935 resultados para Threshold mold


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cyclostationary models for the diagnostic signals measured on faulty rotating machineries have proved to be successful in many laboratory tests and industrial applications. The squared envelope spectrum has been pointed out as the most efficient indicator for the assessment of second order cyclostationary symptoms of damages, which are typical, for instance, of rolling element bearing faults. In an attempt to foster the spread of rotating machinery diagnostics, the current trend in the field is to reach higher levels of automation of the condition monitoring systems. For this purpose, statistical tests for the presence of cyclostationarity have been proposed during the last years. The statistical thresholds proposed in the past for the identification of cyclostationary components have been obtained under the hypothesis of having a white noise signal when the component is healthy. This need, coupled with the non-white nature of the real signals implies the necessity of pre-whitening or filtering the signal in optimal narrow-bands, increasing the complexity of the algorithm and the risk of losing diagnostic information or introducing biases on the result. In this paper, the authors introduce an original analytical derivation of the statistical tests for cyclostationarity in the squared envelope spectrum, dropping the hypothesis of white noise from the beginning. The effect of first order and second order cyclostationary components on the distribution of the squared envelope spectrum will be quantified and the effectiveness of the newly proposed threshold verified, providing a sound theoretical basis and a practical starting point for efficient automated diagnostics of machine components such as rolling element bearings. The analytical results will be verified by means of numerical simulations and by using experimental vibration data of rolling element bearings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper investigates the potential of pulsed power to sterilize hard and soft tissues and its impact on their physico-mechanical properties. It hypothesizes that pulsed plasma can sterilize both vascular and avascular tissues and the transitive layers in between without deleterious effects on their functional characteristics. Cartilage/bone laminate was chosen as a model to demonstrate the concept, treated at low temperature, at atmospheric pressure, in short durations and in buffered environment using a purposed-built pulsed power unit. Input voltage and time of exposure were assigned as controlling parameters in a full factorial design of experiment to determine physical and mechanical alteration pre- and post-treatment. The results demonstrated that, discharges of 11 kV sterilized samples in 45 s, reducing intrinsic elastic modules from 1.4 ± 0.9 to 0.9 ± 0.6 MPa. There was a decrease of 14.1 % in stiffness and 27.8 % in elastic-strain energy for the top quartile. Mechanical impairment was directly proportional to input voltage (P value < 0.05). Bacterial inactivation was proportional to treatment time for input voltages above 32 V (P < 0.001; R Sq = 0.98). Thermal analysis revealed that helix-coil transition decelerated with exposure time and collagen fibrils were destabilized as denaturation enthalpy reduced by 200 μV. We concluded by presenting a safe operating threshold for pulsed power plasma as a feasible protocol for effective sterilization of connective tissues with varying level of loss in mechanical robustness which we argue to be acceptable in certain medical and tissue engineering application.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction Stretching of tissue stimulates angiogenesis but increased motion at a fracture site hinders revascularisation. In vitro studies have indicated that mechanical stimuli promote angiogenic responses in endothelial cells, but can either inhibit or enhance responses when applied directly to angiogenesis assays. We anticipated that cyclic tension applied during endothelial network assembly would increase vascular structure formation up to a certain threshold. Methods Fibroblast/HUVEC co-cultures were subjected to cyclic equibiaxial strain (1 Hz; 6 h/day; 7 days) using the FlexerCell FX-4000T system and limiting rings for simultaneous application of multiple strain magnitudes (0–13%). Cells were labelled using anti-PECAM-1, and image analysis provided measures of endothelial network length and numbers of junctions. Results Cyclic stretching had no significant effect on the total length of endothelial networks (P > 0.2) but resulted in a strain-dependent decrease in branching and localised alignments of endothelial structures, which were in turn aligned with the supporting fibroblastic construct. Conclusion The organisation of endothelial networks under cyclic strain is dominated by