967 resultados para Pulsating Fluid-flow
Resumo:
A specific modified constitutive equation for a third-grade fluid is proposed so that the model be suitable for applications where shear-thinning or shear-thickening may occur. For that, we use the Cosserat theory approach reducing the exact three-dimensional equations to a system depending only on time and on a single spatial variable. This one-dimensional system is obtained by integrating the linear momentum equation over the cross-section of the tube, taking a velocity field approximation provided by the Cosserat theory. From this reduced system, we obtain the unsteady equations for the wall shear stress and mean pressure gradient depending on the volume flow rate, Womersley number, viscoelastic coefficient and flow index over a finite section of the tube geometry with constant circular cross-section.
Resumo:
In this study, the lubrication theory is used to model flow in geological fractures and analyse the compound effect of medium heterogeneity and complex fluid rheology. Such studies are warranted as the Newtonian rheology is adopted in most numerical models because of its ease of use, despite non-Newtonian fluids being ubiquitous in subsurface applications. Past studies on Newtonian and non-Newtonian flow in single rock fractures are summarized in Chapter 1. Chapter 2 presents analytical and semi-analytical conceptual models for flow of a shear-thinning fluid in rock fractures having a simplified geometry, providing a first insight on their permeability. in Chapter 3, a lubrication-based 2-D numerical model is first implemented to solve flow of an Ellis fluid in rough fractures; the finite-volumes model developed is more computationally effective than conducting full 3-D simulations, and introduces an acceptable approximation as long as the flow is laminar and the fracture walls relatively smooth. The compound effect of shear-thinning fluid nature and fracture heterogeneity promotes flow localization, which in turn affects the performance of industrial activities and remediation techniques. In Chapter 4, a Monte Carlo framework is adopted to produce multiple realizations of synthetic fractures, and analyze their ensemble statistics pertaining flow for a variety of real non-Newtonian fluids; the Newtonian case is used as a benchmark. In Chapter 5 and Chapter 6, a conceptual model of the hydro-mechanical aspects of backflow occurring in the last phase of hydraulic fracturing is proposed and experimentally validated, quantifying the effects of the relaxation induced by the flow.
Resumo:
Using Computational Wind Engineering, CWE, for solving wind-related problems is still a challenging task today, mainly due to the high computational cost required to obtain trustworthy simulations. In particular, the Large Eddy Simulation, LES, has been widely used for evaluating wind loads on buildings. The present thesis assesses the capability of LES as a design tool for wind loading predictions through three cases. The first case is using LES for simulating the wind field around a ground-mounted rectangular prism in Atmospheric Boundary Layer (ABL) flow. The numerical results are validated with experimental results for seven wind attack angles, giving a global understanding of the model performance. The case with the worst model behaviour is investigated, including the spatial distribution of the pressure coefficients and their discrepancies with respect to experimental results. The effects of some numerical parameters are investigated for this case to understand their effectiveness in modifying the obtained numerical results. The second case is using LES for investigating the wind effects on a real high-rise building, aiming at validating the performance of LES as a design tool in practical applications. The numerical results are validated with the experimental results in terms of the distribution of the pressure statistics and the global forces. The mesh sensitivity and the computational cost are discussed. The third case is using LES for studying the wind effects on the new large-span roof over the Bologna stadium. The dynamic responses are analyzed and design envelopes for the structure are obtained. Although it is a numerical simulation before the traditional wind tunnel tests, i.e. the validation of the numerical results are not performed, the preliminary evaluations can effectively inform later investigations and provide the final design processes with deeper confidence regarding the absence of potentially unexpected behaviours.
Resumo:
In this thesis, the viability of the Dynamic Mode Decomposition (DMD) as a technique to analyze and model complex dynamic real-world systems is presented. This method derives, directly from data, computationally efficient reduced-order models (ROMs) which can replace too onerous or unavailable high-fidelity physics-based models. Optimizations and extensions to the standard implementation of the methodology are proposed, investigating diverse case studies related to the decoding of complex flow phenomena. The flexibility of this data-driven technique allows its application to high-fidelity fluid dynamics simulations, as well as time series of real systems observations. The resulting ROMs are tested against two tasks: (i) reduction of the storage requirements of high-fidelity simulations or observations; (ii) interpolation and extrapolation of missing data. The capabilities of DMD can also be exploited to alleviate the cost of onerous studies that require many simulations, such as uncertainty quantification analysis, especially when dealing with complex high-dimensional systems. In this context, a novel approach to address parameter variability issues when modeling systems with space and time-variant response is proposed. Specifically, DMD is merged with another model-reduction technique, namely the Polynomial Chaos Expansion, for uncertainty quantification purposes. Useful guidelines for DMD deployment result from the study, together with the demonstration of its potential to ease diagnosis and scenario analysis when complex flow processes are involved.
