859 resultados para Zygomatic fracture


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The basic morphology of the skeleton is determined genetically, but its final mass and architecture are modulated by adaptive mechanisms sensitive to mechanical factors. When subjected to loading, the ability of bones to resist fracture depends on their mass, material properties, geometry and tissue quality. The contribution of altered bone geometry to fracture risk is unappreciated by clinical assessment using absorptiometry because it fails to distinguish geometry and density. For example, for the same bone area and density, small increases in the diaphyseal radius effect a disproportionate influence on torsional strength of bone. Mechanical factors are clinically relevant because of their ability to influence growth, modeling and remodeling activities that can maximize, or maintain, the determinants of fracture resistance. Mechanical loads, greater than those habitually encountered by the skeleton, effect adaptations in cortical and cancellous bone, reduce the rate of bone turnover, and activate new bone formation on cortical and trabecular surfaces. In doing so, they increase bone strength by beneficial adaptations in the geometric dimensions and material properties of the tissue. There is no direct evidence to demonstrate anti-fracture efficacy for mechanical loading, but the geometric alterations engendered undoubtedly increase the structural properties of bone as an organ, increasing the resistance to fracture. Like all interventions, issues of safety also arise. Physical activities involving high strain rates, heavy lifting or impact loading may be detrimental to the joints, leading to osteoarthritis; may stimulate fatigue damage leading with some to stress fractures; or may interact pharmaceutical interventions to increase the rate of microdamage within cortical or trabecular bone.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Growing evidence supports low-intensity pulsed ultrasound (US) as an osteogenic mechanical stimulus. Its effects on isolated bone cells and on fractured bone are established. However, its effects on osteoporosis are not clear. This study examined US effects on ovariectomy (OVX) induced bone changes within the rodent hindlimb (distal femur and proximal tibia), and on normal bone in animals following sham-OVX. Animals were exposed to daily unilateral active-US and contralateral inactive-US for 12 weeks. Bone status was assessed using dual energy X-ray absorptiometry and histomorphometry. Ovariectomy resulted in significant bone changes. Low-intensity pulsed US did not influence these changes. These results suggest that the US dose introduced may not be a beneficial treatment for osteoporosis, and that intact bone may be less sensitive to US than fractured bone and isolated bone cells. This may relate to the biophysical mechanisms of action of US, US-bone interactions and tissue level processes taking place.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The effect of destabilisation and subcritical heat treatment on the impact toughness, hardness, and the amount and mechanical stability of retained austenite in a low carbon white cast iron have been investigated. The experimental results show that the impact energy constantly increases when the destabilisation temperature is raised from 950 degreesC to 1200 degreesC. Although the hardness decreases, the heat-treated hardness is still greater than the as-cast state. After destabilisation treatment at 1130 degreesC, tempering at 200 to 250 degreesC for 3 hours leads to the highest impact toughness, and secondary hardening was observed when tempering over 400 degreesC. The amount of retained austenite increased with the increase in the destabilisation temperature, and the treatment significantly improves the mechanical stability of the retained austenite compared with the as-cast state. Tempering below 400 degreesC does not affect the amount of retained austenite and its mechanical stability. But the amount of retained austenite is dramatically reduced when tempered above 400 degreesC. The relationship between the mechanical properties and the microstructure changes was discussed. (C) 2001 Kluwer Academic Publishers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Paget's disease of bone is a common condition characterized by bone pain, deformity, pathological fracture, and an increased incidence of osteosarcoma. Genetic factors play a role in the pathogenesis of Paget's disease but the molecular basis remains largely unknown. Susceptibility loci for Paget's disease of bone have been mapped to chromosome 6p21.3 (PDB1) and 18q121.1-q22 (PDB2) in different pedigrees, We have identified a large pedigree of over 250 individuals with 49 informative individuals affected with Paget's disease of bone; 31 of whom are available for genotypic analysis. The disease is inherited as an autosomal dominant trait in the pedigree with high penetrance by the sixth decade. Linkage analysis has been performed with markers at PDB1; these data show significant exclusion of linkage with log,, of the odds ratio (LOD) scores < -2 in this region. Linkage analysis of microsatellite markers from the PDB2 region has excluded linkage with this region, with a 30 cM exclusion region (LOD score < -2.0) centered on D18S42, These data confirm the genetic heterogeneity of Paget's disease of bone. Our hypothesis is that a novel susceptibility gene relevant to the pathogenesis of Paget's disease of bone lies elsewhere in the genome in the affected members of this pedigree and will be identified using a microsatellite genomewide scan followed by positional cloning.