996 resultados para kartat - Eurooppa - 1500-luku
Resumo:
The brown lacewings (Neuroptera, Hemerobiidae) of northwestern Turkey with new records, their spatio-temporal distribution and harbouring plants. The occurrence and spatio-temporal distribution of brown lacewing species (Neuroptera, Hemerobiidae) in Bursa province, northwestern Turkey, was investigated during 1999-2011. A total of 852 brown lacewing specimens of 20 species, including the genera of Hemerobius, Megalomus, Micromus, Sympherobius, and Wesmaelius were collected. Of these, 12 species were new records for northwestern Turkey while Sympherobius klapaleki is a new record for the Neuroptera fauna of Turkey. The most widespread species were Hemerobius handschini and Sympherobius pygmaeus with percent dominance values of 42.00 and 15.96%, respectively. Wesmaelius subnebulosus was the earliest emerging hemerobiid species and had the longest flight activity lasting from March to October. The species of southern origin characterized by the Mediterranean elements constituted 55% of the hemerobiid fauna and prevailed over the species of northern origin that belong to the Siberian centres. The total number of hemerobiid species reached a peak in July with captures of 15 species per month. There were 11, 13, 18 and 5 hemerobiid species occurring at altitudes between 1-500, 501-1000, 1001-1500 and 1500-2000 m, respectively. In addition, plant species harbouring hemerobiids are given for each species, and their association with the hemerobiid fauna is discussed.
Resumo:
OBJECTIVES: A new caval tree system was designed for realistic in vitro simulation. The objective of our study was to assess cannula performance for virtually wall-less versus standard percutaneous thin-walled venous cannulas in a setting of venous collapse in case of negative pressure. METHODS: For a collapsible caval model, a very flexible plastic material was selected, and a model with nine afferent veins was designed according to the anatomy of the vena cava. A flow bench was built including a lower reservoir holding the caval tree, built by taking into account the main afferent vessels and their flow provided by a reservoir 6 cm above. A cannula was inserted in this caval tree and connected to a centrifugal pump that, in turn, was connected to a reservoir positioned 83 cm above the second lower reservoir (after-load = 60 mmHg). Using the same pre-load, the simulated venous drainage for cardiopulmonary bypass was realized using a 24 F wall-less cannula (Smartcanula) and 25 F percutaneous cannula (Biomedicus), and stepwise increased augmentation (1500 RPM, 2000 and 2500 RPM) of venous drainage. RESULTS: For the thin wall and the wall-less cannulas, 36 pairs of flow and pressure measurements were realized for three different RPM values. The mean Q-values at 1500, 2000 and 2500 RPM were: 3.98 ± 0.01, 6.27 ± 0.02 and 9.81 ± 0.02 l/min for the wall-less cannula (P <0.0001), versus 2.74 ± 0.02, 3.06 ± 0.05, 6.78 ± 0.02 l/min for the thin-wall cannula (P <0.0001). The corresponding inlet pressure values were: -8.88 ± 0.01, -23.69 ± 0.81 and -70.22 ± 0.18 mmHg for the wall-less cannula (P <0.0001), versus -36.69 ± 1.88, -80.85 ± 1.71 and -101.83 ± 0.45 mmHg for the thin-wall cannula (P <0.0001). The thin-wall cannula showed mean Q-values 37% less and mean P values 26% more when compared with the wall-less cannula (P <0.0001). CONCLUSIONS: Our in vitro water test was able to mimic a negative pressure situation, where the wall-less cannula design performs better compared with the traditional thin-wall cannula.
Resumo:
Summary: "White" military architecture in Finland, 1926-1939
Resumo:
Summary: Middle-of-the-roader : General Aarne Sihvo (1889-1963) and the interaction between the Finnish armed forces and democracy