890 resultados para Sensitivity and Specificity
Resumo:
The principal aim of this work was to examine the effects of antiepileptic drugs (AEDs) on vision. Vigabatrin acts by increasing GABA at brain inhibitory synapses by irreversibly binding to GABA-transaminase. Remacemide is a novel non-competitive NMDA receptor antagonist and fast sodium channel inhibitor that results in the inhibition of the NMDA receptors located in the neuronal membrane calcium channels increasing glutamate in the brain. Vigabatrin has been shown to cause a specific pattern of visual field loss, as one in three adults taking vigabatrin have shown a bilateral concentric constriction. Remacemide has unknown effects on vision. The majority of studies of the effects of AEDs on vision have not included the paediatric population due to difficulties assessing visual field function using standard perimetry testing. Evidently an alternative test is required to establish and monitor visual field problems associated with AEDs both in children and in adults who cannot comply with perimetry. In order to test paediatric patients exposed to vigabatrin, a field-specific visual evoked potential was developed. Other tests performed on patients taking either vigabatrin or remacemide were electroretinograms, electro-oculograms, multifocal VEPs and perimetry. Comparing these tests to perimetry results from vigabatrin patients the field specific VEP was found to have a high sensitivity and specificity, as did the 30Hz flicker amplitude. The modified VEP was also found to provide useful results in vigabatrin patients. Remacemide did not produce a similar visual field loss to vigabatrin although macular vision was affected. The field specific VEP is a useful method for detecting vigabatrin associated visual field loss that is well tolerated by young children. This technique combined with the ERG under light adapted (30Hz flicker) condition is presently the superior method for detecting vigabatrin-attributed peripheral field defects present in children below the developmental age of 9. The effects of AEDs on vision should be monitored carefully and the use of multifocal stimulation allows for specific areas of the retina and visual pathway to be monitored.
Resumo:
The coagulase-negative staphylococci are the most frequent cause of sepsis associated with indwelling intravascular catheters. Current microbiological investigations to support the diagnosis of catheter-related sepsis (CRS) include the culture of blood and catheter tips, however positive results may reflect specimen contamination, or colonisation of the catheter rather than true sepsis. Previous serological approaches to assist in the diagnosis of CRS based on cellular staphylococcal antigens have been of limited value. In this current study, the serodiagnostic potential of an exocellular antigen produced by 7 strains of coagulase-negative staphylococci cultured in brain heart infusion broth was investigated. Antigenic material isolated by gel permeation from liquid culture was characterised by immunological techniques and chemical analysis. Characterisation of the exocellular antigen revealed a novel glycerophosphoglycolipid, termed lipid S. which shared antigenic determinants with lipoteichoic acid, but differed by comprising a glycerophosphate chain length of only 6 units. In addition, lipid S was immunologically distinct from diphosphatidyl glycerol, a constituent cell membrane phospho lipid. An indirect enzyme linked immunosorbent assay (ELISA) based on lipid S was subsequently developed and used to determine serum antibody levels (IgM and IgG) in 67 patients with CRS due to staphylococci, and 67 patients with a central venous catheter (CVC) in situ who exhibited no evidence of sepsis. The sensitivity and specificity of the lipid S IgG ELISA was 75% and 90% respectively whilst the IgM assay had sensitivity and specificity of 52% and 85%. The addition of GullSORereagent to the EL1SA procedure to remove competing serum IgG and rheumatoid factor did not significantly improve the performance of the IgM assay. The serological response in serial serum samples of 13 patients with CRS due to staphylococci was investigated. Elevated levels of antibody were detected at an early stage of infection, prior to the isolation of microorganisms by standard culture methods, and before the clinical presentation of sepsis in 3 patients. The lipid S ELISA was later optimised and a rapid 4-hour assay developed for the serodiagnosis of CRS. Serum IgG levels were determined in 40 patients with CRS due to staphylococci and 40 patients with a CVC in situ who exhibited no evidence of sepsis. The sensitivity and specificity of the rapid IgG assay was 70% and 100% respectively. Elevated serum antibody levels in patients with endocarditis, prosthetic joint infection and pyogenic spondylodiscitis due to Gram-positive cocci were also detected with the lipid S ELISA suggesting that the assay may facilitate the diagnosis of these infections. Unexpected increased levels of anti-lipid S IgG in 31% of control patients with sciatica suggested a possible microbial aetiology of this condition. Further investigation of some of these patients by culture of microdiscectomy tissue removed at operation, revealed the presence of low-virulent microorganisms in 37% of patients of which Propionibacterium aeries accounted for 85% of the positive culture isolates. The results suggested a previously unrecognised association between P. acnes and sciatica, which may have implications for the future management of the condition.
