922 resultados para microvascular blood flow


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Treatment of carotid artery stenosis decreases the long-term risk of stroke and may enhance cerebral blood flow. It is therefore expected to have the potential to prevent cognitive decline or even improve cognition over the long-term. However, intervention itself can cause peri-interventional cerebral infarcts, possibly resulting in a decline of cognitive performance, at least for a short time. We investigated the long-term effects of three treatment methods on cognition and the emotional state one year after intervention. In this prospective observational cohort study, 58 patients with extracranial carotid artery stenosis (≥70%) underwent magnetic resonance imaging and assessment of cognition, mood and motor speed before carotid endarterectomy (n = 20), carotid stenting (n = 10) or best medical treatment (n = 28) (i.e., time-point 1 [TP1]), and at one-year follow-up (TP2). Gain scores, reflecting cognitive change after treatment, were built according to performance as (TP2 -TP1)/TP1. Independent of the treatment type, significant improvement in frontal lobe functions, visual memory and motor speed was found. Performance level, motor speed and mood at TP1 were negatively correlated with gain scores, with greater improvement in patients with low performance before treatment. Active therapy, whether conservative or interventional, produces significant improvement of frontal lobe functions and memory in patients with carotid artery disease, independent of treatment type. This effect was particularly pronounced in patients with low cognitive performance prior to treatment.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND It is unclear how complex pathophysiological mechanisms that result in early brain injury (EBI) after subarachnoid hemorrhage (SAH) are triggered. We investigate how peak intracranial pressure (ICP), amount of subarachnoid blood, and hyperacute depletion of cerebral perfusion pressure (CPP) correlate to the onset of EBI following experimental SAH. METHODS An entire spectrum of various degrees of SAH severities measured as peak ICP was generated and controlled using the blood shunt SAH model in rabbits. Standard cardiovascular monitoring, ICP, CPP, and bilateral regional cerebral blood flow (rCBF) were continuously measured. Cells with DNA damage and neurodegeneration were detected using terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL) and Fluoro-jade B (FJB). RESULTS rCBF was significantly correlated to reduction in CPP during the initial 15 min after SAH in a linear regression pattern (r (2) = 0.68, p < 0.001). FJB- and TUNEL-labeled cells were linearly correlated to reduction in CPP during the first 3 min of hemorrhage in the hippocampal regions (FJB: r (2) = 0.50, p < 0.01; TUNEL: r (2) = 0.35, p < 0.05), as well as in the basal cortex (TUNEL: r (2) = 0.58, p < 0.01). EBI occurred in animals with severe (relative CPP depletion >0.4) and moderate (relative CPP depletion >0.25 but <0.4) SAH. Neuronal cell death was equally detected in vulnerable and more resistant brain regions. CONCLUSIONS The degree of EBI in terms of neuronal cell degeneration in both the hippocampal regions and the basal cortex linearly correlates with reduced CPP during hyperacute SAH. Temporary CPP reduction, however, is not solely responsible for EBI but potentially triggers processes that eventually result in early brain damage.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND Brain dysfunction is common in sepsis. We aimed to assess whether cerebral perfusion, oxygenation, and/or metabolism are abnormal during early endotoxemia, and how they may relate to potential neurohistological changes. METHODS In this prospective animal study, we included 12 pigs (weight: 42 ± 4 kg; mean ± SD) that were exposed to Escherichia coli lipopolysaccharide (E. coli LPS B0111 : B4, 0.4 μg/kg/h) or saline infusion (n = 6, each) for 10 h. Systemic hemodynamics, cerebral blood flow, intracranial pressure, and brain tissue oxygen tension were continuously measured. At the end of the experiment, formalin-fixed brains were cut in coronal sections and embedded in paraffin. Afterwards, the sections were cut at 5 microns and stained with hematoxylin and eosin. RESULTS Stable systemic hemodynamics in both groups were associated with higher carotid arterial blood flow after 10 h of endotoxemia (9.0 ± 2.2 ml/kg/min) compared to controls (6.6 ± 1.2 ml/kg/min; time-group interaction: P = 0.014). Intracranial pressure, cerebral perfusion pressure, brain oxygen consumption, and brain tissue oxygen tension were similar in both groups. In four of the six endotoxemic animals but in none of the controls, cerebral tissue lesions were found (encephalomalacia with spongy degeneration of white matter, axonal swelling, and ischemic neuronal thalamic necrosis), including significant venous vascular alterations, predominantly in the brainstem, in three of the four animals. CONCLUSIONS Early endotoxemia seems to be associated with histological signs of brain damage unrelated to systemic