926 resultados para Radionuklidgenerator, Ga-68, Sc-44, PET
Resumo:
Background - Iris cysts in children are uncommon and there is relatively little information on their classification, incidence, and management. Methods - The records of all children under age 20 years who were diagnosed with iris cyst were reviewed and the types and incidence of iris cysts of childhood determined. Based on these observations recommendations were made regarding management of iris cysts in children. Results - Of 57 iris cysts in children, 53 were primary and four were secondary. There were 44 primary cysts of the iris pigment epithelium, 34 of which were of the peripheral or iridociliary type, accounting for 59% of all childhood iris cysts. It was most commonly diagnosed in the teenage years, more common in girls (68%), was not recognised in infancy, remained stationary or regressed, and required no treatment. The five mid-zonal pigment epithelial cysts were diagnosed at a mean age of 14 years, were more common in boys (83%), remained stationary, and required no treatment. The pupillary type of pigment epithelial cyst was generally recognised in infancy and, despite involvement of the pupillary aperture, also required no treatment. There were nine cases of primary iris stromal cysts, accounting for 16% of all childhood iris cysts. This cyst was usually diagnosed in infancy, was generally progressive, and required treatment in eight of the nine cases, usually by aspiration and cryotherapy or surgical resection. Among the secondary iris cysts, two were post-traumatic epithelial ingrowth cysts and two were tumour induced cysts, one arising from an intraocular lacrimal gland choristoma and one adjacent to a peripheral iris naevus. Conclusions - Most iris cysts of childhood are primary pigment epithelial cysts and require no treatment. However, the iris stromal cyst, usually recognised in infancy, is generally an aggressive lesion that requires treatment by aspiration or surgical excision.
Resumo:
Boundary layer transition estimation and modelling is essential for the design of many engineering products across many industries. In this paper, the Reynolds-averaged Navier–Stokes are solved in conjunction with three additional transport equations to model and predict boundary layer transition. The transition model (referred to as the kTkT–kLkL–ωω model) is based on the kk–ωω framework with an additional transport equation to incorporate the effects low-frequency flow oscillations in the form of a laminar kinetic energy (kLkL). Firstly, a number of rectifications are made to the original kTkT–kLkL–ωω framework in order to ensure an appropriate response to the free-stream turbulence level and to improve near wall predictions. Additionally, the model is extended to incorporate the capability to model transition due to surface irregularities in the form of backward-facing steps with maximum non-dimensional step sizes of approximately 1.5 times the local displacement thickness of the boundary layer where the irregularity is located (i.e k/δ∗⪅1.5k/δ∗⪅1.5) at upstream turbulence intensities in the range 0.01<Tu(%)<0.80.01<Tu(%)<0.8. A novel function is proposed to incorporate transition sensitivity due to aft-facing steps. This paper details the rationale behind the development of this new function and demonstrates its suitability for transition onset estimation on a flat plate at zero pressure gradient.
Resumo:
Introduction
PET-computed tomography (PET-CT) is a useful staging imaging modality in colorectal liver metastases (CRLM). This study aimed to determine whether PET-CT parameters, standardized uptake value (SUV) and reconstructed tumour volume (RTV), are predictors of prognosis and survival.
Methods
A study of all resectable CRLM patients in the regional HPB unit from 2007–2009 was performed. Preoperative PET-CT scans were retrospectively reviewed; SUV, diameter and RTV for each lesion was recorded. Correlation analysis was performed with other pathological and biochemical parameters, by Pearson’s correlation analysis. Survival analysis was performed using Cox regression hazard model. A P value of less than 0.05 was considered statistically significant.
Results
A total of 79 patients were included. SUV moderately correlated with tumour diameter, both PET-CT (r=0.4927; P<0.0001) and histology (r=0.4513; P=0.0003); RTV (r=0.4489; P<0.001), preoperative carcinoembryonic antigen (CEA) (r=0.4977; P=0.0001), and postoperative CEA (r=0.3727; P=0.004). Multivariate analysis found that an independent predictor of SUVmax was preoperative CEA (P=0.03). RTV strongly correlated with preoperative CEA (r=0.9389; P<0.0001). SUV and RTV had a negative effect on survival.
Conclusion
PET-CT, in the setting of CRLM, may have a prognostic role in assessing survival. Although no definite conclusions can be drawn regarding the prognostic role of SUV and RTV, it acts to reinforce the need for further prospective studies to validate these findings.
Resumo:
The fluorophore-spacer1-receptor1-spacer2-receptor2 system (where receptor2 alone is photoredox-inactive) shows ionically tunable proton-induced fluorescence off-on switching, which is reminiscent of thermionic triode behavior. This also represents a new extension to modular switch systems based on photoinduced electron transfer (PET) towards the emulation of analogue electronic devices.
Resumo:
In this work we report on the evaluation of electron-impact collision strengths and Maxwellian averaged effective collision strengths for the lowly-ionized Fe-peak elements Sc II and Ti II using the parallel R-matrix package RMATRX II.
Resumo:
Background: Patient reported outcome measures (PROMs) are used to evaluate lifestyle interventions but littleis known about differences between patients returning valid and invalid responses, or of potential for bias inevaluations. We aimed to examine the characteristics of patients who returned valid responses to lifestylequestionnaires compared to those whose responses were invalid for evaluating lifestyle change.