structural adaptation to the supporting construct. It may be that, in fracture healing, the formation and integrity of the granulation tissue and callus is ultimately critical in revascularisation and its failure under severe strain conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fusion techniques can be used in biometrics to achieve higher accuracy. When biometric systems are in operation and the threat level changes, controlling the trade-off between detection error rates can reduce the impact of an attack. In a fused system, varying a single threshold does not allow this to be achieved, but systematic adjustment of a set of parameters does. In this paper, fused decisions from a multi-part, multi-sample sequential architecture are investigated for that purpose in an iris recognition system. A specific implementation of the multi-part architecture is proposed and the effect of the number of parts and samples in the resultant detection error rate is analysed. The effectiveness of the proposed architecture is then evaluated under two specific cases of obfuscation attack: miosis and mydriasis. Results show that robustness to such obfuscation attacks is achieved, since lower error rates than in the case of the non-fused base system are obtained.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aims Corneal nerve morphology and corneal sensation threshold have recently been explored as potential surrogate markers for the evaluation of diabetic neuropathy. We present the baseline findings of the ‘Longitudinal Assessment of Neuropathy in type 1 Diabetes using novel ophthalmic Markers’(LANDMark) study. Methods The LANDMark study is a 4-year, two-site, natural history study of three participant groups: type 1 diabetes with neuropathy (T1W), type 1 diabetes without neuropathy (T1WO) and control participants without diabetes or neuropathy. All participants undergo a detailed annual assessment of neuropathy including corneal nerve parameters measured using corneal confocal microscopy and corneal sensitivity measured using non-contact corneal aesthesiometry. Results 76 T1W, 166 T1WO and 154 control participants were enrolled into the study. Corneal sensation threshold (mbars) was significantly higher (i.e. sensitivity was lower) in T1W (1.0 ± 1.1) than T1WO (0.7 ± 0.7) and controls (0.6 ± 0.4) (p < 0.001), with no difference between T1WO and controls. Corneal nerve fibre length was lower in T1W (14.0 ± 6.4 mm/mm2) compared to T1WO (19.1 ± 5.8 mm/mm2) and controls (23.2 ± 6.3 mm/mm2) (p < 0.001). Corneal nerve fibre length was lower in T1WO compared to controls. Conclusions The LANDMark baseline findings confirm a reduction in corneal sensitivity only in Type 1 patients with neuropathy. However, corneal nerve fibre length is reduced even in Type 1 patients without neuropathy with an even greater deficit in Type 1 patients with neuropathy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Operating in vegetated environments is a major challenge for autonomous robots. Obstacle detection based only on geometric features causes the robot to consider foliage, for example, small grass tussocks that could be easily driven through, as obstacles. Classifying vegetation does not solve this problem since there might be an obstacle hidden behind the vegetation. In addition, dense vegetation typically needs to be considered as an obstacle. This paper addresses this problem by augmenting probabilistic traversability map constructed from laser data with ultra-wideband radar measurements. An adaptive detection threshold and a probabilistic sensor model are developed to convert the radar data to occupancy probabilities. The resulting map captures the fine resolution of the laser map but clears areas from the traversability map that are induced by obstacle-free foliage. Experimental results validate that this method is able to improve the accuracy of traversability maps in vegetated environments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose Over the past decade, corneal nerve morphology and corneal sensation threshold have been explored as potential surrogate markers for the evaluation of diabetic neuropathy. We present the baseline findings of a Longitudinal Assessment of Neuropathy in Diabetes using novel ophthalmic Markers (LANDMark). Methods The LANDMark Study is a 5-year, two-site, natural history (observational) study of individuals with Type 1 diabetes stratified into those with (T1W) and without (T1WO) neuropathy according to the Toronto criteria, and control subjects. All study participants undergo detailed annual assessment of neuropathy including corneal nerve parameters measured using corneal confocal microscopy and corneal sensitivity measured using non-contact corneal esthesiometry. Results 396 eligible individuals (208 in Brisbane and 188 in Manchester) were assessed: 76 T1W, 166 T1WO and 154 controls. Corneal sensation threshold (mbars) was significantly higher in T1W (1.0 ± 1.1) than T1WO (0.7 ± 0.7) and controls (0.6 ± 0.4) (P=0.002); post-hoc analysis (PHA) revealed no difference between T1WO and controls (Tukey HSD, P=0.502). Corneal nerve fiber length (mm/mm2) (CNFL) was lower in T1W (13.8 ± 6.4) than T1WO (19.1 ± 5.8) and controls (23.2 ± 6.3) (P<0.001); PHA revealed CNFL to be lower in T1W than T1WO, and lower in both of these groups than controls (P<0.001). Corneal nerve branch density (branches/mm2) (CNBD) was significantly lower in T1W (40 ± 32) than T1WO (62 ± 37) and controls (83 ± 46) (P<0.001); PHA showed CNBD was lower in T1W than T1WO, and lower in both groups than controls (P<0.001). Alcohol and cigarette consumption did not differ between groups, although age, BMI, BP, waist circumference, HbA1c, albumin-creatinine ratio, and cholesterol were slightly greater in T1W than T1WO (p<0.05). Some site differences were observed. Conclusions The LANDMark baseline findings confirm that corneal sensitivity and corneal nerve morphometry can detect differences in neuropathy status in individuals with Type 1 diabetes and healthy controls. Corneal nerve morphology is significantly abnormal even in diabetic patients ‘without neuropathy’ compared to control participants. Results of the longitudinal trial will assess the capability of these tests for monitoring change in these parameters over time as potential surrogate markers for neuropathy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Endurance exercise can cause immunosuppression and increase the risk of upper respiratory illness. The present study examined changes in the secretion of T helper (Th) cell cytokines after endurance exercise. Ten highly trained road cyclists [mean±SEM: age 24.2±1.7 years; height 1.82±0.02 m; body mass 73.8±2.0 kg; peak oxygen uptake 65.9±2.3 mL/(kg•min)] performed 2 h of cycling exercise at 90% of the second ventilatory threshold. Peripheral blood mononuclear cells were isolated and stimulated with phytohemagglutinin. Plasma cortisol concentrations and the concentration of Th1/Th2/Th17 cell cytokines were examined. Data were analyzed using both traditional statistics and magnitude-based inferences. Results revealed a significant decrease in plasma cortisol at 4–24 h postexercise compared with pre-exercise values. Qualitative analysis revealed postexercise changes in concentrations of plasma cortisol, IL-2, TNF, IL-4, IL-6, IL-10, and IL-17A compared with pre-exercise values. A Th1/Th2 shift was evident immediately postexercise. Furthermore, for multiple cytokines, including IL-2 and TNF (Th1), IL-6 and IL-10 (Th2), and IL-17 (Th17), no meaningful change in concentration occurred until more than 4 h postexercise, highlighting the duration of exercise-induced changes in immune function. These results demonstrate the importance of considering “clinically” significant versus statistically significant changes in immune cell function after exercise.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose This work introduces the concept of very small field size. Output factor (OPF) measurements at these field sizes require extremely careful experimental methodology including the measurement of dosimetric field size at the same time as each OPF measurement. Two quantifiable scientific definitions of the threshold of very small field size are presented. Methods A practical definition was established by quantifying the effect that a 1 mm error in field size or detector position had on OPFs, and setting acceptable uncertainties on OPF at 1%. Alternatively, for a theoretical definition of very small field size, the OPFs were separated into additional factors to investigate the specific effects of lateral electronic disequilibrium, photon scatter in the phantom and source occlusion. The dominant effect was established and formed the basis of a theoretical definition of very small fields. Each factor was obtained using Monte Carlo simulations of a Varian iX linear accelerator for various square field sizes of side length from 4 mm to 100 mm, using a nominal photon energy of 6 MV. Results According to the practical definition established in this project, field sizes < 15 mm were considered to be very small for 6 MV beams for maximal field size uncertainties of 1 mm. If the acceptable uncertainty in the OPF was increased from 1.0 % to 2.0 %, or field size uncertainties are 0.5 mm, field sizes < 12 mm were considered to be very small. Lateral electronic disequilibrium in the phantom was the dominant cause of change in OPF at very small field sizes. Thus the theoretical definition of very small field size coincided to the field size at which lateral electronic disequilibrium clearly caused a greater change in OPF than any other effects. This was found to occur at field sizes < 12 mm. Source occlusion also caused a large change in OPF for field sizes < 8 mm. Based on the results