or cerebral hemodynamics or oxygenation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Nitinol stent oversizing is frequently performed in peripheral arteries to ensure a desirable lumen gain. However, the clinical effect of mis-sizing remains controversial. The goal of this study was to provide a better understanding of the structural and hemodynamic effects of Nitinol stent oversizing. Five patient-specific numerical models of non-calcified popliteal arteries were developed to simulate the deployment of Nitinol stents with oversizing ratios ranging from 1.1 to 1.8. In addition to arterial biomechanics, computational fluid dynamics methods were adopted to simulate the physiological blood flow inside the stented arteries. Results showed that stent oversizing led to a limited increase in the acute lumen gain, albeit at the cost of a significant increase in arterial wall stresses. Furthermore, localized areas affected by low Wall Shear Stress increased with higher oversizing ratios. Stents were also negatively impacted by the procedure as their fatigue safety factors gradually decreased with oversizing. These adverse effects to both the artery walls and stents may create circumstances for restenosis. Although the ideal oversizing ratio is stent-specific, this study showed that Nitinol stent oversizing has a very small impact on the immediate lumen gain, which contradicts the clinical motivations of the procedure.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE The posterior circulation Acute Stroke Prognosis Early CT Score (pc-APECTS) applied to CT angiography source images (CTA-SI) predicts the functional outcome of patients in the Basilar Artery International Cooperation Study (BASICS). We assessed the diagnostic and prognostic impact of pc-ASPECTS applied to perfusion CT (CTP) in the BASICS registry population. METHODS We applied pc-ASPECTS to CTA-SI and cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT) parameter maps of BASICS patients with CTA and CTP studies performed. Hypoattenuation on CTA-SI, relative reduction in CBV or CBF, or relative increase in MTT were rated as abnormal. RESULTS CTA and CTP were available in 27/592 BASICS patients (4.6%). The proportion of patients with any perfusion abnormality was highest for MTT (93%; 95% confidence interval [CI], 76%-99%), compared with 78% (58%-91%) for CTA-SI and CBF, and 46% (27%-67%) for CBV (P < .001). All 3 patients with a CBV pc-ASPECTS < 8 compared to 6/23 patients with a CBV pc-ASPECTS ≥ 8 had died at 1 month (RR 3.8; 95% CI, 1.9-7.6). CONCLUSION CTP was performed in a minority of the BASICS registry population. Perfusion disturbances in the posterior circulation were most pronounced on MTT parameter maps. CBV pc-ASPECTS < 8 may indicate patients with high case fatality.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The coronary collateral circulation provides an alternative source of blood supply to myocardium jeopardised by ischaemia. Collaterals enlarge with obstructive coronary artery disease to allow bulk flow, but blood flow deliverable by the native, pre-formed collateral extent can already be sizeable. Genetic determinants contribute significantly to the wide variability observed in both native collateral extent and its capacity to enlarge, and the severity of the coronary stenosis is the most significant environmental determinant for collateral enlargement. The protective effect of a well-developed coronary collateral circulation translates into relevant improvements in all-cause and cardiac mortality in the acute and chronic phases of coronary artery disease, as well as into a reduction of future adverse cardiovascular events.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Maternal thromboembolism and a spectrum of placenta-mediated complications including the pre-eclampsia syndromes, fetal growth restriction, fetal loss, and abruption manifest a shared etiopathogenesis and predisposing risk factors. Furthermore, these maternal and fetal complications are often linked to subsequent maternal health consequences that comprise the metabolic syndrome, namely, thromboembolism, chronic hypertension, and type II diabetes. Traditionally, several lines of evidence have linked vasoconstriction, excessive thrombosis and inflammation, and impaired trophoblast invasion at the uteroplacental interface as hallmark features of the placental complications. "Omic" technologies and biomarker development have been largely based upon advances in vascular biology, improved understanding of the molecular basis and biochemical pathways responsible for the clinically relevant diseases, and increasingly robust large cohort and/or registry based studies. Advances in understanding of innate and adaptive immunity appear to play an important role in several pregnancy complications. Strategies aimed at improving prediction of these pregnancy complications are often incorporating hemodynamic blood flow data using non-invasive imaging technologies of the utero-placental and maternal circulations early in pregnancy. Some evidence suggests that a multiple marker approach will yield the best performing prediction tools, which may then in turn offer the possibility of early intervention to prevent or ameliorate these pregnancy complications. Prediction of maternal cardiovascular and non-cardiovascular consequences following pregnancy represents an important area of future research, which may have significant public health consequences not only for cardiovascular disease, but also for a variety of other disorders, such as autoimmune and neurodegenerative diseases.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

