946 resultados para Waste water drainage
Resumo:
Acknowledgements We are grateful to the United Kingdom Economic and Social Research Council Nexus Network for funding this work.
Resumo:
Acknowledgements We are grateful to the United Kingdom Economic and Social Research Council Nexus Network for funding this work.
Resumo:
The hydrothermal liquefaction(HTL) of algal biomass is a promising route to viable second generation biofuels. In this investigation HTL was assessed for the valorisation of algae used in the remediation of acid mine drainage (AMD). Initially the HTL process was evaluated using Arthrospira platensis (Spirulina) with additional metal sulphates to simulate metal remediation. Optimised conditions were then used to process a natural algal community (predominantly Chlamydomonas sp.) cultivated under two scenarios: high uptake and low uptake of metals from AMD. High metal concentrations appear to catalyse the conversion to bio-oil, and do not significantly affect the heteroatom content or higher heating value of the bio-oil produced. The associated metals were found to partition almost exclusively into the solid residue, favourable for potential metal recovery. High metal loadings also caused partitioning of phosphates from the aqueous phase to the solid phase, potentially compromising attempts to recycle process water as a growth supplement. HTL was therefore found to be a suitable method of processing algae used in AMD remediation, producing a crude oil suitable for upgrading into hydrocarbon fuels, an aqueous and gas stream suitable for supplementing the algal growth and the partitioning of most contaminant metals to the solid residue where they would be readily amenable for recovery and/or disposal.
Resumo:
The hydrothermal liquefaction(HTL) of algal biomass is a promising route to viable second generation biofuels. In this investigation HTL was assessed for the valorisation of algae used in the remediation of acid mine drainage (AMD). Initially the HTL process was evaluated using Arthrospira platensis (Spirulina) with additional metal sulphates to simulate metal remediation. Optimised conditions were then used to process a natural algal community (predominantly Chlamydomonas sp.) cultivated under two scenarios: high uptake and low uptake of metals from AMD. High metal concentrations appear to catalyse the conversion to bio-oil, and do not significantly affect the heteroatom content or higher heating value of the bio-oil produced. The associated metals were found to partition almost exclusively into the solid residue, favourable for potential metal recovery. High metal loadings also caused partitioning of phosphates from the aqueous phase to the solid phase, potentially compromising attempts to recycle process water as a growth supplement. HTL was therefore found to be a suitable method of processing algae used in AMD remediation, producing a crude oil suitable for upgrading into hydrocarbon fuels, an aqueous and gas stream suitable for supplementing the algal growth and the partitioning of most contaminant metals to the solid residue where they would be readily amenable for recovery and/or disposal.
Resumo:
Recent proxy measurements reveal that subglacial lakes beneath modern ice sheets periodically store and release large volumes of water, providing an important but poorly understood influence on contemporary ice dynamics and mass balance. This is because direct observations of how lake drainage initiates and proceeds are lacking. Here we present physical evidence of the mechanism and geometry of lake drainage from the discovery of relict subglacial lakes formed during the last glaciation in Canada. These palaeo-subglacial lakes comprised shallow (<10 m) lenses of water perched behind ridges orientated transverse to ice flow. We show that lakes periodically drained through channels incised into bed substrate (canals). Canals sometimes trend into eskers that represent the depositional imprint of the last high-magnitude lake outburst. The subglacial lakes and channels are preserved on top of glacial lineations, indicating long-term re-organization of the subglacial drainage system and coupling to ice flow.
