993 resultados para Power Doppler ultrasound


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We reviewed ultrasound features in patients with schistosomiasis mansoni. The alterations that we observed in acute and hepatosplenic schistosomiasis are described. The advantages and disadvantages of using ultrasound patterns in the evaluation of liver fibrosis are discussed. Other diseases that are important in the differential diagnosis of schistosomal liver fibrosis are presented. Ultrasound is an effective and flexible diagnostic tool in the evaluation of a variety of diseases. It presents no harmful effects to patients, allowing non-invasive studies in hospitalized patients and in other facilities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fault location has been studied deeply for transmission lines due to its importance in power systems. Nowadays the problem of fault location on distribution systems is receiving special attention mainly because of the power quality regulations. In this context, this paper presents an application software developed in Matlabtrade that automatically calculates the location of a fault in a distribution power system, starting from voltages and currents measured at the line terminal and the model of the distribution power system data. The application is based on a N-ary tree structure, which is suitable to be used in this application due to the highly branched and the non- homogeneity nature of the distribution systems, and has been developed for single-phase, two-phase, two-phase-to-ground, and three-phase faults. The implemented application is tested by using fault data in a real electrical distribution power system

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To test the ability of a novel phase-shifting medium (PSM) to provide sustained distension of the uterine cavity and produce saline infusion sonography (SIS)-like images in a simplified contrast ultrasound procedure. DESIGN: Prospective pilot feasibility trial of a new diagnostic procedure, contrast ultrasound. SETTING: Clinical reproductive endocrine and infertility unit of regional teaching hospital. PATIENT(S): Twenty-six asymptomatic infertile women (group I) and 27 women presenting with dysfunctional uterine bleeding (DUB) who were scheduled for exploratory surgery (group II). INTERVENTION(S): All women who were temporarily on oral contraceptive first had a regular pelvic ultrasound followed by the intrauterine instillation of up to 3 mL PSM, using a regular insemination catheter, after which all instruments were removed and a regular ultrasound was performed again. RESULT(S): In all 53 women, intrauterine instillation of 1-3 mL PSM resulted in a 3-7 mm uterine distension, sufficient to produce SIS-like images of the uterine cavity that lasted 7-10 min. Contrast ultrasound revealed an endometrial polyp in 3 asymptomatic women of group I. In group II. 12 of 14 women (86%) whose vaginal ultrasound were positive or dubious had positive findings with contrast ultrasound; 9 of 12 patients whose vaginal ultrasounds were negative also had positive contrast ultrasound findings. All the positive and negative findings of contrast ultrasound made in group II were confirmed anatomically (sensitivity and specificity of 100%), whereas the correlation for standard vaginal ultrasound was markedly lower at 57.1% and 85.7%, respectively. Most patients (46 of 53) reported no discomfort during or after the procedure, and 7 women described the procedure as mildly uncomfortable. CONCLUSION(S): Contrast ultrasound, a novel simple diagnostic procedure conducted after intrauterine instillation of 1-3 mL PSM using a simple plastic catheter, delivered SIS-quality images in asymptomatic (group I) and symptomatic (group II) patients while retaining the simplicity of standard ultrasound. We therefore foresee broad application of contrast ultrasound for sensitive and specific assessment for uterine pathologies in the physician's office.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, the authors review the literature and share their experience of the principal biological markers of fibrosis for the evaluation of periportal fibrosis (PPF) caused by mansoni schistosomiasis. These biological markers are compared to diagnostic ultrasound (US) scans as means of grading PPF. We also review procollagen type I and III, collagen type IV, laminin, hyaluronic acid (HA), immunoglobulin G, platelets, aspartate aminotransferase to platelet ratio index (APRI) and gamma-glutamyl transpeptidase as markers of the disease. Although there are several good markers for evaluating PPF and portal hypertension, such as HA, platelets or APRI, none can yet replace US. These markers may, however, be used to identify patients at greater risk of developing advanced disease in endemic areas and determine who will need further care and US studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Extension of retinoblastoma cells into the posterior chamber is a criterion for group E according to the international classification of intraocular retinoblastoma. Currently, the anterior extension of retinoblastoma is based on the presence of tumour cells in the anterior chamber assessed by biomicroscopy. AIM: To determine the value of ultrasound biomicroscopy (UBM) in the assessment of posterior chamber involvement in advanced retinoblastoma. METHODS: Retrospective review of all retinoblastoma cases enucleated at the Jules Gonin Eye Hospital from January 1996 to December 2009 for which UBM (35 MHz) evaluation was available. The patients' records were reviewed for patient and tumour features and histopathological findings. UBM findings were compared with histopathological features. RESULTS: UBM documentation was available in 31 cases. Retinoblastoma was detected by UBM in the posterior chamber in 18 cases and was absent in 13 cases while histopathological analysis demonstrated its presence in the posterior chamber in 22 cases and its absence in 9 cases. Among the 18 UBM-positive cases, 7 had biomicroscopic detectable involvement of the anterior chamber. There was a significant correlation between echodensities consistent with retinoblastoma on