937 resultados para TO-USE SYSTEMS
Resumo:
Introduction: Vertebral fracture is one of the major osteoporotic fractures which are unfortunately very often undetected. In addition, it is well known that prevalent vertebral fracture increases dramatically the risk of future additional fracture. Instant Vertebral Assessment (IVA) has been introduced in DXA device couple years ago to ease the detection of such fracture when routine DXA are performed. To correctly use such tool, ISCD provided clinical recommendation on when and how to use it. The aim of our study was to evaluate the ISCD guidelines in clinical routine patients and see how often it may change of patient management. Methods: During two months (March and April 2010), a medical questionnaire was systematically given to our clinical routine patient to check the validity of ISCD IVA recommendations in our population. In addition, all women had BMD measurement at AP spine, Femur and 1/3 radius using a Discovery A System (Hologic, Waltham, USA). When appropriate, IVA measurement had been performed on the same DXA system and had been centrally evaluated by two trained Doctors for fracture status according to the semi-quantitative method of Genant. The reading had been performed when possible between L5 and T4. Results: Out of 210 women seen in the consultation, 109 (52%) of them (mean age 68.2 ± 11.5 years) fulfilled the necessary criteria to have an IVA measurement. Out of these 109 women, 43 (incidence 39.4%) had osteoporosis at one of the three skeletal sites and 31 (incidence 28.4%) had at least one vertebral fracture. 14.7% of women had both osteoporosis and at least one vertebral fracture classifying them as "severe osteoporosis" while 46.8% did not have osteoporosis nor vertebral fracture. 24.8% of the women had osteoporosis but no vertebral fracture while 13.8% of women did have osteoporosis and vertebral fracture (clinical osteoporosis). Conclusion: In conclusion, in 52% of our patients, IVA was needed according to ISCD criteria. In half of them the IVA test influenced of patient management either by changing the type of treatment of simply by classifying patient as "clinical osteoporosis". IVA appears to be an important tool in clinical routine but unfortunately is not yet very often used in most of the centers.
Resumo:
La mayor parte de las nuevas infecciones con el VIH en el mundo se producen por transmisión sexual entre adultos jóvenes y se aprecia una mayor vulnerabilidad en las mujeres (Gregson et al., 2002). Los principales objetivos de este trabajo son: estudiar la prevalencia del uso auto informado del preservativo durante la última relación sexual en los estudiantes de secundaria de Mozambique y la intención de emplearlo en las futuras relaciones, sea con la pareja actual o con una ocasional. Los resultados muestran que: 1) el 47% de los va rones y el 62% de las mujeres no utilizaron el preservativo, 2) tanto ellos como ellas están más seguros de que lo utilizarán con una pareja ocasional que con la actual y 3) los que emplearon el preservativo en su última relación sexual tienen más intención de volver a usarlo que aquellos que no lo emplearon
Resumo:
Research carried out in several Anglo-Saxon countries shows that many undergraduatesidentify oral sex and anal sex as examples of abstinent behaviour, while manyothers consider kissing and masturbation as examples of having sex. The objective ofthis research was to investigate whether a sample of Spanish students gave similarreplies. Seven hundred and fifty undergraduates (92% aged under 26, 67.6%women) produced examples or definitions of the term ‘abstinence’. Spanish studentsmade similar errors to those observed in the Anglo-Saxon samples, in thatbehaviours that were abstinent from a preventive point of view (masturbating andsex without penetration) were not considered as such, while a number of studentsreported oral sex as abstinent behaviour. The results suggest that the information onrisky and preventive sexual behaviour should cease to use ambiguous or euphemisticexpressions and use vocabulary that is clear and comprehensible to everyone
Resumo:
Compositional random vectors are fundamental tools in the Bayesian analysis of categorical data.Many of the issues that are discussed with reference to the statistical analysis of compositionaldata have a natural counterpart in the construction of a Bayesian statistical model for categoricaldata.This note builds on the idea of cross-fertilization of the two areas recommended by Aitchison (1986)in his seminal book on compositional data. Particular emphasis is put on the problem of whatparameterization to use