Resumo:
The internal combustion (IC) engines exploits only about 30% of the chemical energy ejected through combustion, whereas the remaining part is rejected by means of cooling system and exhausted gas. Nowadays, a major global concern is finding sustainable solutions for better fuel economy which in turn results in a decrease of carbon dioxide (CO2) emissions. The Waste Heat Recovery (WHR) is one of the most promising techniques to increase the overall efficiency of a vehicle system, allowing the recovery of the heat rejected by the exhaust and cooling systems. In this context, Organic Rankine Cycles (ORCs) are widely recognized as a potential technology to exploit the heat rejected by engines to produce electricity. The aim of the present paper is to investigate a WHR system, designed to collect both coolant and exhausted gas heats, coupled with an ORC cycle for vehicle applications. In particular, a coolant heat exchanger (CLT) allows the heat exchange between the water coolant and the ORC working fluid, whereas the exhausted gas heat is recovered by using a secondary circuit with diathermic oil. By using an in-house numerical model, a wide range of working conditions and ORC design parameters are investigated. In particular, the analyses are focused on the regenerator location inside the ORC circuits. Five organic fluids, working in both subcritical and supercritical conditions, have been selected in order to detect the most suitable configuration in terms of energy and exergy efficiencies.
Resumo:
The application of membrane separation processes (PSM) for treatment of radioactive waste requires the selection of a suitable membrane for the treatment of waste, as the membrane will be directly exposed to the radioactive liquid waste, and also exposed to ionizing radiation. The nanofiltration membrane is most suitable for treatment of radioactive waste, since it has high rejection of multivalent ions. Usually the membranes are made of polymers and depending on the composition of the waste, type and dose of radiation absorbed may be changes in the structure of the membrane, resulting in loss of its transport properties. We tested two commercial nanofiltration membranes: NF and SW Dow/Filmtec. The waste liquid used was obtained in the process of conversion of uranium hexafluoride gas to solid uranium dioxide, known as "carbonated water". The membranes were characterized as their transport properties (hydraulic permeability, permeate flux and salt rejection) before and after their immersion in the waste for 24 hours. The surface of the membranes was also evaluated by SEM and FTIR. It was observed that in both the porosity of the membrane selective layer was altered, but not the membrane surface charge, which is responsible for the selectivity of the membrane. The NF membranes and SW showed uranium ion rejection of 64% and 55% respectively.
Resumo:
Thesis (Master's)--University of Washington, 2016-06
Resumo:
Compared to the use of traditional fossil fuels (coal, oil, natural gas), combustion of biomass and waste fuels has several environmental and economic advantages for heat and power generation. However, biomass and waste fuels might contain halogens (Cl, Br, F), alkali metals (Na, K) and heavy metals (Zn, Pb), which may cause harmful emissions and corrosion problems. Hightemperature corrosion occurs typically on furnace waterwalls and superheaters. The corrosion of the boiler tube materials limits the increase of thermal efficiency of steam boilers and leads to costly shutdowns and repairs. In recent years, some concerns have been raised about halogen (Cl, Br, and F)-related hightemperature corrosion in biomass- and waste-fired boilers. Chlorine-related high-temperature corrosion has been studied extensively. The presence of alkali chlorides in the deposits is believed to play a major role in the corrosion observed in biomass and waste fired boilers. However, there is much less information found in literature on the corrosion effect of bromine and fluorine. According to the literature, bromine is only assumed to play a role similar to chlorine; the role of fluorine is even less understood. In this work, a series of bubbling fluidized bed (BFB) bench-scale tests were carried out to characterize the formation and sulfation behaviors of KCl and KBr in BFB combustion conditions. Furthermore, a series of laboratory tests were carried out to investigate the hightemperature corrosion behaviors of three different superheater steels (10CrMo9-10, AISI 347 and Sanicro 28) exposed to potassium halides in ambient air and wet air (containing 30% H2O). The influence of H2O and O2 on the high-temperature corrosion of steels both with and without a salt (KCl) in three gas atmospheres (2% H2O-30% O2-N2, 2% H2O-2% O2-N2 and 30% H2O-2% O2-N2) was also studied. From the bench-scale BFB combustion tests, it was found that HBr has a clearly higher affinity for the available K forming KBr than HCl forming KCl. The tests also indicated that KCl has a higher tendency for sulfation than KBr. From the laboratory corrosion tests in ambient air (also called “dry air” in Paper III and Paper IV), it was found that at relatively low temperatures (≤ 550 °C) the corrosivity of KBr and KF are similar to KCl. At 600 °C, KF showed much stronger corrosivity than KBr and KCl, especially for 10CrMo9-10 and AISI 347. When exposed to KBr or KF, 10CrMo9-10 was durable at least up to 450 °C, while