901 resultados para high performance polymers


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Five selective serotonin reuptake inhibitors (SSRIs) have been introduced recently: citalopram, fluoxetine, fluvoxamine, paroxetine and sertraline. Although no therapeutic window has been defined for SSRIs, in contrast to tricyclic antidepressants, analytical methods for therapeutic drug monitoring of SSRIs are useful in several instances. SSRIs differ widely in their chemical structure and in their metabolism. The fact that some of them have N-demethylated metabolites, which are also SSRIs, requires that methods be available which allow therapeutic drug monitoring of the parent compounds and of these active metabolites. most procedures are based on prepurification of the SSRIs by liquid-liquid extraction before they are submitted to separation by chromatographic procedures (high-performance liquid chromatography, gas chromatography, thin layer chromatography) and detection by various detectors (UV, fluorescence, electrochemical detector, nitrogen-phosphorus detector, mass spectrometry). This literature review shows that most methods allow quantitative determination of SSRIs in plasma, in the lower ng/ml range, and that they are, therefore, suitable for therapeutic drug monitoring purposes of this category of drugs.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Usually, the differentiation of inks on questioned documents is carried out by optical methods and thin layer chromatography (TLC). Therefore, spectrometric methods were also proposed in forensic literature for the analysis of dyes. Between these techniques, laser desorption/ionization mass spectrometry (LDI-MS) has demonstrated a great versatility thanks to its sensitivity to blue ballpoint ink dyes and minimal sample destruction. Previous researches concentrated mostly on the LDI-MS positive mode and have shown that this analytical tool offers higher discrimination power than high performance TLC (HPTLC) for the differentiation of blue ballpoint inks. Although LDI-MS negative mode has already been applied in numerous forensic domains like the studies of works of art, automotive paints or rollerball pens, its potential for the discrimination of ballpoint pens was never studied before. The aim of the present paper is therefore to evaluate its potential for the discrimination of blue ballpoint inks. After optimization of the method, ink entries from 33 blue ballpoint pens were analyzed directly on paper in both positive and negative modes by LDI-MS. Several cationic and anionic ink components were identified in inks; therefore, pens were classified and compared according to their formulations. Results show that additional information provided by anionic dyes and pigments significantly increases the discrimination power of positive mode. In fact, it was demonstrated that classifications obtained by the two modes were, to some extent, complementary (i.e., inks with specific cationic dyes not necessarily contained the same anionic components).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

De tout temps, hommes et femmes ont cherché par tous les moyens à développer, préserver ou recouvrer leurs propres capacités sexuelles mais également à stimuler le désir du partenaire. L?utilisation d?aphrodisiaques naturels a été l?un des recours les plus répandus. De nos jours, la commercialisation de nouvelles "love drugs" de synthèse, e.g. Viagra®, Cialis®, Levitra®, a remis au goût du jour les aphrodisiaques classiques et à relancer la recherche sur des molécules nouvelles. La pratique croissante de l?automédication, le matraquage publicitaire sur les aphrodisiaques naturels, la prolifération sur le marché de compléments alimentaires non contrôlés et l?absence de véritable législation accroissent les risques qui pèsent sur la santé publique. Dans le but d?évaluer les risques potentiels sur le consommateur de produits aphrodisiaques commercialisés, le développement et la validation d?une méthode rapide d?analyse qualitative et quantitative de la yohimbine dans ces préparations du marché sont exposés dans la première partie de ce travail. La yohimbine est un antagoniste ?2-adrénocepteur du système nerveux central et périphérique, elle est employée depuis plus d?un siècle dans le traitement des dysfonctionnements érectiles. Cette méthode analytique utilise la chromatographie liquide couplée à l?ultraviolet et à la spectrométrie de masse (LC-UV-MS) et au total, vingt préparations aphrodisiaques ont été étudiées. La dose journalière de yohimbine mesurée s?est révélée très variable selon les produits puisqu?elle varie de 1.32 à 23.16 mg. La seconde partie de ce travail concerne l?