Resumo:
Reinforcement learning (RL) is a very suitable technique for robot learning, as it can learn in unknown environments and in real-time computation. The main difficulties in adapting classic RL algorithms to robotic systems are the generalization problem and the correct observation of the Markovian state. This paper attempts to solve the generalization problem by proposing the semi-online neural-Q_learning algorithm (SONQL). The algorithm uses the classic Q_learning technique with two modifications. First, a neural network (NN) approximates the Q_function allowing the use of continuous states and actions. Second, a database of the most representative learning samples accelerates and stabilizes the convergence. The term semi-online is referred to the fact that the algorithm uses the current but also past learning samples. However, the algorithm is able to learn in real-time while the robot is interacting with the environment. The paper shows simulated results with the "mountain-car" benchmark and, also, real results with an underwater robot in a target following behavior
Resumo:
Vertebral fracture is one of the major osteoporotic fractures which are unfortunately very often undetected. In addition, it is well known that prevalent vertebral fracture increases dramatically the risk of future additional fracture. Instant Vertebral Assessment (IVA) has been introduced in DXA device couple years ago to ease the detection of such fracture when routine DXA are performed. To correctly use such tool, ISCD provided clinical recommendation on when and how to use it. The aim of our study was to evaluate the ISCD guidelines in clinical routine patients and see how often it may change of patient management. During two months (March and April 2010), a medical questionnaire was systematically given to our clinical routine patient to check the validity of ISCD IVA recommendations in our population. In addition, all women had BMD measurement at AP spine, Femur and 1/3 radius using a Discovery A System (Hologic, Waltham, USA). When appropriate, IVA measurement had been performed on the same DXA system and had been centrally evaluated by two trained Doctors for fracture status according to the semi-quantitative method of Genant. The reading had been performed when possible between L5 and T4. Out of 210 women seen in the consultation, 109 (52%) of them (mean age 68.2±11.5 years) fulfilled the necessary criteria to have an IVA measurement. Out of these 109 women, 43 (incidence 39.4%) had osteoporosis at one of the three skeletal sites and 31 (incidence 28.4%) had at least one vertebral fracture. 14.7% of women had both osteoporosis and at least one vertebral fracture classifying them as "severe osteoporosis" while 46.8% did not have osteoporosis not vertebral fracture. 24.8% of the women had osteoporosis but no vertebral fracture while 13.8% of women did have osteoporosis but vertebral fracture (Clinical osteoporosis). In conclusion, in 52% of our patients, IVA was needed according to ISCD criteria. In half of them the IVA test influenced of patient management either my changing the type of treatment of simply by classifying patient as "clinical osteoporosis". IVA appears to be an important tool in clinical routine but unfortunately is not yet very often use in most of the centers.
Resumo:
Nanotechnologists have become involved in regenerative medicine via creation of biomaterials and nanostructures with potential clinical implications. Their aim is to develop systems that can mimic, reinforce or even create in vivo tissue repair strategies. In fact, in the last decade, important advances in the field of tissue engineering, cell therapy and cell delivery have already been achieved. In this review, we will delve into the latest research advances and discuss whether cell and/or tissue repair devices are a possibility. Focusing on the application of nanotechnology in tissue engineering research, this review highlights recent advances in the application of nano-engineered scaffolds designed to replace or restore the followed tissues: (i) skin; (ii) cartilage; (iii) bone; (iv) nerve; and (v) cardiac.