INTRODUCTION: Hemodynamic parameters in zebrafish receive increasing attention because of their important role in cardiovascular processes such as atherosclerosis, hematopoiesis, sprouting and intussusceptive angiogenesis. To study underlying mechanisms, the precise modulation of parameters like blood flow velocity or shear stress is centrally important. Questions related to blood flow have been addressed in the past in either embryonic or ex vivo-zebrafish models but little information is available for adult animals. Here we describe a pharmacological approach to modulate cardiac and hemodynamic parameters in adult zebrafish in vivo. MATERIALS AND METHODS: Adult zebrafish were paralyzed and orally perfused with salt water. The drugs isoprenaline and sodium nitroprusside were directly applied with the perfusate, thus closely resembling the preferred method for drug delivery in zebrafish, namely within the water. Drug effects on the heart and on blood flow in the submental vein were studied using electrocardiograms, in vivo-microscopy and mathematical flow simulations. RESULTS: Under control conditions, heart rate, blood flow velocity and shear stress varied less than ± 5%. Maximal chronotropic effects of isoprenaline were achieved at a concentration of 50 μmol/L, where it increased the heart rate by 22.6 ± 1.3% (n = 4; p < 0.0001). Blood flow velocity and shear stress in the submental vein were not significantly increased. Sodium nitroprusside at 1 mmol/L did not alter the heart rate but increased blood flow velocity by 110.46 ± 19.64% (p = 0.01) and shear stress by 117.96 ± 23.65% (n = 9; p = 0.03). DISCUSSION: In this study, we demonstrate that cardiac and hemodynamic parameters in adult zebrafish can be efficiently modulated by isoprenaline and sodium nitroprusside. Together with the suitability of the zebrafish for in vivo-microscopy and genetic modifications, the methodology described permits studying biological processes that are dependent on hemodynamic alterations.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The present synopsis aims to integrate one study about memory training in very preterm-born children and two studies about cognition in patients with carotid artery stenosis before and after treatments. Preterm-born children are at increased risk of cognitive deficits and behavioural problems compared with peers born at term. This thesis determined whether memory training would improve cognitive functions in school-age very preterm-born children. Memory strategy training produced significant improvements in trained and non-trained cognitive functions; a core working memory training revealed significant effects on short-term memory and working memory tasks. Six months after training, children in both training groups showed better working memory performance than children in the waiting control group. This is evidence that memory training – an external influence on cognition – induces plastic changes in very preterm-born children. Patients with carotid artery stenosis are known to be at increased risk of cognitive impairment. We showed that patients with symptomatic or asymptomatic carotid artery stenosis were at higher risk for cognitive deficits than expected in a normative sample. This thesis seeks to link cognitive plasticity to internal factors like carotid stenosis. An external factor, which influences blood flow to the brain is the nature of the carotid artery stenosis treatment. Research on the effects of carotid artery stenosis treatment on cognition has produced inconsistent results. We found significant improvement in frontal lobe functions, visual memory and motor speed one year after treatment independent of the treatment type (best medical treatment, carotid artery stenting, carotid artery endarterectomy); providing evidence for ‘treatment-induced’ cognitive plasticity. Baseline performance was negatively associated with improvement in various cognitive functions after training in very preterm-born children and after treatment in patients with carotid artery stenosis. The present synopsis aims to integrate these findings into the current and relevant literature, and discuss consequences as well as methodological considerations resulting from the studies constituting the thesis at hand.