970 resultados para Ship handling
Resumo:
Distributed generation unlike centralized electrical generation aims to generate electrical energy on small scale as near as possible to load centers, interchanging electric power with the network. This work presents a probabilistic methodology conceived to assist the electric system planning engineers in the selection of the distributed generation location, taking into account the hourly load changes or the daily load cycle. The hourly load centers, for each of the different hourly load scenarios, are calculated deterministically. These location points, properly weighted according to their load magnitude, are used to calculate the best fit probability distribution. This distribution is used to determine the maximum likelihood perimeter of the area where each source distributed generation point should preferably be located by the planning engineers. This takes into account, for example, the availability and the cost of the land lots, which are factors of special relevance in urban areas, as well as several obstacles important for the final selection of the candidates of the distributed generation points. The proposed methodology has been applied to a real case, assuming three different bivariate probability distributions: the Gaussian distribution, a bivariate version of Freund’s exponential distribution and the Weibull probability distribution. The methodology algorithm has been programmed in MATLAB. Results are presented and discussed for the application of the methodology to a realistic case and demonstrate the ability of the proposed methodology for efficiently handling the determination of the best location of the distributed generation and their corresponding distribution networks.
Resumo:
This paper addresses the optimal involvement in derivatives electricity markets of a power producer to hedge against the pool price volatility. To achieve this aim, a swarm intelligence meta-heuristic optimization technique for long-term risk management tool is proposed. This tool investigates the long-term opportunities for risk hedging available for electric power producers through the use of contracts with physical (spot and forward contracts) and financial (options contracts) settlement. The producer risk preference is formulated as a utility function (U) expressing the trade-off between the expectation and the variance of the return. Variance of return and the expectation are based on a forecasted scenario interval determined by a long-term price range forecasting model. This model also makes use of particle swarm optimization (PSO) to find the best parameters allow to achieve better forecasting results. On the other hand, the price estimation depends on load forecasting. This work also presents a regressive long-term load forecast model that make use of PSO to find the best parameters as well as in price estimation. The PSO technique performance has been evaluated by comparison with a Genetic Algorithm (GA) based approach. A case study is presented and the results are discussed taking into account the real price and load historical data from mainland Spanish electricity market demonstrating the effectiveness of the methodology handling this type of problems. Finally, conclusions are dully drawn.
Resumo:
Animal confinement tends to increase the overall microbial load in the production environment caused by high amounts of feed and organic residuals (manure and wastewater) present in those environments. The number of animais and the handling and management required to work in these settings also contribute to enhance that microbial ioad. Animal housing typically exposes workers to substantial concentrations of bioaerosols, such as fungi and their metabolites. Therefore, agricultural workers, and especially pig and poultry farmers, are at increased risk of occupational respiratory diseases. Exposure to bioaerosols in poultries and swines may vary depending upon the stage of the animals' growth, density, manure management procedures, litter type and used floor coverage, among others. Gathering temporal information about the quantity and the composition of fungal load is necessary to better understand the relationship between these factors and adverse health symptoms of workers. This study aimed to characterize and compare fungal contamination between these two different settings.
Resumo:
This paper presents the proposal of an architecture for developing systems that interact with Ambient Intelligence (AmI) environments. This architecture has been proposed as a consequence of a methodology for the inclusion of Artificial Intelligence in AmI environments (ISyRAmI - Intelligent Systems Research for Ambient Intelligence). The ISyRAmI architecture considers several modules. The first is related with the acquisition of data, information and even knowledge. This data/information knowledge deals with our AmI environment and can be acquired in different ways (from raw sensors, from the web, from experts). The second module is related with the storage, conversion, and handling of the data/information knowledge. It is understood that incorrectness, incompleteness, and uncertainty are present in the data/information/knowledge. The third module is related with the intelligent operation on the data/information/knowledge of our AmI environment. Here we include knowledge discovery systems, expert systems, planning, multi-agent systems, simulation, optimization, etc. The last module is related with the actuation in the AmI environment, by means of automation, robots, intelligent agents and users.
Resumo:
Sendo o manual escolar o recurso pedagógico mais utilizado por alunos e professores foi realizada uma investigação tendo por objectivo avaliar qualitativamente a forma comunicacional de um conjunto de manuais escolares do 2º ciclo do ensino básico1. A importância atribuída atualmente à imagem é patente nos manuais escolares, sob pretexto de se tornarem mais apelativos e mais eficazes. Tal como em outras áreas em que a quantidade de imagens acaba por se transformar em poluição visual porque o ser humano não tem capacidade para reagir, simultaneamente, a um demasiado número de estímulos, nas estratégias comunicacionais dos manuais escolares este problema deve ser acautelado porque delas depende a sua qualidade pedagógica. As investigações não comprovam que exista uma relação direta entre a presença de ilustrações num texto e o aumento da sua compreensão. Pelo contrário, há estudos que sugerem que muitas ilustrações falham como potenciadoras da aprendizagem. Neste sentido, da investigação referida, consta uma análise ao rácio imagem/texto e uma auscultação a dois grupos de amostra - professores e alunos – sobre alguns aspectos gerais relativos à presença e eficácia pedagógica das ilustrações dos manuais escolares. Destacamos que, no caso dos alunos, apesar do seu nível de literacia ter constituído um obstáculo ao tratamento das questões, optámos por apresentar as suas respostas.
