975 resultados para femtosecond optical heterodyne detection of optical Kerr


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes the main parameters - contrast, spatial resolution, and thermal sensitivity - which define the performance of any stand-off imaging system. The origin of the signature for both metal and dielectric objects hidden under clothing in the frequency range from 100 GHz to 500 GHz is discussed. At 100 GHz the signature is dominated by reflection whilst at 500 GHz it is dominated by emission. A 94-GHz-passive millimetre-wave imaging system has been designed and fabricated to image objects under clothing. This imager is based on a Schmidt camera folded using polarisation techniques.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The techniques and technologies currently being investigated to detect weapons and contraband concealed on persons under clothing are reviewed. The basic phenomenology of the atmosphere and materials that must be understood in order to realize such a system are discussed. The component issues and architectural designs needed to realize systems are outlined. Some conclusions with respect to further technology developments are presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Single nucleotide polymorphisms within a sequence of a gene associated with prostate cancer were identified using oligodeoxynucleotide probe sequences bearing internal anthracene fluorophores proximal to the SNP site. Depending upon the nature of the synthesised target sequences, probe-target duplex formation could lead to enhanced or attenuated fluorescence emission from the anthracene, enabling detection of a proximal base-pair as either matching or mismatching. © 2011 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present the ground-based detection of the secondary eclipse of the transiting exoplanet WASP-19b. The observations were made in the Sloan z' band using the ULTRACAM triple-beam CCD camera mounted on the New Technology Telescope. The measurement shows a 0.088% ± 0.019% eclipse depth, matching previous predictions based on H- and K-band measurements. We discuss in detail our approach to the removal of errors arising due to systematics in the data set, in addition to fitting a model transit to our data. This fit returns an eclipse center, T 0, of 2455578.7676 HJD, consistent with a circular orbit. Our measurement of the secondary eclipse depth is also compared to model atmospheres of WASP-19b and is found to be consistent with previous measurements at longer wavelengths for the model atmospheres we investigated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Eighteen patients with a variety of non-gastrointestinal symptoms were incidentally found to have circulating antireticulin antibody and on subsequent testing were also positive for antigliadin antibody. They prospectively underwent jejunal biopsy to determine whether or not they had coeliac disease. Their age range was 21-79 years (mean 42 years). Enteropathy was present in 13 (72 per cent) and was always associated with circulating IgA antigliadin antibody. Enteropathy was not present in the five cases who had only IgG antibody. Clinical improvement occurred in eight of 11 patients who complied with a gluten-free diet and was paralleled by an improvement in the mucosal histology in seven of eight who were re-biopsied. The most remarkable cases were two patients who presented with severe debility and no apparent haematological or biochemical abnormalities, and who subsequently made a dramatic recovery on a gluten-free diet. It is concluded that antireticulin antibody detected by routine autoantibody screening and confirmed to have IgA antigliadin antibody specificity is a useful indicator of an otherwise undiagnosed enteropathy. This serves to emphasize that the condition can sometimes be associated with atypical features and significant morbidity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conventional methods of detecting groundwater flow zones in open boreholes installed in fractured bedrock aquifers rely on either contrasts in water quality or on significant rates of vertical flow. In low productivity boreholes these methods have proced of limited value. Tracer tests completed in six low productivity bedrock boreholes installed into fresh Precambrian crystalline bedrock revealed measurable dilution, despite very low tranmissivities. Fluorescent tracer profiles generated during discharge pumping permitted identification of the principle zones contributing to flow. High resolution acoustic televiewer strike and dip measurements of fractures corresponding to these zones revealed a consistent pattern of regional lineament trends and suggested a strongly anisotropic flow pattern in bedrock.