847 resultados para lexical unit


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We analyzed an outbreak of invasive infections with an exotoxin U positive Pseudomonas aeruginosa strain within a pediatric oncology care unit. Environmental sampling and molecular characterization of the Pseudomonas aeruginosa strains led to identification of the outbreak source. An errant water jet into the sink within patient rooms was observed. Optimized outbreak management resulted in an abundance of further Pseudomonas aeruginosa infections within the pediatric oncology care unit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The group analysed some syntactic and phonological phenomena that presuppose the existence of interrelated components within the lexicon, which motivate the assumption that there are some sublexicons within the global lexicon of a speaker. This result is confirmed by experimental findings in neurolinguistics. Hungarian speaking agrammatic aphasics were tested in several ways, the results showing that the sublexicon of closed-class lexical items provides a highly automated complex device for processing surface sentence structure. Analysing Hungarian ellipsis data from a semantic-syntactic aspect, the group established that the lexicon is best conceived of being as split into at least two main sublexicons: the store of semantic-syntactic feature bundles and a separate store of sound forms. On this basis they proposed a format for representing open-class lexical items whose meanings are connected via certain semantic relations. They also proposed a new classification of verbs to account for the contribution of the aspectual reading of the sentence depending on the referential type of the argument, and a new account of the syntactic and semantic behaviour of aspectual prefixes. The partitioned sets of lexical items are sublexicons on phonological grounds. These sublexicons differ in terms of phonotactic grammaticality. The degrees of phonotactic grammaticality are tied up with the problem of psychological reality, of how many degrees of this native speakers are sensitive to. The group developed a hierarchical construction network as an extension of the original General Inheritance Network formalism and this framework was then used as a platform for the implementation of the grammar fragments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The aim of the present clinical trial was to evaluate the 12-month success rate of titanium dental implants placed in the posterior mandible and immediately loaded with 3-unit fixed partial dentures. MATERIALS AND METHODS: Patients with missing mandibular premolars and molars were enrolled in this study. To be included in the study, the implants had to show good primary stability. Implant stability was measured with resonance frequency analysis using the Osstell device (Integration Diagnostics). Implants were included in the study when the stability quotient (ISQ) exceeded 62. Clinical measurements, such as width of keratinized tissue, ISQ, and radiographic assessment of peri-implant bone crest levels, were performed at baseline and at the 12-month follow-up. The comparison between the baseline and the 12-month visits was performed with the Student t test for paired data (statistically significant at a level of alpha = 0.05). RESULTS: Forty implants with a sandblasted, large grit, acid-etched (SLA) surface (Straumann) were placed in 20 patients. At 12 months, only 1 implant had been lost because of an acute infection. The remaining 39 implants were successful, resulting in a 1-year success rate of 97.5%. Neither peri-implant bone levels, measured radiographically, nor implant stability changed significantly from baseline to the 12-month follow-up (P > .05). DISCUSSION: The immediate functional loading of implants placed in this case series study resulted in a satisfactory success rate. CONCLUSION: The findings from this clinical study showed that the placement of SLA transmucosal implants in the mandibular area and their immediate loading with 3-unit fixed partial dentures may be a safe and successful procedure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Family needs and expectations are often unmet in the intensive care unit (ICU), leading to dissatisfaction. This study assesses cross-cultural adaptability of an instrument evaluating family satisfaction in the ICU. MATERIALS AND METHODS: A Canadian instrument on family satisfaction was adapted for German language and central European culture and then validated for feasibility, validity, internal consistency, reliability, and sensitivity. RESULTS: Content validity of a preliminary translated version was assessed by staff, patients, and next of kin. After adaptation, content and comprehensibility were considered good. The adapted translation was then distributed to 160 family members. The return rate was 71.8%, and 94.4% of questions in returned forms were clearly answered. In comparison with a Visual Analogue Scale, construct validity was good for overall satisfaction with care (Spearman rho = 0.60) and overall satisfaction with decision making (rho = 0.65). Cronbach alpha was .95 for satisfaction with care and .87 for decision-making. Only minor differences on repeated measurements were found for interrater and intrarater reliability. There was no floor or ceiling effect. CONCLUSIONS: A cross-cultural adaptation of a questionnaire on family satisfaction in the ICU can be feasible, valid, internally consistent, reliable, and sensitive.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: It has been shown that early central venous oxygen saturation (ScvO2)-guided optimization of hemodynamics can improve outcome in septic patients. The early ScvO2 profile of other patient groups is unknown. The aim of this study was to characterize unplanned admissions in a multidisciplinary intensive care unit (ICU) with respect to ScvO2 and outcome. METHODS: Ninety-eight consecutive unplanned admissions to a multidisciplinary ICU (median age 63 [range 19 to 83] years, median Simplified Acute Physiology Score [SAPS II] 43 [range 11 to 92]) with a clinical indication for a central venous catheter were included in the study. ScvO2 was assessed at ICU arrival and six hours later but was not used to guide treatment. Length of stay in ICU (LOSICU) and in hospital (LOShospital) and 28-day mortality were recorded. RESULTS: ScvO2 was 70% +/- 12% (mean +/- standard deviation) at admission and 71% +/- 10% six hours later (p = 0.484). Overall 28-day mortality was 18%, LOSICU was 3 (1 to 28) days, and LOShospital was 19 (1 to 28) days. Patients with an ScvO2 of less than 60% at admission had higher mortality than patients with an ScvO2 of more than 60% (29% versus 17%, p < 0.05). Changes in ScvO2 during the first six hours were not predictive of LOSICU, LOShospital, or mortality. CONCLUSION: Low ScvO2 in unplanned admissions and high SAPS II are associated with increased mortality. Standard ICU treatment increased ScvO2 in patients with a low admission ScvO2, but the increase was not associated with LOSICU or LOShospital.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. The purpose of this study was to determine the dose profile of the Cranex Tome radiography unit and compare it with that of the Scanora machine.Study design. The radiation dose delivered by the Cranex Tome radiography unit during the cross-sectional mode was determined. Single tooth gaps in regions 3 (16) and 30 (46) were simulated. Dosimetry was carried out with 2 phantoms, a head and neck phantom and a full-body phantom loaded with 142 thermoluminescent dosimeters (TLD) and 280 TLD, respectively; all locations corresponded to radiosensitive organs or tissues. The recorded local mean organ doses were compared with those measured in another study evaluating the Scanora machine.Results. Generally, dose values from the Cranex Tome radiography unit reached only 50% to 60% of the values measured for the Scanora machine. The effective dose was calculated as 0.061 mSv and 0.04 mSv for tooth regions 3 (16) and 30 (46), respectively. Corresponding values for the Scanora machine were 0.117 mSv and 0.084 mSv.Conclusion. Cross-sectional imaging in the molar region of the upper and the lower jaw can be performed with the Cranex Tome unit, which delivers only approximately half of the dose that the Scanora machine delivers.