Resumo:
OBJECTIVE: The aim of this study was to devise a scoring system that could aid in predicting neurologic outcome at the onset of neonatal seizures. METHODS: A total of 106 newborns who had neonatal seizures and were consecutively admitted to the NICU of the University of Parma from January 1999 through December 2004 were prospectively followed-up, and neurologic outcome was assessed at 24 months’ postconceptional age. We conducted a retrospective analysis on this cohort to identify variables that were significantly related to adverse outcome and to develop a scoring system that could provide early prognostic indications. RESULTS: A total of 70 (66%) of 106 infants had an adverse neurologic outcome. Six variables were identified as the most important independent risk factors for adverse outcome and were used to construct a scoring system: birth weight, Apgar score at 1 minute, neurologic examination at seizure onset, cerebral ultrasound, efficacy of anticonvulsant therapy, and presence of neonatal status epilepticus. Each variable was scored from 0 to 3 to represent the range from “normal” to “severely abnormal.” A total composite score was computed by addition of the raw scores of the 6 variables. This score ranged from 0 to 12. A cutoff score of =4 provided the greatest sensitivity and specificity. CONCLUSIONS: This scoring system may offer an easy, rapid, and reliable prognostic indicator of neurologic outcome after the onset of neonatal seizures. A final assessment of the validity of this score in routine clinical practice will require independent validation in other centers.
Resumo:
Background - Bipolar disorder (BD) is one of the leading causes of disability worldwide. Patients are further disadvantaged by delays in accurate diagnosis ranging between 5 and 10 years. We applied Gaussian process classifiers (GPCs) to structural magnetic resonance imaging (sMRI) data to evaluate the feasibility of using pattern recognition techniques for the diagnostic classification of patients with BD. Method - GPCs were applied to gray (GM) and white matter (WM) sMRI data derived from two independent samples of patients with BD (cohort 1: n = 26; cohort 2: n = 14). Within each cohort patients were matched on age, sex and IQ to an equal number of healthy controls. Results - The diagnostic accuracy of the GPC for GM was 73% in cohort 1 and 72% in cohort 2; the sensitivity and specificity of the GM classification were respectively 69% and 77% in cohort 1 and 64% and 99% in cohort 2. The diagnostic accuracy of the GPC for WM was 69% in cohort 1 and 78% in cohort 2; the sensitivity and specificity of the WM classification were both 69% in cohort 1 and 71% and 86% respectively in cohort 2. In both samples, GM and WM clusters discriminating between patients and controls were localized within cortical and subcortical structures implicated in BD. Conclusions - Our results demonstrate the predictive value of neuroanatomical data in discriminating patients with BD from healthy individuals. The overlap between discriminative networks and regions implicated in the pathophysiology of BD supports the biological plausibility of the classifiers.
