941 resultados para SPICE simulations
Resumo:
In this work the problem of performing a numerical simulation of quasi-static crack propagation within an adhesive layer of a bonded joint under Mode I loading affected by stress field changes due to thermal-chemical shrinkage induced by cure process is addressed. Secondly, a parametric study on fracture critical energy, cohesive strength and Young's modulus is performed. Finally, a particular case of adhesive layer stiffening is simulated in order to verify qualitatively the major effect.
Resumo:
L'obiettivo di questo lavoro è quello di analizzare la stabilità di uno spettro raggi X emesso da un tubo usurato per analisi cardiovascolari, in modo da verificare il suo comportamento. Successivamente questo tipo di analisi sarà effettuata su tubi CT. Per raggiungere questo scopo è stato assemblato un particolare set-up con un rivelatore al germanio criogenico in modo da avere la miglior risoluzione energetica possibile ed alcuni particolari collimatori così da ridurre il flusso fotonico per evitare effetti di pile-up. Il set-up è stato costruito in modo da avere il miglior allineamento possibile nel modo più veloce possibile, e con l'obiettivo di rendere l'intero sistema portabile. Il tubo usato è un SRM Philips tube per analisi cardiovascolari; questa scelta è stata fatta in modo da ridurre al minimo i fattori esterni (ottica elettromagnetica, emettitori) e concentrare l'attenzione solo sugli effetti, causati dalle varie esposizioni, sull'anodo (roughness e bending) e sul comportamento di essi durante il surriscaldamento e successivo raffreddamento del tubo. I risultati mostrano come durante un'esposizione alcuni fattori di usura del tubo possono influire in maniera sostanziale sullo spettro ottenuto e quindi alterare il risultato. Successivamente, nell'elaborato, mediante il software Philips di ricostruzione e simulazione dello spettro si è cercato di riprodurre, variando alcuni parametri, la differenza riscontrata sperimentalmente in modo da poter simulare l'instabilità e correggere i fattori che la causano. I risultati sono interessanti non solo per questo esperimento ma anche in ottica futura, per lo sviluppo di applicazioni come la spectral CT. Il passo successivo sarà quello di spostare l'attenzione su un CT tube e verificare se l'instabilità riscontrata in questo lavoro è persiste anche in una analisi più complessa come quella CT.
Resumo:
Software is available, which simulates all basic electrophoretic systems, including moving boundary electrophoresis, zone electrophoresis, ITP, IEF and EKC, and their combinations under almost exactly the same conditions used in the laboratory. These dynamic models are based upon equations derived from the transport concepts such as electromigration, diffusion, electroosmosis and imposed hydrodynamic buffer flow that are applied to user-specified initial distributions of analytes and electrolytes. They are able to predict the evolution of electrolyte systems together with associated properties such as pH and conductivity profiles and are as such the most versatile tool to explore the fundamentals of electrokinetic separations and analyses. In addition to revealing the detailed mechanisms of fundamental phenomena that occur in electrophoretic separations, dynamic simulations are useful for educational purposes. This review includes a list of current high-resolution simulators, information on how a simulation is performed, simulation examples for zone electrophoresis, ITP, IEF and EKC and a comprehensive discussion of the applications and achievements.
Resumo:
PURPOSE: The advent of imaging software programs has proved to be useful for diagnosis, treatment planning, and outcome measurement, but precision of 3-dimensional (3D) surgical simulation still needs to be tested. This study was conducted to determine whether the virtual surgery performed on 3D models constructed from cone-beam computed tomography (CBCT) can correctly simulate the actual surgical outcome and to validate the ability of this emerging technology to recreate the orthognathic surgery hard tissue movements in 3 translational and 3 rotational planes of space. MATERIALS AND METHODS: Construction of pre- and postsurgery 3D models from CBCTs of 14 patients who had combined maxillary advancement and mandibular setback surgery and 6 patients who had 1-piece maxillary advancement surgery was performed. The postsurgery and virtually simulated surgery 3D models were registered at the cranial base to quantify differences between simulated and actual surgery models. Hotelling t tests were used to assess the differences between simulated and actual surgical outcomes. RESULTS: For all anatomic regions of interest, there was no statistically significant difference between the simulated and the actual surgical models. The right lateral ramus was the only region that showed a statistically significant, but small difference when comparing 2- and 1-jaw surgeries. CONCLUSIONS: Virtual surgical methods were reliably reproduced. Oral surgery residents could benefit from virtual surgical training. Computer simulation has the potential to increase predictability in the operating room.
