879 resultados para column chromatography


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The venom of Crotalus durissus terrificus snakes presents various substances, including a serine protease with thrombin-like activity, called gyroxin, that clots plasmatic fibrinogen and promote the fibrin formation. The aim of this study was to purify and structurally characterize the gyroxin enzyme from Crotalus durissus terrificus venom. For isolation and purification, the following methods were employed: gel filtration on Sephadex G75 column and affinity chromatography on benzamidine Sepharose 6B; 12% SDS-PAGE under reducing conditions; N-terminal sequence analysis; cDNA cloning and expression through RT-PCR and crystallization tests. Theoretical molecular modeling was performed using bioinformatics tools based on comparative analysis of other serine proteases deposited in the NCBI (National Center for Biotechnology Information) database. Protein N-terminal sequencing produced a single chain with a molecular mass of similar to 30 kDa while its full-length cDNA had 714 bp which encoded a mature protein containing 238 amino acids. Crystals were obtained from the solutions 2 and 5 of the Crystal Screen Kit (R), two and one respectively, that reveal the protein constitution of the sample. For multiple sequence alignments of gyroxin-like B2.1 with six other serine proteases obtained from snake venoms (SVSPs), the preservation of cysteine residues and their main structural elements (alpha-helices, beta-barrel and loops) was indicated. The localization of the catalytic triad in His57, Asp102 and Ser198 as well as S1 and S2 specific activity sites in Thr193 and Gli215 amino acids was pointed. The area of recognition and cleavage of fibrinogen in SVSPs for modeling gyroxin B2.1 sequence was located at Arg60, Arg72, Gln75, Arg81, Arg82, Lis85, Glu86 and Lis87 residues. Theoretical modeling of gyroxin fraction generated a classical structure consisting of two alpha-helices, two beta-barrel structures, five disulfide bridges and loops in positions 37, 60, 70, 99, 148, 174 and 218. These results provided information about the functional structure of gyroxin allowing its application in the design of new drugs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tuberculosis is a serious disease, but curable in practically 100% of new cases, since complied the principles of modern chemotherapy. Isoniazid (ISN), Rifampicin (RIF), Pyrazinamide (PYR) and Chloride Ethambutol (ETA) are considered first line drugs in the treatment of tuberculosis, by combining the highest level of efficiency with acceptable degree of toxicity. Concerning USP 33 - NF28 (2010) the chromatography analysis to 3 of 4 drugs (ISN, PYR and RIF) last in average 15 minutes and 10 minutes more to obtain the 4th drug (ETA) using a column and mobile phase mixture different, becoming its industrial application unfavorable. Thus, many studies have being carried out to minimize this problem. An alternative would use the UFLC, which is based with the same principles of HPLC, however it uses stationary phases with particles smaller than 2 μm. Therefore, this study goals to develop and validate new analytical methods to determine simultaneously the drugs by HPLC/DAD and UFLC/DAD. For this, a analytical screening was carried out, which verified that is necessary a gradient of mobile phase system A (acetate buffer:methanol 94:6 v/v) and B (acetate buffer:acetonitrile 55:45 v/v). Furthermore, to the development and optimization of the method in HPLC and UFLC, with achievement of the values of system suitability into the criteria limits required for both techniques, the validations have began. Standard solutions and tablets test solutions were prepared and injected into HPLC and UFLC, containing 0.008 mg/mL ISN, 0.043 mg/mL PYR, 0.030 mg.mL-1 ETA and 0.016 mg/mL RIF. The validation of analytical methods for HPLC and UFLC was carried out with the determination of specificity/selectivity, analytical curve, linearity, precision, limits of detection and quantification, accuracy and robustness. The methods were adequate for determination of 4 drugs separately without interfered with the others. Precise, due to the fact of the methods demonstrated since with the days variation, besides the repeatability, the values were into the level required by the regular agency. Linear (R> 0,99), once the methods were capable to demonstrate results directly proportional to the concentration of the analyte sample, within of specified range. Accurate, once the methods were capable to present values of variation coefficient and recovery percentage into the required limits (98 to 102%). The methods showed LOD and LOQ very low showing the high sensitivity of the methods for the four drugs. The robustness of the methods were evaluate, facing the temperature and flow changes, where they showed robustness just with the preview conditions established of temperature and flow, abrupt changes may influence with the results of methods

