical properties of the materials such as – crystallinity; – relative composition in case of composite materials; – Structure and conformation of polymeric and peptidic chains; – mechanism and degradation rate; – Intramolecular and intermolecular interactions (hydrogen bonds, aliphatic interactions). This kind of information are of great importance in the comprehension of the interactions that scaffold undergoes when it is in contact with biological tissues; this information are fundamental to predict biodegradation mechanisms and to understand how chemico-physical properties change during the degradation process. In order to fully characterize biomaterials, this findings must be integrated by information relative to mechanical aspects and in vitro and in vivo behavior thanks to collaborations with biomedical engineers and biologists. This study was focussed on three different systems that correspond to three different strategies adopted in Tissue Engineering: biomimetic replica of fibrous 3-D structure of extracellular matrix (PCL-PLLA), incorporation of an apatitic phase similar to bone inorganic phase to promote biomineralization (PCL-HA), surface modification with synthetic oligopeptides that elicit the interaction with osteoblasts. The characterization of the PCL-PLLA composite underlined that the degradation started along PLLA fibres, which are more hydrophylic, and they serve as a guide for tissue regeneration. Moreover it was found that some cellular lines are more active in the colonization of the scaffold. In the PCL-HA composite, the weight ratio between the polymeric and the inorganic phase plays an essential role both in the degradation process and in the biomineralization of the material. The study of self-assembling peptides allowed to clarify the influence of primary structure on intermolecular and intermolecular interactions, that lead to the formation of the secondary structure and it was possible to find a new class of oligopeptides useful to functionalize materials surface. Among the analytical techniques used in this study, Raman vibrational spectroscopy played a major role, being non-destructive and non-invasive, two properties that make it suitable to degradation studies and to morphological characterization. Also micro-IR spectroscopy was useful in the comprehension of peptide structure on oxidized titanium: up to date this study was one of the first to employ this relatively new technique in the biomedical field.
Resumo:
Introduction The “eversion” technique for carotid endarterectomy (e-CEA), that involves the transection of the internal carotid artery at the carotid bulb and its eversion over the atherosclerotic plaque, has been associated with an increased risk of postoperative hypertension possibly due to a direct iatrogenic damage to the carotid sinus fibers. The aim of this study is to assess the long-term effect of the e-CEA on arterial baroreflex and peripheral chemoreflex function in humans. Methods A retrospective review was conducted on a prospectively compiled computerized database of 3128 CEAs performed on 2617 patients at our Center between January 2001 and March 2006. During this period, a total of 292 patients who had bilateral carotid stenosis ≥70% at the time of the first admission underwent staged bilateral CEAs. Of these, 93 patients had staged bilateral e-CEAs, 126 staged bilateral s- CEAs and 73 had different procedures on each carotid. CEAs were performed with either the eversion or the standard technique with routine Dacron patching in all cases. The study inclusion criteria were bilateral CEA with the same technique on both sides and an uneventful postoperative course after both procedures. We decided to enroll patients submitted to bilateral e-CEA to eliminate the background noise from contralateral carotid sinus fibers. Exclusion criteria were: age >70 years, diabetes mellitus, chronic pulmonary disease, symptomatic ischemic cardiac disease or medical therapy with b-blockers, cardiac arrhythmia, permanent neurologic deficits or an abnormal preoperative cerebral CT scan, carotid restenosis and previous neck or chest surgery or irradiation. Young and aged-matched healthy subjects were also recruited as controls. Patients were assessed by the 4 standard cardiovascular reflex tests, including Lying-to-standing, Orthostatic hypotension, Deep breathing, and Valsalva Maneuver. Indirect autonomic parameters were assessed with a non-invasive approach based on spectral analysis of EKG RR interval, systolic arterial pressure, and respiration variability, performed with an ad hoc software. From the analysis of these parameters the software