990 resultados para Tooth resorption
Resumo:
Background: Dental erosion manifests as cupped lesions on cusp apices and in fissures of teeth in patients from southeast Queensland referred with excessive tooth wear When found in young adults, these lesions may indicate early onset of active dental erosion. If the numbers and extent of cupped lesions increase with age, erosion may be a slow cumulative process. Methods: This cross-sectional study recorded the presence or absence and the relative sizes of cupped lesions from all cusps and occlusal fissures on premolar and permanent molar teeth from study models by image analysis. Type-specimens of cupped lesions were examined. Results: The Incidence by tooth reflected time in the mouth, post-tooth emergence. A linear increase in lesion number and size, with age, was found. However, cupped lesions occurred on mandibular first molar cusp apices as often, and attained greater extent, in adults under 27 years compared with older subjects. Conclusion: Marked differences were found between lesion number and size, between maxillary and mandibular molar sites that reflect differences in salivary protection against dental erosion. The significance of this study is that the mandibular first permanent molar indicates the age of onset and severity of dental erosion.
Resumo:
The hypothesis that growth hormone (GH) up-regulates the expression of enzymes, matrix proteins, and differentiation markers involved in mineralization of tooth and bone matrices was tested by the treatment of Lewis dwarf rats with GH over 5 days, The molar teeth and associated alveolar bone were processed for immunohistochemical demonstration of bone morphogenetic proteins 2 and 4 (BMP-2 and -4), bone morphogenetic protein type IA receptor (BMPR-IA), bone alkaline phosphatase (ALP), osteocalcin (OC), osteopontin (OPN), bone sialoprotein (BSP), and E11 protein (E11), The cementoblasts, osteoblasts, and periodontal ligament (PDL) cells responded to GH by expressing BMP-2 and -4, BMPR-IA, ALP, OC, and OPN and increasing the numbers of these cells. No changes were found in patterns of expression of the late differentiation markers BSP and E11 in response to GH, Thus, GH evokes expression of bone markers of early differentiation in cementoblasts, PDL cells, and osteoblasts of the periodontium. We propose that the induction of BMP-2 and -4 and their receptor by GH compliments the role of GH-induced insulin-like growth factor 1 (IGF-1) in promoting bone and tooth root formation.
Resumo:
Background. Mucogingival alterations are inherent to clefts and may be worsened by the several plastic surgeries required in these individuals. Objective. The aim of this study was to evaluate the prevalence, severity, and some possible etiologic factors of gingival recessions in teeth adjacent to the cleft. Study design. A total of 641 teeth ( maxillary canines and central incisors) of 193 individuals with cleft lip and/or palate were examined. A generalized linear model was used, and the Wilcoxon test was used to compare the recession with cleft types. Results. Comparison among cleft types as to the presence of recession revealed a statistically significant positive relationship for the maxillary right and left central incisors only in the group with left cleft lip, alveolus, and palate (P = .034). The most frequently affected tooth was the right maxillary canine (26.16%). Conclusion. The prevalence of recession in teeth close to the cleft was higher, although it was not very severe. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010; 109: 37-45)
Resumo:
The purpose of this study was to evaluate histologically the root surfaces of teeth submitted to orthodontic and surgical extrusion procedures in a dog model. Eighteen adult male dogs, divided into six groups of three dogs each, were used in the study Each animal underwent two procedures: rapid orthodontic extrusion and surgical extrusion of the maxillary lateral incisors. The animals were sacrificed to produce samples at 7, 14, 45, 90, 120, and 180 days after surgery for assessment of cross sections of the coronal, medial, and apical thirds of the treated teeth. At early time points, some active surface and inflammatory resorption was observed exclusively in the surgical extrusion group; however, samples collected at later times demonstrated functional repair of the resorption gaps in both groups. Ankylosis was observed as a minor event and was apparently of a transient nature in samples of the surgical extrusion group. The results demonstrate the importance of maintaining the periodontal ligament and cementum surface; both are vital for the prevention of root resorption. It may be postulated that orthodontic extrusion is more conservative and physiologic than surgical extrusion; however the results showed that function was restored in both groups. (Int J Periodontics Restorative Dent 2009;29:435-443.)