étude phytochimique et pharmacologique d?Erythroxylum vacciniifolium Mart. (Erythroxylaceae), une plante, appelée localement catuaba, utilisée dans la médecine traditionnelle brésilienne comme tonique et aphrodisiaque. Dans un premier temps, l?extrait alcaloïdique a été analysé par chromatographie liquide haute performance (HPLC) couplée soit à un détecteur UV à barrette d?iode (LC-UV-DAD), soit à un spectromètre de masse (LC-MS), ou soit à un spectromètre de résonance magnétique nucléaire (LC-RMN). L?interprétation de ces données spectrales enregistrées en ligne a permis d?obtenir des informations structurales et d?identifier partiellement près de 24 alcaloïdes appartenant à la classe des tropanes et potentiellement originaux. Par des méthodes classiques de chromatographie liquide sur l?extrait alcaloïdique de la plante, dix sept tropanes nouveaux ont ensuite été isolés dont les catuabines et leurs dérivés, et les vaccinines. Tous ces composés sont des tropane-diols ou triols estérifiés par au moins un groupe acide 1-méthyl-1H-pyrrole-2-carboxylique. Un de ces composés a été identifié comme un tropane N-oxyde. Toutes les structures ont été déterminées par spectrométrie de masse haute résolution et spectroscopie RMN multi-dimensionnelle. Parmi les nombreux tests biologiques réalisés sur ces tropanes, seuls les tests de cytotoxicité se sont révélés faiblement positifs pour certains de ces composés.<br/><br/>Throughout the ages, men and women have incessantly pursued every means to increase, preserve or recapture their sexual capacity, or to stimulate the sexual desire of selected individuals. One of the most recurrent methods has been the use of natural aphrodisiacs. Nowadays, the commercialization of new synthetic "love drugs", e.g. Viagra®, Cialis® and Levitra®, has fascinated the public interest and has led to a reassessment of classical aphrodisiacs and to the search for new ones. The practice of self-medication by an increasing number of patients, the incessant aggressive advertising of these herbal aphrodisiacs, the invasion of the medicinal market with uncontrolled dietary supplements and the absence of real directives amplifies the potential health hazards to the community. In order to evaluate the possible risks of commercialized aphrodisiac products on consumer health, the development and validation of a rapid qualitative and quantitative method for the analysis of yohimbine in these products, is reported in the first part of the present work. Yohimbine, a pharmacologically well-characterized ?2-adrenoceptor antagonist with activity in the central and peripheral nervous system, has been used for over a century in the treatment of erectile dysfunction. The analytical method is based on liquid chromatography coupled with ultraviolet and mass spectrometry (LC-UV-MS) and in total, 20 commercially-available aphrodisiac preparations were analyzed. The amount of yohimbine measured and expressed as the maximal dose per day suggested on product labels ranged from 1.32 to 23.16 mg. The second part of this work involved the phytochemical and pharmacological investigation of Erythroxylum vacciniifolium Mart. (Erythroxylaceae), a plant used in Brazilian traditional medicine as an aphrodisiac and tonic, and locally known as catuaba. With the aim of obtaining preliminary structure information on-line, the alkaloid extract was analyzed by high performance liquid chromatography (HPLC) coupled to diode array UV detection (LC-UVDAD), to mass spectrometry (LC-MS) and to nuclear magnetic resonance spectroscopy (LCNMR). Interpretation of on-line spectroscopic data led to structure elucidation and partial identification of 24 potentially original alkaloids bearing the same tropane skeleton. Seventeen new tropane alkaloids were then isolated from the alkaloid extract of the plant, including catuabines D to I, their derivatives and vaccinines A and B. All compounds were elucidated as tropane-diol or -triol alkaloids esterified by at least one 1-methyl-1H-pyrrole-2-carboxylic acid. One of the isolated compounds was identified as a tropane alkaloid N-oxide. Their structures were determined by high resolution mass spectrometry and multi-dimensional NMR spectroscopy. Among the numerous bioassays undertaken, only the cytotoxicity tests exhibited a weak positive activity of certain compounds.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Le but essentiel de notre travail a été d?étudier la capacité du foie, premier organe de métabolisation des xénobiotiques, à dégrader la cocaïne en présence d?