Resumo:
Rapidity-odd directed flow (v1) measurements for charged pions, protons, and antiprotons near midrapidity (y=0) are reported in sNN=7.7, 11.5, 19.6, 27, 39, 62.4, and 200 GeV Au+Au collisions as recorded by the STAR detector at the Relativistic Heavy Ion Collider. At intermediate impact parameters, the proton and net-proton slope parameter dv1/dy|y=0 shows a minimum between 11.5 and 19.6 GeV. In addition, the net-proton dv1/dy|y=0 changes sign twice between 7.7 and 39 GeV. The proton and net-proton results qualitatively resemble predictions of a hydrodynamic model with a first-order phase transition from hadronic matter to deconfined matter, and differ from hadronic transport calculations.
Resumo:
Response surface methodology based on Box-Behnken (BBD) design was successfully applied to the optimization in the operating conditions of the electrochemical oxidation of sanitary landfill leachate aimed for making this method feasible for scale up. Landfill leachate was treated in continuous batch-recirculation system, where a dimensional stable anode (DSA(©)) coated with Ti/TiO2 and RuO2 film oxide were used. The effects of three variables, current density (milliampere per square centimeter), time of treatment (minutes), and supporting electrolyte dosage (moles per liter) upon the total organic carbon removal were evaluated. Optimized conditions were obtained for the highest desirability at 244.11 mA/cm(2), 41.78 min, and 0.07 mol/L of NaCl and 242.84 mA/cm(2), 37.07 min, and 0.07 mol/L of Na2SO4. Under the optimal conditions, 54.99 % of chemical oxygen demand (COD) and 71.07 ammonia nitrogen (NH3-N) removal was achieved with NaCl and 45.50 of COD and 62.13 NH3-N with Na2SO4. A new kinetic model predicted obtained from the relation between BBD and the kinetic model was suggested.
Resumo:
Infections of the central nervous systems (CNS) present a diagnostic problem for which an accurate laboratory diagnosis is essential. Invasive practices, such as cerebral biopsy, have been replaced by obtaining a polymerase chain reaction (PCR) diagnosis using cerebral spinal fluid (CSF) as a reference method. Tests on DNA extracted from plasma are noninvasive, thus avoiding all of the collateral effects and patient risks associated with CSF collection. This study aimed to determine whether plasma can replace CSF in nested PCR analysis for the detection of CNS human herpesvirus (HHV) diseases by analysing the proportion of patients whose CSF nested PCR results were positive for CNS HHV who also had the same organism identified by plasma nested PCR. In this study, CSF DNA was used as the gold standard, and nested PCR was performed on both types of samples. Fifty-two patients with symptoms of nervous system infection were submitted to CSF and blood collection. For the eight HHV, one positive DNA result-in plasma and/or CSF nested PCR-was considered an active HHV infection, whereas the occurrence of two or more HHVs in the same sample was considered a coinfection. HHV infections were positively detected in 27/52 (51.9%) of the CSF and in 32/52 (61.5%) of the plasma, difference not significant, thus nested PCR can be performed on plasma instead of CSF. In conclusion, this findings suggest that plasma as a useful material for the diagnosis of cases where there is any difficulty to perform a CSF puncture.
Resumo:
We reported here for the first time that triboelectric charges on PET sheets can be used to seal and control the flow rate in paper-based devices. The proposed method exhibits simplicity and low cost, provides reversible sealing and minimizes the effect of sample evaporation.
Resumo:
Chemokines may contribute to local and systemic inflammation in patients with psoriasis. Previous studies have demonstrated the importance of chemokine ligands and receptors in the recruitment of T cells into psoriatic lesional skin and synovial fluid. The aim of this study was to evaluate the levels of Th1-related chemokines in psoriasis and to investigate any association with disease severity. We quantified serum levels of CXCL9, CXCL10 and CXCL16 and the frequencies of CD4+CXCR3+ T lymphocytes through ELISA and flow cytometry, respectively. A total of 38 patients with psoriasis and 33 controls were included. There were no significant differences in chemokine levels between psoriasis and control groups. Patients with psoriatic arthritis had lower median level of CXCL10 when compared with controls (p=0.03). There were no significant correlations between serum chemokines analyzed and disease severity. Frequencies of CD4+CXCR3+ T cells were lower in patients with psoriasis than in controls (p<0.01). A sensitivity analysis excluding patients on systemic therapy yielded similar results. Serum concentrations of CXCL9, CXCL10 and CXCL16 were not increased in the psoriasis group or correlated with disease severity. Systemic levels of chemokine ligands do not seem to be sensitive biomarkers of disease activity or accurate parameters to predict response to therapy. Frequencies of CD4+CXCR3+ T cells were decreased in the peripheral blood of psoriasis patients, possibly due to recruitment to inflammatory lesions.