of this study, field sizes < 12 mm were considered to be theoretically very small for 6 MV beams. Conclusions Extremely careful experimental methodology including the measurement of dosimetric field size at the same time as output factor measurement for each field size setting and also very precise detector alignment is required at field sizes at least < 12 mm and more conservatively < 15 mm for 6 MV beams. These recommendations should be applied in addition to all the usual considerations for small field dosimetry, including careful detector selection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study used automated data processing techniques to calculate a set of novel treatment plan accuracy metrics, and investigate their usefulness as predictors of quality assurance (QA) success and failure. 151 beams from 23 prostate and cranial IMRT treatment plans were used in this study. These plans had been evaluated before treatment using measurements with a diode array system. The TADA software suite was adapted to allow automatic batch calculation of several proposed plan accuracy metrics, including mean field area, small-aperture, off-axis and closed-leaf factors. All of these results were compared the gamma pass rates from the QA measurements and correlations were investigated. The mean field area factor provided a threshold field size (5 cm2, equivalent to a 2.2 x 2.2 cm2 square field), below which all beams failed the QA tests. The small aperture score provided a useful predictor of plan failure, when averaged over all beams, despite being weakly correlated with gamma pass rates for individual beams. By contrast, the closed leaf and off-axis factors provided information about the geometric arrangement of the beam segments but were not useful for distinguishing between plans that passed and failed QA. This study has provided some simple tests for plan accuracy, which may help minimise time spent on QA assessments of treatments that are unlikely to pass.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Shared Material on Dying is a trio/solo work commissioned by Jenny Roche and the Dublin Dance Festival in 2008 from choreographer Liz Roche. Touring widely since its creation, it continues to be a rich research environment for the interrogation by Jenny Roche of the dancer’s first-person perspective in choreographic production and performance. The research perspective drawn from the live performance of this iteration was how the exploration of the same dancing moment might be expressed from multiple perspectives by three different dancers and what this might reveal about the dancer’s inner configuring of the performance environment. Erin Manning (2009) describes the unstable and emergent moment before movement materialises as the preacceleration of the movement, when the potentialities of the gesture collapse and stabilize into form. It is this threshold of potentiality that is interesting, the moment before the dance happens when the configuring process of the dancer brings it into being. Cynthia Roses Thema (2007), after neuroscientist Antonio Damasio, writes that embodied experience is mapped as it unfolds and alters from moment to moment in line with a constantly changing internal milieu. As a performer in this piece, I explored the inner terrain of the three performers (myself included) by externalizing these inner states. This research contributed to a paper presentation at the Digital Resources for the Arts and Humanities Conference, UK 2013.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Reliability of carrier phase ambiguity resolution (AR) of an integer least-squares (ILS) problem depends on ambiguity success rate (ASR), which in practice can be well approximated by the success probability of integer bootstrapping solutions. With the current GPS constellation, sufficiently high ASR of geometry-based model can only be achievable at certain percentage of time. As a result, high reliability of AR cannot be assured by the single constellation. In the event of dual constellations system (DCS), for example, GPS and Beidou, which provide more satellites in view, users can expect significant performance benefits such as AR reliability and high precision positioning solutions. Simply using all the satellites in view for AR and positioning is a straightforward solution, but does not necessarily lead to high reliability as it is hoped. The paper presents an alternative approach that selects a subset of the visible satellites to achieve a higher reliability performance of the AR solutions in a multi-GNSS environment, instead of using all the satellites. Traditionally, satellite selection algorithms are mostly based on the position dilution of precision (PDOP) in order to meet accuracy requirements. In this contribution, some reliability criteria are introduced for GNSS satellite selection, and a novel satellite selection