Methods: We conducted a secondary data analysis from the SPHERE Study, a trial of an intervention to improveoutcomes for patients with coronary heart disease in primary care. Postal questionnaires were used to assessphysical activity (Godin) and diet (DINE) among study participants at baseline and 18 month follow-up. Three binaryresponse variables were generated for analysis: (1) valid Godin score; (2) valid DINE Fibre score; and (3) validDINE Total Fat score. Multivariate analysis comprised generalised estimating equation regression to examine theassociation of patients’ characteristics with their return of valid responses at both timepoints.
Results: Overall, 92.1% of participants (832/903) returned questionnaires at both baseline and 18 months. Relativelyfewer valid Godin scores were returned by those who left school aged <15 years (36.5%) than aged 18 and over(50.5%), manual workers (39.5%) than non-manual (49.5%) and those with an elevated cholesterol (>5 mmol)(34.7%) than those with a lower cholesterol (44.4%) but multivariate analysis identified that only school leaving age(p = 0.047) was of statistical significance.Relatively fewer valid DINE scores were returned by manual than non-manual workers (fibre: 80.8% v 86.8%;fat: 71.2% v 80.0%), smokers (fibre: 72.6% v 84.7%; fat: 67.5% v 76.9%), patients with diabetes (fibre: 75.9% v 82.9%;fat: 66.9% v 75.8%) and those with cholesterol >5 mmol (fat: 68.2% v 76.2%) but multivariate analysis showedstatistical significance only for smoking (fibre: p = 0.013; fat: p = 0.045), diabetes (fibre: p = 0.039; fat: p = 0.047), andcholesterol (fat: p = 0.039).
Conclusions: Our findings illustrate the importance of detailed reporting of research methods, with clearinformation about response rates, respondents and valid outcome data. Outcome measures which are relevant to astudy population should be chosen carefully. The impact of methods of outcome measurement and valid responserates in evaluating healthcare requires further study.
Resumo:
The surface structure of the clean Co{1010BAR} surface and a c(2 x 2) potassium overlayer have been determined by quantitative low energy electron diffraction. The Co{1010BAR} sample has been shown to be laterally unreconstructed with the surface being uniquely terminated by an outermost closely packed double layer (dz12 = 0.68 angstrom). A damped oscillatory relaxation of the outermost three atomic layers occurs, with relaxations DELTA-dz12 = -6.5 +/- 2% and DELTA-dz23 = +1.0 +/- 2%.
The c(2 x 2) overlayer formed at a coverage of 0.5 ML was subjected to a full I-V analysis. A range of adsorption sites were tested including fourfold hollow, on-top, and both long and short bridge sites in combination with both "long" and "short" cobalt interlayer terminations. A clear preference was found for adsorption in the maximal coordination fourfold hollow site. No switching of surface termination occurs. The potassium adatoms reside in the [1210BAR] surface channels directly above second layer cobalt atoms with a potassium to outermost cobalt interlayer separation of 2.44 +/- 0.05 angstrom. Potassium-cobalt bond lengths of 3.40 +/- 0.05 and 3.12 +/- 0.05 angstrom between the four (one) outermost (second) layer nearest-neighbour substrate atoms suggests a potassium effective radius of 1.87 +/- 0.05 angstrom, somewhat smaller than the Pauling covalent radius and considerably larger than the ionic radius (1.38 angstrom). The alkali-surface bonding is thus predominantly "covalent"/"metallic".
Resumo:
This document describes best practice and evidence based recommendations for the use of FDG-PET/CT for the purposes of radiotherapy target volume delineation (TVD) for curative intent treatment of non-small cell lung cancer (NSCLC). These recommendations have been written by an expert advisory group, convened by the International Atomic Energy Agency (IAEA) to facilitate a Coordinated Research Project (CRP) aiming to improve the applications of PET based radiation treatment planning (RTP) in low and middle income countries. These guidelines can be applied in routine clinical practice of radiotherapy TVD, for NSCLC patients treated with concurrent chemoradiation or radiotherapy alone, where FDG is used, and where a calibrated PET camera system equipped for RTP patient positioning is available. Recommendations are provided for PET and CT image visualization and interpretation, and for tumor delineation using planning CT with and without breathing motion compensation.
Resumo:
We report calculations of energy levels, radiative rates and electron impact excitation cross sections and rates for transitions in He-like Ga XXX, Ge XXXI, As XXXII, Se XXXIII and Br XXXIV. The grasp (general-purpose relativistic atomic structure package) is adopted for calculating energy levels and radiative rates. For determining the collision strengths, and subsequently the excitation rates, the Dirac atomic R-matrix code (darc) is used. Oscillator strengths, radiative rates and line strengths are reported for all E1, E2, M1 and M2 transitions among the lowest 49 levels of each ion. Additionally, theoretical lifetimes are provided for all 49 levels of the above five ions. Collision strengths are averaged over a Maxwellian velocity distribution and the effective collision strengths obtained listed over a wide temperature range up to 108 K. Comparisons are made with similar data obtained using the flexible atomic code (fac) to highlight the importance of resonances, included in calculations with darc, in the determination of effective collision strengths. Discrepancies between the collision strengths from darc and fac, particularly for some forbidden transitions, are also discussed. Finally, discrepancies between the present results for effective collision strengths with the darc code and earlier semi-relativistic R-matrix data are noted over a wide range of electron temperatures for many transitions in all ions. © 2013 The Royal Swedish Academy of Sciences.
Resumo:
The two families of fluorescent PET (photoinduced electron transfer) sensors (1-9) show that the effective proton density near the surface of several micelle membranes changes over 2-3 orders of magnitude as the microlocation of the sensor (with respect to the membrane) is altered via hydrophobic tuning.