907 resultados para Robot navigation
Resumo:
CONTEXT Robot-assisted surgery is increasingly used for radical cystectomy (RC) and urinary reconstruction. Sufficient data have accumulated to allow evidence-based consensus on key issues such as perioperative management, comparative effectiveness on surgical complications, and oncologic short- to midterm outcomes. OBJECTIVE A 2-d conference of experts on RC and urinary reconstruction was organized in Pasadena, California, and the City of Hope Cancer Center in Duarte, California, to systematically review existing peer-reviewed literature on robot-assisted RC (RARC), extended lymphadenectomy, and urinary reconstruction. No commercial support was obtained for the conference. EVIDENCE ACQUISITION A systematic review of the literature was performed in agreement with the PRISMA statement. EVIDENCE SYNTHESIS Systematic literature reviews and individual presentations were discussed, and consensus on all key issues was obtained. Most operative, intermediate-term oncologic, functional, and complication outcomes are similar between open RC (ORC) and RARC. RARC consistently results in less blood loss and a reduced need for transfusion during surgery. RARC generally requires longer operative time than ORC, particularly with intracorporeal reconstruction. Robotic assistance provides ergonomic value for surgeons. Surgeon experience and institutional volume strongly predict favorable outcomes for either open or robotic techniques. CONCLUSIONS RARC appears to be similar to ORC in terms of operative, pathologic, intermediate-term oncologic, complication, and most functional outcomes. RARC consistently results in less blood loss and a reduced need for transfusion during surgery. RARC can be more expensive than ORC, although high procedural volume may attenuate this difference. PATIENT SUMMARY Robot-assisted radical cystectomy (RARC) is an alternative to open surgery for patients with bladder cancer who require removal of their bladder and reconstruction of their urinary tract. RARC appears to be similar to open surgery for most important outcomes such as the rate of complications and intermediate-term cancer-specific survival. Although RARC has some ergonomic advantages for surgeons and may result in less blood loss during surgery, it is more time consuming and may be more expensive than open surgery.
Resumo:
CONTEXT Although open radical cystectomy (ORC) is still the standard approach, laparoscopic radical cystectomy (LRC) and robot-assisted radical cystectomy (RARC) are increasingly performed. OBJECTIVE To report on a systematic literature review and cumulative analysis of pathologic, oncologic, and functional outcomes of RARC in comparison with ORC and LRC. EVIDENCE ACQUISITION Medline, Scopus, and Web of Science databases were searched using a free-text protocol including the terms robot-assisted radical cystectomy or da Vinci radical cystectomy or robot* radical cystectomy. RARC case series and studies comparing RARC with either ORC or LRC were collected. A cumulative analysis was conducted. EVIDENCE SYNTHESIS The searches retrieved 105 papers, 87 of which reported on pathologic, oncologic, or functional outcomes. Most series were retrospective and had small case numbers, short follow-up, and potential patient selection bias. The lymph node yield during lymph node dissection was 19 (range: 3-55), with half of the series following an extended template (yield range: 11-55). The lymph node-positive rate was 22%. The performance of lymphadenectomy was correlated with surgeon and institutional volume. Cumulative analyses showed no significant difference in lymph node yield between RARC and ORC. Positive surgical margin (PSM) rates were 5.6% (1-1.5% in pT2 disease and 0-25% in pT3 and higher disease). PSM rates did not appear to decrease with sequential case numbers. Cumulative analyses showed no significant difference in rates of surgical margins between RARC and ORC or RARC and LRC. Neoadjuvant chemotherapy use ranged from 0% to 31%, with adjuvant chemotherapy used in 4-29% of patients. Only six series reported a mean follow-up of >36 mo. Three-year disease-free survival (DFS), cancer-specific survival (CSS), and overall survival (OS) rates were 67-76%, 68-83%, and 61-80%, respectively. The 5-yr DFS, CSS, and OS rates were 53-74%, 66-80%, and 39-66%, respectively. Similar to ORC, disease of higher pathologic stage or evidence of lymph node involvement was associated with worse survival. Very limited data were available with respect to functional outcomes. The 12-mo continence rates with continent diversion were 83-100% in men for daytime continence and 66-76% for nighttime continence. In one series, potency was recovered in 63% of patients who were evaluable at 12 mo. CONCLUSIONS Oncologic and functional data from RARC remain immature, and longer-term prospective studies are needed. Cumulative analyses demonstrated that lymph node yields and PSM rates were similar between RARC and ORC. Conclusive long-term survival outcomes for RARC were limited, although oncologic outcomes up to 5 yr were similar to those reported for ORC. PATIENT SUMMARY Although open radical cystectomy (RC) is still regarded as the standard treatment for muscle-invasive bladder cancer, laparoscopic and robot-assisted RCs are becoming more popular. Templates of lymph node dissection, lymph node yields, and positive surgical margin rates are acceptable with robot-assisted RC. Although definitive comparisons with open RC with respect to oncologic or functional outcomes are lacking, early results appear comparable.