algorithm for reliable ambiguity resolution (SARA) is developed. The SARA algorithm allows receivers to select a subset of satellites for achieving high ASR such as above 0.99. Numerical results from a simulated dual constellation cases show that with the SARA procedure, the percentages of ASR values in excess of 0.99 and the percentages of ratio-test values passing the threshold 3 are both higher than those directly using all satellites in view, particularly in the case of dual-constellation, the percentages of ASRs (>0.99) and ratio-test values (>3) could be as high as 98.0 and 98.5 % respectively, compared to 18.1 and 25.0 % without satellite selection process. It is also worth noting that the implementation of SARA is simple and the computation time is low, which can be applied in most real-time data processing applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We construct two efficient Identity-Based Encryption (IBE) systems that admit selective-identity security reductions without random oracles in groups equipped with a bilinear map. Selective-identity secure IBE is a slightly weaker security model than the standard security model for IBE. In this model the adversary must commit ahead of time to the identity that it intends to attack, whereas in an adaptive-identity attack the adversary is allowed to choose this identity adaptively. Our first system—BB1—is based on the well studied decisional bilinear Diffie–Hellman assumption, and extends naturally to systems with hierarchical identities, or HIBE. Our second system—BB2—is based on a stronger assumption which we call the Bilinear Diffie–Hellman Inversion assumption and provides another approach to building IBE systems. Our first system, BB1, is very versatile and well suited for practical applications: the basic hierarchical construction can be efficiently secured against chosen-ciphertext attacks, and further extended to support efficient non-interactive threshold decryption, among others, all without using random oracles. Both systems, BB1 and BB2, can be modified generically to provide “full” IBE security (i.e., against adaptive-identity attacks), either using random oracles, or in the standard model at the expense of a non-polynomial but easy-to-compensate security reduction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Breast cancer is the cancer that most commonly affects women worldwide. This type of cancer is genetically complex, but is strongly linked to steroid hormone signalling systems. Because microRNAs act as translational regulators of multiple genes, including the steroid nuclear receptors, single nucleotide polymorphisms (SNPs) in microRNAs genes can have potentially wide-ranging influences on breast cancer development. Thus, this study was conducted to investigate the relationships between six SNPs (rs6977848, rs199981120, rs185641358, rs113054794, rs66461782, and rs12940701) located in four miRNA genes predicted to target the estrogen receptor (miR-148a, miR-221, miR-186, and miR-152) and breast cancer risk in Caucasian Australian women. By using high resolution melt analysis (HRM) and polymerase chain reaction- restriction fragment length polymorphism (PCR-RFLP), 487 samples including 225 controls and 262 cases were genotyped. Analysis of their genotype and allele frequencies indicated that the differences between case and control populations was not significant for rs6977848, rs66461782, and rs12940701 because their p-values are 0.81, 0.93, 0.1 which are all above the threshold value (p=0.05). Our data thus suggests that these SNPs do not affect breast cancer risk in the tested population. In addition, rs199981120, rs185641358, and rs113054794 could not be found in this population, suggesting that these SNPs do not occur in Caucasian Australians.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recently, a convex hull-based human identification protocol was proposed by Sobrado and Birget, whose steps can be performed by humans without additional aid. The main part of the protocol involves the user mentally forming a convex hull of secret icons in a set of graphical icons and then clicking randomly within this convex hull. While some rudimentary security issues of this protocol have been discussed, a comprehensive security analysis has been lacking. In this paper, we analyze the security of this convex hull-based protocol. In particular, we show two probabilistic attacks that reveal the user’s secret after the observation of only a handful of authentication sessions. These attacks can be efficiently implemented as their time and space complexities are considerably less than brute force attack. We show that while the first attack can be mitigated through appropriately chosen values of system parameters, the second attack succeeds with a non-negligible probability even with large system parameter values that cross the threshold of usability.