965 resultados para Spira, Francesco, -1548.
Resumo:
The aim of this study was to evaluate the diagnostic agreement of conventional panoramic radiographs and their inverted scanned images in the detection of the mandibular canal and mental foramen. A total of 77 panoramic radiographs obtained from the files of totally edentulous patients were used. Digitization was done by means of a scanner with brightness and contrast adjustment, as well as image inversion. The extension of mandibular canal was divided into anterior, middle, and posterior regions, and the presence of a radiopaque line that characterized the mandibular canal was classified according to a 5-point confidence scale. The mental foramen was classified in 4 types: continuous, separated, diffuse, and unidentified. Both conventional and inverted scanned panoramic radiographs were evaluated by 3 calibrated implantologists at 2 distinct moments with a minimum interval of 10 days between them. Intraexaminer agreement was evaluated by Kappa statistics by point and by 95% confidence interval. Because the intraexaminer level of agreement was low, interexaminer agreements could not be carried out. The results showed a substantial (in 2 situations), moderate (in 16 situations), and fair (in 18 situations) intraexaminer agreement for mandibular canal and a substantial (in 1 situation), fair (in 1 situation), and moderate (in 10 situations) intraeaminer agreement for mental foramen. There were no statistically significant differences in most instances. In conclusion, the diagnostic agreement of conventional and inverted scanned panoramic radiographs for detection of mandibular canal and mental foramen was low.
Resumo:
The purpose of this study was to investigate the penetration of an aggressive self-etching adhesive system at refrigerated and room temperatures into ground and unground enamel surfaces. Thirty extracted human teeth were used to measure adhesive penetration into enamel by light microscopy analysis (x400). The unground enamel surfaces were cleaned with pumice and water using a rotary dental brush. For each specimen, part of the unground enamel was manually ground and part was kept intact. A self-etch adhesive was evaluated for its ability to penetrate ground and unground enamel surfaces at room temperature (25 degrees C), at 30 minutes after removal from the refrigerator, and immediately after removal from the refrigerator (6 degrees C). Data were analyzed using variance and the Tukey test, which revealed significant differences in length of penetration of this material when applied on ground and unground enamel surfaces and between the different temperatures used (P > .05). The self-etching system used in this study had significantly lower penetration into unground enamel and at 6 degrees C (P < .05). No statistical difference was found between the interactions of these factors. It was concluded that the self-etching system produced the best penetration into ground enamel surface at room temperature (25 degrees C) and at 30 minutes after removing the specimens from the refrigerator.
Resumo:
There are several papers on pruning methods in the artificial neural networks area. However, with rare exceptions, none of them presents an appropriate statistical evaluation of such methods. In this article, we proved statistically the ability of some methods to reduce the number of neurons of the hidden layer of a multilayer perceptron neural network (MLP), and to maintain the same landing of classification error of the initial net. They are evaluated seven pruning methods. The experimental investigation was accomplished on five groups of generated data and in two groups of real data. Three variables were accompanied in the study: apparent classification error rate in the test group (REA); number of hidden neurons, obtained after the application of the pruning method; and number of training/retraining epochs, to evaluate the computational effort. The non-parametric Friedman's test was used to do the statistical analysis.
Resumo:
The aim of this study is to survey radiographic measurement estimation in the assessment of dental implant length according to dentists' confidence. A 19-point questionnaire with closed-ended questions was used by two graduate students to interview 69 dentists during a dental implant meeting. Included were 12 questions related to over- and underestimation in three radiographic modalities: panoramic (P), conventional tomography (T), and computerized tomography (CT). The database was analyzed by Epi-Info 6.04 software and the values from two radiographic modalities, P and T, were compared using a chi2 test. The results showed that 38.24% of the dentists' confidence was in the overestimation of measurements in P, 30.56% in T, and 0% in CT. On the other hand, considering the underestimated measurements, the percentages were 47.06% in P, 33.33% in T, and 1.92% in CT. The frequency of under- and overestimation were statistically significant (chi2 = 6.32; P = .0425) between P and T. CT was the radiographic modality with higher measurement precision according to dentists' confidence. In conclusion, the interviewed dentists felt that CT was the best radiographic modality when considering the measurement estimation precision in preoperative dental implant assessment.
Resumo:
The objective of this study was to describe a new platelet-rich plasma (PRP) protocol with a reduced concentration of leukocytes and intact platelets. We collected 8 mL of venous blood (VB) from marginal ear veins of 10 male New Zealand white rabbits in acid dextrose citrate Vacutainer tubes. Tubes were centrifuged at 302g for 10 minutes. All plasma was collected in plastic tubes to avoid buffy-coat contamination and centrifuged at 2862g for 5 minutes. A 10% calcium chloride activator (10 PRP:2 CaCl2) was added to the lower third of this plasma (PRP), and the PRP gel was obtained. Mean platelet count was 317.7 x 10(3) +/- 39.9/microL in VB and 1344.9 x 10(3) +/- 347.5/microL in PRP. Leukocyte counts were 3.96 x 10(3) +/- 2.01/microL and 0.46 x 10(3) +/- 0.45/microL in VB and PRP, respectively. Mean platelet enrichment was 327.4 +/- 97.8%. All differences were statistically significant (P > .05). This protocol is practical and reproducible, resulting in a high concentration of intact platelets to help tissue repair and low levels of leukocytes.