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper discusses the design and characterisation of a short, and hence portable impact load cell for in-situ quantification of ore breakage properties under impact loading conditions. Much literature has been published in the past two decades about impact load cells for ore breakage testing. It has been conclusively shown that such machines yield significant quantitative energy-fragmentation information about industrial ores. However, documented load cells are all laboratory systems that are not adapted for in-situ testing due to their dimensions and operating requirements. The authors report on a new portable impact load cell designed specifically for in-situ testing. The load cell is 1.5 m in height and weighs 30 kg. Its physical and operating characteristics are detailed in the paper. This includes physical dimensions, calibration and signal deconvolution. Emphasis is placed on the deconvolution issue, which is significant for such a short load cell. Finally, it is conclusively shown that the short load cell is quantitatively as accurate as its larger laboratory analogues. (C) 2062 Elsevier Science B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objectives of this study were to evaluate the outcomes of our patients admitted with hip fractures, and to benchmark these results with other hospitals, initially in Europe and subsequently in Australia. The Standardised Audit of Hip Fractures in Europe (SAHFE) questionnaires was used as the data gathering instrument. The participants were all patients admitted to Redcliffe Hospital with a fractured neck of femur prior to surgery. This paper reports the results of the first 70 consecutive patients admitted to Redcliffe Hospital with a fractured neck of femur from November 1st 2000. The main outcome measures were mobility, independence, residence prior to fracture; type of fracture and surgical repair; and time to surgery, survival rates and discharge destination. Results: 43 patients were admitted from home, but only 13 returned home directly from the orthopaedic ward. It is hoped that most of the 26 transferred to the rehabilitation ward will ultimately return home. 7 patients died, these were aged 82 to 102, and all had premorbid disease. Delays in surgery were apparent for 13 patients, mainly due to administrative problems. Conclusions: We support the recommendation in the Fifteenth Scottish Intercollegiate Guidelines Network Publication on the management of hip fractures, that all units treating this condition should enter an audit to evaluate their management. (author abstract)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The molecular orientation in a conventionally extruded PVC pipe, a uniaxially oriented PVC pipe and a biaxially oriented PVC pipe has been studied via Infrared dichroism. The degree of order or crystallinity has also been studied by Differential Scanning Calorimetry and also via Infrared Spectroscopy. The fundamental structural difference between the conventional and oriented pipes was that polymer chains were preferentially aligning in the hoop direction for oriented pipes whereas they were fairly isotropic in the conventional pipe with a slight preferential alignment in the axial direction. Analysis of the C-Cl stretching mode indicated that the uniaxially oriented pipe had much higher alignment of the C-Cl bond in the axial direction than the biaxial pipe, which correlates with higher fracture toughness for circumferential cracking in the biaxial pipe. Both DSC and Infrared spectroscopy detected little change in the crystallinity or order in the oriented pipes compared to the conventionally extruded pipes. (C) 2002 Kluwer Academic Publishers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper reviews the current knowledge and understanding of martensitic transformations in ceramics - the tetragonal to monoclinic transformation in zirconia in particular. This martensitic transformation is the key to transformation toughening in zirconia ceramics. A very considerable body of experimental data on the characteristics of this transformation is now available. In addition, theoretical predictions can be made using the phenomenological theory of martensitic transformations. As the paper will illustrate, the phenomenological theory is capable of explaining all the reported microstructural and crystallographic features of the transformation in zirconia and in some other ceramic systems. Hence the theory, supported by experiment, can be used with considerable confidence to provide the quantitative data that is essential for developing a credible, comprehensive understanding of the transformation toughening process. A critical feature in transformation toughening is the shape strain that accompanies the transformation. This shape strain, or nucleation strain, determines whether or not the stress-induced martensitic transformation can occur at the tip of a potentially dangerous crack. If transformation does take place, then it is the net transformation strain left behind in the transformed region that provides toughening by hindering crack growth. The fracture mechanics based models for transformation toughening, therefore, depend on having a full understanding of the characteristics of the martensitic transformation and, in particular, on being able to specify both these strains. A review of the development of the models for transformation toughening shows that their refinement and improvement over the last couple of decades has been largely a result of the inclusion of more of the characteristics of the stress-induced martensitic transformation. The paper advances an improved model for the stress-induced martensitic transformation and the strains resulting from the transformation. This model, which separates the nucleation strain from the subsequent net transformation strain, is shown to be superior to any of the constitutive models currently available. (C) 2002 Elsevier Science Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The effect of test temperature, which controls the stability of austenite, on the impact toughness of a low carbon Fe-Ni-Mn-C austenitic steel and 304 stainless steel, has been investigated. Under impact conditions, stress-induced martensitic transformation occurred, in a region near the fracture surface, at test temperatures below 80degreesC for the Fe-Ni-Mn-C steel and below -25degreesC for 304 stainless steel. The former shows significant transformation toughening and the highest impact toughness was obtained at 10degreesC, which corresponds to the maximum amount of martensite formed by stress-induced transformation above the Ms temperature. The stress-induced martensitic transformation contributes negatively to the impact