Resumo:
The aim of this present study was to investigate on the effects of concurrent training with blood flow restriction (BFR-CT) and concurrent training (CT) on the aerobic fitness, muscle mass and muscle strength in a cohort of older individuals. 25 healthy older adults (64.7±4.1 years; 69.33±10.8 kg; 1.6±0.1 m) were randomly assigned to experimental groups: CT (n=8, endurance training (ET), 2 days/week for 30-40 min, 50-80% VO2peak and RT, 2 days/week, leg press with 4 sets of 10 reps at 70-80% of 1-RM with 60 s rest), BFR-CT (n=10, ET, similar to CT, but resistance training with blood flow restriction: 2 days/week, leg press with 1 set of 30 and 3 sets of 15 reps at 20-30% 1-RM with 60 s rest) or control group (n=7). Quadriceps cross-sectional area (CSAq), 1-RM and VO2peak were assessed pre- and post-examination (12 wk). The CT and BFR-CT showed similar increases in CSAq post-test (7.3%, P<0.001; 7.6%, P<0.0001, respectively), 1-RM (38.1%, P<0.001; 35.4%, P=0.001, respectively) and VO2peak (9.5%, P=0.04; 10.3%, P=0.02, respectively). The BFR-CT promotes similar neuromuscular and cardiorespiratory adaptations as CT.
Resumo:
Nitric oxide (NO)-mediated vasodilation plays a key role in gastric mucosal defense, and NO-donor drugs may protect against diseases associated with gastric mucosal blood flow (GMBF) deficiencies. In this study, we used the ex vivo gastric chamber method and Laser Doppler Flowmetry to characterize the effects of luminal aqueous NO-donor drug S-nitroso-N-acetylcysteine (SNAC) solution administration compared to aqueous NaNO2 and NaNO3 solutions (pH 7.4) on GMBF in Sprague-Dawley rats. SNAC solutions (600 μM and 12 mM) led to a rapid threefold increase in GMBF, which was maintained during the incubation of the solutions with the gastric mucosa, while NaNO2 or NaNO3 solutions (12 mM) did not affect GMBF. SNAC solutions (600 μM and 12 mM) spontaneously released NO at 37 °C at a constant rate of 0.3 or 14 nmol·mL-1·min-1, respectively, while NaNO2 (12 mM) released NO at a rate of 0.06 nmol·mL-1·min-1 and NaNO3 (12 mM) did not release NO. These results suggest that the SNAC-induced GMBF increase is due to their higher rates of spontaneous NO release compared to equimolar NaNO2 solutions. Taken together, our data indicate that oral SNAC administration is a potential approach for gastric acid-peptic disorder prevention and treatment.
Resumo:
A flow injection method for the quantitative analysis of ketoconazole in tablets, based on the reaction with iron (III) ions, is presented. Ketoconazole forms a red complex with iron ions in an acid medium, with maximum absorbance at 495 nm. The detection limit was estimated to be 1×10--4 mol L-1; the quantitation limit is about 3×10--4 mol L-1 and approximately 30 determinations can be performed in an hour. The results were compared with those obtained with a reference HPLC method. Statistical comparisons were done using the Student's t procedure and the F test. Complete agreement was found at the 0.95 significance level between the proposed flow injection and the HPLC procedures. The two methods present similar precision, i.e., for HPLC the mean relative standard deviation was ca. 1.2% and for FIA ca. 1.6%.
Resumo:
Broccoli seeds were coated in a conical-cylindrical spouted bed with an aqueous suspension of hydroxy ethyl cellulose aiming to improve the seeds coating technique using a fluid-dynamic process. An experimental design was applied to investigate the effects of the operating variables: gas temperature, atomizing air pressure and suspension flow rate on the germination of the seeds and on the process efficiency. Results indicated that the operating variables affect both the coating process efficiency and the germination ability. However, the analysis didn t identify differences between the germination potential of coated and uncoated seeds. Coated seeds absorbed up to 10 percent less moisture than the uncoated ones, when the environment temperature and humidity were controlled over a period of time.
Resumo:
The spouted and fluidized bed technologies are usually employed in operations of drying, coating and granulation of particles by the chemical and pharmaceutical industries. The use of these techniques in agronomy is limited to the treatment of some species of seeds. In this work, the objective was to analyse the fluid-dynamics of fluidized and spouted beds when broccoli (Brassica oleracea L. var. Italica) seeds are used and also to verify the influence on seed germination after 60 min of seed exposition to spouting or fluidization, at room temperature. The fluid-dynamics was defined by the measurements of the bed pressure drop as a function of the air flow rate for different seeds loads. The experimental conditions were based on the physical properties of the seeds and were limited by the apparatus dimensions. The cone-cylindrical bed was constructed in plexyglass to permit flow visualization. The values of the parameters: maximum pressure drop, minimum spouting flow rate and pressure drop, and stable spout pressure drop were experimentally obtained from the fluid-dynamic analysis and were compared with the values calculated by empirical equations found in the literature. The same procedure was carried out with the fluidized bed and the important parameters for this regime were the air velocity and the bed pressure drop at minimum fluidization. The analysis of seed germination indicated that no damage was caused to the seeds by the spout or fluidization processes.
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física