Resumo:
Mestrado em Engenharia Electrotécnica e de Computadores
Resumo:
Bacterial food poisoning is an ever-present threat that can be prevented with proper care and handling of food products. A disposable electrochemical immunosensor for the simultaneous measurements of common food pathogenic bacteria namely Escherichia coli O157:H7 (E. coli), campylobacter and salmonella were developed. The immunosensor was fabricated by immobilizing the mixture of anti-E. coli, anticampylobacter and anti-salmonella antibodies with a ratio of 1:1:1 on the surface of the multiwall carbon nanotube-polyallylamine modified screen printed electrode (MWCNT-PAH/SPE). Bacteria suspension became attached to the immobilized antibodies when the immunosensor was incubated in liquid samples. The sandwich immunoassay was performed with three antibodies conjugated with specific nanocrystal ( -E. coli-CdS, -campylobacter-PbS and -salmonella-CuS) which has releasable metal ions for electrochemical measurements. The square wave anodic stripping voltammetry (SWASV) was employed to measure released metal ions from bound antibody nanocrystal conjugates. The calibration curves for three selected bacteria were found in the range of 1 × 103 – 5 × 105 cells mL−1 with the limit of detection (LOD) 400 cells mL−1 for salmonella, 400 cells mL−1 for campylobacter and 800 cells mL−1 for E. coli. The precision and sensitivity of this method show the feasibility of multiplexed determination of bacteria in milk samples.
Resumo:
Mestrado (PES II), Educação Pré-Escolar e Ensino do 1º Ciclo do Ensino Básico, 26 de Junho de 2014, Universidade dos Açores.
Resumo:
Trabalho Final de mestrado para obtenção do grau de Mestre em Engenharia Civil
Resumo:
During the last years there has been an increasing concern about occupational exposure to cytostatic drugs in hospitals. The first findings on occupational exposures among hospital personnel administering chemotherapy were reported only in 1979. Since then, a great number of studies have been publishing describing possible exposure-related health effects. Consequently, rigorous guidelines for the safe handling of cancer chemotherapeutic agents were devised and the handling facilities in hospitals were extensively improved. However, recent studies developed in European countries revealed detectable amounts of several drugs in surface wipe samples. Dermal absorption after contact with contaminated surfaces can play an important role in exposure to antineoplastic drugs. Therefore, the existence of contamination in workplace surfaces implies an increased risk of exposure for health care workers. Since there is no recent report in Portugal, regarding the occupational exposure to antineoplastic drugs, a study was developed aiming to determine the 5-fluorouracil (5-FU) contamination on work surfaces of two Portuguese hospitals.
Resumo:
The handling of waste can be responsible for occupational exposure to particles and fungi. The aim of this study was to characterize exposure to particles and fungi in a composting plant. Measurements of particulate matter were performed using portable direct-reading equipment. Air samples of 50L were collected through an impaction method with a flow rate of 140L/min onto malt extract agar supplemented with chloramphenicol (0.05%). Surfaces samples were also collected. All the samples were incubated at 27ºC for 5 to 7 days. Particulate matter data showed higher contamination for PM, and PM10 sizes. Aspergillus genus presents the highest air prevalence (90.6%). Aspergillus niger (32.6%), A. fumigatus (26.5%) and A. flavus (16.3%) were the most prevalent fungi in air sampling, and Mucor sp. (39.2%), Aspergillus niger (30.9%) and A. fumigatus (28.7%) were the most found in surfaces. the results obtained claim the attention to the need of further research.
Resumo:
Several activities are ensured by dockers increase occupational exposure to several risk factors. being one of them the fungal burden from the load. In this study we aim at characterizing fungal contamination in one warehouse that storage sugar cane from a ship, and also in one crane cabinet that unload the same sugar cane from the ship. Air samples were collected from the warehouse and from inside the crane cabinet. An outdoor sample was also collected, from each sampling site, and regarding as reference. Sampling volume was selected depending in the contamination expected and the air samples were collect through an impaction method in a flow rate of 140 L/min onto malt extract agar (MEA) supplemented with chloramphenicol (0.05%), using the Millipore air Tester (Millipore). Surfaces samples from the warehouse were collected by swabbing the surfaces of the same indoor sites, using a 10 by 10cm square stencil according to the International Standard ISO 18593 (2004). The obtained swabs were then plated onto MEA. All the collected samples were incubated at 27ºC for 5 to 7 days. After laboratory processing and incubation of the collected samples, quantitative (colony-forming units - CFU/m3 and CFU/m2) and qualitative results were obtained with identification of the isolated fungal species. Aspergillus fumigatus present the highest fungal load and WHO guideline was overcome in both indoor sampling sites. The results obtained in this study highlight the need to know better the exposure burden from dockers, and specifically to fungi contamination.
