972 resultados para VACUUM MISALIGNMENT


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The field emissions from three different types of carbon films are studied using a Kiethly voltage-current source-measure unit under computer control. The three types of carbon films are : 1) a-C:H:N deposited using an inductively coupled rf PECVD process, where the N content in the films can be as high as 30 at %; 2) cathodic arc deposited tetrahedral amorphous carbon with embedded regions of carbon nanotube and anion structures and 3) unoriented carbon nanotube films on a porous substrate. The films are formed by filtering a solution of nanotubes dispersed in alcohol through the pores and drying.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Single grain REBa2C3uO7 ((RE)BCO, where RE is a rare earth element or yttrium) bulk superconducting materials have significant potential for a variety of engineering applications due to their ability to trap high magnetic fields. However, it is well known that the presence of grain boundaries coupled with a high angle of misorientation (typically 5�) significantly reduces the critical current density, J c , in all forms of high temperature superconducting materials. It is of considerable fundamental and technological interest, therefore, to investigate the grain boundary properties of bulk, film and tape (RE)BCO. We report a successful multi-seeding technique for the fabrication of fully aligned, artificial (0��misalignment) grain boundaries within large grain YBCO bulk superconductors using bridge-shaped seeds. The microstructure and critical current densities of the grain boundaries produced by this technique have been studied in detail.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The compressive behaviour of finite unidirectional composites with a region of misaligned reinforcement is investigated via finite element analyses. Models with and without fibre bending stiffness are compared, confirming that compressive strength is accurately predicted without modelling fibre bending stiffness for real composite components which typically have waviness defects of several millimetres wavelength. Various defect parameters are investigated. Results confirm the well-known sensitivity of compressive strength to misalignment angle, and also show that compressive strength falls rapidly with the proportion of laminate width covered by the wavy region. A simple empirical equation is proposed to model the effect of a single patch of waviness in finite specimens. Other parameters such as length and position of the wavy region are found to have a smaller effect on compressive strength. The modelling approach is finally adapted to model distributed waviness and thus determine the compressive strength of composites with realistic waviness defects. © 2011 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report on the growth of single-walled carbon nanotubes from a monometallic Co catalyst on an oxidized Si wafer support by the most simple growth recipe (vacuum annealing, growth by undiluted C 2H 2). Nevertheless, multiwavelength Raman spectroscopy and transmission electron spectroscopy show a remarkable selectivity for chiral indices and thus, e.g., high abundance with a single chirality representing 58% of all semiconducting tubes. In situ x-ray photoelectron spectroscopy monitors the catalyst chemistry during carbon nanotube growth and shows interfacial Co-Si interactions that may help to stabilize the nanoparticle/nanotube diameter. We outline a two-mechanism model explaining the selective growth. © 2012 American Physical Society.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Half of the world’s urban population will live in informal settlements or “slums” by 2030. Affordable urban sanitation presents a unique set of challenges as the lack of space and resources to construct new latrines makes the de-sludging of existing pits necessary and is something that is currently done manually with significant associated health risks. Therefore various mechanised technologies have been developed to facilitate pit emptying, with the majority using a vacuum system to remove material from the top of the pit. However, this results in the gradual accumulation of unpumpable sludge in the pit, which eventually fills the latrine and forces it to be abandoned. This study has developed a method for fluidising unpumpable pit latrine sludge, based on laboratory experiments using a harmless synthetic sludge. Such a sludge consisting of clay and compost was developed to replicate the physical characteristics of pit latrine sludges characterised in Botswana during the 1980s. Undrained shear strength and density are identified as the critical parameters in controlling pumpability and a method of sludge characterisation based on these parameters is reported. In a series of fluidisation tests using a one fifth scale pit emptying device the reduction in sludge shear strength was found to be caused by i) dilution, which increases water content, and ii) remoulding, which involves mechanical agitation to break down the structure of the material. The tests demonstrated that even the strongest of sludges could be rendered “pumpable” by sufficient dilution. Additionally, air injection alone produced a three-fold decrease in strength of consolidated samples as a result of remoulding at constant water content. The implications for sludge treatment and disposal are discussed, and the classification of sludges according to the equipment required to remove them from the latrine is proposed. Possible field tests to estimate sludge density and shear strength are suggested. The feasibility of using low cost vacuum cleaners to replace expensive vane pumps is demonstrated. This offers great potential for the development of affordable pit emptying technologies that can remove significantly stronger sludges than current devices through fluidising the wastes at the bottom of the pit before emptying

