Aurizon, Australia's largest freight railway operator, is investigating the use of Rail Power Conditioner (RPC) technology for load balancing, reactive power compensation and harmonic filtering. The new technology has the capability of replacing Static VAr Compensators (SVC) and Harmonic Filters, and is expected to have a significant impact on the overall costs of railway electrification. This paper presents the theoretical analysis of the real and reactive power flows in an RPC used to balance active powers in an existing V/V feeder station. This informed an RPC feasibility study undertaken at four existing Aurizon's feeder stations with V/V connected transformers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Wind power has grown fast internationally. It can reduce the environmental impact of energy production and increase energy security. Finland has turbine industry but wind electricity production has been slow, and nationally set capacity targets have not been met. I explored social factors that have affected the slow development of wind power in Finland by studying the perceptions of Finnish national level wind power actors. By that I refer to people who affect the development of wind power sector, such as officials, politicians, and representatives of wind industries and various organisations. The material consisted of interviews, a questionnaire, and written sources. The perceptions of wind power, its future, and methods to promote it were divided. They were studied through discourse analysis, content analysis, and scenario construction. Definition struggles affect views of the significance and potential of wind power in Finland, and also affect investments in wind power and wind power policy choices. Views of the future were demonstrated through scenarios. The views included scenarios of fast growth, but in the most pessimistic views, wind power was not thought to be competitive without support measures even in 2025, and the wind power capacity was correspondingly low. In such a scenario, policy tool choices were expected to remain similar to ones in use at the time of the interviews. So far, the development in Finland has followed closely this pessimistic scenario. Despite the scepticism about wind electricity production, wind turbine industry was seen as a credible industry. For many wind power actors as well as for the Finnish wind power policy, the turbine industry is a significant motive to promote wind power. Domestic electricity production and the export turbine industry are linked in discourse through so-called home market argumentation. Finnish policy tools have included subsidies, research and development funding, and information policies. The criteria used to evaluate policy measures were both process-oriented and value-based. Feed-in tariffs and green certificates that are common elsewhere have not been taken to use in Finland. Some interviewees considered such tools unsuitable for free electricity markets and for the Finnish policy style, dictatorial, and being against western values. Other interviewees supported their use because of their effectiveness. The current Finnish policy tools are not sufficiently effective to increase wind power production significantly. Marginalisation of wind power in discourses, pessimistic views of the future, and the view that the small consumer demand for wind electricity represents the political views of citizens towards promoting wind power, make it more difficult to take stronger policy measures to use. Wind power has not yet significantly contributed to the ecological modernisation of the energy sector in Finland, but the situation may change as the need to reduce emissions from energy production continues.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The deviation in the performance of active networks due to practical operational amplifiers (OA) is mainly because of the finite gain bandwidth productBand nonzero output resistanceR_0. The effect ofBandR_0on two OA impedances and single and multi-OA filters are discussed. In filters, the effect ofR_0is to add zeros to the transfer function often making it nonminimum phase. A simple method of analysis has been suggested for 3-OA biquad and coupled biquad circuits. A general method of noise minimization of the generalized impedance converter (GIC), while operating OA's within the prescribed voltage and current limits, is also discussed. The 3-OA biquadratic sections analyzed also exhibit noise behavior and signal handling capacity similar to the GIC. The GIC based structures are found to be better than other configurations both in biquadratic sections and direct realizations of higher order transfer functions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We obtained the images of the eastern part of the solar corona in the Fe xiv 530.3 nm (green) and Fe x 637.4 nm (red) coronal emission lines during the total solar eclipse of 29 March 2006 at Manavgat, Antalya, Turkey. The images were obtained using a 35 cm Meade telescope equipped with a Peltier-cooled 2k x 2k CCD and 0.3 nm pass-band interference filters at the rates of 2.95 s (exposure times of 100 ms) and 2.0 s (exposure times of 300 ms) in the Fe xiv and Fe x emission lines,respectively. The analysis of the data indicates intensity variations at some locations with period of strongest power around 27 s for the green line and 20 s for the red line. These results confirm earlier findings of variations in the continuum intensity with periods in the range of 5 to 56 s by Singh et al. (Solar Phys. 170, 235, 1997). The wavelet analysis has been used to identify significant intensity oscillations at all pixels within our field of view. Significant oscillations with high probability estimates were detected for some locations only. These locations seem to follow the boundary of an active region and in the neighborhood, rather than within the loops themselves. These intensity oscillations may be caused by fast magneto-sonic waves in the solar corona and partly account for heating of the plasma in the corona.