Resumo:
Supramolecular two-dimensional engineering epitomizes the design of complex molecular architectures through recognition events in multicomponent self-assembly. Despite being the subject of in-depth experimental studies, such articulated phenomena have not been yet elucidated in time and space with atomic precision. Here we use atomistic molecular dynamics to simulate the recognition of complementary hydrogen-bonding modules forming 2D porous networks on graphite. We describe the transition path from the melt to the crystalline hexagonal phase and show that self-assembly proceeds through a series of intermediate states featuring a plethora of polygonal types. Finally, we design a novel bicomponent system possessing kinetically improved self-healing ability in silico, thus demonstrating that a priori engineering of 2D self-assembly is possible.
Resumo:
Water vapour, despite being a minor constituent in the Martian atmosphere with its precipitable amount of less than 70 pr. μm, attracts considerable attention in the scientific community because of its potential importance for past life on Mars. The partial pressure of water vapour is highly variable because of its seasonal condensation onto the polar caps and exchange with a subsurface reservoir. It is also known to drive photochemical processes: photolysis of water produces H, OH, HO2 and some other odd hydrogen compounds, which in turn destroy ozone. Consequently, the abundance of water vapour is anti-correlated with ozone abundance. The Herschel Space Observatory provides for the first time the possibility to retrieve vertical water profiles in the Martian atmosphere. Herschel will contribute to this topic with its guaranteed-time key project called "Water and related chemistry in the solar system". Observations of Mars by Heterodyne Instrument for the Far Infrared (HIFI) and Photodetector Array Camera and Spectrometer (PACS) onboard Herschel are planned in the frame of the programme. HIFI with its high spectral resolution enables accurate observations of vertically resolved H2O and temperature profiles in the Martian atmosphere. Unlike HIFI, PACS is not capable of resolving the line-shape of molecular lines. However, our present study of PACS observations for the Martian atmosphere shows that the vertical sensitivity of the PACS observations can be improved by using multiple-line observations with different line opacities. We have investigated the possibility of retrieving vertical profiles of temperature and molecular abundances of minor species including H2O in the Martian atmosphere using PACS. In this paper, we report that PACS is able to provide water vapour vertical profiles for the Martian atmosphere and we present the expected spectra for future PACS observations. We also show that the spectral resolution does not allow the retrieval of several studied minor species, such as H2O2, HCl, NO, SO2, etc.
Resumo:
Molecular dynamics (MD) simulations have been used to study the dynamical and time-averaged characteristics of the DNA triple helix d(T)10âd(A)10âd(T)10. The structures sampled during the trajectory resemble closely the B-type model for the DNA triplex proposed on the basis of NMR data, although there are some subtle differences. Alternative P- and A-type conformations for the triplex, suggested from X-ray experiments, are not predicted to contribute significantly to the structure of the DNA triplex in solution. Comparison with the best available experimental data supports the correctnes of the MD-generated structures. The analysis of the collected data gives a detailed picture of the characteristics of triple-helix DNA. A new and interesting pattern of hydration, specific for triplex DNA, is an important observation. The results suggest that molecular dynamics can be useful for the study of novel nucleic acid structures.