éthanol, à l?aide de deux modèles expérimentaux, à savoir un modèle cellulaire (les hépatocytes de rat en suspension) et un modèle acellulaire (modèle reconstitué in vitro à partir d?enzymes purifiées de foie humain). La première partie a pour objectifs de rechercher les voies de métabolisation de la cocaïne qui sont inhibées et / ou stimulées en présence d?éthanol, sur hépatocytes isolés de rat. Dans ce but, une méthode originale permettant de séparer et de quantifier simultanément la cocaïne, le cocaéthylène et huit de leurs métabolites respectifs a été développée par Chromatographie Phase Gazeuse couplée à la Spectrométrie de Masse (CPG / SM). Nos résultats préliminaires indiquent que l?éthanol aux trois concentrations testées (20, 40 et 80 mM) n?a aucun effet sur la cinétique de métabolisation de la cocaïne. Notre étude confirme que l?addition d?éthanol à des cellules hépatiques de rat en suspension supplémentées en cocaïne résulte en la formation précoce de benzoylecgonine et de cocaéthylène. L?apparition retardée d?ecgonine méthyl ester démontre l?activation d?une deuxième voie de détoxification. La production tardive d?ecgonine indique une dégradation de la benzoylecgonine et de l?ecgonine méthyl ester. De plus, la voie d?oxydation intervenant dans l?induction du stress oxydant en produisant de la norcocaïne est tardivement stimulée. Enfin, notre étude montre une métabolisation complète de la concentration initiale en éthanol par les hépatocytes de rat en suspension. La deuxième partie a pour but de déterminer s?il existe d?autres enzymes que les carboxylesterases formes 1 et 2 humaines ayant une capacité à métaboliser la cocaïne seule ou associée à de l?éthanol. Pour ce faire, une méthode de micropurification par chromatographie liquide (Smart System®) a été mise au point. Dans le cadre de nos dosages in situ de la cocaïne, du cocaéthylène, de la benzoylecgonine, de l?acide benzoïque et de la lidocaïne, une technique par Chromatographie Liquide Haute Performance couplée à une Détection par Barrette de Diode (CLHP / DBD) et une méthode de dosage de l?éthanol par Chromatographie Phase Gazeuse couplée à une Détection par Ionisation de Flamme équipée d?un injecteur à espace de tête (espace de tête CPG / DIF) ont été développées. La procédure de purification nous a permis de suspecter la présence d?autres enzymes que les carboxylesterases formes 1 et 2 de foie humain impliquées dans le métabolisme de la cocaïne et déjà isolées. A partir d?un modèle enzymatique reconstitué in vitro, nos résultats préliminaires indiquent que d?autres esterases que les formes 1 et 2 de foie humain sont impliquées dans l?élimination de la cocaïne, produisant benzoylecgonine et ecgonine méthyl ester. De plus, nous avons montré que les sensibilités de ces enzymes à l?éthanol sont variables.<br/><br/>The main purpose of our work was to study the ability of the liver, as the first organ to metabolise xenobiotic substances, to degrade cocaine in the presence of ethanol. In order to do this, we used two experimental models, namely a cellular model (rat liver cells in suspension) and an a-cellular model (model reconstructed in vitro from purified human liver enzymes). The purpose of the first part of our study was to look for cocaine metabolising processes which were inhibited and / or stimulated by the presence of ethanol, in isolated rat liver cells. With this aim in mind, an original method for simultaneously separating and quantifying cocaine, cocaethylene and eight of their respective metabolites was developed by Vapour Phase Chromatography coupled with Mass Spectrometry (VPC / MS). Our preliminary results point out that ethanol at three tested concentrations (20, 40 et 80 mM) have no effect on the kinetic of metabolisation of cocaine. Our study confirms that the addition of alcohol to rat liver cells in suspension, supplemented with cocaine, results in the premature formation of ecgonine benzoyl ester and cocaethylene. The delayed appearance of ecgonine methyl ester shows that a second detoxification process is activated. The delayed production of ecgonine indicates a degradation of the ecgonine benzoyl ester and the ecgonine methyl ester. Moreover, the oxidising process which occurs during the induction of the oxidising stress, producing norcocaine, is stimulated at a late stage. Finally, our study shows the complete metabolisation of the initial alcohol concentration by the rat liver cells in suspension. The second part consisted in determining if enzymes other than human carboxylesterases 1 and 2, able to metabolise cocaine on its own or with alcohol, existed. To do