toughness in the 304 stainless steel. Increasing the amount of stress-induced transformation to martensite, lowered the impact toughness. The experimental results can be well explained by the Antolovich theory through the analysis of metallography and fractography. The different effect of stress-induced transformation on the impact toughness in Fe-Ni-Mn-C steel and 304 stainless steel has been further understood by applying the crystallographic model for stress-induced martensitic transformation to these two steels. (C) 2002 Kluwer Academic Publishers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Indicators are valuable tools used to measure progress towards a desired health outcome. Increased awareness of the public health burden due to injury has lead to a concomitant interest in monitoring the impact of national initiatives that aim to reduce the size of the burden. Several injury indicators have now been proposed. This study examines the ability of each of the suggested indicators to reflect the nature and extent of the burden of non-fatal injury. A criterion validity, population-based, prospective cohort study was conducted in Brisbane, a sub-tropical Metropolitan City on the eastern seaboard of Australia, over a 12-month period between 1 January and 31 December 1998. Neither the presence of a long bone fracture nor the need for hospitalisation for 4 or more days were sensitive or specific indicators for 'serious' or major injury as defined by the 'Gold Standard' Injury Severity Score (ISS). Subsequent analysis, using other public health outcome measures demonstrated that the major component of the illness burden of injury was in fact due to 'minor' not serious injury. However, the suggested indicators demonstrated low sensitivity and specificity for these outcomes as well. The results of the study support the need to include at least all hospitalisations in any population-based measure of injury and not attempt to simplify the indicator to a more convenient measure aimed at identifying just those cases of,serious' injury.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The particle-based Lattice Solid Model (LSM) was developed to provide a basis to study the physics of rocks and the nonlinear dynamics of earthquakes (MORA and PLACE, 1994; PLACE and MORA, 1999). A new modular and flexible LSM approach has been developed that allows different microphysics to be easily included in or removed from the model. The approach provides a virtual laboratory where numerical experiments can easily be set up and all measurable quantities visualised. The proposed approach provides a means to simulate complex phenomena such as fracturing or localisation processes, and enables the effect of different micro-physics on macroscopic behaviour to be studied. The initial 2-D model is extended to allow three-dimensional simulations to be performed and particles of different sizes to be specified. Numerical bi-axial compression experiments under different confining pressure are used to calibrate the model. By tuning the different microscopic parameters (such as coefficient of friction, microscopic strength and distribution of grain sizes), the macroscopic strength of the material and can be adjusted to be in agreement with laboratory experiments, and the orientation of fractures is consistent with the theoretical value predicted based on Mohr-Coulomb diagram. Simulations indicate that 3-D numerical models have different macroscopic properties than in 2-D and, hence, the model must be recalibrated for 3-D simulations. These numerical experiments illustrate that the new approach is capable of simulating typical rock fracture behaviour. The new model provides a basis to investigate nucleation, rupture and slip pulse propagation in complex fault zones without the previous model limitations of a regular low-level surface geometry and being restricted to two-dimensions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Venous thromboembolism is a frequent, life-threatening, postoperative complication of hip-fracture and total-knee-replacement surgery. Fondaparinux is a synthetic polysaccharide that selectively binds to antithrombin, the primary endogenous regulator of blood coagulation. Low molecular weight heparins, such as enoxaparin, are less specific inhibitors of coagulation. In patients undergoing hip-fracture surgery, fondaparinux is more effective than once-daily enoxaparin as prophylaxis for venous thromboembolism. Fondaparinux (25 mg/day s.c.) was also more effective than enoxaparin (30 mg s.c. b.i.d.) as prophylaxis for venous thromboembolism in elective knee surgery. These differences may be explained by the fact that there is less prophylaxis cover with enoxaparin, as it has a much shorter duration of action than fondaparinux. Thus, with the present dosing regimens, fondaparinux is probably preferable to enoxaparin for the prevention of venous thromboembolism.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Detection of a circumferential crack in a hollow section beam is investigated using coupled response measurements. The crack section is represented by a local flexibility matrix connecting two undamaged beam segments. This matrix defines the relationship between the displacements and forces across the crack section and is derived by applying fundamental fracture mechanics theory. The suitability of the mode coupling methodology is first demonstrated analytically. Laboratory test results are then presented for circular hollow section beams with artificially generated cracks of varying severity. It is shown that this method has the potential as a damage detection tool for mechanical structures. (C) 2002 Elsevier Science Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Three pathological fractures occurred secondary to osteolytic lesions of multiple myeloma. Two long bone fractures were each stabilised using interlocking nail fixation augmented with polymethyl meth acral ate bone cement. One vertebral fracture was stabilised using Steinmann pins and PMMA. Successful stabilisation, rapid return to function and improvement in quality of life occurred in all fractures. The patient survived approximately eight months on concurrent chemotherapy.