provides the estimates of spontaneous baroreflex sensitivity (BRS). The ventilatory response to hypoxia was assessed in patients and controls by means of classic rebreathing tests. Results A total of 29 patients (16 males, age 62.4±8.0 years) were enrolled. Overall, 13 patients had undergone bilateral e-CEA (44.8%) and 16 bilateral s-CEA (55.2%) with a mean interval between the procedures of 62±56 days. No patient showed signs or symptoms of autonomic dysfunction, including labile hypertension, tachycardia, palpitations, headache, inappropriate diaphoresis, pallor or flushing. The results of standard cardiovascular autonomic tests showed no evidence of autonomic dysfunction in any of the enrolled patients. At spectral analysis, a residual baroreflex performance was shown in both patient groups, though reduced, as expected, compared to young controls. Notably, baroreflex function was better maintained in e-CEA, compared to standard CEA. (BRS at rest: young controls 19.93 ± 2.45 msec/mmHg; age-matched controls 7.75 ± 1.24; e-CEA 13.85 ± 5.14; s-CEA 4.93 ± 1.15; ANOVA P=0.001; BRS at stand: young controls 7.83 ± 0.66; age-matched controls 3.71 ± 0.35; e-CEA 7.04 ± 1.99; s-CEA 3.57 ± 1.20; ANOVA P=0.001). In all subjects ventilation (VÝ E) and oximetry data fitted a linear regression model with r values > 0.8. Oneway analysis of variance showed a significantly higher slope both for ΔVE/ΔSaO2 in controls compared with both patient groups which were not different from each other (-1.37 ± 0.33 compared with -0.33±0.08 and -0.29 ±0.13 l/min/%SaO2, p<0.05, Fig.). Similar results were observed for and ΔVE/ΔPetO2 (-0.20 ± 0.1 versus -0.01 ± 0.0 and -0.07 ± 0.02 l/min/mmHg, p<0.05). A regression model using treatment, age, baseline FiCO2 and minimum SaO2 achieved showed only treatment as a significant factor in explaining the variance in minute ventilation (R2= 25%). Conclusions Overall, we demonstrated that bilateral e-CEA does not imply a carotid sinus denervation. As a result of some expected degree of iatrogenic damage, such performance was lower than that of controls. Interestingly though, baroreflex performance appeared better maintained in e-CEA than in s-CEA. This may be related to the changes in the elastic properties of the carotid sinus vascular wall, as the patch is more rigid than the endarterectomized carotid wall that remains in the e-CEA. These data confirmed the safety of CEA irrespective of the surgical technique and have relevant clinical implication in the assessment of the frequent hemodynamic disturbances associated with carotid angioplasty stenting.
Resumo:
During the last few years, several methods have been proposed in order to study and to evaluate characteristic properties of the human skin by using non-invasive approaches. Mostly, these methods cover aspects related to either dermatology, to analyze skin physiology and to evaluate the effectiveness of medical treatments in skin diseases, or dermocosmetics and cosmetic science to evaluate, for example, the effectiveness of anti-aging treatments. To these purposes a routine approach must be followed. Although very accurate and high resolution measurements can be achieved by using conventional methods, such as optical or mechanical profilometry for example, their use is quite limited primarily to the high cost of the instrumentation required, which in turn is usually cumbersome, highlighting some of the limitations for a routine based analysis. This thesis aims to investigate the feasibility of a noninvasive skin characterization system based on the analysis of capacitive images of the skin surface. The system relies on a CMOS portable capacitive device which gives 50 micron/pixel resolution capacitance map of the skin micro-relief. In order to extract characteristic features of the skin topography, image analysis techniques, such as watershed segmentation and wavelet analysis, have been used to detect the main structures of interest: wrinkles and plateau of the typical micro-relief pattern. In order to validate the method, the features extracted from a dataset of skin capacitive images acquired during dermatological examinations of a healthy group of volunteers have been compared with the age of the subjects involved, showing good correlation with the skin ageing effect. Detailed analysis of the output of the capacitive sensor compared with optical profilometry of silicone replica of the same skin area has revealed potentiality and some limitations of this technology. Also, applications to follow-up studies, as needed to objectively evaluate the effectiveness of treatments in a routine manner, are discussed.
