964 resultados para external validation
Resumo:
Accurate pain assessment in preterm infants in the neonatal intensive care unit (NICU) is complex. Infants who are born at early gestational ages (GA), and who have had greater early pain exposure, have dampened facial responses which may lead to under-treatment. Since behavioral and physiological responses to pain in infants are often dissociated, using multidimensional scales which combine these indicators into a single score may limit our ability to determine the effects of interventions on each system. Our aim was to design a unidimensional scale which would combine the relatively most specific, individual, behavioral indicators for assessing acute pain in this population. The Behavioral Indicators of Infant Pain (BIIP) combines sleep/wake states, 5 facial actions and 2 hand actions. Ninety-two infants born between 23 and 32 weeks GA were assessed during 3, 1 min Phases of blood collection. Outcome measures included changes in BIIP and in Neonatal Infant Pain Scale (NIPS) scores coded in real time from continuous bedside video recordings; changes in heart rate (HR) were obtained using custom physiological processing software. Scores on the BIIP changed significantly across Phases of blood collection (p
Resumo:
Key stakeholders in the UK charity sector have, in recent years, advocated greater accountability for charity performance. Part of that debate has focussed on the use of conversion ratios as indicators of efficiency, with importance to stakeholders being contrasted with charities’ apparent reluctance to report such measures. Whilst, before 2005, conversion ratios could have been computed from financial statements, changes in the UK charity SORP have radically altered the ability of users to do this. This article explores the impact on the visibility of such information through an analysis of the financial statements of large UK charities before and after the 2005 changes. Overall, the findings suggest that, despite the stated intention of increasing transparency in respect of charity costs, the application of the changes has resulted in charities ‘managing’ the numbers and limiting their disclosures, possibly to the detriment of external stakeholders.
Resumo:
Primary care in the United States is undergoing many changes. Reliable and valid instruments are needed to assess the effects of these changes. The Primary Care Organizational Questionnaire (PCOQ), a 56-item 5-point Likert scale survey that evaluates interactions among members of the clinic/practice and job-related attributes, was administered to clinicians and staff in 36 primary care practices serving paediatric populations in Connecticut. A priori scales were reliable (Cronbach alpha =0.7). Analysis of variance (ANOVA) showed greater heterogeneity across clinics than within clinics for 13 of 15 a priori scales, which were then included in a principal component factor analysis with varimax rotation. Eigenvalue analysis showed nine significant factors, largely similar to the a priori scales, indicating concurrent construct validity. Further research will ascertain the utility of the PCOQ in predicting the effectiveness of primary care practices in implementing disease management programmes. © 2006 Royal Society of Medicine Press.
Resumo:
In recent years external beam radiotherapy (EBRT) has been proposed as a treatment for the wet form of age-related macular degeneration (AMD) where choroidal neovascularization (CNV) is the hallmark. While the majority of pilot (Phase I) studies have reported encouraging results, a few have found no benefit, i.e. EBRT was not found to result in either improvement or stabilization of visual acuity of the treated eye. The natural history of visual loss in untreated CNV of AMD is highly variable. Loss of vision is influenced mainly by the presenting acuity, and size and composition of the lesion, and to a lesser extent by a variety of other factors. Thus the variable outcome reported by the small Phase I studies of EBRT published to date may simply reflect the variation in baseline factors. We therefore obtained information on 409 patients treated with EBRT from eight independent centres, which included details of visual acuity at baseline and at subsequent follow-up visits. Analysis of the data showed that 22.5% and 14.9% of EBRT-treated eyes developed moderate and severe loss of vision, respectively, during an average follow-up of 13 months. Initial visual acuity, which explained 20.5% of the variation in visual loss, was the most important baseline factor studied. Statistically significant differences in loss of vision were observed between centres, after considering the effects of case mix factors. Comparisons with historical data suggested that while moderate visual loss was similar to that of the natural history of the disease, the likelihood of suffering severe visual loss was halved. However, the benefit in terms of maintained/improved vision in the treated eye was modest.
