990 resultados para Pharmacokinetic parameters
Resumo:
Among various technologies to tackle the twin challenges of sustainable energy supply and climate change, energy saving through advanced control plays a crucial role in decarbonizing the whole energy system. Modern control technologies, such as optimal control and model predictive control do provide a framework to simultaneously regulate the system performance and limit control energy. However, few have been done so far to exploit the full potential of controller design in reducing the energy consumption while maintaining desirable system performance. This paper investigates the correlations between control energy consumption and system performance using two popular control approaches widely used in the industry, namely the PI control and subspace model predictive control. Our investigation shows that the controller design is a delicate synthesis procedure in achieving better trade-o between system performance and energy saving, and proper choice of values for the control parameters may potentially save a significant amount of energy
Resumo:
Highway structures such as bridges are subject to continuous degradation primarily due to ageing and environmental factors. A rational transport policy requires the monitoring of this transport infrastructure to provide adequate maintenance and guarantee the required levels of transport service and safety. In Europe, this is now a legal requirement - a European Directive requires all member states of the European Union to implement a Bridge Management System. However, the process is expensive, requiring the installation of sensing equipment and data acquisition electronics on the bridge. This paper investigates the use of an instrumented vehicle fitted with accelerometers on its axles to monitor the dynamic behaviour of bridges as an indicator of its structural condition. This approach eliminates the need for any on-site installation of measurement equipment. A simplified half-car vehicle-bridge interaction model is used in theoretical simulations to test the possibility of extracting the dynamic parameters of the bridge from the spectra of the vehicle accelerations. The effect of vehicle speed, vehicle mass and bridge span length on the detection of the bridge dynamic parameters are investigated. The algorithm is highly sensitive to the condition of the road profile and simulations are carried out for both smooth and rough profiles
Resumo:
This paper investigates the feasibility of using an instrumented vehicle to detect bridge dynamic parameters, such as natural frequency and structural damping, in a scaled laboratory experiment. In the experiment, a scaled vehicle model crosses a steel girder which has been adopted as the bridge model. The bridge model also includes a scaled road surface profile. The effects of varying vehicle model mass and speed are investigated. The damping of the girder is also varied. The bridge frequency and changes in damping are detected in the vehicle acceleration response in the presence of a rough road surface profile.
Resumo:
This paper presents the practical use of Prony Analysis to identify small signal oscillation mode parameters from simulated and actual phasor measurement unit (PMU) ringdown data. A well-known two-area four-machine power system was considered as a study case while the latest PMU ringdown data were collected from a double circuit 275 kV main interconnector on the Irish power system. The eigenvalue analysis and power spectral density were also conducted for the purpose of comparison. The capability of Prony Analysis to identify the mode parameters from three different types of simulated PMU ringdown data has been shown successfully. Furthermore, the results indicate that the Irish power system has dominant frequency modes at different frequencies. However, each mode has good system damping.
Resumo:
Hidden Markov models (HMMs) are widely used probabilistic models of sequential data. As with other probabilistic models, they require the specification of local conditional probability distributions, whose assessment can be too difficult and error-prone, especially when data are scarce or costly to acquire. The imprecise HMM (iHMM) generalizes HMMs by allowing the quantification to be done by sets of, instead of single, probability distributions. iHMMs have the ability to suspend judgment when there is not enough statistical evidence, and can serve as a sensitivity analysis tool for standard non-stationary HMMs. In this paper, we consider iHMMs under the strong independence interpretation, for which we develop efficient inference algorithms to address standard HMM usage such as the computation of likelihoods and most probable explanations, as well as performing filtering and predictive inference. Experiments with real data show that iHMMs produce more reliable inferences without compromising the computational efficiency.
Resumo:
PURPOSE:
To determine the test-retest variability in perimetric, optic disc, and macular thickness parameters in a cohort of treated patients with established glaucoma.
PATIENTS AND METHODS:
In this cohort study, the authors analyzed the imaging studies and visual field tests at the baseline and 6-month visits of 162 eyes of 162 participant in the Glaucoma Imaging Longitudinal Study (GILS). They assessed the difference, expressed as the standard error of measurement, of Humphrey field analyzer II (HFA) Swedish Interactive Threshold Algorithm fast, Heidelberg retinal tomograph (HRT) II, and retinal thickness analyzer (RTA) parameters between the two visits and assumed that this difference was due to measurement variability, not pathologic change. A statistically significant change was defined as twice the standard error of measurement.
RESULTS:
In this cohort of treated glaucoma patients, it was found that statistically significant changes were 3.2 dB for mean deviation (MD), 2.2 for pattern standard deviation (PSD), 0.12 for cup shape measure, 0.26 mm for rim area, and 32.8 microm and 31.8 microm for superior and inferior macular thickness, respectively. On the basis of these values, it was estimated that the number of potential progression events detectable in this cohort by the parameters of MD, PSD, cup shape measure, rim area, superior macular thickness, and inferior macular thickness was 7.5, 6.0, 2.3, 5.7, 3.1, and 3.4, respectively.
