983 resultados para artéria femoral
Resumo:
Freehand positioning of the femoral drill guide is difficult during hip resurfacing and the surgeon is often unsure of the implant position achieved peroperatively. The purpose of this study was to find out whether, by using a navigation system, acetabular and femoral component positioning could be made easier and more precise. Eighteen patients operated on by the same surgeon were matched by sex, age, BMI, diagnosis and ASA score (nine patients with computer assistance, nine with the regular ancillary). Pre-operative planning was done on standard AP and axial radiographs with CT scan views for the computer-assisted operations. The final position of implants was evaluated by the same radiographs for all patients. The follow-up was at least 1 year. No difference between both groups in terms of femoral component position was observed (p > 0.05). There was also no difference in femoral notching. A trend for a better cup position was observed for the navigated hips, especially for cup anteversion. There was no additional operating time for the navigated hips. Hip navigation for resurfacing surgery may allow improved visualisation and hip implant positioning, but its advantage probably will be more obvious with mini-incisions than with regular incision surgery.
Resumo:
Biofilm formation is a multi-step process influenced by surface properties. We investigated early and mature biofilm of Staphylococcus aureus on 4 different biological calcium phosphate (CaP) bone grafts used for filling bone defects. We investigated standardised cylinders of fresh and fresh-frozen human bone grafts were harvested from femoral heads; processed humanand bovine bone grafts were obtained preformed. Biofilm formation was done in tryptic soy broth (TSB) using S. aureus (ATCC 29213) with static conditions. Biofilm density after 3 h (early biofilm) and 24 h (mature biofilm) was investigated by sonication and microcalorimetry. After 3 h, bacterial density was highest on fresh-frozenandfresh bone grafts. After 24 h, biofilm density was lowest on freshbone grafts (p < 0.001) compared to the other 3 materials, which did not differ quantitatively (p > 0.05). The lowest increase in bacterial density was detected on fresh bone grafts (p < 0.001). Despite normal shaped colonies, we found additional small colonies on the surface of the fresh and fresh-frozen samples by sonication. This was also apparent in microcalorimetric heat-flow curves. The four investigated CaP bone grafts showed minor structural differences in architecture but marked differences concerning serum coverage and the content of bone marrow, fibrous tissue and bone cells. These variations resulted in a decreased biofilm density on freshand fresh-frozenbone grafts after 24 h, despite an increased early biofilm formation and might also be responsible for the variations in colony morphology (small colonies). Detection of small colony variants by microcalorimetry might be a new approach to improve the understanding of biofilm formation.
Resumo:
Both late menarcheal age and low calcium intake (Ca intake) during growth are risk factors for osteoporosis, probably by impairing peak bone mass. We investigated whether lasting gain in areal bone mineral density (aBMD) in response to increased Ca intake varies according to menarcheal age and, conversely, whether Ca intake could influence menarcheal age. In an initial study, 144 prepubertal girls were randomized in a double-blind controlled trial to receive either a Ca supplement (Ca-suppl.) of 850 mg/d or placebo from age 7.9-8.9 yr. Mean aBMD gain determined by dual energy x-ray absorptiometry at six sites (radius metaphysis, radius diaphysis, femoral neck, trochanter, femoral diaphysis, and L2-L4) was significantly (P = 0.004) greater in the Ca-suppl. than in the placebo group (27 vs. 21 mg/cm(2)). In 122 girls followed up, menarcheal age was recorded, and aBMD was determined at 16.4 yr of age. Menarcheal age was lower in the Ca-suppl. than in the placebo group (P = 0.048). Menarcheal age and Ca intake were negatively correlated (r = -0.35; P < 0.001), as were aBMD gains from age 7.9-16.4 yr and menarcheal age at all skeletal sites (range: r = -0.41 to r = -0.22; P < 0.001 to P = 0.016). The positive effect of Ca-suppl. on the mean aBMD gain from baseline remained significantly greater in girls below, but not in those above, the median of menarcheal age (13.0 yr). Early menarcheal age (12.1 +/- 0.5 yr): placebo, 286 +/- 36 mg/cm(2); Ca-suppl., 317 +/- 46 (P = 0.009); late menarcheal age (13.9 +/- 0.5 yr): placebo, 284 +/- 58; Ca-suppl., 276 +/- 50 (P > 0.05). The level of Ca intake during prepuberty may influence the timing of menarche, which, in turn, could influence long-term bone mass gain in response to Ca supplementation. Thus, both determinants of early menarcheal age and high Ca intake may positively interact on bone mineral mass accrual.