Resumo:
Objective: The purpose of this study was to examine the effectiveness of a new analysis method of mfVEP objective perimetry in the early detection of glaucomatous visual field defects compared to the gold standard technique. Methods and patients: Three groups were tested in this study; normal controls (38 eyes), glaucoma patients (36 eyes), and glaucoma suspect patients (38 eyes). All subjects underwent two standard 24-2 visual field tests: one with the Humphrey Field Analyzer and a single mfVEP test in one session. Analysis of the mfVEP results was carried out using the new analysis protocol: the hemifield sector analysis protocol. Results: Analysis of the mfVEP showed that the signal to noise ratio (SNR) difference between superior and inferior hemifields was statistically significant between the three groups (analysis of variance, P<0.001 with a 95% confidence interval, 2.82, 2.89 for normal group; 2.25, 2.29 for glaucoma suspect group; 1.67, 1.73 for glaucoma group). The difference between superior and inferior hemifield sectors and hemi-rings was statistically significant in 11/11 pair of sectors and hemi-rings in the glaucoma patients group (t-test P<0.001), statistically significant in 5/11 pairs of sectors and hemi-rings in the glaucoma suspect group (t-test P<0.01), and only 1/11 pair was statistically significant (t-test P<0.9). The sensitivity and specificity of the hemifield sector analysis protocol in detecting glaucoma was 97% and 86% respectively and 89% and 79% in glaucoma suspects. These results showed that the new analysis protocol was able to confirm existing visual field defects detected by standard perimetry, was able to differentiate between the three study groups with a clear distinction between normal patients and those with suspected glaucoma, and was able to detect early visual field changes not detected by standard perimetry. In addition, the distinction between normal and glaucoma patients was especially clear and significant using this analysis. Conclusion: The new hemifield sector analysis protocol used in mfVEP testing can be used to detect glaucomatous visual field defects in both glaucoma and glaucoma suspect patients. Using this protocol, it can provide information about focal visual field differences across the horizontal midline, which can be utilized to differentiate between glaucoma and normal subjects. The sensitivity and specificity of the mfVEP test showed very promising results and correlated with other anatomical changes in glaucomatous visual field loss. The intersector analysis protocol can detect early field changes not detected by the standard Humphrey Field Analyzer test. © 2013 Mousa et al, publisher and licensee Dove Medical Press Ltd.
Resumo:
Objectives: To determine the sensitivity and specificity of a novel ELISA for the serodiagnosis of surgical site infection (SSI) due to staphylococci following median sternotomy. Methods: Twelve patients with a superficial sternal SSI and 19 with a deep sternal SSI due to Staphylococcus aureus were compared with 37 control patients who also underwent median sternotomy for cardiac surgery but exhibited no microbiological or clinical symptoms of infection. A further five patients with sternal SSI due to coagulase-negative (CoNS) staphylococci were studied. An ELISA incorporating a recently recognised exocellular short chain form of lipoteichoic acid (lipid S) recovered from CoNS, was used to determine serum levels of anti-lipid S IgG in all patient groups. Results: Serum anti-lipid S IgG titres of patients with sternal SSI due to S. aureus were significantly higher than the control patients (P<0.0001). In addition, patients with deep sternal SSI had significantly higher serum anti-lipid S IgG titres than patients with superficial sternal SSI (P=0.03). Serum anti-lipid S IgG titres of patients with sternal SSI due to CoNS were significantly higher than the control patients (P=0.001). Conclusion: The lipid S ELISA may facilitate the diagnosis of sternal SSI due to S. aureus and could also be of value with infection due to CoNS. © 2005 Published by Elsevier Ltd. on behalf of The Bristish Infection Society.
Resumo:
Background: Despite initial concerns about the sensitivity of the proposed diagnostic criteria for DSM-5 Autism Spectrum Disorder (ASD; e.g. Gibbs et al., 2012; McPartland et al., 2012), evidence is growing that the DSM-5 criteria provides an inclusive description with both good sensitivity and specificity (e.g. Frazier et al., 2012; Kent, Carrington et al., 2013). The capacity of the criteria to provide high levels of sensitivity and specificity comparable with DSM-IV-TR however relies on careful measurement to ensure that appropriate items from diagnostic instruments map onto the new DSM-5 descriptions.Objectives: To use an existing DSM-5 diagnostic algorithm (Kent, Carrington et .al., 2013) to identify a set of ‘essential’ behaviors sufficient to make a reliable and accurate diagnosis of DSM-5 Autism Spectrum Disorder (ASD) across age and ability level. Methods: Specific behaviors were identified and tested from the recently published DSM-5 algorithm for the Diagnostic Interview for Social and Communication Disorders (DISCO). Analyses were run on existing DISCO datasets, with a total participant sample size of 335. Three studies provided step-by-step development towards identification of a minimum set of items. Study 1 identified the most highly discriminating items (p<.0001). Study 2 used a lower selection threshold than in Study 1 (p<.05) to facilitate better representation of the full DSM-5 ASD profile. Study 3 included additional items previously reported as significantly more frequent in individuals with higher ability. The discriminant validity of all three item sets was tested using Receiver Operating Characteristic curves. Finally, sensitivity across age and ability was investigated in a subset of individuals with ASD (n=190).Results: Study 1 identified an item set (14 items) with good discriminant validity, but which predominantly measured social-communication behaviors (11/14). The Study 2 item set (48 items) better represented the DSM-5 ASD and had good discriminant validity, but the item set lacked sensitivity for individuals with higher ability. The final Study 3 adjusted item set (54 items) improved sensitivity for individuals with higher ability and performance and was comparable to the published DISCO DSM-5 algorithm.Conclusions: This work represents a first attempt to derive a reduced set of behaviors for DSM-5 directly from an existing standardized ASD developmental history interview. Further work involving existing ASD diagnostic tools with community-based and well characterized research samples will be required to replicate these findings and exploit their potential to contribute to a more efficient and focused ASD diagnostic process.