this, a micropurification method us ing liquid phase chromatography (Smart System®) was developed. A technique based on High Performance Liquid Chromatography coupled with a Diode Array Detection (HPLC / DAD) in the in situ proportioning of cocaine, cocaethylene, ecgonine benzoyl ester, benzoic acid and lidocaine, and a method for proportioning alcohol by quantifying the head space using Vapour Phase Chromatography coupled with a Flame Ionisation Detection (head space VPC / FID) were used. The purification procedure pointed to the presence of enzymes other than the human liver carboxylesterases, forms 1 and 2, involved in the metabolism of cocaine and already isolated. The preliminary results drawn from an enzymatic model reconstructed in vitro indicate that human liver carboxylesterases, other than forms 1 and 2, are involved in the elimination of cocaine, producing ecgonine benzoyl ester and ecgonine methyl ester. Moreover, we have shown that the sensitivity of these enzymes to alcohol is variable.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Numerical weather prediction and climate simulation have been among the computationally most demanding applications of high performance computing eversince they were started in the 1950's. Since the 1980's, the most powerful computers have featured an ever larger number of processors. By the early 2000's, this number is often several thousand. An operational weather model must use all these processors in a highly coordinated fashion. The critical resource in running such models is not computation, but the amount of necessary communication between the processors. The communication capacity of parallel computers often fallsfar short of their computational power. The articles in this thesis cover fourteen years of research into how to harness thousands of processors on a single weather forecast or climate simulation, so that the application can benefit as much as possible from the power of parallel high performance computers. The resultsattained in these articles have already been widely applied, so that currently most of the organizations that carry out global weather forecasting or climate simulation anywhere in the world use methods introduced in them. Some further studies extend parallelization opportunities into other parts of the weather forecasting environment, in particular to data assimilation of satellite observations.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pulsewidth-modulated (PWM) rectifier technology is increasingly used in industrial applications like variable-speed motor drives, since it offers several desired features such as sinusoidal input currents, controllable power factor, bidirectional power flow and high quality DC output voltage. To achieve these features,however, an effective control system with fast and accurate current and DC voltage responses is required. From various control strategies proposed to meet these control objectives, in most cases the commonly known principle of the synchronous-frame current vector control along with some space-vector PWM scheme have been applied. Recently, however, new control approaches analogous to the well-established direct torque control (DTC) method for electrical machines have also emerged to implement a high-performance PWM rectifier. In this thesis the concepts of classical synchronous-frame current control and DTC-based PWM rectifier control are combined and a new converter-flux-based current control (CFCC) scheme is introduced. To achieve sufficient dynamic performance and to ensure a stable operation, the proposed control system is thoroughly analysed and simple rules for the controller design are suggested. Special attention is paid to the estimationof the converter flux, which is the key element of converter-flux-based control. Discrete-time implementation is also discussed. Line-voltage-sensorless reactive reactive power control methods for the L- and LCL-type line filters are presented. For the L-filter an open-loop control law for the d-axis current referenceis proposed. In the case of the LCL-filter the combined open-loop control and feedback control is proposed. The influence of the erroneous filter parameter estimates on the accuracy of the developed control schemes is also discussed. A newzero vector selection rule for suppressing the zero-sequence current in parallel-connected PWM rectifiers is proposed. With this method a truly standalone and independent control of the converter units is allowed and traditional transformer isolation and synchronised-control-based solutions are avoided. The implementation requires only one additional current sensor. The proposed schemes are evaluated by the simulations and laboratory experiments. A satisfactory performance and good agreement between the theory and practice are demonstrated.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