Resumo:
Background. Abdominal porto-systemic collaterals (APSC) on Color-Doppler ultrasound are a frequent finding in portal hypertensive cirrhotic patients. In patients with cirrhosis, an HVPG ≥ 16mmHg has been shown to be associated with increased mortality in two studies. Non-invasive indicators of HVPG ≥ 16 mmHg might define a subgroup of high-risk patients, but data on this aspect are lacking. Aims. We aimed to investigate whether HVPG predicts mortality in patients with clinically significant portal hypertension, and if APSC may predict a severe portal hypertensive state (i.e. HVPG≥16mmHg) in patients with cirrhosis and untreated portal hypertension. Methods. We analysed paired HVPG and ultrasonographic data of 86 untreated portal hypertensive cirrhotic patients. On abdominal echo-color-Doppler data on presence, type and number of APSC were prospectively collected. HVPG was measured following published guidelines. Clinical, laboratory and endoscopic data were available in all cases. First decompensation of cirrhosis and liver-disease related mortality on follow-up (mean 28±20 months) were recorded. Results. 73% of patients had compensated cirrhosis, while 27% were decompensated. All patients had an HVPG≥10 mmHg (mean 17.8±5.1 mmHg). 58% of compensated patients and 82% of decompensated patients had an HVPG over 16 mmHg. 25% had no varices, 28% had small varices, and 47% had medium/large varices. HVPG was higher in patients with esophageal varices vs. patients without varices (19.0±4.8 vs. 14.1±4.2mmHg, p<0.0001), and correlated with Child-Pugh score (R=0.494,p=0.019). 36 (42%) patients had APSC were more frequent in decompensated patients (60% vs. 35%, p=0.03) and in patients with esophageal varices (52% vs. 9%,p=0.001). HVPG was higher in patients with APSC compared with those without PSC (19.9± 4.6 vs. 16.2± 4.9mmHg, p=0.001). The prevalence of APSC was higher in patients with HVPG≥16mmHg vs. those with HVPG<16mmHg (57% vs. 13%,p<0.0001). Decompensation was significantly more frequent in patients with HVPG≥16mmHg vs. HVPG<16mmHg (35.1% vs. 11.5%, p=0.02). On multivariate analysis only HVPG and bilirubin were independent predictors of first decompensation. 10 patients died during follow-up. All had an HVPG≥16 mmHg (26% vs. 0% in patients with HVPG <16mmHg,p=0.04). On multivariate analysis only MELD score and HVPG ≥16mmHg were independent predictors of mortality. In compensated patients the detection of APSC predicted an HVPG≥16mmHg with 92% specificity, 54% sensitivity, positive and negative likelihood ratio 7.03 and 0.50, which implies that the demonstration of APSC on ultrasound increased the probability of HVPG≥16mmHg from 58% to 91%. Conclusions. HVPG maintains an independent prognostic value in the subset of patients with cirrhosis and clinically significant portal hypertension. The presence of APSC is a specific indicator of severe portal hypertension in patients with cirrhosis. Detection of APSC on ultrasound allows the non-invasive identification of a subgroup of compensated patients with bad prognosis, avoiding the invasive measurement of HVPG.
Resumo:
Die Aufklärung von Biosynthesewegen erfolgt häufig mit Hilfe von Fütterungsexperimenten mit radioaktiven oder stabilen Isotopen markierten Präkusoren oder auf der Basis der Enzymreinigung mit anschließender molekularbiologischer Charakterisierung. Die erstgenannte Methode verlangt die Isolierung der Produkte. Jedoch besteht bei Aufarbeitung und Extraktion immer die Gefahr, daß sich der Metabolit teilweise oder vollständig chemisch verändert. Ein weiterer Nachteil der genannten Methoden ist, daß diese generell mühsam und zeitaufwendig sind. Mit Hilfe der in vivo NMR-Spektroskopie können diese Nachteile umgangen werden. In der vorliegenden Arbeit wurden Biotransformationen und Biosynthesesequenzen des Ajmalin-Biosyntheseweges mit Hilfe der in vivo NMR-Spektroskopie in Pflanzenzellkulturen von Rauvolfia serpentina und Rauvolfia serpentina x Rhazya stricta anhand der natürlichen 13C-Häufigkeit untersucht. Dafür wurden ein 700 MHz, 800 MHz und ein 500 MHz CryoProbe Spektrometer eingesetzt, um die Biotransformationen von Isatin-3-oxim und Isatin sowie die Metabolisierungen der Alkaloide Vellosimin, Vinorin, Vomilenin, Ajmalin, Nß-Methyl-dihydrochano-ajmalin und Perakin mit der 1H-13C invers korrelierten NMR-Spektroskopie zu verfolgen.