Resumo:
Background Introduction of proposed criteria for DSM-5 Autism Spectrum Disorder (ASD) has raised concerns that some individuals currently meeting diagnostic criteria for Pervasive Developmental Disorder (PDD; DSM-IV-TR/ICD-10) will not qualify for a diagnosis under the proposed changes. To date, reports of sensitivity and specificity of the new criteria have been inconsistent across studies. No study has yet considered how changes at the 'sub domain' level might affect overall sensitivity and specificity, and few have included individuals of different ages and ability levels. Methods A set of DSM-5 ASD algorithms were developed using items from the Diagnostic Interview for Social and Communication Disorders (DISCO). The number of items required for each DSM-5 subdomain was defined either according to criteria specified by DSM-5 (Initial Algorithm), a statistical approach (Youden J Algorithm), or to minimise the number of false positives while maximising sensitivity (Modified Algorithm). The algorithms were designed, tested and compared in two independent samples (Sample 1, N = 82; Sample 2, N = 115), while sensitivity was assessed across age and ability levels in an additional dataset of individuals with an ICD-10 PDD diagnosis (Sample 3, N = 190). Results Sensitivity was highest in the Initial Algorithm, which had the poorest specificity. Although Youden J had excellent specificity, sensitivity was significantly lower than in the Modified Algorithm, which had both good sensitivity and specificity. Relaxing the domain A rules improved sensitivity of the Youden J Algorithm, but it remained less sensitive than the Modified Algorithm. Moreover, this was the only algorithm with variable sensitivity across age. All versions of the algorithm performed well across ability level. Conclusions This study demonstrates that good levels of both sensitivity and specificity can be achieved for a diagnostic algorithm adhering to the DSM-5 criteria that is suitable across age and ability level. © 2013 The Authors. Journal of Child Psychology and Psychiatry © 2013 Association for Child and Adolescent Mental Health.
Resumo:
We present the development and simplification of label-free fiber optic biosensors based on immobilization of oligonucleotides on dual-peak long period gratings (dLPGs). This improvement is the result of a simplification of biofunctionalization methodology. A one-step 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide (EDC)-mediated reaction has been developed for the straightforward immobilization of unmodified oligonucleotides on the glass fiber surface along the grating region, leading to covalent attachment of a 5´-phosphorylated probe oligonucleotide to the amino-derivatized fiber grating surface. Immobilization is achieved via a 5´phosphate-specific linkage, leaving the remainder of the oligonucleotide accessible for binding reactions. The dLPG has been tested in different external media to demonstrate its inherent ultrahigh sensitivity to the surrounding-medium refractive index (RI) achieving 50- fold improvement in RI sensitivity over the previously-published LPG sensor in media with RI’s relevant to biological assays. After functionalization, the dLPG biosensor was used to monitor the hybridization of complementary oligonucleotides showing a detectable oligonucleotide concentration of 4 nM. The proposed one-step EDC reaction approach can be further extended to develop fiber optic biosensors for disease analysis and medical diagnosis with the advances of label-free, real-time, multiplex, high sensitivity and specificity.