Resumo:
5 to 10% of all fractures present with a delayed union, whereas 1 to 5% progress to a nonunion, which can be defined as a fracture older than 6 months and lacks any potential to heal without any further intervention. Different fracture and patient related risk factors exist, and the management of a nonunion needs a thorough clinical, radiological and biological workup to classify them in one of the two main categories, the viable nonunions that need essentially more stability, usually by a more rigid fixation, and the non-viable nonunions that need essentially a biological stimulation by decortication and bone grafting. This treatment still remains the first choice with bony healing obtained in 85 to 95% of cases, but it also comes along with certain risks, and some valuable alternatives exist if chosen on the basis of rigid criteria.
Resumo:
Background: The RCP is a 14 French collapsable percutaneous cardiovascular support device positioned in the descending part of the thoracic aorta via the femoral artery. A 10 patient first in man study demonstrated device safety and significant improvement in renal function among high risk PCI patients. We now report haemodynamic and renal efficacy in patients with ADHF.Methods: Prospective non randomised study seeking to recruit 20 patients with ADHF with a need for inotropic or mechanical circulatory support with: i) EF < 30% ii)Cardiac index(CI) < 2.2 L / min / m2 Outcome measures included: 1) Cardiac index (CI) 2) Pulmonary Capillary Wedge Pressure (PCWP) 3) Urine output / serum creatinine 4) Vascular / device complications 5) 30 day mortalityResults: INTERIM ANALYSIS (n=12) The mean age of the study group was 64 years, with a mean baseline creatinine of 193 umol/L, eGFR 38 ml/min. The intended RCP treatment period was 24 hours. During RCP treatment there was a significant mean reduction of PCWP at 4 hours of 17% (25 to 21 mmHg p=0.04). Mean CI increased at 12 hours by 11%, though not reaching significance (1.78 to 1.96 L/min/m2 p=0.08). RCP insertion prompted substantial diuresis. Urine output tripled over the first 12 hours compared to baseline (55 ml/hr vs 213 ml/hr p=0.03). This was associated with significantly improved renal function, a 28% reduction in serum creatinine at 12 hours (193 to 151 umol/L p=0.003), and a increase in eGFR from 38 ml/min to 50 ml/min (p=0.0007). 2 patients previously refused cardiac transplantation were reassessed and successfully transplanted within 9 months of RCP treatment on the basis of demonstrable renal reversibility. There were no vascular or device complications. There were 2 deaths at 30 days, one from multi-organ failure and sepsis, and one from intractable heart failure - neither were device related.Conclusion: RCP support in ADHF patients was associated with improved haemodynamics, and an improvement in renal function. The Reitan Catheter Pump may have a role in providing percutaneous cardiovascular and renal support in the acutely decompensated cardiac patient, and may have a role in suggesting renal reversibility in potential cardiac transplant patients. Further data will be reported at recruitment completion.