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Dissolved Gas Analysis (DGA) a non destructive test procedure, has been in vogue for a long time now, for assessing the status of power and related transformers in service. An early indication of likely internal faults that may exist in Transformers has been seen to be revealed, to a reasonable degree of accuracy by the DGA. The data acquisition and subsequent analysis needs an expert in the concerned area to accurately assess the condition of the equipment. Since the presence of the expert is not always guaranteed, it is incumbent on the part of the power utilities to requisition a well planned and reliable artificial expert system to replace, at least in part, an expert. This paper presents the application of Ordered Ant Mner (OAM) classifier for the prediction of involved fault. Secondly, the paper also attempts to estimate the remaining life of the power transformer as an extension to the elapsed life estimation method suggested in the literature.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Laser mediated stimulation of biological process was amongst its very first effects documented by Mester et al. but the ambiguous and tissue-cell context specific biological effects of laser radiation is now termed ‘Photobiomodulation’. We found many parallels between the reported biological effects of lasers and a multiface-ted growth factor, Transforming Growth Factor-β (TGF-β). This review outlines the interestingparallelsbetween the twofieldsand our rationalefor pursuingtheir potential causal correlation. We explored this correlation using an in vitro assay systems and a human clinical trial on healing wound extraction sockets that we reported in a recent publication. In conclusion we report that low power laser irradiation can activate latent TGF-β1 and β3 complexes and suggest that this might be one of the major modes of the photobiomodulatory effects of low power lasers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study of symbolic power relations in a transnational merger, we suggest that the popular media can provide a significant arena for (re)constructing national identities and power in this kind of dramatic industrial restructuring, and are an under-utilized source of empirical data in research studies. Focusing on the press coverage of a recent Swedish-Finnish merger, we specify and illustrate a particular feature of discursive (re)construction of asymmetric power relations; superior (Swedish) and inferior (Finnish) national identities, which, we argue, are embedded in the history of colonization and domination between the two nations. The findings of the present study lead us to suggest that a lens taken from post-colonial theory is particularly useful in understanding the wider symbolic power implications of international industrial restructuring.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes an approach for the analysis and design of 765kV/400kV EHV transmission system which is a typical expansion in Indian power grid system, based on the analysis of steady state and transient over voltages. The approach for transmission system design is iterative in nature. The first step involves exhaustive power flow analysis, based on constraints such as right of way, power to be transmitted, power transfer capabilities of lines, existing interconnecting transformer capabilities etc. Acceptable bus voltage profiles and satisfactory equipment loadings during all foreseeable operating conditions for normal and contingency operation are the guiding criteria. Critical operating strategies are also evolved in this initial design phase. With the steady state over voltages obtained, comprehensive dynamic and transient studies are to be carried out including switching over voltages studies. This paper presents steady state and switching transient studies for alternative two typical configurations of 765kV/400 kV systems and the results are compared. Transient studies are carried out to obtain the peak values of 765 kV transmission systems and are compared with the alternative configurations of existing 400 kV systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bootstrap likelihood ratio tests of cointegration rank are commonly used because they tend to have rejection probabilities that are closer to the nominal level than the rejection probabilities of the correspond- ing asymptotic tests. The e¤ect of bootstrapping the test on its power is largely unknown. We show that a new computationally inexpensive procedure can be applied to the estimation of the power function of the bootstrap test of cointegration rank. The bootstrap test is found to have a power function close to that of the level-adjusted asymp- totic test. The bootstrap test estimates the level-adjusted power of the asymptotic test highly accurately. The bootstrap test may have low power to reject the null hypothesis of cointegration rank zero, or underestimate the cointegration rank. An empirical application to Euribor interest rates is provided as an illustration of the findings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An attempt to diagnose the dominant forcings which drive the large-scale vertical velocities over the monsoon region has been made by computing the forcings like diabatic heating fields,etc. and the large-scale vertical velocities driven by these forcings for the contrasting periods of active and break monsoon situations; in order to understand the rainfall variability associated with them. Computation of diabatic heating fields show us that among different components of diabatic heating it is the convective heating that dominates at mid-tropospheric levels during an active monsoon period; whereas it is the sensible heating at the surface that is important during a break period. From vertical velocity calculations we infer that the prime differences in the large-scale vertical velocities seen throughout the depth of the atmosphere are due to the differences in the orders of convective heating; the maximum rate of latent heating being more than 10 degrees Kelvin per day during an active monsoon period; whereas during a break monsoon period it is of the order of 2 degrees Kelvin per day at mid-tropospheric levels. At low levels of the atmosphere, computations show that there is large-scale ascent occurring over a large spatial region, driven only by the dynamic forcing associated with vorticity and temperature advection during an active monsoon period. However, during a break monsoon period such large-scale spatial organization in rising motion is not seen. It is speculated that these differences in the low-level large-scale ascent might be causing differences in convective heating because the weaker the low level ascent, the lesser the convective instability which produces deep cumulus clouds and hence lesser the associated latent heat release. The forcings due to other components of diabatic heating, namely, the sensible heating and long wave radiative cooling do not influence the large-scale vertical velocities significantly.