Resumo:
BACKGROUND: Measures that reflect patients' assessment of their health are of increasing importance as outcome measures in randomised controlled trials. The methodological approach used in the pre-validation development of new instruments (item generation, item reduction and question formatting) should be robust and transparent. The totality of the content of existing PRO instruments for a specific condition provides a valuable resource (pool of items) that can be utilised to develop new instruments. Such 'top down' approaches are common, but the explicit pre-validation methods are often poorly reported. This paper presents a systematic and generalisable 5-step pre-validation PRO instrument methodology.
METHODS: The method is illustrated using the example of the Aberdeen Glaucoma Questionnaire (AGQ). The five steps are: 1) Generation of a pool of items; 2) Item de-duplication (three phases); 3) Item reduction (two phases); 4) Assessment of the remaining items' content coverage against a pre-existing theoretical framework appropriate to the objectives of the instrument and the target population (e.g. ICF); and 5) qualitative exploration of the target populations' views of the new instrument and the items it contains.
RESULTS: The AGQ 'item pool' contained 725 items. Three de-duplication phases resulted in reduction of 91, 225 and 48 items respectively. The item reduction phases discarded 70 items and 208 items respectively. The draft AGQ contained 83 items with good content coverage. The qualitative exploration ('think aloud' study) resulted in removal of a further 15 items and refinement to the wording of others. The resultant draft AGQ contained 68 items.
CONCLUSIONS: This study presents a novel methodology for developing a PRO instrument, based on three sources: literature reporting what is important to patient; theoretically coherent framework; and patients' experience of completing the instrument. By systematically accounting for all items dropped after the item generation phase, our method ensures that the AGQ is developed in a transparent, replicable manner and is fit for validation. We recommend this method to enhance the likelihood that new PRO instruments will be appropriate to the research context in which they are used, acceptable to research participants and likely to generate valid data.
Multiscale simulation of nanometric cutting of single crystal copper and its experimental validation
Resumo:
In this paper a multiscale simulation study was carried out in order to gain in-depth understanding of machining mechanism of nanometric cutting of single crystal copper. This study was focused on the effects of crystal orientation and cutting direction on the attainable machined surface quality. The machining mechanics was analyzed through cutting forces, chip formation morphology, generation and evolution of defects and residual stresses on the machined surface. The simulation results showed that the crystal orientation of the copper material and the cutting direction significantly influenced the deformation mechanism of the workpiece materials during the machining process. Relatively lower cutting forces were experienced while selecting crystal orientation family {1 1 1}. Dislocation movements were found to concentrate in front of the cutting chip while cutting on the (1 1 1) surface along the View the MathML source cutting direction thus, resulting in much smaller damaged layer on the machined surface, compared to other orientations. This crystal orientation and cutting direction therefore recommended for nanometric cutting of single crystal copper in practical applications. A nano-scratching experiment was performed to validate the above findings.
Resumo:
Cronobacter (formerly known as Enterobacter sakazakii) is a genus comprising seven species regarded as opportunistic pathogens that can be found in a wide variety of environments and foods, including powdered infant formula (PIF). Cronobacter sakazakii, the major species of this genus, has been epidemiologically linked to cases of bacteremia, meningitis in neonates, and necrotizing enterocolitis, and contaminated PIF has been identified as an important source of infection. Robust and reproducible subtyping methods are required to aid in the detection and investigation, of foodborne outbreaks. In this study, a pulsed-field gel electrophoresis (PFGE) protocol was developed and validated for subtyping Cronobacter species. It was derived from an existing modified PulseNet protocol, wherein XbaI and SpeI were the primary and secondary restriction enzymes used, generating an average of 14.7 and 20.3 bands, respectively. The PFGE method developed was both reproducible and discriminatory for subtyping Cronobacter species.
Resumo:
This paper contributes to and expands on the Nakagami-m phase model. It derives exact, closed-form expressions for both the phase cumulative distribution function and its inverse. In addition, empirical first- and second-order statistics obtained from measurements conducted in a body-area network scenario were used to fit the phase probability density function, the phase cumulative distribution function, and the phase crossing rate expressions. Remarkably, the unlikely shapes of the phase statistics, as predicted by the theoretical formulations, are actually encountered in practice.