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Cardiac pacemakers are routinely used for the treatment of bradyarrhythmias. Contemporary pacemakers are reliable and allow for a patient specific programming. However, pacemaker replacements due to battery depletion are common (~25 % of all implantation procedures) and bear the risk of complications. Batteryless pacemakers may allow overcoming this limitation. To power a batteryless pacemaker, a mechanism for intracorporeal energy harvesting is required. Such a generator may consist out of subcutaneously implanted solar cells, transforming the small amount of transcutaneously available light into electrical energy. Alternatively, intravascular turbines may harvest energy from the blood flow. Energy may also be harvested from the ventricular wall motion by a dedicated mechanical clockwork converting motion into electrical energy. All these approaches have successfully been tested in vivo. Pacemaker leads constitute another Achilles heel of contemporary pacemakers. Thus, leadless devices are desired. Miniaturized pacemaker circuits and suitable energy harvesting mechanisms (incorporated in a single device) may allow catheter-based implantation of the pacemaker in the heart. Such miniaturized battery- and leadless pacemakers would combine the advantages of both approaches and overcome major limitations of today’s systems.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose. The central concepts in pressure ulcer risk are exposure to external pressure caused by inactivity and tissue tolerance to pressure, a factor closely related to blood flow. Inactivity measures are effective in predicting pressure ulcer risk. The purpose of the study is to evaluate whether a physiological measure of skin blood flow improves pressure ulcer risk prediction. Skin temperature regularity and self-similarity, as proxy measures of blood flow, and not previously described, may be undefined pressure ulcer risk factors. The specific aims were to determine whether a sample of nursing facility residents at high risk of pressure ulcers classified using the Braden Scale for Pressure Sore Risk© differ from a sample of low risk residents according to (1) exposure to external pressure as measured by resident activity, (2) tissue tolerance to external pressure as measured by skin temperature, and (3) skin temperature fluctuations and recovery in response to a commonly occurring stressor, bathing and additionally whether (4) scores on the Braden Scale mobility subscale score are related to entropy and the spectral exponent. ^ Methods. A two group observational time series design was used to describe activity and skin temperature regularity and self-similarity, calculating entropy and the spectral exponent using detrended fluctuation analysis respectively. Twenty nursing facility residents wore activity and skin temperature monitors for one week. One bathing episode was observed as a commonly occurring stressor for skin temperature.^ Results. Skin temperature multiscale entropy (MSE), F(1, 17) = 5.55, p = .031, the skin temperature spectral exponent, F(1, 17) = 6.19, p = .023, and the activity mean MSE, F(1, 18) = 4.52, p = .048 differentiated the risk groups. The change in skin temperature entropy during bathing was significant, t(16) = 2.55, p = .021, (95% CI, .04-.40). Multiscale entropy for skin temperature was lowest in those who developed pressure ulcers, F(1, 18) = 35.14, p < .001.^ Conclusions. This study supports the tissue tolerance component of the Braden and Bergstrom conceptual framework and shows differences in skin temperature multiscale entropy between pressure ulcer risk categories, pressure ulcer outcome, and during a commonly occurring stressor. ^

Relevância:

80.00% 80.00%

Publicador:

Resumo:

La reperfusión, luego de un período de isquemia miocárdica breve, puede desencadenar un daño paradojal, dentro del cual, se destacan las arritmias ventriculares. Existen estudios que reportan un efecto beneficioso del ácido acetilsalicílico (AAS) a nivel cardiovascular, pero se desconocen los efectos electrofisiológicos en el proceso de injuria por isquemia/reperfusión. El objetivo de este estudio es evaluar las propiedades electrofisiológicas del AAS, en especial si puede evitar las arritmias de reperfusión (AR) en forma independiente de su efecto antiplaquetario. Se trabajó con corazones aislados de rata Sprague Dawley según la técnica de Langendorff sometidos a 10 minutos de isquemia regional. Se realizaron 3 series esperimentales: 1) control (C, n=10); 2) , corazones perfundidos durante todo el protocolo con AAS 0.14 mM (AAS, n=10) y 3) corazones que recibieron la misma dosis de AAS sólo en los 3 primeros minutos de la reperfusión (AASR, n=9). Se analizaron la incidencia y severidad de las AR y su relación con el ECG y los potenciales de acción registrados simultáneamente. El 82% del grupo control presentó AR sostenidas, el 30 % con AAS y el 22% con AASR (ambas p<0.05 por χ2). En la reperfusión se observó que luego de los primeros tres minutos la duración del potencial de acción (DPA) fue mayor en el grupo AASR (81,5 ± 23,1) que en el grupo AAS (55,2 ± 10,0) p<0.05 por ANOVA I. Por lo tanto, la menor incidencia de AR en los grupos tratados podría asociarse al efecto de la aspirina sobre la DPA y que la droga estudiada tendría efectos sobre esta variable sólo al momento de reperfusión.