Resumo:
The aim of direct cochlear access (DCA) is to replace the standard mastoidectomy with a small diameter tunnel from the lateral bone surface to the cochlea for electrode array insertion. In contrast to previous attempts, the approach described in this work not only achieves an unprecedented high accuracy, but also contains several safety sub-systems. This paper provides a brief description of the system components, and summarizes accuracy results using the system in a cadaver model over the past two years.
Resumo:
Femoroacetabular impingement (FAI) before or after Periacetabular Osteotomy (PAO) is surprisingly frequent and surgeons need to be aware of the risk preoperatively and be able to avoid it intraoperatively. In this paper we present a novel computer assisted planning and navigation system for PAO with impingement analysis and range of motion (ROM) optimization. Our system starts with a fully automatic detection of the acetabular rim, which allows for quantifying the acetabular morphology with parameters such as acetabular version, inclination and femoral head coverage ratio for a computer assisted diagnosis and planning. The planned situation was optimized with impingement simulation by balancing acetabuar coverage with ROM. Intra-operatively navigation was conducted until the optimized planning situation was achieved. Our experimental results demonstrated: 1) The fully automated acetabular rim detection was validated with accuracy 1.1 ± 0.7mm; 2) The optimized PAO planning improved ROM significantly compared to that without ROM optimization; 3) By comparing the pre-operatively planned situation and the intra-operatively achieved situation, sub-degree accuracy was achieved for all directions.
Resumo:
HYPOTHESIS To evaluate the feasibility and the results of insertion of two types of electrode arrays in a robotically assisted surgical approach. BACKGROUND Recent publications demonstrated that robot-assisted surgery allows the implantation of free-fitting electrode arrays through a cochleostomy drilled via a narrow bony tunnel (DCA). We investigated if electrode arrays from different manufacturers could be used with this approach. METHODS Cone-beam CT imaging was performed on fivecadaveric heads after placement of fiducial screws. Relevant anatomical structures were segmented and the DCA trajectory, including the position of the cochleostomy, was defined to target the center of the scala tympani while reducing the risk of lesions to the facial nerve. Med-El Flex 28 and Cochlear CI422 electrodes were implanted on both sides, and their position was verified by cone-beam CT. Finally, temporal bones were dissected to assess the occurrence of damage to anatomical structures during DCA drilling. RESULTS The cochleostomy site was directed in the scala tympani in 9 of 10 cases. The insertion of electrode arrays was successful in 19 of 20 attempts. No facial nerve damage was observed. The average difference between the planned and the postoperative trajectory was 0.17 ± 0.19 mm at the level of the facial nerve. The average depth of insertion was 305.5 ± 55.2 and 243 ± 32.1 degrees with Med-El and Cochlear arrays, respectively. CONCLUSIONS Robot-assisted surgery is a reliable tool to allow cochlear implantation through a cochleostomy. Technical solutions must be developed to improve the electrode array insertion using this approach.
Resumo:
In this chapter a low-cost surgical navigation solution for periacetabular osteotomy (PAO) surgery is described. Two commercial inertial measurement units (IMU, Xsens Technologies, The Netherlands), are attached to a patient’s pelvis and to the acetabular fragment, respectively. Registration of the patient with a pre-operatively acquired computer model is done by recording the orientation of the patient’s anterior pelvic plane (APP) using one IMU. A custom-designed device is used to record the orientation of the APP in the reference coordinate system of the IMU. After registration, the two sensors are mounted to the patient’s pelvis and acetabular fragment, respectively. Once the initial position is recorded, the orientation is measured and displayed on a computer screen. A patient-specific computer model generated from a pre-operatively acquired computed tomography (CT) scan is used to visualize the updated orientation of the acetabular fragment. Experiments with plastic bones (7 hip joints) performed in an operating room comparing a previously developed optical navigation system with our inertial-based navigation system showed no statistical difference on the measurement of acetabular component reorientation (anteversion and inclination). In six out of seven hip joints the mean absolute difference was below five degrees for both anteversion and inclination.