AISI 347 and Sanicro 28 were durable at least up to 550 °C. From the laboratory corrosion tests in wet air (30% H2O), no obvious effect of water vapor was detected at 450 °C. At 550 °C, the influence of water vapor became significant in some cases, but the trend was not consistent. At 550 °C, after exposure with KBr, 10CrMo9-10 suffered from extreme corrosion; after exposure with KF and KCl, the corrosion was less severe, but still high. At 550 °C, local deep pitting corrosion occurred on AISI 347 and Sanicro 28 after exposure with KF. Some formation of K2CrO4 was observed in the oxide layer. At 550 °C, AISI 347 and Sanicro 28 suffered from low corrosion (oxide layer thickness of < 10 μm) after exposure with KBr and KCl. No formation of K2CrO4 was observed. Internal oxidation occurred in the cases of AISI 347 with KBr and KCl. From the laboratory corrosion tests in three different gas atmospheres (2% H2O-30% O2-N2, 2% H2O-2% O2-N2 and 30% H2O-2% O2-N2), it was found that in tests with no salt, no corrosion occurred on AISI 347 and Sanicro 28 up to 600 °C in both the “O2-rich” (2% H2O-30% O2-N2) and “H2O-rich” (30% H2O-2% O2-N2) gas atmospheres; only 10CrMo9-10 showed increased corrosion with increasing temperature. For 10CrMo9-10 in the “O2-rich” atmosphere, the presence of KCl significantly increased the corrosion compared to the “no salt” cases. For 10CrMo9-10 in the “H2O-rich” atmosphere, the presence or absence of KCl did not show any big influence on corrosion. The formation of K2CrO4 was observed only in the case with the “O2-rich” atmosphere. Considering both the results from the BFB tests and the laboratory corrosion tests, if fuels containing Br were to be combusted, the corrosion damage of superheaters would be expected to be higher than if the fuels contain only Cl. Information generated from these studies can be used to help the boiler manufacturers in selecting materials for the most demanding combustion systems.
Resumo:
The overarching goal of this research is to establish a successful forum for a transition from the existing paradigm of managing wastewater infrastructure to a more sustainable paradigm that achieves a more efficient utilisation of wastewater assets. A transitioning approach to support a more efficient utilisation of surface water and wastewater assets and infrastructure is proposed and developed. The determined transitioning approach possesses key stages namely developing the arena, developing the agenda, case study, and monitoring. The case study stage investigates a drainage utility identifying their improvement drivers, the removal of surface water through detailed drainage modelling and the financial examination of the costs incurred under the various scenarios conducted. Understanding the implications of removing/attenuating surface water from the network is improved through obtaining data by detailed drainage modelling. Infoworks software is used to investigate and assess the current and future operational scenarios of a wastewater system operating over one calendar year. Modelling scenarios were conducted removing surface water from selected areas focusing on the volumes requiring pumping and durations of pumping station(s) operation prior to treatment during storm conditions. The financial implication of removing surface water in combined sewer systems is examined in three main components. Firstly the costs of electricity incurred at the single sewage pumping station (SPS) investigated during the various scenarios modelled require to be addressed. Secondly the costs to retrofit sustainable urban drainage system (SUDS) solutions needs to be identified. Thirdly the implications of removing surface water for the drainage utility at the national level and the potential saving for householder’s committing to a surface water disconnection rebate scheme. When addressed at the macro level i.e., with over 2,100 pumping stations, some operating in sequence and contained within one drainage utility annually treating 315,360 megalitres the significance of the same multiple quantifiable and intangible benefits becomes amplified. The research aims, objectives and findings are presented to the identified and convened stakeholders. The transitioning approach developed encourages positive discourse between stakeholders. The level of success of the transitioning approach determined is then tested using a quantitative methodology through the completion of questionnaires. From the questionnaires completed the respondents unanimously agreed that surface water flows should be removed as well as reduced from the combined sewer system. The respondents agreed that the removal of surface water from a typical combined sewer system is justified by applying a transitioning approach focusing on the energy consumption required to pump increased volumes during storm events. This response is significant based upon the economic evidence and is contrary to the respondents previous position that finance was their most influencing factor. When provided with other potentially available benefits the respondents were even more supportive of the justification to remove surface water from the combined sewer system. The combined findings of the work presented in this thesis provide further justification that the transitioning approach applied to the removal of surface water from a typical combined sewer system, as determined in this research has been successful.
