987 resultados para free-choice profile


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Use of cisplatin can induce type I hypersensitivity reactions that may also be linked to the quality of the drug utilized. We observed cases of hypersensitivity that appeared to be associated with the brand of cisplatin used. The aim of this study was to compare two different brands of cisplatin in relation to type I hypersensitivity reactions. Brand A was used in a tertiary care teaching hospital until 2012, and use of brand B started from January 2013, when the first hypersensitivity cases were observed. Patients were categorized based on symptom. Cisplatin of both brands was analysed by high-performance liquid chromatography (HPLC) and high-resolution electrospray ionization mass spectrometry (ESI-(+)-MS) and characterized according to US Pharmacopeia. There were no cases of hypersensitivity associated with the use of cisplatin brand A, whereas four of 127 outpatients that used cisplatin brand B were affected. The two brands were in accordance with the US Pharmacopeia parameters, and there was no significant difference in the total platinum levels between the two brands when analysed by HPLC. However, high-resolution ESI-(+)-MS analyses show that brand B contains approximately 2.7 times more hydrolysed cisplatin than brand A. The increase in the hydrolysed form of cisplatin found in brand B may be the cause of the hypersensitivity reaction observed in a subset of patients. We present the first study of the quality of drugs by high-resolution ESI-(+)-MS. Drug regulatory agencies and manufacturers should consider including measurement of hydrolysed cisplatin as a quality criterion for cisplatin formulations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The difficulty in adapting European dairy cows breeds in Brazil affect considerably the milk production sector. Brazilian climatic conditions are not totally favorable and the development of new tecnologies is needed for the animals express their genetic potential, as well as their best feed conversion. An economical analysis of the applied investment in the free-stall climatization equipment in dairy housing, for estimating studies related to profit, possibility of return investment as well as time for this return is necessary. The objective of this research was to evaluate the influence of climatization investment in the milk production process and analyze the economical aspect of this investment. There were used 470 high productive dairy cows with genetic and morphologic homogeneous characteristics, and analyzed in two similar periods. Investment calculations were done using Excell®. The results were satisfactory and the invested capital was proved to return to the producer in a short term, 57 days.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In 2004, Costa-Santos and cols. reported 24 patients from 19 Brazilian families with 17α-hydroxylase deficiency and showed that p.W406R and p.R362C corresponded to 50% and 32% of CYP17A1 mutant alleles, respectively. The present report describes clinical and molecular data of six patients from three inbred Brazilian families with 17α-hydroxlyse deficiency. All patients had hypogonadism, amenorrhea and hypertension at diagnosis. Two sisters were found to be 46,XY with both gonads palpable in the inguinal region. All patients presented hypergonadotrophic hypogonadism, with high levels of ACTH (> 104 ng/mL), suppressed plasmatic renin activity, low levels of potassium (< 2.8 mEq/L) and elevated progesterone levels (> 4.4 ng/mL). Three of them, including two sisters, were homozygous for p.W406R mutation and the other three (two sisters and one cousin) were homozygous for p.R362C. The finding of p.W406R and p.R362C in the CYP17A1 gene here reported in additional families, confirms them as the most frequent mutations causing complete combined 17α-hydroxylase/17,20-lyase deficiency in Brazilian patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study aimed to compare the fluoride (F-) release pattern of a nanofilled resin-modified glass ionomer cement (GIC) (Ketac N100 - KN) with available GICs used in dental practice (resin-modified GIC - Vitremer - V; conventional GIC - Ketac Molar - KM) and a nanofilled resin composite (Filtek Supreme - RC). Discs of each material (n=6) were placed into 4 mL of deionized water in sealed polyethylene vials and shaken, for 15 days. F- release (μg F-/cm²) was measured each day using a fluoride-ion specific electrode. Cumulative F- release means were statistically analyzed by linear regression analysis. In order to analyze the differences among materials and the influence of time in the daily F- release, 2-way ANOVA test was performed (α=0.05). The linear fits between the cumulative F- release profiles of RC and KM and time were weak. KN and V presented a strong relationship between cumulative F- release and time. There were significant differences between the daily F- release overtime up to the third day only for GICs materials. The daily F- release means for RC were similar overtime. The results indicate that the F- release profile of the nanofilled resin-modified GIC is comparable to the resin-modified GIC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Advances in diagnostic research are moving towards methods whereby the periodontal risk can be identified and quantified by objective measures using biomarkers. Patients with periodontitis may have elevated circulating levels of specific inflammatory markers that can be correlated to the severity of the disease. The purpose of this study was to evaluate whether differences in the serum levels of inflammatory biomarkers are differentially expressed in healthy and periodontitis patients. Twenty-five patients (8 healthy patients and 17 chronic periodontitis patients) were enrolled in the study. A 15 mL blood sample was used for identification of the inflammatory markers, with a human inflammatory flow cytometry multiplex assay. Among 24 assessed cytokines, only 3 (RANTES, MIG and Eotaxin) were statistically different between groups (p<0.05). In conclusion, some of the selected markers of inflammation are differentially expressed in healthy and periodontitis patients. Cytokine profile analysis may be further explored to distinguish the periodontitis patients from the ones free of disease and also to be used as a measure of risk. The present data, however, are limited and larger sample size studies are required to validate the findings of the specific biomarkers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the most important properties of artificial teeth is the abrasion wear resistance, which is determinant in the maintenance of the rehabilitation's occlusal pattern. OBJECTIVES: This in vitro study aims to evaluate the abrasion wear resistance of 7 brands of artificial teeth opposed to two types of antagonists. MATERIAL AND METHODS: Seven groups were prepared with 12 specimens each (BIOLUX & BL, TRILUX & TR, BLUE DENT & BD, BIOCLER & BC, POSTARIS & PO, ORTHOSIT & OR, GNATHOSTAR & GN), opposed to metallic (M & nickel-chromium alloy), and to composite antagonists (C & Solidex indirect composite). A mechanical loading device was used (240 cycles/min, 4 Hz speed, 10 mm antagonist course). Initial and final contours of each specimen were registered with aid of a profile projector (20x magnification). The linear difference between the two profiles was measured and the registered values were subjected to ANOVA and Tukey's test. RESULTS: Regarding the antagonists, only OR (M = 10.45 ± 1.42 µm and C = 2.77 ± 0.69 µm) and BC (M = 6.70 ± 1.37 µm and C = 4.48 ± 0.80 µm) presented statistically significant differences (p < 0.05). Best results were obtained with PO (C = 2.33 ± 0.91 µm and M = 1.78 ± 0.42 µm), followed by BL (C = 3.70 ± 1.32 µm and M = 3.70 ± 0.61 µm), statistically similar for both antagonists (p>0.05). Greater result variance was obtained with OR, which presented the worse results opposed to Ni-Cr (10.45 ± 1.42 µm), and results similar to the best ones against composite (2.77 ± 0.69 µm). CONCLUSIONS: Within the limitations of this study, it may be concluded that the antagonist material is a factor of major importance to be considered in the choice of the artificial teeth to be used in the prosthesis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article reports the case of a 55-year-old female patient who presented with unsatisfactory temporary crowns in the right mandibular premolars and molars, and a premolar-to-molar fixed partial denture in the left side. The clinical and radiographic examinations revealed a fracture of the left first premolar that was a retainer of the fixed partial denture and required extraction. Initially, the acrylic resin crowns were replaced by new ones, and a provisional RPD was made using acrylic resin and orthodontic wire clasps to resolve the problem arising from the loss of the fixed partial denture. Considering the patient's high esthetic demands, the treatment options for the definitive prosthetic treatment were discussed with her and rehabilitation with implant-supported dentures was proposed because the clinical conditions of the residual alveolar ridge were suitable for implant installation, and the patient's general health was excellent. However, the patient did not agree because she knew of a failed case of implant-retained denture in a diabetic individual and was concerned. The patient was fully informed that implant installation was the best indication for her case, but the arguments were not sufficient to change her decision. The treatment possibilities were presented and the patient opted for a clasp-retained removable partial denture (RPD) associated with the placement of crowns in the pillar teeth. The temporary RPD was replaced by the definitive RPD constructed subsequently. Although RPD was not the first choice, satisfactory esthetic and functional outcomes were achieved, overcaming the patient's expectations. This case report illustrates that the dentist must be prepared to deal with situations where, for reasons that cannot be managed, the patient does not accept the treatment considered as the most indicated for his/her case. Alternatives must be proposed and the functional and esthetic requirements must be fulfilled in the best possible manner.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

From January to December 2006, 92 Escherichia coli isolates from 25 diarrheic dogs were analyzed by screening for the presence of adhesin-encoding genes (pap, sfa, afa), hemolysin and aerobactin genes. Virulence gene frequencies detected in those isolates were: 12% pap, 1% sfa, 10% hemolysin and 6.5% aerobactin. Ten isolates were characterized as extraintestinal pathogenic E. coli (ExPEC) strains; all showed a multidrug resistance phenotype that may represent a reason for concern due the risk of dissemination of antimicrobial resistant genes to the microbiota of human beings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to compare the completion rates and performance of the Brazilian version of the Oral Health Impact Profile (OHIP14) when applied as an interview or in its original self-reported form. A convenience sample of 74 adult patients was selected in a Dental Clinic (University of Araras, Brazil). One examiner administered the instrument in both formats to participants with an interval of 2 weeks between each administration. Data about dental health condition and socioeconomic status were collected and associated with total OHIP14 scores in both formats using linear regression analyses. No differences were found in the total scores and in each subscale of the OHIP14 according to the form of administration. Higher values of completion were found in the interview format. More severe impacts were recorded in the interview format than in the questionnaire format. Higher values of total OHIP-14 scores in both formats were related to the presence of dental caries. Total OHIP14 scores were not influenced by the method of administration. However, the use of the OHIP14 in the questionnaire format may result in lower completion rates and loss of data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present work was to characterize changes in the protein profile throughout seed development in O. catharinensis, a recalcitrant species, by two-dimensional gel electrophoresis. Protein extraction was undertaken by using a thiourea/urea buffer, followed by a precipitation step with 10% TCA. Comparative analysis during seed development showed that a large number of proteins were exclusively detected in each developmental stage. The cotyledonary stage, which represents the transition phase between embryogenesis and the beginning of metabolism related to maturation, presents the highest number of stage-specific spots. Protein identification, through MS/MS analysis, resulted in the identification of proteins mainly related to oxidative metabolism and storage synthesis. These findings contribute to a better understanding of protein metabolism during seed development in recalcitrant seeds, besides providing information on established markers that could be useful in defining and improving somatic embryogenesis protocols, besides monitoring the development of somatic embryos in this species.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo deste estudo foi investigar o efeito do envelhecimento na sensibilidade a frequências angulares com luminância fotópica (42,6cd/m²). Foram mensuradas curvas de sensibilidade ao contraste em oito adultos jovens (20-29 anos) e oito idosos (60-70 anos) por meio do método psicofísico da escolha forçada. Todos os participantes estavam livres de doenças oculares identificáveis e tinham acuidade visual normal. Os resultados mostraram que o grupo de idosos apresentou alteração significante na faixa de frequências baixas e altas. Concluiu-se que o envelhecimento parece afetar o processamento de frequências angulares baixas e altas em condições de luminância fotópica.