995 resultados para mobile sensors


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reliable messaging is a key component necessary for mobile agent systems. Current researches focus on reliable one-to-one message delivery to mobile agents. But how to implement a group communication system for mobile agents remains an open issue, which is a powerful block that facilitates the development of fault-tolerant mobile agent systems. In this paper, we propose a group communication system for mobile agents (GCS-MA), which includes totally ordered multicast and membership management functions. We divide a group of mobile agents into several agent clusters,and each agent cluster consists of all mobile agents residing in the same sub-network and is managed by a special module, named coordinator. Then, all coordinators form a ring-based overlay for interchanging messages between clusters. We present a token-based algorithm, an intra-cluster messaging algorithm and an inter-cluster migration algorithm to achieve atomicity and total ordering properties of multicast messages, by building a membership protocol on top of the clustering and failure detection mechanisms. Performance issues of the proposed system have been analysed through simulations. We also describe the application of the proposed system in the context of the service cooperation middleware (SCM) project.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

新的计算模式,普适计算和全局计算,正在作为高度分布式和移动计算的计算模式展现出来。这篇论文探讨了在抽象层面上支持这些新型计算模式的适合的形式化基础,关注在进程移动单位上的控制, 以便在分布式与移动计算环境下更好地协调进程的移动性。 论文的第一部分概述了针对分布式、移动计算的现有进程演算模型中的进程移动单元,并且设计了一种在此方面更优、更具弹性的进程框架。为了表示这种进程框架,我们提出了一种新的、针对移动和分布式系统的进程演算,这种进程演算的优点是动态、弹性的控制进程的移动单元;具体的思路就是扩展π- calculus以及其支持分布式和移动性的变体。我们把这种新的演算叫做Modular π-calculus。我们通过这种演算的提出来说明进程框架提供了一种针对移动进程更为合适的协调机制以及编程模型,例如移动的代理和动态组件载入的支持。之后,我们通过讨论互模拟的几种提法来具体说明能够反映演算设计的进程描述的关键,之后我们讨论了它们的具体性质。 本文的第二部分提出了一个对进程模型的行为和性质进行推理的规约框架。首先,提出了一个对Modularπ-calculus中进程的系统性质进行规约的模态逻辑。为了更好的理解该逻辑,文中对由这个逻辑推出的进程等价的特征进行了研究,并且证明了该逻辑的区分能力介于互模拟和结构一致之间。接下来关于这个规约框架的自动化,本文针对该逻辑和Modular π-calculus的有限控制子集,提出了模型检测算法,并且给出了算法正确性的证明。同时文中贯穿了一些实际且直观的例子,以展现本文提出的一组框架即演算、逻辑和模型算法的有效性。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The determination of glucose is possible with the enzymatic reaction of glucose oxidase and potentiometric detection. The signal is proportional to the concentration up to 50 mg/dl. This value is fixed by the concentration of oxygen in the sample. By adding catalase, concentrations up to 2000 mg/dl are detectable. The steepness of the calibration curve is not affected by oxygen concentrations greater than 4 mg/l. In contrast to amperometric sensors, an influence of deposits on the electrodes surface on the signal cannot be found with potentiometric sensors

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Schiff base compounds refer to the branch of supra-molecules and can be used as sensing material in the construction of potentiometric ion selective electrodes (ISEs). This relatively modern field has been subject to extensive research in the period of 1999-2007 when more than 100 ISEs employing Schiff bases were constructed. The quantitative high-throughput detection of 29 cations and 7 anions has been demonstrated in various scientific branches, such as biomedicine, pharmacy, biochemistry, pharmacology, environmental chemistry, food technology, and agriculture. This review discusses Schiff base compounds and their applications in the design and development of ion selective sensors and microsensors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thiosemicarbazone derivatives have been used as ion carriers for the preparation of PVC-matrix based mercury(II)-selective membrane sensors. The electrodes give near-Nernstian responses in the linear concentration range of 1.0×10-1-5.0×10-6 M with detection limits of the order of 10-6 M. The stable potentiometric signals are obtained within a short time period of 20-25s. The effect of different plasticizers has been studied and dioctylsebacate (DOS) found to give a better response in comparison to other plasticizers. Selectivity coefficient values (log KPotHg,M) have been evaluated using fixed interference method. Better selectivity for mercury(II) ions is observed over many of the monovalent (Na+, K+ and NH4+) and divalent ions (Mg2+, Ca2+, Zn2+, Pb2+, Ni2+, Co2+, etc.). The sensors have also been used as indicator electrodes in potentiometric titration of mercury(II) ions with EDTA and its determination in synthetic water samples.