Resumo:
Monitoring foetal health is a very important task in clinical practice to appropriately plan pregnancy management and delivery. In the third trimester of pregnancy, ultrasound cardiotocography is the most employed diagnostic technique: foetal heart rate and uterine contractions signals are simultaneously recorded and analysed in order to ascertain foetal health. Because ultrasound cardiotocography interpretation still lacks of complete reliability, new parameters and methods of interpretation, or alternative methodologies, are necessary to further support physicians’ decisions. To this aim, in this thesis, foetal phonocardiography and electrocardiography are considered as different techniques. Further, variability of foetal heart rate is thoroughly studied. Frequency components and their modifications can be analysed by applying a time-frequency approach, for a distinct understanding of the spectral components and their change over time related to foetal reactions to internal and external stimuli (such as uterine contractions). Such modifications of the power spectrum can be a sign of autonomic nervous system reactions and therefore represent additional, objective information about foetal reactivity and health. However, some limits of ultrasonic cardiotocography still remain, such as in long-term foetal surveillance, which is often recommendable mainly in risky pregnancies. In these cases, the fully non-invasive acoustic recording, foetal phonocardiography, through maternal abdomen, represents a valuable alternative to the ultrasonic cardiotocography. Unfortunately, the so recorded foetal heart sound signal is heavily loaded by noise, thus the determination of the foetal heart rate raises serious signal processing issues. A new algorithm for foetal heart rate estimation from foetal phonocardiographic recordings is presented in this thesis. Different filtering and enhancement techniques, to enhance the first foetal heart sounds, were applied, so that different signal processing techniques were implemented, evaluated and compared, by identifying the strategy characterized on average by the best results. In particular, phonocardiographic signals were recorded simultaneously to ultrasonic cardiotocographic signals in order to compare the two foetal heart rate series (the one estimated by the developed algorithm and the other provided by cardiotocographic device). The algorithm performances were tested on phonocardiographic signals recorded on pregnant women, showing reliable foetal heart rate signals, very close to the ultrasound cardiotocographic recordings, considered as reference. The algorithm was also tested by using a foetal phonocardiographic recording simulator developed and presented in this research thesis. The target was to provide a software for simulating recordings relative to different foetal conditions and recordings situations and to use it as a test tool for comparing and assessing different foetal heart rate extraction algorithms. Since there are few studies about foetal heart sounds time characteristics and frequency content and the available literature is poor and not rigorous in this area, a data collection pilot study was also conducted with the purpose of specifically characterising both foetal and maternal heart sounds. Finally, in this thesis, the use of foetal phonocardiographic and electrocardiographic methodology and their combination, are presented in order to detect foetal heart rate and other functioning anomalies. The developed methodologies, suitable for longer-term assessment, were able to detect heart beat events correctly, such as first and second heart sounds and QRS waves. The detection of such events provides reliable measures of foetal heart rate, potentially information about measurement of the systolic time intervals and foetus circulatory impedance.
Resumo:
Diabetes mellitus umfasst eine heterogene Gruppe von Stoffwechselfunktionsstörungen, die durch hohe Blut-Glukose-Werte gekennzeichnet sind. Zwei Haupttypen von Diabetes mellitus wurden definiert: Typ 1- und Typ 2-Diabetes. Repaglinid ist ein neuer, schnell wirksamer, bei Typ 2-Diabetikern eingesetzter prandialer Glukose-Regulator mit einer kurzen Plasmahalbwertszeit (<1 Stunde) und der erste Vertreter der Carbamoylmethylbenzoesäure Familie, der in klinischen Studien getestet wurde. Die 18F- und 11C-markierten Repaglinid-Derivate (S)-2-(2-[18F]Fluorethoxy)-4-((3-methyl-1-(2-piperidin-1-yl-phenyl)-butylcarbamoyl)-methyl)-benzoesäure ([18F]Fluorethoxy-desethoxy-Repaglinid) und (S)-2-([11C]Methoxy)-4-([3-methyl-1-(2-piperidin-1-yl-phenyl)-butyl-carba-moyl]-benzoesäure ([11C]Methoxy-desethoxy-Repaglinid) wurden als potentielle Tracer für die nicht-invasive Quantifizierung des Sulfonylharnstoffrezeptor-Typ1-Status (SUR-1) der Insulin-sezernierenden -Zellen mittels Positronen-Emissions-Tomographie (PET) synthetisiert. [18F]Fluorethoxy-desethoxy-Repaglinide konnte in einer radiochemischen Ausbeute (RCA) von 20% nach 135 Minuten mit einer radiochemischen Reinheit >98% unter Verwendung des sekundären Markierungsvorläufers 2-[18F]Fluorethyltosylat erhalten werden. Die spezifische Aktivität lag im Bereich von 50-60 GBq/µmol. Für die radioaktive Synthese des [11C]Methoxy-desethoxy-Repaglinids wurde der sekundäre Markierungsvorläufer [11C]Methyliodid verwendet. Der 11C-Radiotracer wurde in einer RCA von 35% (bezogen auf [11C]CO2) mit einer spezifischen Aktivität von 40-70 GBq/µmol erhalten. Um die Eigenschaften des fluorierten sowie des methoxylierten Repaglinids zu charakterisieren, wurde die Affinität beider Verbindungen zum humanen SUR-1 evaluiert. [19F]Fluorethoxy-desethoxy-Repaglinid und Methoxy-desethoxy-Repaglinid induzierten Verdrängungskurven mit Hill-Koeffizienten nahe 1 und ergaben Dissotiationskonstanten (KD) von 142 nM beziehungsweise 83 nM - vergleichsweise geringe Verluste relativ zu Original-Repaglinid. Die biologische Aktivität wurde mittels Insulin-Sekretionstests an isolierten Ratten-Inselzellen gezeigt und war ebenfalls mit der des Repaglinids vergleichbar. Schließlich wurde die Biodistribution des [18F]Fluorethoxy-desethoxy-Repaglinids in gesunden Sprague-Dawley-Ratten durch Messung der Konzentration der Verbindung in verschiedenen Organen nach intravenöser Injektion untersucht. Das pankreatische Gewebe zeigte im Zeitintervall zwischen 10 und 30 Minuten nach Injektion eine stabile Akkumulation von etwa 0.12% der injizierten Dosis. 50% dieser Tracer-Akkulmulation konnten durch zusätzliche Injektion von nicht-radioaktiv-markiertem Repaglinid verdrängt werden, was auf eine mögliche Eignung des [18F]Fluorethoxy-desethoxy-Repaglinids für in vivo-Untersuchungen mittels PET schließen lässt. Eine erste humane PET-Studie zeigte zwar ebenfalls eine stabile, allerdings nur geringere Akkumulation von [18F]Fluorethoxy-desethoxy-Repaglinid im Pankreas und eine überproportional hohe Aktivitätsanreicherung in der Leber. Die Radioaktivitäts-akkumulation im Blut fiel nach wenigen Minuten unter die des Pankreas.
Resumo:
Background and aims: Sorafenib is the reference therapy for advanced Hepatocellular Carcinoma (HCC). No method exists to predict in the very early period subsequent individual response. Starting from the clinical experience in humans that subcutaneous metastases may rapidly change consistency under sorafenib and that elastosonography a new ultrasound based technique allows assessment of tissue stiffness, we investigated the role of elastonography in the very early prediction of tumor response to sorafenib in a HCC animal model. Methods: HCC (Huh7 cells) subcutaneous xenografting in mice was utilized. Mice were randomized to vehicle or treatment with sorafenib when tumor size was 5-10 mm. Elastosonography (Mylab 70XVG, Esaote, Genova, Italy) of the whole tumor mass on a sagittal plane with a 10 MHz linear transducer was performed at different time points from treatment start (day 0, +2, +4, +7 and +14) until mice were sacrified (day +14), with the operator blind to treatment. In order to overcome variability in absolute elasticity measurement when assessing changes over time, values were expressed in arbitrary units as relative stiffness of the tumor tissue in comparison to the stiffness of a standard reference stand-off pad lying on the skin over the tumor. Results: Sor-treated mice showed a smaller tumor size increase at day +14 in comparison to vehicle-treated (tumor volume increase +192.76% vs +747.56%, p=0.06). Among Sor-treated tumors, 6 mice showed a better response to treatment than the other 4 (increase in volume +177% vs +553%, p=0.011). At day +2, median tumor elasticity increased in Sor-treated group (+6.69%, range –30.17-+58.51%), while decreased in the vehicle group (-3.19%, range –53.32-+37.94%) leading to a significant difference in absolute values (p=0.034). From this time point onward, elasticity decreased in both groups, with similar speed over time, not being statistically different anymore. In Sor-treated mice all 6 best responders at day 14 showed an increase in elasticity at day +2 (ranging from +3.30% to +58.51%) in comparison to baseline, whereas 3 of the 4 poorer responders showed a decrease. Interestingly, these 3 tumours showed elasticity values higher than responder tumours at day 0. Conclusions: Elastosonography appears a promising non-invasive new technique for the early prediction of HCC tumor response to sorafenib. Indeed, we proved that responder tumours are characterized by an early increase in elasticity. The possibility to distinguish a priori between responders and non responders based on the higher elasticity of the latter needs to be validated in ad-hoc experiments as well as a confirmation of our results in humans is warranted.