Resumo:
Introduction To guarantee the success of a virtual library it is essential that all users can access all the library resources independently of the user’s location. Achieving this goal in the Andalusian Public Health System has been a particularly difficult task, due to it is made up of 10 research centers and 95.000 health-care professionals. Aims Since the BV-SSPA started three years ago, one of its mayor aims has been to provide remote access to all its resources in this complex scenario, as well as facilitate the access to the virtual library to both professionals and citizens. IP access was guaranteed because health-care professionals could access everything from their workplaces thanks to the intranet, but it was restricted when they were not there. The BV-SSPA solved this problem by installing a federated authentication and authorization system called PAPI and a PAPI rewriting proxy. After three years the BV-SSPA has met a new challenge: adapting its federated access system to Metalib and SFX, specifically the access management module PDS had to be connected with the existing PAPI system. This new challenge came along with the introduction of a new metasearcher and link resolver. Material and Methods Initially there were three independent systems: • A Metalib and SFX PDS module, • A federated authentication and authorization system: PAPI. • A PAPI Rewriting Proxy. The chosen solution went through the reutilization of the existing software. To achieve this goal, a PHP connector between these applications was developed and several modules in the PDS configuration were modified. On the other hand, providing a simplified access to Metalib has been solved using Xerxes and integrating it in a Drupal website. Results Thanks to this connector the BV-SSPA was able to get all its users remotely accessing its new metasearcher without changing the way they used to validate, or without having to remember a new username and password. Futhermore, thanks to Xerxes, it is possible to use Metalib from a simple interface and without having to leave the BV-SSPA website to go its native interface.
Resumo:
Pyocins are toxic proteins produced by some strains of Pseudomonas aeruginosa that are lethal for related strains of the same species. Some soluble pyocins (S2, S3 and S4) were previously shown to use the pyoverdine siderophore receptors to enter the cell. The P. aeruginosa PAO1 pore-forming pyocin S5 encoding gene (PAO985) was cloned into the expression vector pET15b, and the affinity-purified protein product tested for its killing activity against different P. aeruginosa strains. The results, however, did not show any correlation with a specific ferripyoverdine receptor. To further identify the S5 receptor, transposon mutants were generated. Pooled mutants were exposed to pyocin S5 and the resistant colonies growing in the killing zone were selected. The majority of S5-resistant mutants had an insertion in the fptA gene encoding the receptor for the siderophore pyochelin. Complementation of an fptA transposon mutant with the P. aeruginosa fptA gene in trans restored the sensitivity to S5. In order to define the receptor-binding domain of pyocin S5, two hybrid pyocins were constructed containing different regions from pyocin S5 fused to the C-terminal translocation and DNase killing domains of pyocin S2. Only the protein containing amino acid residues 151 to 300 from S5 showed toxicity, indicating that the pyocin S5 receptor-binding domain is not at the N-terminus of the protein as in other S-type pyocins. Pyocin S5 was, however, unable to kill Burkholderia cenocepacia strains producing a ferripyochelin FptA receptor, nor was the B. cenocepacia fptA gene able to restore the sensitivity of the resistant fptA mutant P. aeruginosa strain.
Resumo:
Purpose: To develop and evaluate a practical method for the quantification of signal-to-noise ratio (SNR) on coronary MR angiograms (MRA) acquired with parallel imaging.Materials and Methods: To quantify the spatially varying noise due to parallel imaging reconstruction, a new method has been implemented incorporating image data acquisition followed by a fast noise scan during which radio-frequency pulses, cardiac triggering and navigator gating are disabled. The performance of this method was evaluated in a phantom study where SNR measurements were compared with those of a reference standard (multiple repetitions). Subsequently, SNR of myocardium and posterior skeletal muscle was determined on in vivo human coronary MRA.Results: In a phantom, the SNR measured using the proposed method deviated less than 10.1% from the reference method for small geometry factors (<= 2). In vivo, the noise scan for a 10 min coronary MRA acquisition was acquired in 30 s. Higher signal and lower SNR, due to spatially varying noise, were found in myocardium compared with posterior skeletal muscle.Conclusion: SNR quantification based on a fast noise scan is a validated and easy-to-use method when applied to three-dimensional coronary MRA obtained with parallel imaging as long as the geometry factor remains low.
