966 resultados para Transient Calibration


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Arterial hypertension is a major risk factor for ischemic stroke. However, the management of preexisting hypertension is still controversial in the treatment of acute stroke in hypertensive patients. The present study evaluates the influence of preserving hypertension during focal cerebral ischemia on stroke outcome in a rat model of chronic hypertension, the spontaneously hypertensive rats (SHR). Focal cerebral ischemia was induced by transient (1 h) occlusion of the middle cerebral artery, during which mean arterial blood pressure was maintained at normotension (110-120 mm Hg, group 1, n=6) or hypertension (160-170 mm Hg, group 2, n=6) using phenylephrine. T2-, diffusion- and perfusion-weighted MRI were performed serially at five different time points: before and during ischemia, and at 1, 4 and 7 days after ischemia. Lesion volume and brain edema were estimated from apparent diffusion coefficient maps and T2-weighted images. Regional cerebral blood flow (rCBF) was measured within and outside the perfusion deficient lesion and in the corresponding regions of the contralesional hemisphere. Neurological deficits were evaluated after reperfusion. Infarct volume, edema, and neurological deficits were significantly reduced in group 2 vs. group 1. In addition, higher values and rapid restoration of rCBF were observed in group 2, while rCBF in both hemispheres was significantly decreased in group 1. Maintaining preexisting hypertension alleviates ischemic brain injury in SHR by increasing collateral circulation to the ischemic region and allowing rapid restoration of rCBF. The data suggest that maintaining preexisting hypertension is a valuable approach to managing hypertensive patients suffering from acute ischemic stroke. Published by Elsevier B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mediastinal lymphadenomegaly secondary to hypervolemia is an underdiagnosed tomographic finding. Herein we describe, in a patient with normal cardiac function, findings of pulmonary congestion associated to lymph node enlargement. The nephrotic syndrome causing hypoalbuminemia, low plasma colloid osmotic pressure and augmented transcapillary fluid leakage was the probable cause of the radiological findings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To compare two methods of respiratory inductive plethysmography (RIP) calibration in three different positions. Methods: We evaluated 28 healthy subjects (18 women and 10 men), with a mean age of 25.4 +/- 3.9 years. For all of the subjects, isovolume maneuver calibration (ISOCAL) and qualitative diagnostic calibration (QDC) were used in the orthostatic, sitting, and supine positions. In order to evaluate the concordance between the two calibration methods, we used ANOVA and Bland-Altman plots. Results: The values of the constant of proportionality (X) were significantly different between ISOCAL and QDC in the three positions evaluated: 1.6 +/- 0.5 vs. 2.0 +/- 1.2, in the supine position, 2.5 +/- 0.8 vs. 0.6 +/- 0.3 in the sitting position, and 2.0 +/- 0.8 vs. 0.6 +/- 0.3 in the orthostatic position (p < 0.05 for all). Conclusions: Our results suggest that QDC is an inaccurate method for the calibration of RIP. The K values obtained with ISOCAL reveal that RIP should be calibrated for each position evaluated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Oxidative stress and mitochondrial impairment are essential in the ischemic stroke cascade and eventually lead to tissue injury. C-Phycocyanin (C-PC) has previously been shown to have strong antioxidant and neuroprotective actions. In the present study, we assessed the effects of C-PC on oxidative injury induced by tert-butylhydroperoxide (t-BOOH) in SH-SY5Y neuronal cells, on transient ischemia in rat retinas, and in the calcium/phosphate-induced impairment of isolated rat brain mitochondria (RBM). In SH-SY5Y cells, t-BOOH induced a significant reduction of cell viability as assessed by an MTT assay, and the reduction was effectively prevented by treatment with C-PC in the low micromolar concentration range. Transient ischemia in rat retinas was induced by increasing the intraocular pressure to 120 mmHg for 45 min, which was followed by 15 min of reperfusion. This event resulted in a cell density reduction to lower than 50% in the inner nuclear layer (INL), which was significantly prevented by the intraocular pre-treatment with C-PC for 15 min. In the RBM exposed to 3 mM phosphate and/or 100 mu M Ca2+, C-PC prevented in the low micromolar concentration range, the mitochondrial permeability transition as assessed by mitochondrial swelling, the membrane potential dissipation, the increase of reactive oxygen species levels and the release of the pro-apoptotic cytochrome c. In addition, C-PC displayed a strong inhibitory effect against an electrochemically-generated Fenton