853 resultados para fracture thresholds


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Teeth are brittle and highly susceptible to cracking. We propose that observations of such cracking can be used as a diagnostic tool for predicting bite force and inferring tooth function in living and fossil mammals. Laboratory tests on model tooth structures and extracted human teeth in simulated biting identify the principal fracture modes in enamel. Examination of museum specimens reveals the presence of similar fractures in a wide range of vertebrates, suggesting that cracks extended during ingestion or mastication. The use of ‘fracture mechanics’ from materials engineering provides elegant relations for quantifying critical bite forces in terms of characteristic tooth size and enamel thickness. The role of enamel microstructure in determining how cracks initiate and propagate within the enamel (and beyond) is discussed. The picture emerges of teeth as damage-tolerant structures, full of internal weaknesses and defects and yet able to contain the expansion of seemingly precarious cracks and fissures within the enamel shell. How the findings impact on dietary pressures forms an undercurrent of the study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study examines the inter-relation between enamel morphology and crack resistance by sectioning extracted human molars after loading to fracture. Cracks appear to initiate from tufts, hypocalcified defects at the enamel–dentin junction, and grow longitudinally around the enamel coat to produce failure. Microindentation corner cracks placed next to the tufts in the sections deflect along the tuft interfaces and occasionally penetrate into the adjacent enamel. Although they constitute weak interfaces, the tufts are nevertheless filled with organic matter, and appear to be stabilized against easy extension by self-healing, as well as by mutual stress-shielding and decussation, accounting at least in part for the capacity of tooth enamel to survive high functional forces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An experimental simulation study is made to determine the effects of occlusal wear on the capacity of teeth to resist fracture. Tests are carried out on model dome structures, using glass shells to represent enamel and epoxy filler to represent dentin. The top of the domes are ground and polished to produce flat surfaces of prescribed depths relative to shell thickness. The worn surfaces are then loaded axially with a hard sphere, or a hard or soft flat indenter, to represent extremes of food contacts. The loads required to drive longitudinal cracks around the side walls of the enamel to failure are measured as a function of relative wear depth. It is shown that increased wear can inhibit or enhance load-bearing capacity, depending on the nature of the contact. The results are discussed in the context of biological evolutionary pressures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a novel technique to create a computerized fluoroscopy with zero-dose image updates for computer-assisted fluoroscopy-based close reduction and osteosynthesis of diaphyseal fracture of femurs. With the novel technique, repositioning of bone fragments during close fracture reduction will lead to image updates in each acquired imaging plane, which is equivalent to using several fluoroscopes simultaneously from different directions but without any X-ray radiation. Its application facilitates the whole fracture reduction and osteosynthesis procedure when combining with the existing leg length and antetorsion restoration methods and may result in great reduction of the X-ray radiation to the patient and to the surgical team. In this paper, we present the approach for achieving such a technique and the experimental results with plastic bones.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To compare the prediction of hip fracture risk of several bone ultrasounds (QUS), 7062 Swiss women > or =70 years of age were measured with three QUSs (two of the heel, one of the phalanges). Heel QUSs were both predictive of hip fracture risk, whereas the phalanges QUS was not. INTRODUCTION: As the number of hip fracture is expected to increase during these next decades, it is important to develop strategies to detect subjects at risk. Quantitative bone ultrasound (QUS), an ionizing radiation-free method, which is transportable, could be interesting for this purpose. MATERIALS AND METHODS: The Swiss Evaluation of the Methods of Measurement of Osteoporotic Fracture Risk (SEMOF) study is a multicenter cohort study, which compared three QUSs for the assessment of hip fracture risk in a sample of 7609 elderly ambulatory women > or =70 years of age. Two QUSs measured the heel (Achilles+; GE-Lunar and Sahara; Hologic), and one measured the heel (DBM Sonic 1200; IGEA). The Cox proportional hazards regression was used to estimate the hazard of the first hip fracture, adjusted for age, BMI, and center, and the area under the ROC curves were calculated to compare the devices and their parameters. RESULTS: From the 7609 women who were included in the study, 7062 women 75.2 +/- 3.1 (SD) years of age were prospectively followed for 2.9 +/- 0.8 years. Eighty women reported a hip fracture. A decrease by 1 SD of the QUS variables corresponded to an increase of the hip fracture risk from 2.3 (95% CI, 1.7, 3.1) to 2.6 (95% CI, 1.9, 3.4) for the three variables of Achilles+ and from 2.2 (95% CI, 1.7, 3.0) to 2.4 (95% CI, 1.8, 3.2) for the three variables of Sahara. Risk gradients did not differ significantly among the variables of the two heel QUS devices. On the other hand, the phalanges QUS (DBM Sonic 1200) was not predictive of hip fracture risk, with an adjusted hazard risk of 1.2 (95% CI, 0.9, 1.5), even after reanalysis of the digitalized data and using different cut-off levels (1700 or 1570 m/s). CONCLUSIONS: In this elderly women population, heel QUS devices were both predictive of hip fracture risk, whereas the phalanges QUS device was not.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To compare analgesic efficacy of preoperative versus postoperative administration of carprofen and to determine, if preincisional mepivacaine epidural anesthesia improves postoperative analgesia in dogs treated with carprofen. STUDY DESIGN: Blind, randomized clinical study. ANIMALS: Dogs with femoral (n=18) or pelvic (27) fractures. METHODS: Dogs were grouped by restricted randomization into 4 groups: group 1 = carprofen (4 mg/kg subcutaneously) immediately before induction of anesthesia, no epidural anesthesia; group 2 = carprofen immediately after extubation, no epidural anesthesia; group 3 = carprofen immediately before induction, mepivacaine epidural block 15 minutes before surgical incision; and group 4 = mepivacaine epidural block 15 minutes before surgical incision, carprofen after extubation. All dogs were administered carprofen (4 mg/kg, subcutaneously, once daily) for 4 days after surgery. Physiologic variables, nociceptive threshold, lameness score, pain, and sedation (numerical rating scale [NRS], visual analog scale [VAS]), plasma glucose and cortisol concentration, renal function, and hemostatic variables were measured preoperatively and at various times after surgery. Dogs with VAS pain scores >30 were administered rescue analgesia. RESULTS: Group 3 and 4 dogs had significantly lower pain scores and amount of rescue analgesia compared with groups 1 and 2. VAS and NRS pain scores were not significantly different among groups 1 and 2 or among groups 3 and 4. There was no treatment effect on renal function and hemostatic variables. CONCLUSIONS: Preoperative carprofen combined with mepivacaine epidural anesthesia had superior postoperative analgesia compared with preoperative carprofen alone. When preoperative epidural anesthesia was performed, preoperative administration of carprofen did not improve postoperative analgesia compared with postoperative administration of carprofen. CLINICAL RELEVANCE: Preoperative administration of systemic opioid agonists in combination with regional anesthesia and postoperative administration of carprofen provides safe and effective pain relieve in canine fracture repair.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Lhassa Apso is presented in emergency after having been injured by another dog. It was suffering from a mandibular fracture. The clinical exam revealed generalized and excessive mobility of the whole dentition. Radiographs showed generalized jaw bone demineralisation. A blood sample was analysed and revealed chronic renal disease. We came to the conclusion that this dog was suffering from secondary renal hyperparathyroidism. The hypocalcified bone was so thin that a slight trauma induced the mandibular fracture.