Resumo:
As stated in Aitchison (1986), a proper study of relative variation in a compositional data set should be based on logratios, and dealing with logratios excludes dealing with zeros. Nevertheless, it is clear that zero observations might be present in real data sets, either because the corresponding part is completelyabsent –essential zeros– or because it is below detection limit –rounded zeros. Because the second kind of zeros is usually understood as “a trace too small to measure”, it seems reasonable to replace them by a suitable small value, and this has been the traditional approach. As stated, e.g. by Tauber (1999) and byMartín-Fernández, Barceló-Vidal, and Pawlowsky-Glahn (2000), the principal problem in compositional data analysis is related to rounded zeros. One should be careful to use a replacement strategy that does not seriously distort the general structure of the data. In particular, the covariance structure of the involvedparts –and thus the metric properties– should be preserved, as otherwise further analysis on subpopulations could be misleading. Following this point of view, a non-parametric imputation method isintroduced in Martín-Fernández, Barceló-Vidal, and Pawlowsky-Glahn (2000). This method is analyzed in depth by Martín-Fernández, Barceló-Vidal, and Pawlowsky-Glahn (2003) where it is shown that thetheoretical drawbacks of the additive zero replacement method proposed in Aitchison (1986) can be overcome using a new multiplicative approach on the non-zero parts of a composition. The new approachhas reasonable properties from a compositional point of view. In particular, it is “natural” in the sense thatit recovers the “true” composition if replacement values are identical to the missing values, and it is coherent with the basic operations on the simplex. This coherence implies that the covariance structure of subcompositions with no zeros is preserved. As a generalization of the multiplicative replacement, in thesame paper a substitution method for missing values on compositional data sets is introduced
Resumo:
This paper focuses on one of the methods for bandwidth allocation in an ATM network: the convolution approach. The convolution approach permits an accurate study of the system load in statistical terms by accumulated calculations, since probabilistic results of the bandwidth allocation can be obtained. Nevertheless, the convolution approach has a high cost in terms of calculation and storage requirements. This aspect makes real-time calculations difficult, so many authors do not consider this approach. With the aim of reducing the cost we propose to use the multinomial distribution function: the enhanced convolution approach (ECA). This permits direct computation of the associated probabilities of the instantaneous bandwidth requirements and makes a simple deconvolution process possible. The ECA is used in connection acceptance control, and some results are presented
Resumo:
Introduction Vertebral fracture is one of the major osteoporoticfractures which are unfortunately very often undetected. In addition,it is well known that prevalent vertebral fracture increases dramaticallythe risk of future additional fracture. Instant Vertebral Assessment(IVA) has been introduced in DXA device a couple of years ago toease the detection of such fracture when routine DXA are performed.To correctly use such tool, ISCD provided clinical recommendationon when and how to use it. The aim of our study was to evaluate theISCD guidelines in clinical routine patients and see how often itmay change of patient management.Methods During two months (March and April 2010), a medicalquestionnaire was systematically given to our clinical routine patientto check the validity of ISCD IVA recommendations in our population.In addition, all women had BMD measurement at AP spine,femur and 1/3 radius using a Discovery A System (Hologic, Waltham,USA). When appropriate, IVA measurement had been performedon the same DXA system and had been centrally evaluated by twotrained doctors for fracture status according to the semi-quantitativemethod of Genant. The reading had been performed when possiblebetween L5 and T4.Results Out of 210 women seen in the consultation, 109 (52 %)of them (mean age 68.2 ± 11.5 years) fulfilled the necessary criteriato have an IVA measurement. Out of these 109 women, 43 (incidence39.4 %) had osteoporosis at one of the three skeletal sitesand 31 (incidence 28.4 %) had at least one vertebral fracture. 14.7 %of women had both osteoporosis and at least one vertebral fractureclassifying them as "severe osteoporosis" while 46.8 % did not haveosteoporosis and no vertebral fracture. 24.8 % of the women hadosteoporosis but no vertebral fracture while 13.8 % of women didhave osteoporosis but vertebral fracture (clinical osteoporosis).Conclusions In 52 % of our patients, IVA was needed accordingto ISCD criteria. In half of them the IVA test influenced of patientmanagement either may changing the type of treatment of simplyby classifying patient as "clinical osteoporosis". IVA appears to bean important tool in clinical routine but unfortunately is not yetvery often use in most of the centers.