Resumo:
Activation of the hepatoportal glucose sensors by portal glucose infusion leads to increased glucose clearance and induction of hypoglycemia. Here, we investigated whether glucagon-like peptide-1 (GLP-1) could modulate the activity of these sensors. Mice were therefore infused with saline (S-mice) or glucose (P-mice) through the portal vein at a rate of 25 mg/kg. min. In P-mice, glucose clearance increased to 67.5 +/- 3.7 mg/kg. min as compared with 24.1 +/- 1.5 mg/kg. min in S-mice, and glycemia decreased from 5.0 +/- 0.1 to 3.3 +/- 0.1 mmol/l at the end of the 3-h infusion period. Coinfusion of GLP-1 with glucose into the portal vein at a rate of 5 pmol/kg. min (P-GLP-1 mice) did not increase the glucose clearance rate (57.4 +/- 5.0 ml/kg. min) and hypoglycemia (3.8 +/- 0.1 mmol/l) observed in P-mice. In contrast, coinfusion of glucose and the GLP-1 receptor antagonist exendin-(9-39) into the portal vein at a rate of 0.5 pmol/kg. min (P-Ex mice) reduced glucose clearance to 36.1 +/- 2.6 ml/kg. min and transiently increased glycemia to 9.2 +/- 0.3 mmol/l at 60 min of infusion before it returned to the fasting level (5.6 +/- 0.3 mmol/l) at 3 h. When glucose and exendin-(9-39) were infused through the portal and femoral veins, respectively, glucose clearance increased to 70.0 +/- 4.6 ml/kg. min and glycemia decreased to 3.1 +/- 0.1 mmol/l, indicating that exendin-(9-39) has an effect only when infused into the portal vein. Finally, portal vein infusion of glucose in GLP-1 receptor(-/-) mice failed to increase the glucose clearance rate (26.7 +/- 2.9 ml/kg. min). Glycemia increased to 8.5 +/- 0.5 mmol/l at 60 min and remained elevated until the end of the glucose infusion (8.2 +/- 0.4 mmol/l). Together, our data show that the GLP-1 receptor is part of the hepatoportal glucose sensor and that basal fasting levels of GLP-1 sufficiently activate the receptor to confer maximum glucose competence to the sensor. These data demonstrate an important extrapancreatic effect of GLP-1 in the control of glucose homeostasis.
Resumo:
Ballet dancers have on average a low bone mineral content (BMC), with elevated fracture-risk, low body mass index (BMI) for age (body mass index, kg/m2), low energy intake, and delayed puberty. This study aims at a better understanding of the interactions of these factors, especially with regard to nutrition. During a competition for pre-professional dancers we examined 127 female participants (60 Asians, 67 Caucasians). They averaged 16.7 years of age, started dancing at 5.8 years, and danced 22 hours/week. Assessments were made for BMI, BMC (DXA), and bone mineral apparent density (BMAD) at the lumbar spine and femoral neck, pubertal stage (Tanner score), and nutritional status (EAT-40 questionnaire and a qualitative three-day dietary record). BMI for age was found to be normal in only 42.5% of the dancers, while 15.7% had a more or less severe degree of thinness (12.6% Grade2 and 3.1% Grade 3 thinness). Menarche was late (13.9 years, range 11 to 16.8 years). Food intake, evaluated by number of consumed food portions, was below the recommendations for a normally active population in all food groups except animal proteins, where the intake was more than twice the recommended amount. In this population, with low BMI and intense exercise, BMC was low and associated with nutritional factors; dairy products had a positive and non-dairy proteins a negative influence. A positive correlation between BMAD and years since menarche confirmed the importance of exposure to estrogens and the negative impact of delayed puberty. Because of this and the probable negative influence of a high intake of non-dairy proteins, such as meat, fish, and eggs, and the positive association with a high dairy intake, ballet schools should promote balanced diets and normal weight and should recognize and help dancers avoid eating disorders and delayed puberty caused by extensive dancing and inadequate nutrition.