Resumo:
Objective: To evaluate whether teeth close to the cleft area present higher prevalence and severity of periodontal disease than teeth in other regions. Design: Cross-sectional. Setting: Hospital for Rehabilitation of Craniofacial Anomalies, University of Sao Paulo. Patients: There were 400 Individuals with complete unilateral or bilateral cleft lip and palate, aged 15 to 49 years, without any previous periodontal treatment. Main Outcome Measures: All clinical parameters were evaluated in six sites for each tooth. The arithmetic means were calculated for each sextant. Results: Of the sextants, 86.75% presented means of probing depth smaller than or equal to 3 mm. No sextant exhibited means of probing depth greater than or equal to 6 mm. There was a statistically significant difference (p < .001) in probing depth according to age, types of cleft, and sextant; 95.87% of sextants presented mean attachment levels smaller than or equal to 3 mm, The sextant with cleft did not present higher means of probing depth, clinical attachment level, plaque index, and gingival index. There was gingival bleeding in 99.08% of the sample and plaque In 97.40%. The type of cleft was not an Important factor Influencing the prevalence of periodontal disease. Age seems to be an Important factor influencing the prevalence and severity of periodontal disease for all aspects Investigated. Conclusions: Periodontal disease In individuals with clefts occurred in a similar manner as observed in other populations. The presence of the cleft does not seem to Increase the prevalence of the disease.
Resumo:
Objective: To compare the dental status of Brazilian and Canadian elderly populations with respect to socioeconomic and quality of life factors. Materials and methods: A total of 496 adults aged 60-75 years, having four or more teeth, and physically and cognitively suitable for a clinical oral examination were included. Subjects answered questions concerning their lifestyle and completed the Geriatric Oral Health Assessment Index (GOHAI) questionnaire. Results: In all populations, the majority were females, aged between 60 and 65 years and married. Although the Canadian New Immigrant population had lower mean income, they had more remaining teeth (23.04 +/- 6.1), more functional teeth (sound and restored teeth) (14.92 +/- 5.7), more sound teeth (15.40 +/- 7.6), but more carious teeth (2.97 +/- 3.0). The Brazilian population had higher numbers of restored teeth (12.26 +/- 6.8) and fewer remaining teeth (17.80 +/- 7.6). In all populations, females, married and younger (60-65 years old) adults were more likely to retain 20 or more teeth. The mean GOHAI scores were similar for Canadians (40.55 +/- 5.7) and Canadian New Immigrants (39.28 +/- 6.5), but were higher than that among Brazilians (31.97 +/- 8.9). Conclusions: The numbers of remaining teeth were related to greater education and higher income status for Brazilian and Canadian populations. However, Canadian New Immigrants with lower income and education retained more teeth than the other populations.
Resumo:
This study evaluated the fracture resistance of endodontically treated teeth restored with prefabricated carbon fiber posts and varying quantities of coronal dentin. Sixty freshly extracted upper canines were randomly divided into groups of 10 teeth each. The specimens were exposed to 250,000 cycles in a controlled chewing simulator. All intact specimens were subjected to a static load (N) in a universal testing machine at 45 degrees to the long axis. Data were analyzed by 1-way analysis of variance and Tukey test (alpha = .05). Significant differences (P < .001) were found among the mean fracture forces of the test groups (positive control, 0 mm, 1 mm, 2 mm, 3 mm, and negative control groups: 1022.82 N, 1008.22 N, 1292.52 N, 1289.19 N, 1255.38 N, and 1582.11, respectively). These results suggested that the amount of coronal dentin did not significantly increase the fracture resistance of endodontically treated teeth restored with prefabricated carbon fiber post and composite resin core. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2008;106:e52-e57)
Resumo:
Purpose This 24-month randomized paired tooth clinical study evaluated the performance of All Bond 3 used in the simplified (2-step) and full (3-step) versions Methods 33 patients, with at least two similar sized non-carious cervical lesions participated in this study A total of 66 restorations were placed, half using the 2-step All Bond 3 (AB3-2) and the other half using 3-step All Bond 3 (AB3-3) The restorations were placed incrementally using the composite resin Aelite The restorations were evaluated at baseline and after 6, 12 and 24 months following the modified USPHS criteria Statistical differences between the adhesive were tested using with McNemar`s test and clinical performance over time for each material with the Fisher`s exact test (alpha= 0 05) Results After 24 months, six AB3-2 and four AB3-3 were rated as bravo for marginal discoloration but did not differ from each other significantly (P> 0 05) The retention rates at 24 months of AB3-2 and AB3-3 were 90 9% and 97 0%, respectively (P> 0 05) (Am J Dent 2010,23 231-236)
Resumo:
Objectives: To evaluate the effect of framework design on the fatigue life and failure modes of metal ceramic (MC, Ni-Cr alloy core, VMK 95 porcelain veneer), glass-infiltrated alumina (ICA, In-Ceram Alumina/VM7), and veneered yttria-stabilized tetragonal zirconia polycrystals (Y-TZP, IPSe.max ZirCAD/IPS e.max,) crowns. Methods: Sixty composite resin tooth replicas of a prepared maxillary first molar were produced to receive crowns systems of a standard (MCs, ICAs, and Y-TZPs, n = 10 each) or a modified framework design (MCm, ICAm, and Y-TZPm, n = 10 each). Fatigue loading was delivered with a spherical steel indenter (3.18 mm radius) on the center of the occlusal surface using r-ratio fatigue (30-300 N) until completion of 10(6) cycles or failure. Fatigue was interrupted every 125,000 cycles for damage evaluation. Weibull distribution fits and contour plots were used for examining differences between groups. Failure mode was evaluated by light polarized and SEM microscopy. Results: Weibull analysis showed the highest fatigue life for MC crowns regardless of framework design. No significant difference (confidence bound overlaps) was observed between ICA and Y-TZP with or without framework design modification. Y-TZPm crowns presented fatigue life in the range of MC crowns. No porcelain veneer fracture was observed in the MC groups, whereas ICAs presented bulk fracture and ICAm failed mainly through the veneer. Y-TZP crowns failed through chipping within the veneer, without core fractures. Conclusions: Framework design modification did not improve the fatigue life of the crown systems investigated. Y-TZPm crowns showed comparable fatigue life to MC groups. Failure mode varied according to crown system. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
Objectives To compare the reliability of the disto-facial (DF) and mesio-lingual (ML) cusps of an anatomically correct zirconia (Y-TZP) crown system The research hypotheses tested were (1) fatigue reliability and failure mode are similar for the ML and DF cusps, (2) failure mode of one cusp does not affect the failure of the other Methods The average dimensions of a mandibular first molar crown were imported into CAD software, a tooth preparation was modelled by 1 5 mm marginal high reduction of proximal walls and occlusal surface by 2 0 mm The CAD-based tooth preparation was milled and used as a die to fabricate crowns (n = 14) with porcelain veneer on a 0 5 mm Y-TZP core. Crowns were cemented on composite reproductions of the tooth preparation The crowns were step-stress mouth motion fatigued with sliding (0 7 mm) a tungsten-carbide indenter of 6 25 mm diameter down on the inclines of either the DF or ML cusps Use level probability Weibull curve with use stress of 200 N and the reliability for completion of a mission of 50,000 cycles at 200 N load were calculated Results Reliability for a 200 N at 50,000 cycles mission was not different between tested cusps SEM imaging showed large cohesive failures within the veneer for the ML and smaller for the DF Fractures originated from the contact area regardless of the cusp loaded Conclusion No significant difference on fatigue reliability was observed between the DF compared to the ML cusp Fracture of one cusp did not affect the other (c) 2010 Elsevier Ltd All rights reserved
Resumo:
Objectives: This study compared the reliability and fracture patterns of zirconia cores veneered with pressable porcelain submitted to either axial or off-axis sliding contact fatigue. Methods: Forty-two Y-TZP plates (12 mm x 12 mm x 0.5 mm) veneered with pressable porcelain (12 mm x 12 mm x 1.2 mm) and adhesively luted to water aged composite resin blocks (12 mm x 12 mm x 4 mm) were stored in water at least 7 days prior to testing. Profiles for step-stress fatigue (ratio 3:2:1) were determined from single load to fracture tests (n = 3). Fatigue loading was delivered on specimen either on axial (n = 18) or off-axis 30 degrees angulation (n = 18) to simulate posterior tooth cusp inclination creating a 0.7 mm slide. Single load and fatigue tests utilized a 6.25 mm diameter WC indenter. Specimens were inspected by means of polarized-light microscope and SEM. Use level probability Weibull curves were plotted with 2-sided 90% confidence bounds (CB) and reliability for missions of 50,000 cycles at 200 N (90% CB) were calculated. Results: The calculated Weibull Beta was 3.34 and 2.47 for axial and off-axis groups, respectively, indicating that fatigue accelerated failure in both loading modes. The reliability data for a mission of 50,000 cycles at 200 N load with 90% CB indicates no difference between loading groups. Deep penetrating cone cracks reaching the core-veneer interface were observed in both groups. Partial cones due to the sliding component were observed along with the cone cracking for the off-axis group. No Y-TZP core fractures were observed. Conclusions: Reliability was not significantly different between axial and off-axis mouth-motion fatigued pressed over Y-TZP cores, but incorporation of sliding resulted in more aggressive damage on the veneer. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
This study evaluated the stress levels at the core layer and the veneer layer of zirconia crowns (comprising an alternative core design vs. a standard core design) under mechanical/thermal simulation, and subjected simulated models to laboratory mouth-motion fatigue. The dimensions of a mandibular first molar were imported into computer-aided design (CAD) software and a tooth preparation was modeled. A crown was designed using the space between the original tooth and the prepared tooth. The alternative core presented an additional lingual shoulder that lowered the veneer bulk of the cusps. Finite element analyses evaluated the residual maximum principal stresses fields at the core and veneer of both designs under loading and when cooled from 900 degrees C to 25 degrees C. Crowns were fabricated and mouth-motion fatigued, generating master Weibull curves and reliability data. Thermal modeling showed low residual stress fields throughout the bulk of the cusps for both groups. Mechanical simulation depicted a shift in stress levels to the core of the alternative design compared with the standard design. Significantly higher reliability was found for the alternative core. Regardless of the alternative configuration, thermal and mechanical computer simulations showed stress in the alternative core design comparable and higher to that of the standard configuration, respectively. Such a mechanical scenario probably led to the higher reliability of the alternative design under fatigue.