reaction. Therefore, C-PC is a potential neuroprotective agent against ischemic stroke, resulting in reduced neuronal oxidative injury and the protection of mitochondria from impairment. (C) 2012 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Charge transport and shelf-degradation of MEH-PPV thin-films were investigated through stationary (e.g. current versus voltage - JxV) and transient (e.g. Time-of-Flight - ToF, Dark-Injection Space-Charge-Limited Current - DI-SCLC, Charge Extraction by Linearly Increasing Voltage - CELN) current techniques. Charge carrier mobility in nanometric films was best characterized through JxV and DI-SCLC. It approaches 10(-6) cm(2)Ns under a SCLC regime with deep traps for light-emitting diode applications. ToF measurements performed on micrometric layers (i.e. - 3 mu m) confirmed studies in 100 nm-thick films as deposited in OLEDs. All results were comparable to a similar poly(para-phenylene vinylene) derivative, MDMO-PPV. Electrical properties extracted from thin-film transistors demonstrated mobility dependence on carrier concentration in the channel (similar to 10(-7)-10(-4) cm(2)/Vs). At low accumulated charge levels and reduced free carrier concentration, a perfect agreement to the previously cited techniques was observed. Degradation was verified through mobility reduction and changes in trap distribution of states. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The leaf area index (LAI) is a key characteristic of forest ecosystems. Estimations of LAI from satellite images generally rely on spectral vegetation indices (SVIs) or radiative transfer model (RTM) inversions. We have developed a new and precise method suitable for practical application, consisting of building a species-specific SVI that is best-suited to both sensor and vegetation characteristics. Such an SVI requires calibration on a large number of representative vegetation conditions. We developed a two-step approach: (1) estimation of LAI on a subset of satellite data through RTM inversion; and (2) the calibration of a vegetation index on these estimated LAI. We applied this methodology to Eucalyptus plantations which have highly variable LAI in time and space. Previous results showed that an RTM inversion of Moderate Resolution Imaging Spectroradiometer (MODIS) near-infrared and red reflectance allowed good retrieval performance (R-2 = 0.80, RMSE = 0.41), but was computationally difficult. Here, the RTM results were used to calibrate a dedicated vegetation index (called "EucVI") which gave similar LAI retrieval results but in a simpler way. The R-2 of the regression between measured and EucVI-simulated LAI values on a validation dataset was 0.68, and the RMSE was 0.49. The additional use of stand age and day of year in the SVI equation slightly increased the performance of the index (R-2 = 0.77 and RMSE = 0.41). This simple index opens the way to an easily applicable retrieval of Eucalyptus LAI from MODIS data, which could be used in an operational way.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background-Patients with acute coronary syndromes and history of stroke or transient ischemic attack (TIA) have an increased rate of recurrent cardiac events and intracranial hemorrhages. Methods and Results-We evaluated treatment effects of ticagrelor versus clopidogrel in patients with acute coronary syndrome with and without a history of prior stroke or TIA in the PLATelet inhibition and patient Outcomes (PLATO) trial. Of the 18 624 randomized patients, 1152 (6.2%) had a history of stroke or TIA. Such patients had higher rates of myocardial infarction (11.5% versus 6.0%), death (10.5% versus 4.9%), stroke (3.4% versus 1.2%), and intracranial bleeding (0.8% versus 0.2%) than patients without prior stroke or TIA. Among patients with a history of stroke or TIA, the reduction of the primary composite outcome and total mortality at 1 year with ticagrelor versus clopidogrel was consistent with the overall trial results: 19.0% versus 20.8% (hazard ratio, 0.87; 95% confidence interval, 0.66-1.13; interaction P=0.84) and 7.9% versus 13.0% (hazard ratio, 0.62; 95% confidence interval, 0.42-0.91). The overall PLATO-defined bleeding rates were similar: 14.6% versus 14.9% (hazard ratio, 0.99; 95% confidence interval, 0.71-1.37), and intracranial bleeding occurred infrequently (4 versus 4 cases, respectively). Conclusions-Patients with acute coronary syndrome with a prior history of ischemic stroke or TIA had higher rates of clinical outcomes than patients without prior stroke or TIA. However, the efficacy and bleeding results of ticagrelor in these high-risk patients were consistent with the overall trial population, with a favorable clinical net benefit and associated impact on mortality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background In ROCKET AF, rivaroxaban was non-inferior to adjusted-dose warfarin in preventing stroke or systemic