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, we suggest criteria for the identification of active and break events of the Indian summer monsoon on the basis of recently derived high resolution daily gridded rainfall dataset over India (1951-2007). Active and break events are defined as periods during the peak monsoon months of July and August, in which the normalized anomaly of the rainfall over a critical area, called the monsoon core zone exceeds 1 or is less than -1.0 respectively, provided the criterion is satisfied for at least three consecutive days. We elucidate the major features of these events. We consider very briefly the relationship of the intraseasonal fluctuations between these events and the interannual variation of the summer monsoon rainfall. We find that breaks tend to have a longer life-span than active spells.While, almost 80% of the active spells lasted 3-4 days, only 40% of the break spells were of such short duration. A small fraction (9%) of active spells and 32% of break spells lasted for a week or longer. While active events occurred almost every year, not a single break occurred in 26% of the years considered. On an average, there are 7 days of active and break events from July through August. There are no significant trends in either the days of active or break events. We have shown that there is a major difference between weak spells and long intense breaks. While weak spells are characterized by weak moist convective regimes, long intense break events have a heat trough type circulation which is similar to the circulation over the Indian subcontinent before the onset of the monsoon. The space-time evolution of the rainfall composite patterns suggests that the revival from breaks occurs primarily from northward propagations of the convective cloud zone. There are important differences between the spatial patterns of the active/break spells and those characteristic of interannual variation, particularly those associated with the link to ENSO. Hence, the interannual variation of the Indian monsoon cannot be considered as primarily arising from the interannual variation of intraseasonal variation. However, the signature over the eastern equatorial Indian Ocean on intraseasonal time scales is similar to that on the interannual time scales.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Energy-based direct methods for transient stability analysis are potentially useful both as offline tools for planning purposes as well as for online security assessment. In this paper, a novel structure-preserving energy function (SPEF) is developed using the philosophy of structure-preserving model for the system and detailed generator model including flux decay, transient saliency, automatic voltage regulator (AVR), exciter and damper winding. A simpler and yet general expression for the SPEF is also derived which can simplify the computation of the energy function. The system equations and the energy function are derived using the centre-of-inertia (COI) formulation and the system loads are modelled as arbitrary functions of the respective bus voltages. Application of the proposed SPEF to transient stability evaluation of power systems is illustrated with numerical examples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An application of direct methods to dynamic security assessment of power systems using structure-preserving energy functions (SPEF) is presented. The transient energy margin (TEM) is used as an index for checking the stability of the system as well as ranking the contigencies based on their severity. The computation of the TEM requires the evaluation of the critical energy and the energy at fault clearing. Usually this is done by simulating the faulted trajectory, which is time-consuming. In this paper, a new algorithm which eliminates the faulted trajectory estimation is presented to calculate the TEM. The system equations and the SPEF are developed using the centre-of-inertia (COI) formulation and the loads are modelled as arbitrary functions of the respective bus voltages. The critical energy is evaluated using the potential energy boundary surface (PEBS) method. The method is illustrated by considering two realistic power system examples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A study of radio intensity variations at seven frequencies in the range 0.3 to 90 GHz for compact extragalactic radio sources classified as BL Lacs and high- and low-optical polarization quasars (HPQs and LPQs) is presented. This include the results of flux-density monitoring of 33 compact sources for three years at 327 MHz with the Ooty Synthesis Radio Telescope. The degrees of 'short-term' (tau less than about 1 yr) variability for the three optical types are found to be indistinguishable at low frequencies (less than 1 GHz), pointing to an extrinsic origin for the low-frequency variability. At high frequencies, a distinct dependence on optical type is present, the variability increasing from LPQs, through HPQs to BL Lacs. This trend persists even when only sources with ultra-flat radio spectra (alpha greater than -0.2) are considered. Implications of this for the phenomenon of high-frequency variability and the proposed unification schemes for different optical types of active galactic nuclei are discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper proposes a method of sharing power/energy between multiple sources and multiple loads using an integrated magnetic circuit as a junction between sources and sinks. It also presents a particular use of the magnetic circuit as an ac power supply, delivering sinusoidal voltage to load irrespective of the presence of the grid, taking only active power from the grid. The proposed magnetic circuit is a three-energy-port unit, viz.: 1) power/energy from grid; 2) power energy from battery-inverter unit; and 3) power/energy delivery to the load in its particular application as quality ac power supply (QPS). The product provides sinusoidal regulated output voltage, input power-factor correction, electrical isolation between the sources and loads, low battery voltage, and control simplicity. Unlike conventional series-shunt-compensated uninterruptible power supply topologies with low battery voltage, the isolation is provided using a single magnetic circuit that results in a smaller size and lower cost. The circuit operating principles and analysis, as well as simulation and experimental results, are presented for this QPS.