During the latest few years the need for new motor types has grown, since both high efficiency and an accurate dynamic performance are demanded in industrial applications. For this reason, new effective control systems such as direct torque control (DTC) have been developed. Permanent magnet synchronous motors (PMSM) are well suitable for new adjustable speed AC inverter drives, because their efficiency and power factor are not depending on the pole pair number and speed to the same extent as it is the case in induction motors. Therefore, an induction motor (IM) with a mechanical gearbox can often be replaced with a direct PM motor drive. Space as well as costs will be saved, because the efficiency increases and the cost of maintenance decreases as well. This thesis deals with design criterion, analytical calculation and analysis of the permanent magnet synchronous motor for both sinusoidal air-gap flux density and rectangular air-gapflux density. It is examined how the air-gap flux, flux densities, inductances and torque can be estimated analytically for salient pole and non-salient pole motors. It has been sought by means of analytical calculations for the ultimate construction for machines rotating at relative low 300 rpm to 600 rpm speeds, which are suitable speeds e.g. in Pulp&Paper industry. The calculations are verified by using Finite Element calculations and by measuring of prototype motor. The prototype motor is a 45 kW, 600 rpm PMSM with buried V-magnets, which is a very appropriate construction for high torque motors with a high performance. With the purposebuilt prototype machine it is possible not only to verify the analytical calculations but also to show whether the 600 rpm PMSM can replace the 1500 rpm IM with a gear. It can also be tested if the outer dimensions of the PMSM may be the same as for the IM and if the PMSM in this case can produce a 2.5 fold torque, in consequence of which it may be possible to achieve the same power. The thesis also considers the question how to design a permanent magnet synchronous motor for relatively low speed applications that require a high motor torqueand efficiency as well as bearable costs of permanent magnet materials. It is shown how a selection of different parameters affects the motor properties. Key words: Permanent magnet synchronous motor, PMSM, surface magnets, buried magnets

Relevância:

80.00% 80.00%

Publicador:

Resumo:

High dynamic performance of an electric motor is a fundamental prerequisite in motion control applications, also known as servo drives. Recent developments in the field of microprocessors and power electronics have enabled faster and faster movements with an electric motor. In such a dynamically demanding application, the dimensioning of the motor differs substantially from the industrial motor design, where feasible characteristics of the motor are for example high efficiency, a high power factor, and a low price. In motion control instead, such characteristics as high overloading capability, high-speed operation, high torque density and low inertia are required. The thesis investigates how the dimensioning of a high-performance servomotor differs from the dimensioning of industrial motors. The two most common servomotor types are examined; an induction motor and apermanent magnet synchronous motor. The suitability of these two motor types indynamically demanding servo applications is assessed, and the design aspects that optimize the servo characteristics of the motors are analyzed. Operating characteristics of a high performance motor are studied, and some methods for improvements are suggested. The main focus is on the induction machine, which is frequently compared to the permanent magnet synchronous motor. A 4 kW prototype induction motor was designed and manufactured for the verification of the simulation results in the laboratory conditions. Also a dynamic simulation model for estimating the thermal behaviour of the induction motor in servo applications was constructed. The accuracy of the model was improved by coupling it with the electromagnetic motor model in order to take into account the variations in the motor electromagnetic characteristics due to the temperature rise.