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The synthetic guanylhydrazones WE010 (3,5-di-tert-butil-4-hidroxibenzaldehyde-guanylhydrazone), WE014 (4-bifenilcarboxialdehydeguanylhydrazone) and WE017 (3,4-diclorobenzaldehydeguanylhydrazone) showed high cytotoxic activity in terms of percentage inhibition of cancer cells growth. However, further progress in the development of these drug candidates requires precise and convenient methods for their qualitative and quantitative analyses. The aim of this study was to develop and validate High Performance Liquid Chromatography with diode-array detection (HPLC-DAD) and Ultra Fast Liquid Chromatography with diode-array detection (UFLC-DAD) methods suitable for as simultaneous as isolated determination of studied guanylhydrazones, based on the optimization of chromatographic parameters and obtaining reduced detection times. The chromatographic analyses of analytes by HPLC were performed on C18 ACE analytical column (150 mm x 4.6 mm), with a particle size of 5.0 μm. Among all the conditions assayed, the best results of separation were obtained with a mixture of methanol:water (60:40, v/v) as the mobile phase at a flow rate 1.5mL/min and pH of 3.5 adjusted at acetic acid. The UFLC method was developed by experimetal desing techniques in order to find optimal chromatographic analytical conditions, which were achieved on XR-ODS analytical column (50 mm x 3.0 mm), with a particle size of 2,2 μm, maintained at 25 ºC. The mobile phase was consisted of methanol:water (65:35, v/v) with 0.1% triethylamine (TEA) and pH of 3.5 adjusted at acetic acid, at a flow rate 0.5 mL/min. The procedure were validated following evaluating parameters such as specificity, linearity, limits of detection (LD) and quantification (LQ), precision, accuracy and robustness, giving results within the acceptable range. Although the UFLC method shows better sensitivity (lower values of LD and LQ), robustness (lower rates of relative standard deviation) and minimize spending time and solvent, both developed methods were adequately applied to the analysis of guanylhydrazones molecules, may be used in routine of quality control laboratories. Keywords: guanylhydrazones, HPLC/DAD, UFLC/DAD, validation of analitical method

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present study we evaluated the precision of the ELISA method to quantify caffeine in human plasma and compared the results with those obtained by gas chromatography. A total of 58 samples were analyzed by gas chromatography using a nitrogen-phosphorus detector and routine techniques. For the ELISA test, the samples were diluted to obtain a concentration corresponding to 50% of the absorbance of the standard curve. To determine whether the proximity between the I50 of the standard curve and that of the sample would bring about a more precise result, the samples were divided into three blocks according to the criterion of difference, in modulus, of the I50 of the standard curve and of the I50 of the sample. The samples were classified into three groups. The first was composed of 20 samples with I50 up to 1.5 ng/ml, the second consisted of 21 samples with I50 ranging from 1.51 to 3 ng/ml, and the third of 17 samples with I50 ranging from 3.01 to 13 ng/ml. The determination coefficient (R² = 0.999) showed that the data obtained by gas chromatography represented a reliable basis. The results obtained by ELISA were also reliable, with an estimated Pearson correlation coefficient of 0.82 between the two methods. This coefficient for the different groups (0.88, 0.79 and 0.49 for groups 1, 2 and 3, respectively) showed greater reliability for the test with dilutions closer to I50.