Resumo:
Negli ultimi anni si è assistito ad una radicale rivoluzione nell’ambito dei dispositivi di interazione uomo-macchina. Da dispositivi tradizionali come il mouse o la tastiera si è passati allo sviluppo di nuovi sistemi capaci di riconoscere i movimenti compiuti dall’utente (interfacce basate sulla visione o sull’uso di accelerometri) o rilevare il contatto (interfacce di tipo touch). Questi sistemi sono nati con lo scopo di fornire maggiore naturalezza alla comunicazione uomo-macchina. Le nuove interfacce sono molto più espressive di quelle tradizionali poiché sfruttano le capacità di comunicazione naturali degli utenti, su tutte il linguaggio gestuale. Essere in grado di riconoscere gli esseri umani, in termini delle azioni che stanno svolgendo o delle posture che stanno assumendo, apre le porte a una serie vastissima di interessanti applicazioni. Ad oggi sistemi di riconoscimento delle parti del corpo umano e dei gesti sono ampiamente utilizzati in diversi ambiti, come l’interpretazione del linguaggio dei segni, in robotica per l’assistenza sociale, per indica- re direzioni attraverso il puntamento, nel riconoscimento di gesti facciali [1], interfacce naturali per computer (valida alternativa a mouse e tastiera), ampliare e rendere unica l’esperienza dei videogiochi (ad esempio Microsoft 1 Introduzione Kinect© e Nintendo Wii©), nell’affective computing1 . Mostre pubbliche e musei non fanno eccezione, assumendo un ruolo cen- trale nel coadiuvare una tecnologia prettamente volta all’intrattenimento con la cultura (e l’istruzione). In questo scenario, un sistema HCI deve cercare di coinvolgere un pubblico molto eterogeneo, composto, anche, da chi non ha a che fare ogni giorno con interfacce di questo tipo (o semplicemente con un computer), ma curioso e desideroso di beneficiare del sistema. Inoltre, si deve tenere conto che un ambiente museale presenta dei requisiti e alcune caratteristiche distintive che non possono essere ignorati. La tecnologia immersa in un contesto tale deve rispettare determinati vincoli, come: - non può essere invasiva; - deve essere coinvolgente, senza mettere in secondo piano gli artefatti; - deve essere flessibile; - richiedere il minor uso (o meglio, la totale assenza) di dispositivi hardware. In questa tesi, considerando le premesse sopracitate, si presenta una sistema che può essere utilizzato efficacemente in un contesto museale, o in un ambiente che richieda soluzioni non invasive. Il metodo proposto, utilizzando solo una webcam e nessun altro dispositivo personalizzato o specifico, permette di implementare i servizi di: (a) rilevamento e (b) monitoraggio dei visitatori, (c) riconoscimento delle azioni.