UBM in the posterior chamber and histopathological tumorous involvement of the posterior chamber (p=0.0001). The sensitivity of UBM in the assessment of posterior chamber invasion by retinoblastoma was 81% and the specificity was 100%. CONCLUSION: In selected cases of advanced retinoblastoma, UBM appears to represent a valuable tool in the precise evaluation of anterior extension of disease, with good sensitivity and specificity for the assessment of posterior chamber involvement. UBM may provide useful criteria governing the indication for enucleation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Decreasing perinatal morbidity and mortality is one of the main goals of obstetrics. Prognosis of preterm births depends on gestational age and birthweight. Multidisciplinary management is discussed with the parents according to these two parameters. In other circumstances, a suspected macrosomy will influence the management of the last weeks of pregnancy. Induction of labor or Cesarean delivery will be considered to avoid shoulder dystocia, brachial plexus injury or perinatal asphyxia. Birthweight needs to be estimated with accuracy, and this article describes the efficiency of various ultrasound weight estimation formulae for small and large fetuses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Technological limitations and power constraints are resulting in high-performance parallel computing architectures that are based on large numbers of high-core-count processors. Commercially available processors are now at 8 and 16 cores and experimental platforms, such as the many-core Intel Single-chip Cloud Computer (SCC) platform, provide much higher core counts. These trends are presenting new sets of challenges to HPC applications including programming complexity and the need for extreme energy efficiency.In this work, we first investigate the power behavior of scientific PGAS application kernels on the SCC platform, and explore opportunities and challenges for power management within the PGAS framework. Results obtained via empirical evaluation of Unified Parallel C (UPC) applications on the SCC platform under different constraints, show that, for specific operations, the potential for energy savings in PGAS is large; and power/performance trade-offs can be effectively managed using a cross-layerapproach. We investigate cross-layer power management using PGAS language extensions and runtime mechanisms that manipulate power/performance tradeoffs. Specifically, we present the design, implementation and evaluation of such a middleware for application-aware cross-layer power management of UPC applications on the SCC platform. Finally, based on our observations, we provide a set of recommendations and insights that can be used to support similar power management for PGAS applications on other many-core platforms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quantitative ultrasound of bone is a promising method for bone assessment: radiation-free, portable and predictive of hip fracture. Its portability allowed us to study the relationships between ultrasonic parameters of bone with age and with non-vertebral fractures in elderly women living in 19 nursing homes. Broadband ultrasound attenuation (BUA) and speed of sound (SOS) of the calcaneus were measured (and the stiffness index calculated) in a sample of 270 institutionalized women, aged 85 +/- 7 years, using an Achilles bone densitometer (Lunar). The effects of age, history of non-vertebral and non-traumatic fractures, body mass index, triceps skinfold and arm circumference were assessed on BUA, SOS and stiffness index. Furthermore, to evaluate longitudinally the influence of aging on the ultrasound parameters of bone, 60 subjects from the same group had a second ultrasound measurement after 1 year. The cross-sectional analysis of the data on all 270 women showed a significant decrease (p < 0.001) with age in BUA, SOS and stiffness index (-0.47%, -0.06%, and -1.01% respectively per year). In the 94 women, (35%) with a history of previous non-vertebral fractures, ultrasound parameters were significantly lower (p < 0.0001) than in the 176 women with no history of fracture (-8.3% for BUA, -1.3% for SOS, -18.9% for stiffness index). In contrast, there was no significant difference in anthropometric measurements between the groups with and without previous non-vertebral fractures, although the measurements decreased significantly with age. In the longitudinal study, repeated quantitative ultrasound after 11.4 +/- 0.8 months showed no significant decrease in BUA (-1%) but a significant decrease in SOS (-0.3%, p < 0.0001) and in stiffness index (-3.6%, p < 0.0002). In conclusion, quantitative ultrasound of the calcaneus measures properties of bone which continue to decline in institutionalized elderly women, and is able to discriminate women with previous non-vertebral fractures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This Technical Report presents a tentative protocol used to assess the viability of powersupply systems. The viability of power-supply systems can be assessed by looking at the production factors (e.g. paid labor, power capacity, fossil-fuels) – needed for the system to operate and maintain itself – in relation to the internal constraints set by the energetic metabolism of societies. In fact, by using this protocol it becomes possible to link assessments of technical coefficients performed at the level of the power-supply systems with assessments of benchmark values performed at the societal level throughout the relevant different sectors. In particular, the example provided here in the case of France for the year 2009 makes it possible to see that in fact nuclear energy is not viable in terms of labor requirements (both direct and indirect inputs) as well as in terms of requirements of power capacity, especially when including reprocessing operations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper aims to survey the techniques and methods described in literature to analyse and characterise voltage sags and the corresponding objectives of these works. The study has been performed from a data mining point of view