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A partir de un extracto metanólico de semillas de Melia azedarach se han aislado los compuestos responsables de su actividad biológica como agentes inhibidores de la alimentación y reguladores del desarrollo sobre Sesamia nonagrioides. Las pruebas biológicas de actividad se han realizado incorporando cada fracción a la dieta, hojas de maíz o dieta sintética, de larvas de 2°estadio del insecto. La técnica de cromatografía líquida de alta resolución a escala semipreparativa, utilizando un cartucho de fase reversa, ha permitido separar dos componentes con cantidad y pureza suficientes para poder ser analizados con posterioridad mediante técnicas espectroscópicas.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The need for high performance, high precision, and energy saving in rotating machinery demands an alternative solution to traditional bearings. Because of the contactless operation principle, the rotating machines employing active magnetic bearings (AMBs) provide many advantages over the traditional ones. The advantages such as contamination-free operation, low maintenance costs, high rotational speeds, low parasitic losses, programmable stiffness and damping, and vibration insulation come at expense of high cost, and complex technical solution. All these properties make the use of AMBs appropriate primarily for specific and highly demanding applications. High performance and high precision control requires model-based control methods and accurate models of the flexible rotor. In turn, complex models lead to high-order controllers and feature considerable computational burden. Fortunately, in the last few years the advancements in signal processing devices provide new perspective on the real-time control of AMBs. The design and the real-time digital implementation of the high-order LQ controllers, which focus on fast execution times, are the subjects of this work. In particular, the control design and implementation in the field programmable gate array (FPGA) circuits are investigated. The optimal design is guided by the physical constraints of the system for selecting the optimal weighting matrices. The plant model is complemented by augmenting appropriate disturbance models. The compensation of the force-field nonlinearities is proposed for decreasing the uncertainty of the actuator. A disturbance-observer-based unbalance compensation for canceling the magnetic force vibrations or vibrations in the measured positions is presented. The theoretical studies are verified by the practical experiments utilizing a custom-built laboratory test rig. The test rig uses a prototyping control platform developed in the scope of this work. To sum up, the work makes a step in the direction of an embedded single-chip FPGA-based controller of AMBs.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fytoestrogeenit ovat kasvimateriaalista peräisin olevia yhdisteitä, joilla on ihmisen estrogeeni-hormonin kaltaista aktiivisuutta. Fytoestrogeenit voidaan jakaa kolmeen pääryhmään, joista yksi merkittävä ryhmä on lignaanit. Lignaaneilla on todettu olevan antioxidatiivisia, antiviraalisia ja antibakteriaalisia ominaisuuksia. Niillä on todettu olevan myös positiivisia vaikutuksia hormoniperäisten syöpien ehkäisyssä. Näiden ominaisuuksien vuoksi lignaaneja pyritään hyödyntämään esimerkiksi aktiivisina ainesosina funktionaalisissa elintarvikkeissa. Tässä työssä tutkittiin lignaanin, hydroksimatairesinolin (HMRlignanTM) kemiallisia ominaisuuksia ja soveltuvuutta eri ruoka-aineisiin. Työn tarkoituksena oli selvittää ruoka-aineisiin lisätyn hydroksimatairesinolin kemiallista pysyvyyttä erilaisissa säilytys- ja prosessointioloissa sekä tutkia lignaanin liukoisuutta erilaisiin liuottimiin. Hydroksimatairesinolin analysoimiseksi ruoka-aineista käytettiin korkean erotuskyvyn omaavaa nestekromatografista menetelmää. Menetelmä validoitiin ennen varsinaista analysointia ICH-ohjeiston mukaisesti. Validoinnissa tutkittiin kromatografiamenetelmän spesifisyys, lineaarisuus, tarkkuus, oikeellisuus sekä detektointi- ja määritysrajat tutkittavalle lignaanille. Käytetty menetelmä soveltui hyvin lignaanin analysoimiseen ruoka-aineista. Hydroksimatairesinolin vesiliukoisuuden todettiin olevan noin 1 mg/ml. Tutkimukset osoittivat hydroksimatairesinolin olevan stabiili alle 50ºC:en lämpötiloissa. Korkeammissa lämpötiloissa hydroksimatairesinoli oli stabiili jauhemuodossa lisättynä.