951 resultados para Time-domain nuclear magnetic resonance relaxometry
Resumo:
Right ventricular (RV) systolic function is prognostically important, but its assessment by echocardiography remains challenging, in part because of the multitude of available measurement methods. The purpose of this prospective study was to rank these methods against the reference of RV ejection fraction (EF) as obtained in a broad clinical population by magnetic resonance imaging (MRI).
Resumo:
The current hypothesis that human pulmonary alveolarization is complete by 3 years is contradicted by new evidence of alveolarization throughout adolescence in mammals.
Resumo:
To evaluate a new isotropic 3D proton-density, turbo-spin-echo sequence with variable flip-angle distribution (PD-SPACE) sequence compared to an isotropic 3D true-fast-imaging with steady-state-precession (True-FISP) sequence and 2D standard MR sequences with regard to the new 3D magnetic resonance observation of cartilage repair tissue (MOCART) score.
Resumo:
To investigate the inhomogeneity of radiofrequency fields at higher field strengths that can interfere with established volumetric methods, in particular for the determination of visceral (VAT) and subcutaneous adipose tissue (SCAT). A versatile, interactive sparse sampling (VISS) method is proposed to determine VAT, SCAT, and also total body volume (TBV).
Resumo:
To show the effect of standard magnetic resonance imaging (MRI) in patients with suspected appendicitis on negative laparotomy and perforation rate. Moreover, the economic impact on hospital resources was evaluated.
Resumo:
Magnetic iron oxide nanoparticles have found application as contrast agents for magnetic resonance imaging (MRI) and as switchable drug delivery vehicles. Their stabilization as colloidal carriers remains a challenge. The potential of poly(ethylene imine)-g-poly(ethylene glycol) (PEGPEI) as stabilizer for iron oxide (γ-Fe₂O₃) nanoparticles was studied in comparison to branched poly(ethylene imine) (PEI). Carrier systems consisting of γ-Fe₂O₃-PEI and γ-Fe₂O₃-PEGPEI were prepared and characterized regarding their physicochemical properties including magnetic resonance relaxometry. Colloidal stability of the formulations was tested in several media and cytotoxic effects in adenocarcinomic epithelial cells were investigated. Synthesized γ-Fe₂O₃ cores showed superparamagnetism and high degree of crystallinity. Diameters of polymer-coated nanoparticles γ-Fe₂O₃-PEI and γ-Fe₂O₃-PEGPEI were found to be 38.7 ± 1.0 nm and 40.4 ± 1.6 nm, respectively. No aggregation tendency was observable for γ-Fe₂O₃-PEGPEI over 12 h even in high ionic strength media. Furthermore, IC₅₀ values were significantly increased by more than 10-fold when compared to γ-Fe₂O₃-PEI. Formulations exhibited r₂ relaxivities of high numerical value, namely around 160 mM⁻¹ s⁻¹. In summary, novel carrier systems composed of γ-Fe₂O₃-PEGPEI meet key quality requirements rendering them promising for biomedical applications, e.g. as MRI contrast agents.
Resumo:
Electromagnetic fields arising from magnetic resonance imaging (MRI) can cause various clinically relevant functional disturbances in patients with cardiac pacemakers. Consequently, an implanted pacemaker is generally considered a contraindication for an MRI scan. With approximately 60 million MRI scans performed worldwide per year, MRI may be indicated for an estimated majority of pacemaker patients during the lifetime of their pacemakers. The availability of MR conditional pacemakers with CE labelling is of particular advantage since they allow the safe use of pacemakers in MRI. In this article the current state of knowledge on pacemakers and MR imaging is discussed. We present the results of a survey conducted among Swiss radiologists to assess current practice in patients with pacemakers.
Resumo:
Diagnosis, staging, and treatment monitoring are still suboptimal for most genitourinary tumours. Diffusion-weighted magnetic resonance imaging (DW-MRI) has already shown promise as a noninvasive imaging modality in the early detection of microstructural and functional changes in several pathologies of various organs.
Resumo:
The purpose of this study was to identify the anatomy of pineal region venous complex using neuronavigation software when distorted by the presence of a space-occupying lesion and to describe the anatomical relationship between lesion and veins. Moreover we discuss its influence on the choice of the surgical strategy.