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A replica plate screening technique, based on the acid molybdate assay for detection of phosphate has been developed to permit the detection of microorganisms capable of mineralizing organophosphonates. The method was further adapted as the basis of an activity stain for the detection of the carbon - phosphorus bond cleavage enzyme phosphonoacetate hydrolase in PAGE gels.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Paralytic shellfish poisoning is a toxic syndrome described in humans following the ingestion of seafood contaminated with saxitoxin and/or its derivatives. The presence of these toxins in shellfish is considered an important health threat and their levels in seafood destined to human consumption are regulated in many countries, as well as the levels of other chemically unrelated toxins. We studied the feasibility of immunodetection of saxitoxin and its analogs using a solid-phase microsphere assay coupled to flow cytometry detection in a Luminex 200 system. The technique consists of a competition assay where the toxins in solution compete with bead-bound saxitoxin for binding to an antigonyautoxin 2/3 monoclonal antibody (GT-13A). The assay allowed the detection of saxitoxin both in buffer and mussel extracts in the range of 2.2-19.7 ng/mL (IC(20)-IC(80)). Moreover, the assay cross-reactivity with other toxins of the group is similar to previously published immunoassays, with adequate detection of most analogs except N-1 hydroxy analogs. The recovery rate of the assay for saxitoxin was close to 100%. This microsphere-based immunoassay is suitable to be used as a screening method, detecting saxitoxin from 260 to 2360 µg/kg. This microsphere/flow cytometry system provided similar sensitivities to previously published immunoassays and provides a solid background for the development of easy, flexible multiplexing of toxin detection in one sample.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coccidiostats are the only veterinary drugs still permitted to be used as feed additives to treat poultry for coccidiosis. To protect consumers, maximum levels for their presence in food and feed have been set by the European Union (EU). To monitor these coccidiostats, a rapid and inexpensive screening method would be a useful tool. The development of such a screening method, using a flow cytometry-based immunoassay, is described. The assay uses five sets of colour-coded paramagnetic microspheres for the detection of six selected priority coccidiostats. Different coccidiostats, with and without carrier proteins, were covalently coupled onto different bead sets and tested in combination with polyclonal antisera and with a fluorescent-labelled secondary antibody. The five optimal combinations were selected for this multiplex and a simple-to-use sample extraction method was applied for screening blank and spiked eggs and feed samples. A very good correlation (r ranging from 0.995 to 0.999) was obtained with the responses obtained in two different flow cytometers (Luminex 100 and FLEXMAP 3D). The sensitivities obtained were in accordance with the levels set by the EU as the measured limits of detection for narasin/salinomycin, lasalocid, diclazuril, nicarbazin (4,4'-dinitrocarbanilide) and monensin in eggs were 0.01, 0.1, 0.5, 53 and 0.1 µg/kg and in feed 0.1, 0.2, 0.3, 9 and 1.5 µg/kg, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Marine dinoflagellates of the genera Alexandrium are well known producers of the potent neurotoxic paralytic shellfish toxins that can enter the food web and ultimately present a serious risk to public health in addition to causing huge economic losses. Direct coastal monitoring of Alexandrium spp. can provide early warning of potential shellfish contamination and risks to consumers and so a rapid, sensitive, portable and easy-to-use assay has been developed for this purpose using an innovative planar waveguide device. The disposable planar waveguide is comprised of a transparent substrate onto which an array of toxin-protein conjugates is deposited, assembled in a cartridge allowing the introduction of sample, and detection reagents. The competitive assay format uses a high affinity antibody to paralytic shellfish toxins with a detection signal generated via a fluorescently labelled secondary antibody. The waveguide cartridge is analysed by a simple reader device and results are displayed on a laptop computer. Assay speed has been optimised to enable measurement within 15 min. A rapid, portable sample preparation technique was developed for Alexandrium spp. in seawater to ensure analysis was completed within a short period of time. The assay was validated and the LOD and CCß were determined as 12 pg/mL and 20 pg/mL respectively with an intra-assay CV of 11.3% at the CCß and an average recovery of 106%. The highly innovative assay was proven to accurately detect toxin presence in algae sampled from the US and European waters at an unprecedented cell density of 10 cells/L. © 2012 Elsevier B.V. All rights reserved.