Resumo:
BACKGROUND: Pulse wave velocity (PWV), an index of arterial wall stiffness, is modulated by blood pressure (BP). Whether heart rate (HR) is also a modulator of PWV is controversial. Recent research involving mainly patients with high aortic PWV have found either no change or a positive correlation between the two. Given that PWV is increasingly being measured in cardiovascular studies, the relationship between HR and PWV should be known in patients with preserved arterial wall elasticity. OBJECTIVE: The aim of this study was to evaluate the importance of HR as a determinant of the variability in PWV in patients with a low degree of atherosclerosis. DESIGN AND METHODS: Fourteen patients (five female, nine male; aged 68 +/- 8 years) were evaluated post pacemaker implantation due to sick sinus or carotid hypersensitivity syndromes. Carotid-femoral PWV was measured at rest and during atrial pacing at 80, 90 and 100 bpm (paced HR). Arterial femoral blood flow (AFBF) was measured by echodoppler. RESULTS: PWV increased from 6.2 +/- 1.5 m/s (mean +/- SD) during resting sinus rhythm (HR 62 +/- 8 bpm; mean +/- SD) to 6.8 +/- 1.0, 7.0 +/- 0.9, and 7.6 +/- 1.1 m/s at pacing rates of 80, 90 and 100 bpm, respectively (P < 0.0001). Systolic (SBP) and mean blood pressure (MBP) remained constant at all HR levels, whereas AFBF increased in a linear fashion. CONCLUSIONS: These results demonstrate that even in patients with a low degree of atherosclerosis, HR is a potential modulator of carotid-femoral PWV.
Resumo:
L’arteritis de cèl•lules gegantes (ACG) és una emergència mèdica i una causa comú de ceguesa en la nostra població major, la qual cosa converteix al oftalmòleg en el responsable del diagnòstic precoç i tractament oportú. Realitzem un estudi retrospectiu de 82 pacients amb sospita clínica de ACG, i es va observar la relació entre les troballes de la biòpsia d'artèria temporal (BAT) amb les troballes clíniques i de laboratori. Trobem que la BAT és poc sensible (50%) i altament específica (100%). 20 (40%) pacients van presentar compromís ocular. El símptoma clínic i el paràmetre de laboratori que es va relacionar amb BAT positiva van ser la claudicació mandibular (P=0,003) i la VSG (P= 0,006) respectivament.
Resumo:
Cannula design is of prime importance for venous drainage during cardiopulmonary bypass (CPB). To evaluate cannulas intended for CPB, an in vitro circuit was set up with silicone tubing between the test cannula encased in a movable preload reservoir and another static reservoir. The pressure-drop (DeltaP) value (P-drainage - P-preload) was measured using Millar pressure transducers. Flow rate (Q) was measured using an ultrasound flowmeter. Data display and data recording were controlled using a LabView application, custom made particularly for our experiments. Our results demonstrated that DeltaP, Q, and cannula resistance (DeltaP/Q) values were significantly decreased when the cannula diameter was increased for Smart and Medtronic cannulas. Smartcanula showed 36% and 43% less resistance compared to Medtronic venous and Medtronic femoral cannulas, respectively. The cannula shape (straight- or curved-tips) did not affect the DLP cannula resistance. Out of five cannulas tested, the Smartcanula outperforms the other commercially available cannulas. The mean (DeltaP/Q) values were 3.3 +/- 0.08, 4.07 +/- 0.08, 5.58 +/- 0.10, 5.74 +/- 0.15, and 6.45 +/- 0.15 for Smart, Medtronic, Edwards, Sarns, and Gambro cannulas, respectively (two-way ANOVA, p < 0.0001). In conclusion, the present assay allows discrimination between different forms of cannula with high or low lumen resistance.
Resumo:
La osteosíntesis mediante tornillo dinámico de cadera (DHS) está ampliamente aceptada como tratamiento de las fracturas intertrocantéreas del fémur proximal. El fracaso de este tipo de osteosíntesis suele deberse a la protrusión superior del tornillo (cut out) produciéndose una alteración de la función articular y dolor en el miembro afecto. La extracción de la cabeza y el fragmento de cuello femoral y la sustitución por una artroplastia de cadera resulta un procedimiento de rescate que en pacientes mayores proporciona una deambulación precoz y mejoría de sus molestias.