Relevância:

10.00% 10.00%

Publicador:

Resumo:

High-frequency ultrasound is needed for medical imaging with high spatial resolution. A key issue in the development of ultrasound imaging arrays to operate at high frequencies (≥30 MHz) is the need for photolithographic patterning of array electrodes. To achieve this directly on 1-3 piezocomposite, the material requires not only planar, parallel, and smooth surfaces, but also an epoxy composite filler that is resistant to chemicals, heat, and vacuum. This paper reports, first, on the surface finishing of 1-3 piezocomposite materials by lapping and polishing. Excellent surface flatness has been obtained, with an average surface roughness of materials as low as 3 nm and step heights between ceramic/polymer of ∼80 nm. Subsequently, high-frequency array elements were patterned directly on top of these surfaces using a photolithography process. A 30-MHz linear array electrode pattern with 50-μm element pitch has been patterned on the lapped and polished surface of a high-frequency 1-3 piezocomposite. Excellent electrode edge definition and electrical contact to the composite were obtained. The composite has been lapped to a final thickness of ∼55 μm. Good adhesion of electrodes on the piezocomposite has been achieved and electrical impedance measurements have demonstrated their basic functionality. The array was then packaged, and acoustic pulse-echo measurements were performed. These results demonstrate that direct patterning of electrodes by photolithography on 1-3 piezocomposite is feasible for fabrication of high-frequency ultrasound arrays. Furthermore, this method is more conducive to mass production than other reported array fabrication techniques.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Change propagates, potentially affecting many aspects of a design and requiring much rework to implement. This article introduces a cross-domain approach to decompose a design and identify possible change propagation linkages, complemented by an interactive tool that generates dynamic checklists to assess change impact. The approach considers the information domains of requirements, functions, components, and the detail design process. Laboratory experiments using a vacuum cleaner suggest that cross-domain modelling helps analyse a design to create and capture the information required for change prediction. Further experiments using an electronic product show that this information, coupled with the interactive tool, helps to quickly and consistently assess the impact of a proposed change. © 2012 Springer-Verlag London Limited.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper will cover several applications of a particular type of field emitter- the carbon nanotube (CNT). The growth of CNTs and their optimization for use in various applications including, parallel e-beam lithography, field emission displays and microwave sources, is considered. © 2012 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We are investigating the use of flywheels for energy storage. Flywheel devices need to be of high efficiency and an important source of losses is the bearings. In addition, the requirement is for the devices to have long lifetimes with minimal or no maintenance. Conventional rolling element bearings can and have been used, but a non-contact bearing, such as a superconducting magnetic bearing, is expected to have a longer lifetime and lower losses. At Cambridge we have constructed a flywheel system. Designed to run in vacuum this incorporates a 40kg flywheel supported on superconducting magnetic bearings. The production device will be a 5kW device storing 5 kWh of retrievable energy at 50,000 rpm. The Cambridge system is being developed in parallel with a similar device supported on a conventional bearing. This will allow direct performance comparisons. Although superconducting bearings are increasingly well understood, of major importance are the cryogenics and special attention is being paid to methods of packaging and insulating the superconductors to cut down radiation losses. The work reported here is part of a three-year program of work supported by the EPSRC. © 1999 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Carbon coatings of thickness down to 2 nanometers are needed to increase the storage density in magnetic hard disks and reach the 100 Gbit/in2 target. Methods to measure the properties of these ultrathin hard films still have to be developed. We show that combining Surface Brillouin Scattering (SBS) andX-ray reflectivity measurements the elastic constants of such films are accessible. Tetrahedral amorphous carbofilms of thickness down to about 2 nm were deposited on Si by an S bend filtered cathodic vacuum arc, achieving a continuous coverage on large areas free of macroparticles. Film thickness and mass density are measured by X-ray reflectivity: densities above 3 g/cm3 are found, indicating a significant sp3 content. The dispersion relations of surface acoustic waves are measured by SBS. We show that for thicknesses above ∼4 nm these waves can be described by a continuum elastic model based on a single homogeneous equivalent film. The elastic constants can then be obtained by fitting the dispersion relations, computed for given film properties, to the measured dispersion relations. For thicknesses of 3 nm or less qualitative differences among films are well measurable, but quantitative results are less reliable. We have thus shown that we can grow and characterise nanometer size tetrahedral amorphous carbon film, which maintain their high density and peculiar mechanical properties down to around 4 nm thickness, satisfying the requirements set for the hard disk coating material.