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Comparación de los esquemas de integración temporal explícito e implícito, en la simulación del flujo sanguíneo y su interacción con la pared arterial. There are two major strategies in FSI coupling techniques: implicit and explicit. The general difference between these methodologies is how many times the data is exchanged between the fluid and solid domains at each FSI time-step. In both coupling strategies, the pressure values coming from fluid domain calculations at each time-step are exported to the solid domain, and consequently, the solid domain is analyzed with these imported forces. In contrast to the explicit coupling, in the implicit approach the fluid and solid domain’s data is exchanged several times until the convergence is achieved. Although this method may boost the numerical stabilization, it increases the computational cost due to the extra data exchanges. In cardiovascular simulations, depending on the analysis objectives, one may choose an explicit or implicit approach. In the current work, the advantage of an explicit coupling strategy is highlighted when simulation of pulsatile blood flow in elastic arteries is desired.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

La tomografía axial computerizada (TAC) es la modalidad de imagen médica preferente para el estudio de enfermedades pulmonares y el análisis de su vasculatura. La segmentación general de vasos en pulmón ha sido abordada en profundidad a lo largo de los últimos años por la comunidad científica que trabaja en el campo de procesamiento de imagen; sin embargo, la diferenciación entre irrigaciones arterial y venosa es aún un problema abierto. De hecho, la separación automática de arterias y venas está considerado como uno de los grandes retos futuros del procesamiento de imágenes biomédicas. La segmentación arteria-vena (AV) permitiría el estudio de ambas irrigaciones por separado, lo cual tendría importantes consecuencias en diferentes escenarios médicos y múltiples enfermedades pulmonares o estados patológicos. Características como la densidad, geometría, topología y tamaño de los vasos sanguíneos podrían ser analizados en enfermedades que conllevan remodelación de la vasculatura pulmonar, haciendo incluso posible el descubrimiento de nuevos biomarcadores específicos que aún hoy en dípermanecen ocultos. Esta diferenciación entre arterias y venas también podría ayudar a la mejora y el desarrollo de métodos de procesamiento de las distintas estructuras pulmonares. Sin embargo, el estudio del efecto de las enfermedades en los árboles arterial y venoso ha sido inviable hasta ahora a pesar de su indudable utilidad. La extrema complejidad de los árboles vasculares del pulmón hace inabordable una separación manual de ambas estructuras en un tiempo realista, fomentando aún más la necesidad de diseñar herramientas automáticas o semiautomáticas para tal objetivo. Pero la ausencia de casos correctamente segmentados y etiquetados conlleva múltiples limitaciones en el desarrollo de sistemas de separación AV, en los cuales son necesarias imágenes de referencia tanto para entrenar como para validar los algoritmos. Por ello, el diseño de imágenes sintéticas de TAC pulmonar podría superar estas dificultades ofreciendo la posibilidad de acceso a una base de datos de casos pseudoreales bajo un entorno restringido y controlado donde cada parte de la imagen (incluyendo arterias y venas) está unívocamente diferenciada. En esta Tesis Doctoral abordamos ambos problemas, los cuales están fuertemente interrelacionados. Primero se describe el diseño de una estrategia para generar, automáticamente, fantomas computacionales de TAC de pulmón en humanos. Partiendo de conocimientos a priori, tanto biológicos como de características de imagen de CT, acerca de la topología y relación entre las distintas estructuras pulmonares, el sistema desarrollado es capaz de generar vías aéreas, arterias y venas pulmonares sintéticas usando métodos de crecimiento iterativo, que posteriormente se unen para formar un pulmón simulado con características realistas. Estos casos sintéticos, junto a imágenes reales de TAC sin contraste, han sido usados en el desarrollo de un método completamente automático de segmentación/separación AV. La estrategia comprende una primera extracción genérica de vasos pulmonares usando partículas espacio-escala, y una posterior clasificación AV de tales partículas mediante el uso de Graph-Cuts (GC) basados en la similitud con arteria o vena (obtenida con algoritmos de aprendizaje automático) y la inclusión de información de conectividad entre partículas. La validación de los fantomas pulmonares se ha llevado a cabo mediante inspección visual y medidas cuantitativas relacionadas con las distribuciones de intensidad, dispersión de estructuras y relación entre arterias y vías aéreas, los cuales muestran una buena correspondencia entre los pulmones reales y los generados sintéticamente. La evaluación del algoritmo de segmentación AV está basada en distintas estrategias de comprobación de la exactitud en la clasificación de vasos, las cuales revelan una adecuada