Resumo:
PURPOSE: To investigate the penetration (tags) of adhesive materials into enamel etched with phosphoric acid or treated with a self-etching adhesive, before application of a pit-and-fissure sealant. MATERIALS AND METHODS: The sample comprised six study groups with six specimens each. Before pit-and-fissure sealing with the materials Clinpro SealantTM (Groups I and II), Vitro Seal ALPHA (Groups III and IV) and Fuji II LC (Groups V and VI), the teeth in Groups I, III, and V were etched with 35% phosphoric acid for 30 seconds. Teeth in Groups II, IV, and VI received application of the self-etching adhesive Adper Prompt L-Pop. The treated teeth were sectioned buccolingually, ground to 100-microm thickness, decalcified, and analyzed by conventional light microscopy at 400x magnification. RESULTS: The teeth etched with phosphoric acid exhibited significantly greater penetration than specimens treated with self-etching adhesive. CLINICAL SIGNIFICANCE: When compared with enamel treated with a self-etching adhesive, the penetration (tags) of adhesive materials into enamel was greater when applied on enamel etched with phosphoric acid.
Resumo:
This paper discusses the importance of the voltage referential for power quality monitoring and power systempsilas instrumentation. Considering the operating conditions of simple power circuits, it will be demonstrated that an incorrect choice of the voltages referential may result in erroneous quantification of some power quality indices, especially in three-phase four wire circuits. The use of a virtual reference point and the neutral conductor as reference have been considered and the simulation results confirm the influence of the voltage reference selection in the evaluation of total harmonic distortion, unbalance factors and voltage sags. Finally a way of linking both methods will be discussed by means of Blakesleypsilas theorem. © Copyright 2010 IEEE - All Rights Reserved.
Resumo:
ResumoThe main idea of this work is based on the analysis of the electric torque through the acting of the PS in the power system, provided of a control for the compensation degree (PSC). A linear model of the single machine-infinite bus system is used with a PS installed (SMIB/PS system). The variable that represents the presence of PS in the net is associated to the phase displacement introduced in the terminal voltage of the synchronous machine by PS. For the input signals of the PSC are evaluated variations of the angular speed of the rotor, the current magnitude and the active power through the line where the PS is located. The simulations are accomplished to analyze the influence of the PS in the torque formation (synchronizing and damping), of the SMIB/PS system. The analysis are developed in the time and frequency domain.
Resumo:
Incluye Bibliografía
Resumo:
In recent years, antiphospholipid syndrome (APS) has been increasingly recognised in various paediatric autoimmune and nonautoimmune diseases, but the relatively low prevalence and heterogeneity of APS in childhood made it very difficult to study in a systematic way. The project of an international registry of paediatric patients with APS (the Ped-APS Registry) was initiated in 2004 to foster and conduct multicentre, controlled studies with large number of paediatric APS patients. The Ped-APS Registry is organised as a collaborative project of the European Forum on Antiphospholipid Antibodies and Juvenile Systemic Lupus Erythematosus Working Group of the Paediatric Rheumatology European Society. Currently, it documents a standardised clinical, laboratory and therapeutic data of 133 children with antiphospholipid antibodies (aPL)-related thrombosis from 14 countries. The priority projects for future research of the Ped-APS Registry include prospective enrolment of new patients with aPL-related thrombosis, assessment of differences between the paediatric and adult APS, evaluation of proinflammatory genotype as a risk factor for APS manifestations in childhood and evaluation of patients with isolated nonthrombotic aPL-related manifestations. © The Author(s), 2009.
Resumo:
In this work, a heuristic model for integrated planning of primary distribution network and secondary distribution circuits is proposed. A Tabu Search (TS) algorithm is employed to solve the planning of primary distribution networks. Evolutionary Algorithms (EA) are used to solve the planning model of secondary networks. The planning integration of both networks is carried out by means a constructive heuristic taking into account a set of integration alternatives between these networks. These integration alternatives are treated in a hierarchical way. The planning of primary networks and secondary distribution circuits is carried out based on assessment of the effects of the alternative solutions in the expansion costs of both networks simultaneously. In order to evaluate this methodology, tests were performed for a real-life distribution system taking into account the primary and secondary networks.
Resumo:
Abarca toda la producción bibliográfica de CEPAL, ILPES y CELADE desde 1948 a 1987, excluidos solamente los temarios de reunión, listas de documentos e informes de carácter administrativo e institucional.
Resumo:
In this paper, we propose new circuits for the implementation of Radial Basis Functions (RBF). These RBFs are obtained by the subtraction of two differential pair output currents in a folded cascode configuration. We also propose a multidimensional version based on the unidimensional circuits. SPICE simulation and experimental results indicate good functionality. These circuits are intended to be applied in the implementation of radial basis function networks. Possible applications of these networks include transducer signal conditioning and processing in onboard telemetry systems for aircraft and spacecraft vehicles. © 2010 IEEE.