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: This work is concerned with the creation of three-dimensional (3D) extended-field-of-view ultrasound from a set of volumes acquired using a mechanically swept 3D probe. 3D volumes of ultrasound data can be registered by attaching a position sensor to the probe; this can be an inconvenience in a clinical setting. A position sensor can also cause some misalignment due to patient movement and respiratory motion. We propose a combination of three-degrees-of-freedom image registration and an unobtrusively integrated inertial sensor for measuring orientation. The aim of this research is to produce a reliable and portable ultrasound system that is able to register 3D volumes quickly, making it suitable for clinical use. METHOD: As part of a feasibility study we recruited 28 pregnant females attending for routine obstetric scans to undergo 3D extended-field-of-view ultrasound. A total of 49 data sets were recorded. Each registered data set was assessed for correct alignment of each volume by two independent observers. RESULTS: In 77-83% of the data sets more than four consecutive volumes registered. The successful registration relies on good overlap between volumes and is adversely affected by advancing gestational age and foetal movement. CONCLUSION: The development of reliable 3D extended-field-of-view ultrasound may help ultrasound practitioners to demonstrate the anatomical relation of pathology and provide a convenient way to store data.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Half of the world's urban population will live in informal settlements or ‘slums’ by 2030. Affordable urban sanitation presents a unique set of challenges as the lack of space and resources to construct new latrines makes the de-sludging of existing pits necessary and is something that is currently done manually with significant associated health risks. Various mechanised technologies have therefore been developed to facilitate pit emptying, with the majority using a vacuum system to remove material from the top of the pit. However, this results in the gradual accumulation of unpumpable sludge at the bottom of the pit, which eventually fills the latrine and forces it to be abandoned. This study has developed a method for fluidising unpumpable pit latrine sludge, based on laboratory experiments using a harmless synthetic sludge. The implications for sludge treatment and disposal are discussed, and the classification of sludges according to the equipment required to remove them from the latrine is proposed. Finally, further work is suggested, including the ongoing development of a device to physically characterise latrine sludge in-situ within the pit.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In order to understand how unburned hydrocarbons emerge from SI engines and, in particular, how non-fuel hydrocarbons are formed and oxidized, a new gas sampling technique has been developed. A sampling unit, based on a combination of techniques used in the Fast Flame Ionization Detector (FFID) and wall-mounted sampling valves, was designed and built to capture a sample of exhaust gas during a specific period of the exhaust process and from a specific location within the exhaust port. The sampling unit consists of a transfer tube with one end in the exhaust port and the other connected to a three-way valve that leads, on one side, to a FFID and, on the other, to a vacuum chamber with a high-speed solenoid valve. Exhaust gas, drawn by the pressure drop into the vacuum chamber, impinges on the face of the solenoid valve and flows radially outward. Once per cycle during a specified crank angle interval, the solenoid valve opens and traps exhaust gas in a storage unit, from which gas chromatography (GC) measurements are made. The port end of the transfer tube can be moved to different locations longitudinally or radially, thus allowing spatial resolution and capturing any concentration differences between port walls and the center of the flow stream. Further, the solenoid valve's opening and closing times can be adjusted to allow sampling over a window as small as 0.6 ms during any portion of the cycle, allowing resolution of a crank angle interval as small as 15°CA. Cycle averaged total HC concentration measured by the FFID and that measured by the sampling unit are in good agreement, while the sampling unit goes one step further than the FFID by providing species concentrations. Comparison with previous measurements using wall-mounted sampling valves suggests that this sampling unit is fully capable of providing species concentration information as a function of air/fuel ratio, load, and engine speed at specific crank angles. © Copyright 1996 Society of Automotive Engineers, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A good quality graphene is transferred onto honeycomb-like CNTs arrays with inner supporting CNTs. The efficient field emission is demonstrated due to a high aspect ratio protrusions and graphene crack edges. A high efficient current density about 1.2 mA/cm2 at threshold electric field of 7.8 V/μm with a turn-on electric field of 1.8 V/μm at the current density of 10 μA/cm2 is observed due to high localized electric field. Stable field emission is tested in a vacuum chamber. The results are of significance to the development of Graphene based field emitters. © 2013 IEEE.