Resumo:
The most important factor for successful free-flap transfer and replantations is a well-executed anastomosis. The aim of this study is to assess blood flow after laser assisted arterial microanastomosis (LAMA) using a 1.9 μm diode laser.
Resumo:
Many metabolites in the proton magnetic resonance spectrum undergo magnetization exchange with water, such as those in the downfield region (6.0-8.5 ppm) and the upfield peaks of creatine, which can be measured to reveal additional information about the molecular environment. In addition, these resonances are attenuated by conventional water suppression techniques complicating detection and quantification. To characterize these metabolites in human skeletal muscle in vivo at 3 T, metabolite cycled non-water-suppressed spectroscopy was used to conduct a water inversion transfer experiment in both the soleus and tibialis anterior muscles. Resulting median exchange-independent T(1) times for the creatine methylene resonances were 1.26 and 1.15 s, and for the methyl resonances were 1.57 and 1.74 s, for soleus and tibialis anterior muscles, respectively. Magnetization transfer rates from water to the creatine methylene resonances were 0.56 and 0.28 s(-1) , and for the methyl resonances were 0.39 and 0.30 s(-1) , with the soleus exhibiting faster transfer rates for both resonances, allowing speculation about possible influences of either muscle fibre orientation or muscle composition on the magnetization transfer process. These water magnetization transfer rates observed without water suppression are in good agreement with earlier reports that used either postexcitation water suppression in rats, or short CHESS sequences in human brain and skeletal muscle.
Resumo:
Several practical obstacles in data handling and evaluation complicate the use of quantitative localized magnetic resonance spectroscopy (qMRS) in clinical routine MR examinations. To overcome these obstacles, a clinically feasible MR pulse sequence protocol based on standard available MR pulse sequences for qMRS has been implemented along with newly added functionalities to the free software package jMRUI-v5.0 to make qMRS attractive for clinical routine. This enables (a) easy and fast DICOM data transfer from the MR console and the qMRS-computer, (b) visualization of combined MR spectroscopy and imaging, (c) creation and network transfer of spectroscopy reports in DICOM format, (d) integration of advanced water reference models for absolute quantification, and (e) setup of databases containing normal metabolite concentrations of healthy subjects. To demonstrate the work-flow of qMRS using these implementations, databases for normal metabolite concentration in different regions of brain tissue were created using spectroscopic data acquired in 55 normal subjects (age range 6-61 years) using 1.5T and 3T MR systems, and illustrated in one clinical case of typical brain tumor (primitive neuroectodermal tumor). The MR pulse sequence protocol and newly implemented software functionalities facilitate the incorporation of qMRS and reference to normal value metabolite concentration data in daily clinical routine. Magn Reson Med, 2013. © 2012 Wiley Periodicals, Inc.
Resumo:
OBJECTIVE: To determine interobserver and intraobserver agreement for results of low-field magnetic resonance imaging (MRI) in dogs with and without disk-associated wobbler syndrome (DAWS). DESIGN: Validation study. ANIMALS: 21 dogs with and 23 dogs without clinical signs of DAWS. PROCEDURES: For each dog, MRI of the cervical vertebral column was performed. The MRI studies were presented in a randomized sequence to 4 board-certified radiologists blinded to clinical status. Observers assessed degree of disk degeneration, disk-associated and dorsal compression, alterations in intraspinal signal intensity (ISI), vertebral body abnormalities, and new bone formation and categorized each study as originating from a clinically affected or clinically normal dog. Interobserver agreement was calculated for 44 initial measurements for each observer. Intraobserver agreement was calculated for 11 replicate measurements for each observer. RESULTS: There was good interobserver agreement for ratings of disk degeneration and vertebral body abnormalities and moderate interobserver agreement for ratings of disk-associated compression, dorsal compression, alterations in ISI, new bone formation, and suspected clinical status. There was very good intraobserver agreement for ratings of disk degeneration, disk-associated compression, alterations in ISI, vertebral body abnormalities, and suspected clinical status. There was good intraobserver agreement for ratings of dorsal compression and new bone formation. Two of 21 clinically affected dogs were erroneously categorized as clinically normal, and 4 of 23 clinically normal dogs were erroneously categorized as clinically affected. CONCLUSIONS AND CLINICAL RELEVANCE: Results suggested that variability exists among observers with regard to results of MRI in dogs with DAWS and that MRI could lead to false-positive and false-negative assessments.