Resumo:
La tomodensitométrie (CT) est une technique d'imagerie dont l'intérêt n'a cessé de croître depuis son apparition dans le début des années 70. Dans le domaine médical, son utilisation est incontournable à tel point que ce système d'imagerie pourrait être amené à devenir victime de son succès si son impact au niveau de l'exposition de la population ne fait pas l'objet d'une attention particulière. Bien évidemment, l'augmentation du nombre d'examens CT a permis d'améliorer la prise en charge des patients ou a rendu certaines procédures moins invasives. Toutefois, pour assurer que le compromis risque - bénéfice soit toujours en faveur du patient, il est nécessaire d'éviter de délivrer des doses non utiles au diagnostic.¦Si cette action est importante chez l'adulte elle doit être une priorité lorsque les examens se font chez l'enfant, en particulier lorsque l'on suit des pathologies qui nécessitent plusieurs examens CT au cours de la vie du patient. En effet, les enfants et jeunes adultes sont plus radiosensibles. De plus, leur espérance de vie étant supérieure à celle de l'adulte, ils présentent un risque accru de développer un cancer radio-induit dont la phase de latence peut être supérieure à vingt ans. Partant du principe que chaque examen radiologique est justifié, il devient dès lors nécessaire d'optimiser les protocoles d'acquisitions pour s'assurer que le patient ne soit pas irradié inutilement. L'avancée technologique au niveau du CT est très rapide et depuis 2009, de nouvelles techniques de reconstructions d'images, dites itératives, ont été introduites afin de réduire la dose et améliorer la qualité d'image.¦Le présent travail a pour objectif de déterminer le potentiel des reconstructions itératives statistiques pour réduire au minimum les doses délivrées lors d'examens CT chez l'enfant et le jeune adulte tout en conservant une qualité d'image permettant le diagnostic, ceci afin de proposer des protocoles optimisés.¦L'optimisation d'un protocole d'examen CT nécessite de pouvoir évaluer la dose délivrée et la qualité d'image utile au diagnostic. Alors que la dose est estimée au moyen d'indices CT (CTDIV0| et DLP), ce travail a la particularité d'utiliser deux approches radicalement différentes pour évaluer la qualité d'image. La première approche dite « physique », se base sur le calcul de métriques physiques (SD, MTF, NPS, etc.) mesurées dans des conditions bien définies, le plus souvent sur fantômes. Bien que cette démarche soit limitée car elle n'intègre pas la perception des radiologues, elle permet de caractériser de manière rapide et simple certaines propriétés d'une image. La seconde approche, dite « clinique », est basée sur l'évaluation de structures anatomiques (critères diagnostiques) présentes sur les images de patients. Des radiologues, impliqués dans l'étape d'évaluation, doivent qualifier la qualité des structures d'un point de vue diagnostique en utilisant une échelle de notation simple. Cette approche, lourde à mettre en place, a l'avantage d'être proche du travail du radiologue et peut être considérée comme méthode de référence.¦Parmi les principaux résultats de ce travail, il a été montré que les algorithmes itératifs statistiques étudiés en clinique (ASIR?, VEO?) ont un important potentiel pour réduire la dose au CT (jusqu'à-90%). Cependant, par leur fonctionnement, ils modifient l'apparence de l'image en entraînant un changement de texture qui pourrait affecter la qualité du diagnostic. En comparant les résultats fournis par les approches « clinique » et « physique », il a été montré que ce changement de texture se traduit par une modification du spectre fréquentiel du bruit dont l'analyse permet d'anticiper ou d'éviter une perte diagnostique. Ce travail montre également que l'intégration de ces nouvelles techniques de reconstruction en clinique ne peut se faire de manière simple sur la base de protocoles utilisant des reconstructions classiques. Les conclusions de ce travail ainsi que les outils développés pourront également guider de futures études dans le domaine de la qualité d'image, comme par exemple, l'analyse de textures ou la modélisation d'observateurs pour le CT.¦-¦Computed tomography (CT) is an imaging technique in which interest has been growing since it first began to be used in the early 1970s. In the clinical environment, this imaging system has emerged as the gold standard modality because of its high sensitivity in producing accurate diagnostic images. However, even if a direct benefit to patient healthcare is attributed to CT, the dramatic increase of the number of CT examinations performed has raised concerns about the potential negative effects of ionizing radiation on the population. To insure a benefit - risk that works in favor of a patient, it is important to balance image quality and dose in order to avoid unnecessary patient exposure.