Resumo:
The effects of different solvents on the recovery of (i) extractable solids (ES), (ii) total phenolic compounds (TPC), (iii) total flavonoid content (TFC), (iv) vitamin C, and (v) antioxidant activity from lemon pomace waste were investigated. The results revealed that solvents significantly affected the recovery of ES, TPC, TFC, and antioxidant properties. Absolute methanol and 50% acetone resulted in the highest extraction yields of TPC, whereas absolute methanol resulted in the highest extraction of TFC, and water had the highest recovery of vitamin C. 50% ethanol, and 50% acetone had higher extraction yields for TPC, and TFC, as well as higher antioxidant activity compared with their absolute solvents and water. TPC and TFC were shown to be the major components contributing to the antioxidant activity of lemon pomace.
Resumo:
Le béton conventionnel (BC) a de nombreux problèmes tels que la corrosion de l’acier d'armature et les faibles résistances des constructions en béton. Par conséquent, la plupart des structures fabriquées avec du BC exigent une maintenance fréquent. Le béton fibré à ultra-hautes performances (BFUP) peut être conçu pour éliminer certaines des faiblesses caractéristiques du BC. Le BFUP est défini à travers le monde comme un béton ayant des propriétés mécaniques, de ductilité et de durabilité supérieures. Le BFUP classique comprend entre 800 kg/m³ et 1000 kg/m³ de ciment, de 25 à 35% massique (%m) de fumée de silice (FS), de 0 à 40%m de poudre de quartz (PQ) et 110-140%m de sable de quartz (SQ) (les pourcentages massiques sont basés sur la masse totale en ciment des mélanges). Le BFUP contient des fibres d'acier pour améliorer sa ductilité et sa résistance aux efforts de traction. Les quantités importantes de ciment utilisées pour produire un BFUP affectent non seulement les coûts de production et la consommation de ressources naturelles comme le calcaire, l'argile, le charbon et l'énergie électrique, mais affectent également négativement les dommages sur l'environnement en raison de la production substantielle de gaz à effet de serre dont le gas carbonique (CO[indice inférieur 2]). Par ailleurs, la distribution granulométrique du ciment présente des vides microscopiques qui peuvent être remplis avec des matières plus fines telles que la FS. Par contre, une grande quantité de FS est nécessaire pour combler ces vides uniquement avec de la FS (25 à 30%m du ciment) ce qui engendre des coûts élevés puisqu’il s’agit d’une ressource limitée. Aussi, la FS diminue de manière significative l’ouvrabilité des BFUP en raison de sa surface spécifique Blaine élevée. L’utilisation du PQ et du SQ est également coûteuse et consomme des ressources naturelles importantes. D’ailleurs, les PQ et SQ sont considérés comme des obstacles pour l’utilisation des BFUP à grande échelle dans le marché du béton, car ils ne parviennent pas à satisfaire les exigences environnementales. D’ailleurs, un rapport d'Environnement Canada stipule que le quartz provoque des dommages environnementaux immédiats et à long terme en raison de son effet biologique. Le BFUP est généralement vendu sur le marché comme un produit préemballé, ce qui limite les modifications de conception par l'utilisateur. Il est normalement transporté sur de longues distances, contrairement aux composantes des BC. Ceci contribue également à la génération de gaz à effet de serre et conduit à un coût plus élevé du produit final. Par conséquent, il existe le besoin de développer d’autres matériaux disponibles localement ayant des fonctions similaires pour remplacer partiellement ou totalement la fumée de silice, le sable de quartz ou la poudre de quartz, et donc de réduire la teneur en ciment dans BFUP, tout en ayant des propriétés comparables ou meilleures. De grandes quantités de déchets verre ne peuvent pas être recyclées en raison de leur fragilité, de leur couleur, ou des coûts élevés de recyclage. La plupart des déchets de verre vont dans les sites d'enfouissement, ce qui est indésirable puisqu’il s’agit d’un matériau non biodégradable et donc moins respectueux de l'environnement. Au cours des dernières années, des études ont été réalisées afin d’utiliser des déchets de verre comme ajout cimentaire alternatif (ACA) ou comme granulats ultrafins dans le béton, en