Resumo:
PURPOSE The pararectus approach has been validated for managing acetabular fractures. We hypothesised it might be an alternative approach for performing periacetabular osteotomy (PAO). METHODS Using four cadaver specimens, we randomly performed PAO through either the pararectus or a modified Smith-Petersen (SP) approach. We assessed technical feasibility and safety. Furthermore, we controlled fragment mobility using a surgical navigation system and compared mobility between approaches. The navigation system's accuracy was tested by cross-examination with validated preoperative planning software. RESULTS The pararectus approach is technically feasible, allowing for adequate exposure, safe osteotomies and excellent control of structures at risk. Fragment mobility is equal to that achieved through the SP approach. Validation of these measurements yielded a mean difference of less <1 mm without statistical significance. CONCLUSION Experimental data suggests the pararectus approach might be an alternative approach for performing PAO. Clinical validation is necessary to confirm these promising preliminary results.
Resumo:
Welsch (Projektbearbeiter): Vollendung der Bauernbefreiung, nachdem die Leibeigenschaft bereits 1781/82 unter Kaiser Joseph II. aufgehoben wurde: Bekanntgabe der Aufhebung der obrigkeitlichen Gewalt der Grundherren (ohne Entgelt) sowie der Aufhebung der Dienste und Abgaben (gegen Entschädigung). (Einstimmiger Beschluß des österreichischen Reichstages nach dem diesbezüglichen Antrag des Abgeordneten Hans Kudlich vom 26. Juli 1848)
Resumo:
Welsch (Projektbearbeiter): Der Kudlichsche Antrag auf Bauernbefreiung (26. Juli 1848) wird mit einigen Modifikationen (Abgeordneter Lasser) vom österreichischen Reichstag angenommen. Nebst Abdruck von Redebeiträgen aus den Vordebatten
Resumo:
Welsch (Projektbearbeiter): Satirische Kommentierung der Amendements zum Kudlichschen Antrag über die Aufhebung der bäuerlichen Untertänigkeit, die Entschädigungsfrage betreffend
Resumo:
UNLABELLED OBJECTIVE; Virtual autopsy methods, such as postmortem CT and MRI, are increasingly being used in forensic medicine. Forensic investigators with little to no training in diagnostic radiology and medical laypeople such as state's attorneys often find it difficult to understand the anatomic orientation of axial postmortem CT images. We present a computer-assisted system that permits postmortem CT datasets to be quickly and intuitively resliced in real time at the body to narrow the gap between radiologic imaging and autopsy. CONCLUSION Our system is a potentially valuable tool for planning autopsies, showing findings to medical laypeople, and teaching CT anatomy, thus further closing the gap between radiology and forensic pathology.
Resumo:
PURPOSE To evaluate a low-cost, inertial sensor-based surgical navigation solution for periacetabular osteotomy (PAO) surgery without the line-of-sight impediment. METHODS Two commercial inertial measurement units (IMU, Xsens Technologies, The Netherlands), are attached to a patient's pelvis and to the acetabular fragment, respectively. Registration of the patient with a pre-operatively acquired computer model is done by recording the orientation of the patient's anterior pelvic plane (APP) using one IMU. A custom-designed device is used to record the orientation of the APP in the reference coordinate system of the IMU. After registration, the two sensors are mounted to the patient's pelvis and acetabular fragment, respectively. Once the initial position is recorded, the orientation is measured and displayed on a computer screen. A patient-specific computer model generated from a pre-operatively acquired computed tomography scan is used to visualize the updated orientation of the acetabular fragment. RESULTS Experiments with plastic bones (eight hip joints) performed in an operating room comparing a previously developed optical navigation system with our inertial-based navigation system showed no statistically significant difference on the measurement of acetabular component reorientation. In all eight hip joints the mean absolute difference was below four degrees. CONCLUSION Using two commercially available inertial measurement units we show that it is possible to accurately measure the orientation (inclination and anteversion) of the acetabular fragment during PAO surgery and therefore to successfully eliminate the line-of-sight impediment that optical navigation systems have.