Resumo:
The goals of this article are to (1) provide further validation of the Glycam06 force field, specifically for its use in implicit solvent molecular dynamic (MD) simulations, and (2) to present the extension of G.N. Ramachandran's idea of plotting amino acid phi and psi angles to the glycosidic phi, psi, and omega angles formed between carbohydrates. As in traditional Ramachandran plots, these carbohydrate Ramachandran-type (carb-Rama) plots reveal the coupling between the glycosidic angles by displaying the allowed and disallowed conformational space. Considering two-bond glycosidic linkages, there are 18 possible conformational regions that can be defined by (α, ϕ, ψ) and (β, ϕ, ψ), whereas for three-bond linkages, there are 54 possible regions that can be defined by (α, ϕ, ψ, ω) and (β, ϕ, ψ, ω). Illustrating these ideas are molecular dynamic simulations on an implicitly hydrated oligosaccharide (700 ns) and its eight constituent disaccharides (50 ns/disaccharide). For each linkage, we compare and contrast the oligosaccharide and respective disaccharide carb-Rama plots, validate the simulations and the Glycam06 force field through comparison to experimental data, and discuss the general trends observed in the plots.
Resumo:
Three comprehensive one-dimensional simulators were used on the same PC to simulate the dynamics of different electrophoretic configurations, including two migrating hybrid boundaries, an isotachophoretic boundary and the zone electrophoretic separation of ten monovalent anions. Two simulators, SIMUL5 and GENTRANS, use a uniform grid, while SPRESSO uses a dynamic adaptive grid. The simulators differ in the way components are handled. SIMUL5 and SPRESSO feature one equation for all components, whereas GENTRANS is based on the use of separate modules for the different types of monovalent components, a module for multivalent components and a module for proteins. The code for multivalent components is executed more slowly compared to those for monovalent components. Furthermore, with SIMUL5, the computational time interval becomes smaller when it is operated with a reduced calculation space that features moving borders, whereas GENTRANS offers the possibility of using data smoothing (removal of negative concentrations), which can avoid numerical oscillations and speed up a simulation. SPRESSO with its adaptive grid could be employed to simulate the same configurations with smaller numbers of grid points and thus is faster in certain but not all cases. The data reveal that simulations featuring a large number of monovalent components distributed such that a high mesh is required throughout a large proportion of the column are fastest executed with GENTRANS.
Resumo:
The variability of the Atlantic meridional overturing circulation (AMOC) strength is investigated in control experiments and in transient simulations of up to the last millennium using the low-resolution Community Climate System Model version 3. In the transient simulations the AMOC exhibits enhanced low-frequency variability that is mainly caused by infrequent transitions between two semi-stable circulation states which amount to a 10 percent change of the maximum overturning. One transition is also found in a control experiment, but the time-varying external forcing significantly increases the probability of the occurrence of such events though not having a direct, linear impact on the AMOC. The transition from a high to a low AMOC state starts with a reduction of the convection in the Labrador and Irminger Seas and goes along with a changed barotropic circulation of both gyres in the North Atlantic and a gradual strengthening of the convection in the Greenland-Iceland-Norwegian (GIN) Seas. In contrast, the transition from a weak to a strong overturning is induced by decreased mixing in the GIN Seas. As a consequence of the transition, regional sea surface temperature (SST) anomalies are found in the midlatitude North Atlantic and in the convection regions with an amplitude of up to 3 K. The atmospheric response to the SST forcing associated with the transition indicates a significant impact on the Scandinavian surface air temperature (SAT) in the order of 1 K. Thus, the changes of the ocean circulation make a major contribution to the Scandinavian SAT variability in the last millennium.
Resumo:
Simulations of climate over the Last Millennium (850–1850 CE) have been incorporated into the third phase of the Paleoclimate Modelling Intercomparison Project (PMIP3). The drivers of climate over this period are chiefly orbital, solar, volcanic, changes in land use/land cover and some variation in greenhouse gas levels. While some of these effects can be easily defined, the reconstructions of solar, volcanic and land use-related forcing are more uncertain. We describe here the approach taken in defining the scenarios used in PMIP3, document the forcing reconstructions and discuss likely implications.