fonction de la distribution granulométrique et de la composition chimique de ceux-ci. Cette thèse présente un nouveau type de béton écologique à base de déchets de verre à ultra-hautes performances (BEVUP) développé à l'Université de Sherbrooke. Les bétons ont été conçus à l’aide de déchets verre de particules de tailles variées et de l’optimisation granulaire de la des matrices granulaires et cimentaires. Les BEVUP peuvent être conçus avec une quantité réduite de ciment (400 à 800 kg/m³), de FS (50 à 220 kg/m³), de PQ (0 à 400 kg/m³), et de SQ (0-1200 kg/m³), tout en intégrant divers produits de déchets de verre: du sable de verre (SV) (0-1200 kg/m³) ayant un diamètre moyen (d[indice inférieur 50]) de 275 µm, une grande quantité de poudre de verre (PV) (200-700 kg/m³) ayant un d50 de 11 µm, une teneur modérée de poudre de verre fine (PVF) (50-200 kg/m³) avec d[indice inférieur] 50 de 3,8 µm. Le BEVUP contient également des fibres d'acier (pour augmenter la résistance à la traction et améliorer la ductilité), du superplastifiants (10-60 kg/m³) ainsi qu’un rapport eau-liant (E/L) aussi bas que celui de BFUP. Le remplacement du ciment et des particules de FS avec des particules de verre non-absorbantes et lisse améliore la rhéologie des BEVUP. De plus, l’utilisation de la PVF en remplacement de la FS réduit la surface spécifique totale nette d’un mélange de FS et de PVF. Puisque la surface spécifique nette des particules diminue, la quantité d’eau nécessaire pour lubrifier les surfaces des particules est moindre, ce qui permet d’obtenir un affaissement supérieur pour un même E/L. Aussi, l'utilisation de déchets de verre dans le béton abaisse la chaleur cumulative d'hydratation, ce qui contribue à minimiser le retrait de fissuration potentiel. En fonction de la composition des BEVUP et de la température de cure, ce type de béton peut atteindre des résistances à la compression allant de 130 à 230 MPa, des résistances à la flexion supérieures à 20 MPa, des résistances à la traction supérieure à 10 MPa et un module d'élasticité supérieur à 40 GPa. Les performances mécaniques de BEVUP sont améliorées grâce à la réactivité du verre amorphe, à l'optimisation granulométrique et la densification des mélanges. Les produits de déchets de verre dans les BEVUP ont un comportement pouzzolanique et réagissent avec la portlandite générée par l'hydratation du ciment. Cependant, ceci n’est pas le cas avec le sable de quartz ni la poudre de quartz dans le BFUP classique, qui réagissent à la température élevée de 400 °C. L'addition des déchets de verre améliore la densification de l'interface entre les particules. Les particules de déchets de verre ont une grande rigidité, ce qui augmente le module d'élasticité du béton. Le BEVUP a également une très bonne durabilité. Sa porosité capillaire est très faible, et le matériau est extrêmement résistant à la pénétration d’ions chlorure (≈ 8 coulombs). Sa résistance à l'abrasion (indice de pertes volumiques) est inférieure à 1,3. Le BEVUP ne subit pratiquement aucune détérioration aux cycles de gel-dégel, même après 1000 cycles. Après une évaluation des BEVUP en laboratoire, une mise à l'échelle a été réalisée avec un malaxeur de béton industriel et une validation en chantier avec de la construction de deux passerelles. Les propriétés mécaniques supérieures des BEVUP a permis de concevoir les passerelles avec des sections réduites d’environ de 60% par rapport aux sections faites de BC. Le BEVUP offre plusieurs avantages économiques et environnementaux. Il réduit le coût de production et l’empreinte carbone des structures construites de béton fibré à ultra-hautes performances (BFUP) classique, en utilisant des matériaux disponibles localement. Il réduit les émissions de CO[indice inférieur 2] associées à la production de clinkers de ciment (50% de remplacement du ciment) et utilise efficacement les ressources naturelles. De plus, la production de BEVUP permet de réduire les quantités de déchets de verre stockés ou mis en décharge qui causent des problèmes environnementaux et pourrait permettre de sauver des millions de dollars qui pourraient être dépensés dans le traitement de ces déchets. Enfin, il offre une solution alternative aux entreprises de construction dans la production de BFUP à moindre coût.