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pereskia aculeata Mill. (Ora-pro-nóbis) is a native cactaceae from tropical America, whose leaves have high protein content. In Brazil it is found in all territorial extension between the states of Bahia and Rio Grande do Sul. Most studies have focused on chemical characterization of the leaves of this specie. The objective was to assess the carotenoids profile and the total polyphenols present in the fruits of P. aculeate. Carotenoids were determined by HPLC-PAD (high performance liquid chromatography - photodiode array detector), total polyphenols were determined by Folin-Ciocalteu and vanillin methods. Trans-β-carotene was the main carotenoid, followed by α-carotene, lutein and other minor carotenoids. It was found 64.9 ± 1.1 mg.100g-1 of gallic acid equivalent, 14.8 ± 0.2 mg.100g-1 of catechin equivalent. Carotenoid identification of P. aculeate fruits are presented here by the first time and indicate that these fruits can be researched as source of bioactive substances, especially antioxidant and provitamin A carotenoids.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Diplomityön tavoitteena oli selvittää elintarvikepakkauksiin soveltuvan graafisen kartongin potentiaalinen hajun aiheuttaja. Lisäksi tavoitteena oli vähentää päällystetyn tasakoosteisen (SBS) kolmikerroskartongin hajutasoa keskittyen päällystyspastakomponentteihin sekä massaosaston jälkeen annosteltaviin kemikaaleihin. Kirjallisuusosassa tarkasteltiin eri kartonkilajeja, päällystyspastoja ja sen sisältämiä komponentteja, pääpainon ollessa kuitenkin kartongin hajuominaisuuksiin vaikuttavien tekijöiden selvittämisessä. Lisäksi luotiin katsaus kartonkien aistinvaraisiin ja instrumentaalisiin määritysmenetelmiin. Instrumentaalisista määritysmenetelmistä käsiteltiin headspace –kaasukromatografia (HSGC) sekä korkeanerotuskyvyn nestekromatografia yhdistettynä massaspektrometriin (HPLC/MS). Kokeellisen osan alussa kartoitettiin päällystyskemikaalien sekä liima- ja retentioaineiden haihtuvat yhdisteet HSGC- ja HPLC/MS –tekniikoiden avulla. Kaasukromatografisesti analysoidut kokonaishaihtuvien tasot eivät poikenneet normaaleista tasoista, joten jouduttiin siirtymään HPLC/MS –menetelmään. HPLC/MS –tekniikalla on päästy tutkimaan herkästi haihtuvien typpiyhdisteiden amiinipitoisuuksia. Kemikaalimittausten perusteella vaihdettiin potentiaaliset hajua aiheuttavat kemikaalit, kovete ja synteettinen paksuntaja, markkinoilla oleviin vaihtoehtoisiin kemikaaleihin ja suoritettiin pilot -koeajo sekä tehdasmittakaavaiset koeajot. Työssä perehdyttiin myös varastoinnin aiheuttamiin vaikutuksiin eri kartonkilaatujen aistinvaraisissa ominaisuuksissa. Päällystyspastan kemikaaleista suuren hajukuorman aiheuttavat kovete, dispergointiaine, päällystyspigmentit ja lateksit sekä synteettinen paksuntaja. Kovetteen annostelumäärä päällystyspastoihin on alhainen, mutta sen sisältämä ammoniakkipitoisuus on kuitenkin huomattavan suuri. Kovete ohjaakin lopputuotteen ammoniakkipitoisuutta. Merkittävän metyyliamiinikuorman sisältää dispergointiaine. Sen vaikutus lopputuotteeseen voidaan olettaa vähäiseksi johtuen kemikaalin pienestä määrästä pastassa. Päällystyspigmenttien ja lateksien korkea metyyliamiinikuorma voi puolestaan aiheuttaa lopputuotteeseen huomattavan hajukuorman johtuen niiden suurista annostelumääristä. Eri synteettisille paksuntajille tehtyjen tutkimusten mukaan niiden hajukuormat olivat hyvin samankaltaisia ja vaikutus lopputuotteen kokonaishajutasoon jäi pieneksi. Aistinvaraisesti tarkasteltuna eri kartonkilaaduille saadaan eri hajutasoja. Elintarvikepakkauksiin soveltuvan graafisen kartongin hajutasot olivat korkeita muihin kartonkilaatuihin nähden niin tuoreena kuin varastoinnin jälkeen. Erityisesti tuoreen kartonkinäytteen metyyliamiinipitoisuus ylitti hajukynnyksen. Käytetty lateksi, kovete ja synteettinen paksuntaja näyttävät muodostavan niin tiiviin hajua koteloivan päällystekerroksen kartongin pinnalle, että hajua vapautuu pitkällä aikavälillä. Myös varastointi tiiviinä pakkauksena estää amiinien haihtumisen. Tutkimusten mukaan ammoniakkivapaalla PZC –kovetteella saadaan alennettua graafisen kartongin ammoniakkikuormaa huomattavasti. Tämä on vaikuttamassa myös lopputuotteen hajutasoon, jota on mahdollisuus alentaa käyttämällä ammoniakkivapaata kovetetta.