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Expanded Bed Adsorption plays an important role in the downstream processing mainly for reducing costs as well as steps besides could handling cells homogenates or fermentation broth. In this work Expanded Bed Adsorption was used to recover and purify whey proteins from coalho cheese manufacture using Streamline DEAE and Streamline SP both ionic resins as well as a hydrophobic resin Streamline Phenyl. A column of 2.6 cm inner diameter with 30 cm in height was coupled to a peristaltic pump. Hydrodynamics study was carried out with the three resins using Tris-HCl buffer in concentration of 30, 50 and 70 mM, with pH ranging from 7.0 to 8.0. In this case, assays of the expansion degree as well as Residence Time Distribution (RTD) were carried out. For the recovery and purification steps, a whey sample of 200 mL, was submitted to a column with 25mL of resin previously equilibrated with Tris/HCl (50 mM, pH 7.0) using a expanded bed. After washing, elution was carried out according the technique used. For ionic adsorption elution was carried out using 100 mL of Tris/HCl (50 mM, pH 7.0 in 1M NaCl). For Hydrophobyc interaction elution was carried out using Tris/HCl (50 mM, pH 7.0). Adsorption runs were carried out using the three resins as well as theirs combination. Results showed that for hydrodynamics studies a linear fit was observed for the three resins with a correlation coefficient (R2) about 0.9. In this case, Streamline Phenyl showed highest expansion degree reaching an expansion degree (H0/H) of 2.2. Bed porosity was of 0.7 when both resins Streamline DEAE and Streamline SP were used with StremLine Phenyl showing the highest bed porosity about 0.75. The number of theorical plates were 109, 41.5 and 17.8 and the axial dipersion coefficient (Daxial) were 0.5, 1.4 and 3.7 x 10-6 m2/s, for Streamline DEAE, Streamline SP and Streamline Phenyl, respectively. Whey proteins were adsorved fastly for the three resins with equilibrium reached in 10 minutes. Breakthrough curves showed that most of proteins stays in flowthrough as well as washing steps with 84, 77 and 96%, for Streamline DEAE, Streamline SP and Streamline Phenyl, respectively. It was observed protein peaks during elution for the three resins used. According to these peaks were identified 6 protein bands that could probably be albumin (69 KDa), lactoferrin (76 KDa), lactoperoxidase (89 KDa), β-lactoglobulin (18,3 KDa) e α-lactoalbumin (14 KDa), as well as the dimer of beta-lactoglobulin. The combined system compound for the elution of Streamline DEAE applied to the Streamline SP showed the best purification of whey proteins, mainly of the α-lactoalbumina

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pouco se conhece sobre os epítopos derivados de promastigotas metacíclicos de Leishmania que são importantes para a regulação ou destruição do parasita, como alvos de ação imunológica no hospedeiro vertebrado. Neste estudo, nós investigamos um método alternativo para obter promastigotas metacíclicos de Leishmania major, pela avaliação do curso da infecção e reação de hipersensibilidade do tipo retardado (HTR) em hospedeiros resistentes e susceptíveis. Promastigotas não-infectantes (procíclicos) de L. major, recentemente isolados de amastigotas, foram selecionados pela adesão a colunas de lã de vidro negativamente carregadas, enquanto que promastigotas metacíclicos não se aderem à coluna e podem ser recuperados com facilidade. Condições ótimas de cromatografia foram validadas por análise estatística. O rendimento médio de parasitas obtidos após separação em colunas de lã de vidro e a viabilidade dos promastigotas foram estimados por microscopia óptica. Os promastigotas metacíclicos tiveram um rendimento médio de 43,5% a 57,5%. Camundongos BALB/c (susceptíveis) e camundongos C57BL/6 (resistentes) apresentaram padrões distintos de lesões cutâneas, os primeiros com lesões mais agressivas, induzidas por promastigotas metacíclicos. As respostas à reação de HTR foram maiores nos grupos de camundongos C57BL/6, submetidos à infecção com promastigotas metacíclicos. Estes resultados indicam que o novo método poderia ser integrado aos protocolos existentes para estudar a metaciclogênese de parasitas do gênero Leishmania in vivo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and rapid method was developed for the determination of amfepramone hydrochloride, fenprorex, and diazepam in capsules using high performance liquid chromatography (HPLC) with UV detection. This procedure provided conditions for the separation of the active ingredient from the complex matrices of the dosage forms by extraction in methanol. Isocratic reversed phase chromatography was performed using acetonitrile, methanol, and aqueous 0,1% ammonium carbonate (50:10:40) as a mobile phase, LiChrospher 100 RP 18 column (125 x 5 mm id, 5 mu m), a column temperature of 25 +/- 1 degrees C and detection at 230 nm.The calibration curves were linear over a wide concentration range (20-2000 mu g.mL(-1) to amfepramone hydrochloride, 8-800 mu g.mL(-1) to fenproporex, and 4-200 mu g.mL(-1) to diazepam) and good analytical recovery (87.1 to 107.8%) was obtained. The method is accurate and precise, as well as having advantages such as simplicity and short duration of analysis. Twenty samples of pharmaceutical preparations labelled as natural products were analysed. Anorectics and diazepam, were detected in 40% of the samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Propolis obtained from honeybee hives has been widely used in medicine, cosmetics, and industry due to its versatile biological activities (antioxidant, antimicrobial, fungicidal, antiviral, antiulcer, immunostimulating, and cytostatic). These activities are mainly attributed to the presence of flavonoids in propolis, which points out the interest in quantifying these constituents in propolis preparations, as well as validation of analytical methodologies. High-performance liquid chromatography (HPLC) methods have been reported to quantify isolated flavonoids or these compounds in complex biological matrices, such as herbal raw materials and extractive preparations. An efficient, precise, and reliable method was developed for quantification of propolis extractive solution using HPLC with UV detection. The chromatograms were obtained from various gradient elution systems (GES) tested in order to establish the ideal conditions for the analysis of propolis extractive solution, using methanol and water: acetonitrile (97.5 : 2.5, v/v) as mobile phase. Gradient reversed phase chromatography was performed using a stainless steel column (250 x 4.6 mm i.d., 5 mum) filled with Chromsep RP 18 (Varian), column temperature at 30.0 +/- 0.1degreesC and detection at 310 nm. The main validation parameters of the method were also determined. The method showed linearity for chrysin in the range 0.24-2.4 mug mL(-1) with good correlation coefficients (0.9975). Precision and accuracy were determined. The obtained results demonstrate the efficiency of the proposed method. The analytical procedure is reliable and offers advantages in terms of speed and cost of reagents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A sensitive, accurate, reliable and easy method was developed for the quantification of oxamniquine in capsules using high-performance liquid chromatography (HPLC) with UV detection. This technique provided conditions for the separation of the active ingredient from the dosage form by extraction in methanol. Isocratic reversed phase chromatography was performed using methanol, water, and triethanolamine (60:40:0.099, v/v/w) (System C) or methanol, acetonitrile, water and formic acid (40:30:30:0.083, v/v/w) (System D) as mobile phase, a stainless steel column (125 x 4 mm i.d., 5 mum) filled with LiChrospher 100 RP-18 (Merck), column temperature of 28 +/- 2 degreesC and detection at 260 nm. The calibration curves were linear over a wide concentration range (1.0-20.0 mug ml(-1) of oxamniquine) to the Systems C and D with good correlation factor (0.9990 and 0.9982, respectively). The average content obtained were 100.1 +/- 1.5% (System C) and 102.4 +/- 0.8% (System D). The presence of lactose, starch, magnesium stearate and sodium laurylsulphate did not interfere in the results of the analysis. The above findings showed the proposed method to be both simple and added advantage of allowing for fast analysis. (C) 2001 Elsevier B.V. B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Simple and rapid procedures were developed for the quantification of amfepramone hydrochloride and diazepam and mazindol and diazepam in tablets using high performance liquid chromatography (HPLC) with UV detection. These techniques provided conditions for the separation of each active ingredient from the complex matrices of the dosage forms by dilution or extraction in methanol. Isocratic reversed phase chromatography was performed using acetonitrile, methanol, and aqueous 0,1% ammonium carbonate (70:10:20, v/v/v) as a mobile phase, Radial-Pak C-18 column (100 x 8 mm id, 4 mu m), a column temperature of 25+/-1 degrees C and detection at 255 nm. The calibration curves were linear over a wide concentration range (100-1000 mu g.mL(-1) to amfepramone hydrochloride and mazindol and 10-100 mu g.mL(-1) to diazepam) with good correlation factors of 0.9978, 0.9956 and 0.9997 for amfepramone hydrochloride, mazindol, and diazepam, respectively.Mean recoveries obtained from the two kinds of samples ranged from 83.2 to 102.5%, with coefficients of variation ranging from 1.0 to 6.1.These results demonstrated the efficiency of the proposed methods, as well as advantages such as simplicity and short duration of analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)