Resumo:
Macadamias, adapted to the fringes of subtropical rainforests of coastal, eastern Australia, are resilient to mild water stress. Even after prolonged drought, it is difficult to detect stress in commercial trees. Despite this, macadamia orchards in newer irrigated regions produce more consistent crops than those from traditional, rain-fed regions. Crop fluctuations in the latter tend to follow rainfall patterns. The benefit of irrigation in lower rainfall areas is undisputed, but there are many unanswered questions about the most efficient use of irrigation water. Water is used more efficiently when it is less readily available, causing partial stomatal closure that restricts transpiration more than it restricts photosynthesis. Limited research suggests that macadamias can withstand mild stress. In fact, water use efficiency can be increased by strategic deficit irrigation. However, macadamias are susceptible to stress during oil accumulation. There may be benefits of applying more water at critical times, less at others, and this may vary with cultivar. Currently, it is common for macadamia growers to apply about 20-40 L tree-1 day-1 of water to their orchards in winter and 70-90 L tree-1 day-1 in summer. Research reported water use at 20-30 L tree-1 day-1 during winter and 40-50 L tree-1 day-1 in summer using the Granier sap flow technique. The discrepancy between actual water use and farmer practice may be due to water loss via evaporation from the ground, deep drainage and/or greater transpiration due to luxury water consumption. More irrigation research is needed to develop efficient water use and to set practical limits for deficit irrigation management.
Resumo:
This design thesis is an inquiry of the highly industrialized urban landscape of the Lake Calumet Complex on the South Side of the City of Chicago. It examines geologic and anthropogenic strata within this region as waste used for staging various social, industrial, and ecological systems. Today, these social, industrial, and ecological systems are not responsive to each other and certainly do not possess resilient attributes that would allow them to interact within the landscape in perpetuity. The resulting design strategy seeks to re-think the treatment of waste in the landscape into a new framework for future park design. This park will serve as grounds to interweave these complex systems in order to rehabilitate ecosystem functions and improve water quality. Additionally the park hybridizes many social and ecological functions to improve community recreational opportunities and gain public acceptance and appeal.
Resumo:
Water regimes in the Brazilian Cerrados are sensitive to climatological disturbances and human intervention. The risk that critical water-table levels are exceeded over long periods of time can be estimated by applying stochastic methods in modeling the dynamic relationship between water levels and driving forces such as precipitation and evapotranspiration. In this study, a transfer function-noise model, the so called PIRFICT-model, is applied to estimate the dynamic relationship between water-table depth and precipitation surplus/deficit in a watershed with a groundwater monitoring scheme in the Brazilian Cerrados. Critical limits were defined for a period in the Cerrados agricultural calendar, the end of the rainy season, when extremely shallow levels (< 0.5-m depth) can pose a risk to plant health and machinery before harvesting. By simulating time-series models, the risk of exceeding critical thresholds during a continuous period of time (e.g. 10 days) is described by probability levels. These simulated probabilities were interpolated spatially using universal kriging, incorporating information related to the drainage basin from a digital elevation model. The resulting map reduced model uncertainty. Three areas were defined as presenting potential risk at the end of the rainy season. These areas deserve attention with respect to water-management and land-use planning.