Resumo:
Objectives: To determine the best photographic surrogate markers for detecting sight-threatening macular oedema (MO) in people with diabetes attending UK national screening programmes. Design: A multicentre, prospective, observational cohort study of 3170 patients with photographic signs of diabetic retinopathy visible within the macular region [exudates within two disc diameters, microaneurysms/dot haemorrhages (M/DHs) and blot haemorrhages (BHs)] who were recruited from seven study centres. Setting: All patients were recruited and imaged at one of seven study centres in Aberdeen, Birmingham, Dundee, Dunfermline, Edinburgh, Liverpool and Oxford. Participants: Subjects with features of diabetic retinopathy visible within the macular region attending one of seven diabetic retinal screening programmes. Interventions: Alternative referral criteria for suspected MO based on photographic surrogate markers; an optical coherence tomographic examination in addition to the standard digital retinal photograph. Main outcome measures: (1) To determine the best method to detect sight-threatening MO in people with diabetes using photographic surrogate markers. (2) Sensitivity and specificity estimates to assess the costs and consequences of using alternative strategies. (3) Modelled long-term costs and quality-adjusted life-years (QALYs). Results: Prevalence of MO was strongly related to the presence of lesions and was roughly five times higher in subjects with exudates or BHs or more than two M/DHs within one disc diameter. Having worse visual acuity was associated with about a fivefold higher prevalence of MO. Current manual screening grading schemes that ignore visual acuity or the presence of M/DHs could be improved by taking these into account. Health service costs increase substantially with more sensitive/less specific strategies. A fully automated strategy, using the automated detection of patterns of photographic surrogate markers, is superior to all current manual grading schemes for detecting MO in people with diabetes. The addition of optical coherence tomography (OCT) to each strategy, prior to referral, results in a reduction in costs to the health service with no decrement in the number of MO cases detected. Conclusions: Compared with all current manual grading schemes, for the same sensitivity, a fully automated strategy, using the automated detection of patterns of photographic surrogate markers, achieves a higher specificity for detecting MO in people with diabetes, especially if visual acuity is included in the automated strategy. Overall, costs to the health service are likely to increase if more sensitive referral strategies are adopted over more specific screening strategies for MO, for only very small gains in QALYs. The addition of OCT to each screening strategy, prior to referral, results in a reduction in costs to the health service with no decrement in the number of MO cases detected. © Queen's Printer and Controller of HMSO 2013.
Resumo:
A protocol with repeated stimulation cycles should be analyzed stepwise, in that each stimulation is evaluated, and a reaction pattern is identified. No two subjects will react identically, in that dilation and recovery times can vary; however, this is not reason enough to abandon a multiple stimulation cycle with fixed recovery and stimulation times. Furthermore, it enables us to examine and determine the range in which a normal subject will be placed and can then be compared to different pathophysiological states (i.e., smokers and different diseases). The purpose of our paper was to highlight the importance of evaluating these different cycles and the danger of false interpretation when averaging results. There are many different ways of evaluating dilatory responses and elasticity, but each of them must be carefully evaluated and should not be overaveraged, which can result in a loss of sensitivity and specificity.
Resumo:
Fluorescence-enhanced optical imaging is an emerging non-invasive and non-ionizing modality towards breast cancer diagnosis. Various optical imaging systems are currently available, although most of them are limited by bulky instrumentation, or their inability to flexibly image different tissue volumes and shapes. Hand-held based optical imaging systems are a recent development for its improved portability, but are currently limited only to surface mapping. Herein, a novel optical imager, consisting primarily of a hand-held probe and a gain-modulated intensified charge coupled device (ICCD) detector, is developed towards both surface and tomographic breast imaging. The unique features of this hand-held probe based optical imager are its ability to; (i) image large tissue areas (5×10 sq. cm) in a single scan, (ii) reduce overall imaging time using a unique measurement geometry, and (iii) perform tomographic imaging for tumor three-dimensional (3-D) localization. Frequency-domain based experimental phantom studies have been performed on slab geometries (650 ml) under different target depths (1-2.5 cm), target volumes (0.45, 0.23 and 0.10 cc), fluorescence absorption contrast ratios (1:0, 1000:1 to 5:1), and number of targets (up to 3), using Indocyanine Green (ICG) as fluorescence contrast agents. An approximate extended Kalman filter based inverse algorithm has been adapted towards 3-D tomographic reconstructions. Single fluorescence target(s) was reconstructed when located: (i) up to 2.5 cm deep (at 1:0 contrast ratio) and 1.5 cm deep (up to 10:1 contrast ratio) for 0.45 cc-target; and (ii) 1.5 cm deep for target as small as 0.10 cc at 1:0 contrast ratio. In the case of multiple targets, two targets as close as 0.7 cm were tomographically resolved when located 1.5 cm deep. It was observed that performing multi-projection (here dual) based tomographic imaging using a priori target information from surface images, improved the target depth recovery over using single projection based imaging. From a total of 98 experimental phantom studies, the sensitivity and specificity of the imager was estimated as 81-86% and 43-50%, respectively. With 3-D tomographic imaging successfully demonstrated for the first time using a hand-held based optical imager, the clinical translation of this technology is promising upon further experimental validation from in-vitro and in-vivo studies.