embolism among patients with atrial fibrillation (AF). We aimed to investigate whether the efficacy and safety of rivaroxaban compared with warfarin is consistent among the subgroups of patients with and without previous stroke or transient ischaemic attack (TIA). Methods In ROCKET AF, patients with AF who were at increased risk of stroke were randomly assigned (1:1) in a double-blind manner to rivaroxaban 20 mg daily or adjusted dose warfarin (international normalised ratio 2-0-3.0). Patients and investigators were masked to treatment allocation. Between Dec 18,2006, and June 17,2009,14 264 patients from 1178 centres in 45 countries were randomly assigned. The primary endpoint was the composite of stroke or non-CNS systemic embolism. In this substudy we assessed the interaction of the treatment effects of rivaroxaban and warfarin among patients with and without previous stroke or TIA. Efficacy analyses were by intention to treat and safety analyses were done in the on-treatment population. ROCKET AF is registered with ClinicalTrials.gov, number NCT00403767. Findings 7468 (52%) patients had a previous stroke (n=4907) or TIA (n=2561) and 6796 (48%) had no previous stroke or TIA. The number of events per 100 person-years for the primary endpoint in patients treated with rivaroxaban compared with warfarin was consistent among patients with previous stroke or TIA (2.79% rivaroxaban vs 2.96% warfarin; hazard ratio [HR] 0-94,95% CI 0.77-1.16) and those without (1.44% vs 1.88%; 0.77, 0.58-1-01; interaction p=0.23). The number of major and non-major clinically relevant bleeding events per 100 person-years in patients treated with rivaroxaban compared with warfarin was consistent among patients with previous stroke or TIA (13.31% rivaroxaban vs 13.87% warfarin; HR 0.96,95% CI 0.87-1-07) and those without (16.69% vs 15.19%; 1.10, 0.99-1.21; interaction p=0.08). Interpretation There was no evidence that the relative efficacy and safety of rivaroxaban compared with warfarin was different between patients who had a previous stroke or TIA and those who had no previous stroke or TIA. These results support the use of rivaroxaban as an alternative to warfarin for prevention of recurrent as well as initial stroke in patients with AF.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Background Hemophilia A is a bleeding disorder caused by deficiency in coagulation factor VIII. Recombinant factor VIII (rFVIII) is an alternative to plasma-derived FVIII for the treatment of hemophilia A. However, commercial manufacturing of rFVIII products is inefficient and costly and is associated to high prices and product shortage, even in economically privileged countries. This situation may be solved by adopting more efficient production methods. Here, we evaluated the potential of transient transfection in producing rFVIII in serum-free suspension HEK 293 cell cultures and investigated the effects of different DNA concentration (0.4, 0.6 and 0.8 μg/106 cells) and repeated transfections done at 34° and 37°C. Results We observed a decrease in cell growth when high DNA concentrations were used, but no significant differences in transfection efficiency and in the biological activity of the rFVIII were noticed. The best condition for rFVIII production was obtained with repeated transfections at 34°C using 0.4 μg DNA/106 cells through which almost 50 IU of active rFVIII was produced six days post-transfection. Conclusion Serum-free suspension transient transfection is thus a viable option for high-yield-rFVIII production. Work is in progress to further optimize the process and validate its scalability.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

<p>[EN]This work presents the calibration and validation of an air quality finite element model applied to emissions from a thermal power plant located in Gran Canaria. The calibration is performed using genetic algorithms. To calibrate and validate the model, the authors use empirical measures of pollutants concentrations from 4 stations located nearby the power plant; an hourly record per station during 3 days is available. Measures from 3 stations will be used to calibrate, while validation will use measures from the remaining station&hellip;</p>

Relevância:

20.00% 20.00%

Publicador:

Resumo:

<p>[EN]This work presents the calibration and validation of an air quality finite element model applied to the surroundings of Jinamar electric power plant in Gran Canaria island (Spain). The model involves the generation of an adaptive tetrahedral mesh, the computation of an ambient wind field, the inclusion of the plume rise effect in the wind field, and the simulation of transport and reaction of pollutants. The main advantage of the model is the treatment of complex terrains that introduces an alternative to the standard implementation of current models. In addition, it improves the computational cost through the use of unstructured meshes...</p>