Resumo:
The handling of waste and compost that occurs frequently in composting plants (compost turning, shredding, and screening) has been shown to be responsible for the release of dust and air borne microorganisms and their compounds in the air. Thermophilic fungi, such as A. fumigatus, have been reported and this kind of contamination in composting facilities has been associated with increased respiratory symptoms among compost workers. This study intended to characterize fungal contamination in a totally indoor composting plant located in Portugal. Besides conventional methods, molecular biology was also applied to overcome eventual limitations.
Resumo:
Organic waste is a rich substrate for microbial growth, and because of that, workers from waste industry are at higher risk of exposure to bioaerosols. This study aimed to assess fungal contamination in two plants handling solid waste management. Air samples from the two plants were collected through an impaction method. Surface samples were also collected by swabbing surfaces of the same indoor sites. All collected samples were incubated at 27◦C for 5 to 7 d. After lab processing and incubation of collected samples, quantitative and qualitative results were obtained with identification of the isolated fungal species. Air samples were also subjected to molecular methods by real-time polymerase chain reaction (RT PCR) using an impinger method to measure DNA of Aspergillus flavus complex and Stachybotrys chartarum. Assessment of particulate matter (PM) was also conducted with portable direct-reading equipment. Particles concentration measurement was performed at five different sizes (PM0.5; PM1; PM2.5; PM5; PM10). With respect to the waste sorting plant, three species more frequently isolated in air and surfaces were A. niger (73.9%; 66.1%), A. fumigatus (16%; 13.8%), and A. flavus (8.7%; 14.2%). In the incineration plant, the most prevalent species detected in air samples were Penicillium sp. (62.9%), A. fumigatus (18%), and A. flavus (6%), while the most frequently isolated in surface samples were Penicillium sp. (57.5%), A. fumigatus (22.3%) and A. niger (12.8%). Stachybotrys chartarum and other toxinogenic strains from A. flavus complex were not detected. The most common PM sizes obtained were the PM10 and PM5 (inhalable fraction). Since waste is the main internal fungal source in the analyzed settings, preventive and protective measures need to be maintained to avoid worker exposure to fungi and their metabolites.
Resumo:
A procura de piscinas para a prática de atividades desportivas, recreativas e/ou terapêuticas tem sofrido um aumento gradual ao longo do tempo. No entanto, nas piscinas existem vários perigos associados à sua utilização. Relativamente aos perigos químicos, a utilização de desinfetantes à base de cloro, bromo ou compostos derivados vai, por um lado, inativar microrganismos patogénicos mas, por outro, dar origem a subprodutos ao reagir com compostos orgânicos presentes na água. Os trihalometanos são um exemplo de subprodutos que se podem formar e, entre os compostos principais, estão o clorofórmio (TCM), bromodiclorometano (BDCM), clorodibromometano (CDBM) e bromofórmio (TBM). Este trabalho teve como objetivo o desenvolvimento de uma metodologia analítica para a determinação de trihalometanos em água e ar de piscinas e a sua aplicação a um conjunto de amostras. Para a análise dos compostos, foi utilizada a microextração em fase sólida no espaço de cabeça (HS-SPME) com posterior quantificação dos compostos por cromatografia gasosa com detetor de captura eletrónica (GC-ECD). Foi realizada uma otimização das condições de extração dos compostos em estudo em amostras de água, através da realização de dois planeamentos experimentais. As condições ótimas são assim obtidas para uma temperatura de extração de 45ºC, um tempo de extração de 25 min e um tempo de dessorção de 5 min. Foram analisadas amostras de águas de piscina cedidas pelo Centro de Estudos de Águas, sendo avaliada a aplicação da técnica HS-SPME e o efeito de matriz. O modo como se manuseiam as soluções que contêm os compostos em estudo influencia os resultados devido ao facto destes serem bastante voláteis. Concluiu-se também que existe efeito de matriz, logo a concentração das amostras deverá ser determinada através do método de adição de padrão. A caraterização da água de piscinas interiores permitiu conhecer a concentração de trihalometanos (THMs). Foram obtidas concentrações de TCM entre 4,5 e 406,5 μg/L sendo que apenas 4 das 27 amostras analisadas ultrapassam o valor limite imposto pelo Decreto-Lei nº306/2007 (100 μg/L) no que diz respeito a águas de consumo humano e que é normalmente utilizado como valor indicativo para a qualidade das águas de piscina. Relativamente à concentração obtida no ar de uma piscina interior, foi detetada uma concentração média de 224 μg/m3 de TCM, valor muito abaixo dos 10000 μg/m3 impostos pelo Decreto-lei nº24/2012, como valor limite para exposição profissional a agentes químicos.