Resumo:
This dissertation established a state-of-the-art programming tool for designing and training artificial neural networks (ANNs) and showed its applicability to brain research. The developed tool, called NeuralStudio, allows users without programming skills to conduct studies based on ANNs in a powerful and very user friendly interface. A series of unique features has been implemented in NeuralStudio, such as ROC analysis, cross-validation, network averaging, topology optimization, and optimization of the activation function’s slopes. It also included a Support Vector Machines module for comparison purposes. Once the tool was fully developed, it was applied to two studies in brain research. In the first study, the goal was to create and train an ANN to detect epileptic seizures from subdural EEG. This analysis involved extracting features from the spectral power in the gamma frequencies. In the second application, a unique method was devised to link EEG recordings to epileptic and nonepileptic subjects. The contribution of this method consisted of developing a descriptor matrix that can be used to represent any EEG file regarding its duration and the number of electrodes. The first study showed that the inter-electrode mean of the spectral power in the gamma frequencies and its duration above a specific threshold performs better than the other frequencies in seizure detection, exhibiting an accuracy of 95.90%, a sensitivity of 92.59%, and a specificity of 96.84%. The second study yielded that Hjorth’s parameter activity is sufficient to accurately relate EEG to epileptic and non-epileptic subjects. After testing, accuracy, sensitivity and specificity of the classifier were all above 0.9667. Statistical tests measured the superiority of activity at over 99.99 % certainty. It was demonstrated that (1) the spectral power in the gamma frequencies is highly effective in locating seizures from EEG and (2) activity can be used to link EEG recordings to epileptic and non-epileptic subjects. These two studies required high computational load and could be addressed thanks to NeuralStudio. From a medical perspective, both methods proved the merits of NeuralStudio in brain research applications. For its outstanding features, NeuralStudio has been recently awarded a patent (US patent No. 7502763).
Resumo:
Background As the use of electronic health records (EHRs) becomes more widespread, so does the need to search and provide effective information discovery within them. Querying by keyword has emerged as one of the most effective paradigms for searching. Most work in this area is based on traditional Information Retrieval (IR) techniques, where each document is compared individually against the query. We compare the effectiveness of two fundamentally different techniques for keyword search of EHRs. Methods We built two ranking systems. The traditional BM25 system exploits the EHRs' content without regard to association among entities within. The Clinical ObjectRank (CO) system exploits the entities' associations in EHRs using an authority-flow algorithm to discover the most relevant entities. BM25 and CO were deployed on an EHR dataset of the cardiovascular division of Miami Children's Hospital. Using sequences of keywords as queries, sensitivity and specificity were measured by two physicians for a set of 11 queries related to congenital cardiac disease. Results Our pilot evaluation showed that CO outperforms BM25 in terms of sensitivity (65% vs. 38%) by 71% on average, while maintaining the specificity (64% vs. 61%). The evaluation was done by two physicians. Conclusions Authority-flow techniques can greatly improve the detection of relevant information in EHRs and hence deserve further study.
Resumo:
OBJECTIVE: To evaluate the validity of hemoglobin A1C (A1C) as a diagnostic tool for type 2 diabetes and to determine the most appropriate A1C cutoff point for diagnosis in a sample of Haitian-Americans. SUBJECTS AND METHODS: Subjects (n = 128) were recruited from Miami-Dade and Broward counties, FL. Receiver operating characteristics (ROC) analysis was run in order to measure sensitivity and specificity of A1C for detecting diabetes at different cutoff points. RESULTS: The area under the ROC curve was 0.86 using fasting plasma glucose ≥ 7.0 mmol/L as the gold standard. An A1C cutoff point of 6.26% had sensitivity of 80% and specificity of 74%, whereas an A1C cutoff point of 6.50% (recommended by the American Diabetes Association – ADA) had sensitivity of 73% and specificity of 89%. CONCLUSIONS: A1C is a reliable alternative to fasting plasma glucose in detecting diabetes in this sample of Haitian-Americans. A cutoff point of 6.26% was the optimum value to detect type 2 diabetes.