997 resultados para Safety glass.
Resumo:
With the installation by the Pacific Electric Railway of a bus system in Pasadena to supplant most of its trolley lines, the problem of the comparison of the costs of the two systems naturally presented itself. The study here undertaken was originally started as just a comparison of the motor bus and Birney Safety Car, but as the work progressed it seemed advisable to include the trolley bus as well - a method of transportation that is comparatively new as far as development is concerned, but which seems to be finding increasing favor in the East.
Resumo:
Ultrafast lasers ablation of Cr film was investigated by using double-pulse method. Experimental results show that there exists a temporal ablation window effect with each of the double pulses adjusted just smaller than the threshold. When the delay between the double pulses is within the order of 400 ps, the ablation of Cr film could happen. When the delay between the double pulses is beyond the order of 400 ps, the ablation of Cr film would not happen, and the reflectivity from the surface of the Cr film shows a sharp rise at the same time. The two-temperature model was developed into the form of double pulses to explain the experimental phenomena. Furthermore, microbump structures were formed on the surface of Cr film after ablation by ultrafast double pulses. Their heights exhibit an obvious drop between 1 and 10 ps double pulses delay, which is involved with the electron-phonon coupling process according to the numerical simulation. These results should be helpful for understanding the dynamic processes during ultrafast lasers ablation of metal films. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
Background: Vascular ulcers are commonly seen in daily practice at all levels of care and have great impact at personal, professional and social levels with a high cost in terms of human and material resources. Given that the application of autologous platelet rich plasma has been shown to decrease healing times in various different studies in the hospital setting, we considered that it would be interesting to assess the efficacy and feasibility of this treatment in primary care. The objectives of this study are to assess the potential efficacy and safety of autologous platelet rich plasma for the treatment of venous ulcers compared to the conventional treatment (moist wound care) in primary care patients with chronic venous insufficiency (C, clinical class, E, aetiology, A, anatomy and P, pathophysiology classification C6). Design: We will conduct a phase III, open-label, parallel-group, multicentre, randomized study. The subjects will be 150 patients aged between 40 and 100 years of age with an at least 2-month history of a vascular venous ulcer assigned to ten primary care centres. For the treatment with autologous platelet rich plasma, all the following tasks will be performed in the primary care setting: blood collection, centrifugation, separation of platelet rich plasma, activation of coagulation adding calcium chloride and application of the PRP topically after gelification. The control group will receive standard moist wound care. The outcome variables to be measured at baseline, and at weeks 5 and 9 later include: reduction in the ulcer area, Chronic Venous Insufficiency Quality of Life Questionnaire score, and percentage of patients who require wound care only once a week. Discussion: The results of this study will be useful to improve the protocol for using platelet rich plasma in chronic vascular ulcers and to favour wider use of this treatment in primary care.
Resumo:
Second-harmonic generation was observed in Ge(20)AS(25)S(55) chalcogenide glass irradiated by an electron beam. The second-harmonic intensity increased with increasing electron-beam current and accelerating voltage. The second-harmonic generation in Ge20As25S55 glass was caused by the space-charge electrostatic field that was generated by irradiation of an electron beam. Second-order nonlinearity chi ((2)) as great as 0.8 pm/V was obtained. The results of measurements of thermally stimulated depolarization current indicated that the glass was poled in the thin layers of its surface (several micrometers) and that the nonlinearity was stable. (C) 2001 Optical Society of America.
Resumo:
Early glasses (about 1066 BC-220 AD) unearthed from Xinjiang of China were chemically characterized by using PIXE and ICP-AES. It was found that these glasses were basically attributed to PbO-BaO-SiO2 system, K2O-SiO2 system, Na2O-CaO-SiO2 system and Na2O-CaO-PbO-SiO2 system. The results from the cluster analysis showed that some glasses had basically similar recipe and technology. The PbO-BaO-SiO2 glass and the K2O-SiO2 glass were thought to come from the central area and the south of ancient China, respectively. The part of the Na2O-CaO-SiO2 glass (including the Na2O-CaO-PbO-SiO2 glass) might be imported from Mesopotamia, while the other part might be locally produced. (c) 2005 Elsevier B.V. All rights reserved.