Resumo:
La fixació interna de les fractures pertrocantériques es una de les intervencions quirúrgiques més freqüents en Traumatologia. És precisament en les fractures més conminutes i inestables en les que el sistema de fixació i la seva correcta col•locació té major importància per evitar, en la major mesura possible, els desplaçaments secundaris de la fractura. El propòsit d’aquest treball és realitzar una revisió clínica quirúrgica d’aquestes fractures per demostrar el valor predictiu que tenen sobre l’èxit o fracàs de la osteosíntesis la col•locació del cargol cefàlic en el cap femoral i la distància al àpex.
Resumo:
Objectius: Valorar el significat dels defectes paradoxals (DP) segmentaris (captació en esforç més gran que en repòs) a la gated-SPECT (Single Photon Emission Computer Tomography) de perfusió miocàrdica amb compostos tecneciats en regions amb necrosi miocàrdica. Material i mètodes: Es van revisar 1764 SPECT de perfusió miocàrdica estrès-repòs consecutives de pacients amb infart (IM) previ i es van identificar 117 pacients (6,6%) en els quals els DPs corresponien a una regió amb necrosi miocàrdica. Es van valorar els criteris gammagràfics de viabilitat (intensitat del defecte, valor d'aquesta intensitat ponderat pel nombre de segments compromesos-VIP-, la motilitat i l'engrossiment miocàrdic sistòlic) en els segments d'aquestes regions i les característiques de l'artèria responsable en els 96 pacients en els quals s'havia practicat una coronariografia. Resultats: Es van analitzar 160 necrosis, 125 (75%) paradoxals (67 (54%) en regió AnteroSeptoApical i 58 (46%) en regió InferoLateral) i 35 (25%) no paradoxals (19 (54%) ASA i 16 ( 46%) IL). Els valors de severitat de la necrosi i del VIP van ser inferiors en l'estudi d'estrès respecte al repòs i la diferència d'aquests va ser sempre negativa, evidenciant un comportament gammagràfic paradoxal. Per contra, aquests valors van ser inferiors al repòs respecte a l'estrès en les necrosi no paradoxals posant de manifest un comportament gammagràfic de mínima o nul reversibilitat. Així mateix, es van trobar alteracions lleus en la motilitat i engrossiment de les necrosi paradoxals i moderats en les necrosi no paradoxals. Es van trobar 102 necrosis amb DP i coronariografia dels quals, 84 (88%) tenien permeabilitat a l'artèria responsable de la necrosi i 12 pacients (12%) tenien circulació colateral per compensar l'oclusió de l'artèria responsable. Conclusions: Tots els segments amb DP en regions amb necrosi complien criteris gammagràfics de viabilitat en les imatges d'estrès, considerant aquestes imatges millors per a l'avaluació d'aquest tipus de lesions. El vas responsable de la regió amb DP es trobava permeable o bé presentava circulació colateral evident en els casos en què la coronària es trobava closa.
Resumo:
Between 1985 and 1990 we treated 11 large segmental bone defects (average 6.7 cm) in ten patients with the Ilizarov technique. Open fractures, type III according to Gustilo, represented the largest group (8 of 11 cases). The average delay before the Ilizarov technique was initiated was 8.9 months. The external fixator was usually maintained for 1 year. Bone regeneration was obtained in every case. Consolidation was not fulfilled with this technique in three cases. The complications observed were one refracture, four leg-length discrepancies (average 1.5 cm), and five axial deformities exceeding 5 degrees. No pin-track infection was observed. In our limited series of four type IIIC open fractures treated by the Ilizarov technique, no patients required amputation. The Ilizarov technique is particularly useful in the treatment of large bone defects, without major complications, especially if there is an adequate initial debridement.
Resumo:
The treatment of hip osteoarthritis with total hip arthroplasty has continuously evolved since it was first introduced in the sixties. The problem of aseptic loosening of the cemented prostheses, mainly in young active patients, has stimulated two different types of research: on one side the improvement of cementing techniques and on the other side the development of cementless osteoinegrable implants. We discuss the problems of these cementless hip prostheses. Recently published anatomic and biomechanic studies have led to the development of personalized custom femoral stems for each patient. The conception technique and first clinical results are described.