Resumo:
Eine häufige Art der Chemotherapie ist die Behandlung von Tumoren mit alkylierenden oder chloralkylierenden Zytostatika, die eine Alkylierung von Guanin in der DNA verursachen. Daraus resultieren eine Blockierung der DNA-Synthese und ein Rückgang im Tumorwachstum. Das Enzym O6-Methylguanin-DNA-methyltransferase (MGMT) ist in der Lage, solche Schäden zu reparieren. Da MGMT auch in verschiedenen Tumorarten exprimiert wird, eine Tatsache, die therapeutische Effekte verringern könnte, wird zur Zeit die Gabe von Inhibitoren der MGMT, wie O6-Benzylguanin, vor der eigentlichen Chemotherapie untersucht. Um möglicher Weise die Selektivität dieser Verbindungen für Tumor- vs. gesundem Gewebe und auch die in vivo-Eigenschaften zu verbessern, wurden glycosylierte Inhibitoren vorgeschlagen. Für eine Entwicklung neuer MGMT-Inhibitoren wäre es hilfreich, die in vivo Bioverteilung in Tier und Mensch durch eine Markierung mit geeigneten Isotopen verfolgen zu können. Im Moment existiert keine Möglichkeit, den MGMT-Status eines Tumors nicht-invasiv zu visualisieren. Diese Information kann sehr wichtig für die Planung einer Chemotherapie mit alkylierenden oder chloralkylierenden Zytostatika sein. Mit Methoden wie der Positronen-Emissions-Tomographie (PET) oder der Einzel-Photonen-Emissions-Tomographie (SPECT) ist eine nicht-invasive Quantifizierung von biochemischen Prozessen prinzipiell möglich. Hierfür wurden verschiedenen MGMT-Inhibitoren bereits mit Isotopen wie Fluor-18, Kohlenstoff-11 un Iod-131 markiert, aber sie waren aus unterschiedlichen Gründen nicht geeignet. Das Ziel dieser Arbeit war die Entwicklung von neuen O6-derivatisierten Guaninen, die über einen C8-Spacer an der N9-Position des Guanins mit einer Glucose-Einheit konjugiert werden sollten, geeigneten Markierungsvorläufern und Radioiodierungs-Methoden. Durch Wahl eines geeigneten Radioiodisotops für die Markierung des Restes an der O6-Position des Guanins kann die ex vivo-Bioverteilung dieser Verbindungen in tumortragenden Nacktmäusen (Iod-131) und die Untersuchung der in vivo-Verteilung (Iod-123) durchgeführt werden. Daher wurden O6-(5-Iodothenyl)- (ITG) und O6-(3-Iodbenzyl)guanin-Derivate (IBG) sowie ihre Glucose-Konjugate ITGG und IBGG synthetisiert. Von diesen inaktiven Standard-Verbindungen wurden die IC50-Werte zur MGMT bestimmt. Da sie alle im nM-Bereich lagen, schienen die Verbindungen für weitere Untersuchungen geeignet zu sein. Die Radiomarkierung der Inhibitoren mit Iod-131 bzw. Iod-123 wurde durch Umsetzung der Trialkyl-stannylierten Markierungsvorläufer mit der Chloramin T-Methode in mittleren (Iod-123) bis hohen (Iod-131) radiochemischen Ausbeuten und mit hohen radiochemischen Reinheiten durchgeführt. Mit den 131I-iodierten Verbindungen wurde die spezifische Bindung zur MGMT nachgewiesen, eine Eigenschaft, die essentiell für eine weitere Verwendung dieser Derivate ist. Sie wurden auch zur Bestimmung der ex vivo-Tumor- und Organverteilung in tumortragenden Nacktmäusen (MEX(+), MEX(-), Glioblastom) verwendet. In allen Fällen war die Tumoraufnahme der nicht-konjugierten Guanin-Derivate höher als die der entsprechenden Glucose-Konjugate. Das Tumor-Blut-Verhältnis, das sehr wichtig für einen potentiellen Einsatz der Verbindungen als Tracer des MGMT-Status eines Tumors ist, variierte abhängig von der Kinetik. Zu allen Zeitpunkten war die in vivo-Deiodierung der Glucose-Konjugate deutlich geringer als die von ITG oder IBG. Unter Verwendung von [131I]IBG und [131I]IBGG wurde die Biodistribution nach Inhibition der Natrium-abhängigen Glucose-Transporter, die zumindests teilweise für die Aufnahme der MGMT-Inhibitoren in Zellen verantwortlich sind, durch Phloretin untersucht. Einen Unterschied in der Tumoraufnahme zwischen den mit Phloretin behandelten und den unbehandelten Mäusen konnte nicht beobachtet werden, wahrscheinlich weil die Akkumulation im Tumor generell niedrig war. Mit den 123I-iodierten Verbindungen [123I]IBG und [123I]IBGG wurden in vivo-Scans an tumortragenden Nacktmäusen (MEX(+), MEX(-)) mit einer Kleintier-SPECT-Kamera durchgeführt. In beiden Fällen wurde eine geringe Akkumulation in den Tumoren im Vergleich zu anderen Organen beobachtet, was die ex vivo-Biodistributionsdaten bestätigte.