Resumo:
Next Generation Sequencing (NGS) has the potential of becoming an important tool in clinical diagnosis and therapeutic decision-making in oncology owing to its enhanced sensitivity in DNA mutation detection, fast-turnaround of samples in comparison to current gold standard methods and the potential to sequence a large number of cancer-driving genes at the one time. We aim to test the diagnostic accuracy of current NGS technology in the analysis of mutations that represent current standard-of-care, and its reliability to generate concomitant information on other key genes in human oncogenesis. Thirteen clinical samples (8 lung adenocarcinomas, 3 colon carcinomas and 2 malignant melanomas) already genotyped for EGFR, KRAS and BRAF mutations by current standard-of-care methods (Sanger Sequencing and q-PCR), were analysed for detection of mutations in the same three genes using two NGS platforms and an additional 43 genes with one of these platforms. The results were analysed using closed platform-specific proprietary bioinformatics software as well as open third party applications. Our results indicate that the existing format of the NGS technology performed well in detecting the clinically relevant mutations stated above but may not be reliable for a broader unsupervised analysis of the wider genome in its current design. Our study represents a diagnostically lead validation of the major strengths and weaknesses of this technology before consideration for diagnostic use.
Resumo:
The development of accurate structural/thermal numerical models of complex systems, such as aircraft fuselage barrels, is often limited and determined by the smallest scales that need to be modelled. The development of reduced order models of the smallest scales and consequently their integration with higher level models can be a way to minimise the bottle neck present, while still having efficient, robust and accurate numerical models. In this paper a methodology on how to develop compact thermal fluid models (CTFMs) for compartments where mixed convection regimes are present is demonstrated. Detailed numerical simulations (CFD) have been developed for an aircraft crown compartment and validated against experimental data obtained from a 1:1 scale compartment rig. The crown compartment is defined as the confined area between the upper fuselage and the passenger cabin in a single aisle commercial aircraft. CFD results were utilised to extract average quantities (temperature and heat fluxes) and characteristic parameters (heat transfer coefficients) to generate CTFMs. The CTFMs have then been compared with the results obtained from the detailed models showing average errors for temperature predictions lower than 5%. This error can be deemed acceptable when compared to the nominal experimental error associated with the thermocouple measurements.
The CTFMs methodology developed allows to generate accurate reduced order models where accuracy is restricted to the region of Boundary Conditions applied. This limitation arises from the sensitivity of the internal flow structures to the applied boundary condition set. CTFMs thus generated can be then integrated in complex numerical modelling of whole fuselage sections.
Further steps in the development of an exhaustive methodology would be the implementation of a logic ruled based approach to extract directly from the CFD simulations numbers and positions of the nodes for the CTFM.
Resumo:
Purpose: To evaluate the clinical and histological side effects of a prototype stereotactic radiotherapy system delivering microcollimated external beam radiation through pars plana in porcine eyes.
Methods: Five Yucatan mini-swine (10 eyes) were randomized to five treatment groups. Eight eyes were dosed with X-ray radiation on Day 1, and two eyes served as untreated controls. Treated eyes received doses up to 60 Gy to the retina and up to 130 Gy to the sclera using single or overlapping beams. The treatment beams were highly collimated such that the diameter was approximately 2.5 mm on the sclera and 3 mm on the retinal surface. Fundus photography, fluorescein angiography (FA), and spectral domain optical coherence tomography (SD-OCT) were obtained on days 7, 30, 60, and 110. Images were examined by a masked grader and evaluated for abnormalities. Animals were sacrificed on day 111 and gross and histopathological analysis was conducted.
Results: Histological and gross changes to eye structures including conjunctiva and lens were minimal at all doses. Fundus, FA, and SD-OCT of the targeted region failed to disclose any abnormality in the control or 21 Gy treated animals. In the 42 and 60 Gy animals, hypopigmented spots were noted after treatment on clinical exam, and corresponding hyperfluorescent staining was seen in late frames. No evidence of choroidal hypoperfusion was seen. The histological specimens from the 60 Gy animals showed photoreceptor loss and displacement of cone nuclei.
Conclusion: Transcleral stereotactic radiation dosing in porcine eyes can be accomplished with no significant adverse events as doses less than 42 Gy.