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A straightforward methodology for the synthesis of conjugates between a cytotoxic organometallic ruthenium(II) complex and amino- and guanidinoglycosides, as potential RNA-targeted anticancer compounds, is described. Under microwave irradiation, the imidazole ligand incorporated on the aminoglycoside moiety (neamine or neomycin) was found to replace one triphenylphosphine ligand from the ruthenium precursor [(η6-p-cym)RuCl(PPh3)2]+, allowing the assembly of the target conjugates. The guanidinylated analogue was easily prepared from the neomycin-ruthenium conjugate by reaction with N,N′-di-Boc-N″-triflylguanidine, a powerful guanidinylating reagent that was compatible with the integrity of the metal complex. All conjugates were purified by semipreparative high-performance liquid chromatography (HPLC) and characterized by electrospray ionization (ESI) and matrix-assisted laser desorption-ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) and NMR spectroscopy. The cytotoxicity of the compounds was tested in MCF-7 (breast) and DU-145 (prostate) human cancer cells, as well as in the normal HEK293 (Human Embryonic Kidney) cell line, revealing a dependence on the nature of the glycoside moiety and the type of cell (cancer or healthy). Indeed, the neomycin-ruthenium conjugate (2) displayed moderate antiproliferative activity in both cancer cell lines (IC50 ≈ 80 μM), whereas the neamine conjugate (4) was inactive (IC50 ≈ 200 μM). However, the guanidinylated analogue of the neomycin-ruthenium conjugate (3) required much lower concentrations than the parent conjugate for equal effect (IC50 = 7.17 μM in DU-145 and IC50 = 11.33 μM in MCF-7). Although the same ranking in antiproliferative activity was found in the nontumorigenic cell line (3 2 > 4), IC50 values indicate that aminoglycoside-containing conjugates are about 2-fold more cytotoxic in normal cells (e.g., IC50 = 49.4 μM for 2) than in cancer cells, whereas an opposite tendency was found with the guanidinylated conjugate, since its cytotoxicity in the normal cell line (IC50 = 12.75 μM for 3) was similar or even lower than that found in MCF-7 and DU-145 cancer cell lines, respectively. Cell uptake studies performed by ICP-MS with conjugates 2 and 3 revealed that guanidinylation of the neomycin moiety had a positive effect on accumulation (about 3-fold higher in DU-145 and 4-fold higher in HEK293), which correlates well with the higher antiproliferative activity of 3. Interestingly, despite the slightly higher accumulation in the normal cell than in the cancer cell line (about 1.4-fold), guanidinoneomycin-ruthenium conjugate (3) was more cytotoxic to cancer cells (about 1.8-fold), whereas the opposite tendency applied for neomycin-ruthenium conjugate (2). Such differences in cytotoxic activity and cellular accumulation between cancer and normal cells open the way to the creation of more selective, less toxic anticancer metallodrugs by conjugating cytotoxic metal-based complexes such as ruthenium(II) arene derivatives to guanidinoglycosides.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE: Systolic blood pressure (BP) has been associated with urinary caffeine and its metabolites such as paraxanthine and theophylline. Caffeine and caffeine metabolites could influence arterial pulse pressure (PP) via sympathomimetic effects, smooth muscle relaxation, and phosphodiesterase inhibition. The purpose of this analysis was to explore the association of ambulatory PP with urinary caffeine and its related metabolites in a large population-based sample. DESIGN AND METHOD: Families were randomly selected from the general population of three Swiss cities (2009-2013). Ambulatory BP monitoring was conducted using validated Diasys Integra devices. PP was defined as the difference between the systolic and diastolic ambulatory BP. Urinary caffeine, paraxanthine, theophylline, and theobromine excretions were measured in 24 h urine using ultra-high performance liquid chromatography tandem mass spectrometry. Urinary excretions were log-transformed to satisfy regression assumptions. We used linear mixed models to explore the associations of urinary caffeine and caffeine metabolite excretions with 24-hour, day- and night-time PP while adjusting for major confounders. RESULTS: The 836 participants (48.9% men) included in this analysis had mean (±SD) age of 47.8 (±17.5), and mean 24-hour systolic and diastolic BP of 120.1 mmHg (±13.9) and 78.0 (±8.6). Except theobromine, log transformed urinary caffeine and caffeine metabolite excretions were associated negatively with 24-hour, daytime and night-time ambulatory PP. 24-hour, daytime, and night-time ambulatory PP decreased by -0.804 mmHg (SE, 0.209), -0.749 (0.215), and -0.968 (0.243) (all P values <0.005), for each doubling excretion of caffeine. Strong negative associations with night-time ambulatory PP were observed for paraxanthine and theophylline.(Figure is included in full-text article.) CONCLUSIONS: : The negative associations of PP with caffeine, paraxanthine, and theophylline excretions suggest that caffeine and its metabolites do lower BP, possibly by modifying arterial stiffness.