diferenciación entre arterias y venas tanto en los casos reales como en los sintéticos, abriendo así un amplio abanico de posibilidades en el estudio clínico de enfermedades cardiopulmonares y en el desarrollo de metodologías y nuevos algoritmos para el análisis de imágenes pulmonares. ABSTRACT Computed tomography (CT) is the reference image modality for the study of lung diseases and pulmonary vasculature. Lung vessel segmentation has been widely explored by the biomedical image processing community, however, differentiation of arterial from venous irrigations is still an open problem. Indeed, automatic separation of arterial and venous trees has been considered during last years as one of the main future challenges in the field. Artery-Vein (AV) segmentation would be useful in different medical scenarios and multiple pulmonary diseases or pathological states, allowing the study of arterial and venous irrigations separately. Features such as density, geometry, topology and size of vessels could be analyzed in diseases that imply vasculature remodeling, making even possible the discovery of new specific biomarkers that remain hidden nowadays. Differentiation between arteries and veins could also enhance or improve methods processing pulmonary structures. Nevertheless, AV segmentation has been unfeasible until now in clinical routine despite its objective usefulness. The huge complexity of pulmonary vascular trees makes a manual segmentation of both structures unfeasible in realistic time, encouraging the design of automatic or semiautomatic tools to perform the task. However, this lack of proper labeled cases seriously limits in the development of AV segmentation systems, where reference standards are necessary in both algorithm training and validation stages. For that reason, the design of synthetic CT images of the lung could overcome these difficulties by providing a database of pseudorealistic cases in a constrained and controlled scenario where each part of the image (including arteries and veins) is differentiated unequivocally. In this Ph.D. Thesis we address both interrelated problems. First, the design of a complete framework to automatically generate computational CT phantoms of the human lung is described. Starting from biological and imagebased knowledge about the topology and relationships between structures, the system is able to generate synthetic pulmonary arteries, veins, and airways using iterative growth methods that can be merged into a final simulated lung with realistic features. These synthetic cases, together with labeled real CT datasets, have been used as reference for the development of a fully automatic pulmonary AV segmentation/separation method. The approach comprises a vessel extraction stage using scale-space particles and their posterior artery-vein classification using Graph-Cuts (GC) based on arterial/venous similarity scores obtained with a Machine Learning (ML) pre-classification step and particle connectivity information. Validation of pulmonary phantoms from visual examination and quantitative measurements of intensity distributions, dispersion of structures and relationships between pulmonary air and blood flow systems, show good correspondence between real and synthetic lungs. The evaluation of the Artery-Vein (AV) segmentation algorithm, based on different strategies to assess the accuracy of vessel particles classification, reveal accurate differentiation between arteries and vein in both real and synthetic cases that open a huge range of possibilities in the clinical study of cardiopulmonary diseases and the development of methodological approaches for the analysis of pulmonary images.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In pre-surgery decisions in hospital emergency cases, fast and reliable results of the solid and fluid mechanics problems are of great interest to clinicians. In the current investigation, an iterative process based on a pressure-type boundary condition is proposed in order to reduce the computational costs of blood flow simulations in arteries, without losing control of the important clinical parameters. The incorporation of cardiovascular autoregulation, together with the well-known impedance boundary condition, forms the basis of the proposed methodology. With autoregulation, the instabilities associated with conventional pressure-type or impedance boundary conditions are avoided without an excessive increase in computational costs. The general behaviour of pulsatile blood flow in arteries, which is important from the clinical point of view, is well reproduced through this new methodology. In addition, the interaction between the blood and the arterial walls occurs via a modified weak coupling, which makes the simulation more stable and computationally efficient. Based on in vitro experiments, the hyperelastic behaviour of the wall is characterised and modelled. The applications and benefits of the proposed pressure-type boundary condition are shown in a model of an idealised aortic arch with and without an ascending aorta dissection, which is a common cardiovascular disorder.