¦If this balance is important for adults, it should be an absolute priority for children undergoing CT examinations, especially for patients suffering from diseases requiring several follow-up examinations over the patient's lifetime. Indeed, children and young adults are more sensitive to ionizing radiation and have an extended life span in comparison to adults. For this population, the risk of developing cancer, whose latency period exceeds 20 years, is significantly higher than for adults. Assuming that each patient examination is justified, it then becomes a priority to optimize CT acquisition protocols in order to minimize the delivered dose to the patient. Over the past few years, CT advances have been developing at a rapid pace. Since 2009, new iterative image reconstruction techniques, called statistical iterative reconstructions, have been introduced in order to decrease patient exposure and improve image quality.¦The goal of the present work was to determine the potential of statistical iterative reconstructions to reduce dose as much as possible without compromising image quality and maintain diagnosis of children and young adult examinations.¦The optimization step requires the evaluation of the delivered dose and image quality useful to perform diagnosis. While the dose is estimated using CT indices (CTDIV0| and DLP), the particularity of this research was to use two radically different approaches to evaluate image quality. The first approach, called the "physical approach", computed physical metrics (SD, MTF, NPS, etc.) measured on phantoms in well-known conditions. Although this technique has some limitations because it does not take radiologist perspective into account, it enables the physical characterization of image properties in a simple and timely way. The second approach, called the "clinical approach", was based on the evaluation of anatomical structures (diagnostic criteria) present on patient images. Radiologists, involved in the assessment step, were asked to score image quality of structures for diagnostic purposes using a simple rating scale. This approach is relatively complicated to implement and also time-consuming. Nevertheless, it has the advantage of being very close to the practice of radiologists and is considered as a reference method.¦Primarily, this work revealed that the statistical iterative reconstructions studied in clinic (ASIR? and VECO have a strong potential to reduce CT dose (up to -90%). However, by their mechanisms, they lead to a modification of the image appearance with a change in image texture which may then effect the quality of the diagnosis. By comparing the results of the "clinical" and "physical" approach, it was showed that a change in texture is related to a modification of the noise spectrum bandwidth. The NPS analysis makes possible to anticipate or avoid a decrease in image quality. This project demonstrated that integrating these new statistical iterative reconstruction techniques can be complex and cannot be made on the basis of protocols using conventional reconstructions. The conclusions of this work and the image quality tools developed will be able to guide future studies in the field of image quality as texture analysis or model observers dedicated to CT.
Resumo:
This paper studies whether firms' use of R&D subsidies and R&D tax incentives is correlated to two sources of underinvestment in R&D, financing constraints and appropriability. We find that financially constrained SMEs are less likely to use R&D tax credits and more likely to obtain subsidies. SMEs using legal methods to protect their intellectual property are more likely to use tax incentives. Results are ambiguous for large firms. For both having previous experience in R&D increases the likelihood of using tax incentives, while it reduces the likelihood of using exclusively subsidies, suggesting that the latter induce entry into R&D. Results imply that direct funding and tax credits do not have the same ability to address each source of R&D underinvestment, and that on average subsidies may be better suited than tax credits at least for SMEs. From a policy perspective these tools may be complements rather than substitutes.