Resumo:
Introduction: The aims of this study were to evaluate the distances between the mandibular permanent teeth and the alveolar process in Brazilians with normal occlusion and to compare them with normal American values. Methods: We used 59 mandibular casts from untreated subjects who had permanent dentition and the 6 keys to normal occlusion. A computer program was used to calculate the distances between the dental reference points and the alveolar process for each tooth. The mean values were then compared to the normal values by applying the Student t test at a significance level of 0.05. Results: The results showed a progressive increase of these distances from the anterior region (incisors) to the posterior region (molars), from 0.00 to 2.49 mm. All measurements had statistically significant differences from the American sample, except for the values for canines and first premolars. Conclusions: Brazilians with normal occlusion have more lingual crown positions for the incisors, second premolars, and molars compared with Americans with normal occlusion. Although these findings were statistically significant, they are unlikely to be clinically significant. (Am J Orthod Dentofacial Orthop 2010; 137: 308.e1-308.e4)
Resumo:
Purpose: The objective of this study was to evaluate the stress on the cortical bone around single body dental implants supporting mandibular complete fixed denture with rigid (Neopronto System-Neodent) or semirigid splinting system (Barra Distal System-Neodent). Methods and Materials: Stress levels on several system components were analyzed through finite element analysis. Focusing on stress concentration at cortical bone around single body dental implants supporting mandibular complete fixed dentures with rigid ( Neopronto System-Neodent) or semirigid splinting system ( Barra Distal System-Neodent), after axial and oblique occlusal loading simulation, applied in the last cantilever element. Results: The results showed that semirigid implant splinting generated lower von Mises stress in the cortical bone under axial loading. Rigid implant splinting generated higher von Mises stress in the cortical bone under oblique loading. Conclusion: It was concluded that the use of a semirigid system for rehabilitation of edentulous mandibles by means of immediate implant-supported fixed complete denture is recommended, because it reduces stress concentration in the cortical bone. As a consequence, bone level is better preserved, and implant survival is improved. Nevertheless, for both situations the cortical bone integrity was protected, because the maximum stress level findings were lower than those pointed in the literature as being harmful. The maximum stress limit for cortical bone (167 MPa) represents the threshold between plastic and elastic state for a given material. Because any force is applied to an object, and there is no deformation, we can conclude that the elastic threshold was not surpassed, keeping its structural integrity. If the force is higher than the plastic threshold, the object will suffer permanent deformation. In cortical bone, this represents the beginning of bone resorption and/or remodeling processes, which, according to our simulated loading, would not occur. ( Implant Dent 2010; 19:39-49)
A modified orthodontic protocol for advanced periodontal disease in Class II division 1 malocclusion
Resumo:
An interdisciplinary approach is often the best option for achieving a predictable outcome for an adult patient with complex clinical problems. This case report demonstrates the combined periodontal/orthodontic treatment for a 49-year-old woman presenting with a Class II Division 1 malocclusion with moderate maxillary anterior crowding, a 9-mm overjet, and moderate to severe bone loss as the main characteristics of the periodontal disease. The orthodontic treatment included 2 maxillary first premolar extractions through forced extrusion. Active orthodontic treatment was completed in 30 months. The treatment outcomes, including the periodontal condition, were stable 17 months after active orthodontic treatment. The advantages of this interdisciplinary approach are discussed. Periodontally compromised orthodontic patients can be satisfactorily treated, achieving most of the conventional orthodontic goals, if a combined orthodontic/periodontic approach is used. (Am J Orthod Dentofacial Orthop 2011; 139:S133-44)