CONCLUSIONS:
The variability of the measurements of MD, PSD, and rim area, relative to the range of possible values, is less than the variability of cup shape measure or macular thickness measurements. Therefore, the former measurements may be more useful global measurements for assessing progressive glaucoma damage.
Resumo:
PURPOSE: To estimate the relationships between ocular parameters and tonometrically measured intraocular pressure (IOP), to determine the influence of ocular parameters on different instrument measurements of IOP, and to evaluate the association of ocular parameters with a parameter called hysteresis. METHODS: Patients presenting at a glaucoma clinic were recruited for this study. Subjects underwent IOP measurement with the Goldmann applanation tonometer (GAT), the TonoPen, and the Reichert Ocular Response Analyzer (ORA), and also measurements of central corneal thickness (CCT), axial length, corneal curvature, corneal astigmatism, central visual acuity, and refractive error. Chart information was reviewed to determine glaucoma treatment history. The ORA instrument provided a measurement called corneal hysteresis. The association between measured IOP and the other ocular characteristics was estimated using generalized estimating equations. RESULTS: Among 230 patients, IOP measurements from the TonoPen read lowest, and ORA read highest, and GAT measurements were closest to the mean IOP of the 3 instruments. In a multiple regression model adjusting for age, sex, race, and other ocular characteristics, a 10 microm increase in CCT was associated with an increase of 0.79 mm Hg measured IOP in untreated eyes (P<0.0001). Of the 3 tonometers, GAT was the least affected by CCT (0.66 mm Hg/10 mum, P<0.0001). Hysteresis was significantly correlated with CCT with a modest correlation coefficient (r=0.20, P<0.0007). CONCLUSIONS: Among parameters related to measured IOP, features in addition to CCT, such as hysteresis and corneal curvature, may also be important. Tonometric instruments seem to be affected differently by various physiologic characteristics.
Resumo:
The main objective of this research was the study of the soil nematode community, and in particular plant parasitic nematodes (PPN), from a field located in Portugal’s southern region, used for sugarbeet production. The study was performed from February to July 2003, covering part of the fallow period previous to tomato cultivation, the alternative crop in the rotation. The end of the fallow period in March and the soil preparation period in May were marked by a significant reduction in the numbers of PPN, whereas their numbers increased on the following tomato crop. The genus Helicotylenchus stood out as the most representative group, forming 90% of all PPN counted each month. The genus Heterodera was relatively abundant in the months following the previous sugarbeet crop, and numbers of the genus Meloidogyne increased during the tomato crop. The correlations between these group and environmental parameters show that, apart from the direct influence of the host, pH, organic matter, temperature and soil moisture significantly influenced nematode abundance and community composition.
EFFECT OF DIFFERENT STORAGE CONDITIONS ON NUTRITIONAL AND QUALITY PARAMETERS OF 'SWEETHEART' CHERRY.
Resumo:
Abstract The sweet cherry ‘Sweetheart’, although having a short shelf life, is highly appreciated by consumers due to its organoleptic characteristics. Different storage methods were tested to study the maintenance of quality during a period of 27 days: 1) cold (air at 1°C and 95% relative humidity) (CC), 2) cold and polypropylene film bags (1°C and 95% relative humidity) (MA) and 3) cold and controlled atmosphere (1°C, 95% RH, 10% CO2 and 8% O2) (CA). Quality parameters tested included external colour (L*, a*, b*), total soluble solids (TSS), and titratable acidity (TA). To evaluate nutritional quality anthocyanins, total antioxidant activity, and total phenolics were measured. Results allow us to say that phenolic compounds were relatively stable and similar during storage in CC and MA. Cherries stored under CA conditions presented lowest concentrations of phenolic compounds. Phenolic compounds, total anthocyanins and antioxidant activity were inversely correlated with values of colour coordinates. Considering all the evaluations done during this work it is unquestionable that fruits stored in controlled atmosphere conditions had significantly different quality.
Resumo:
Sweet cherries (Prunus avium L.) ‘Sweetheart’ were harvested at different production regions from Portugal (Cova da Beira and Portalegre) and Spain (Valle de Jerte). Cherries were harvested at their commercial maturation according to the empirical knowledge of external color corresponding to good quality. Fruits were stored and evaluated in order to study their quality on the harvest day and during a period of 21 days, at cold storage (1 ºC, 95% RH). The sweet cherry ‘Sweetheart’ is a well-known variety and a highly appreciated one but fruits present a short shelf life. On the other hand the effect of different “terroir” on cherry characteristics should be known and clarified. Fruits from day 0, considered without storage, were kept at 20ºC and analyzed. Every weak, 3 replicas were randomly picked up and 10 fruits from each one were submitted to several analyses after fruit temperature stabilized at 20ºC. Several quality parameters were evaluated: external colour (L*, a*, b*), texture, soluble solids content (SSC), titratable acidity (TA) and the ratio between soluble solid contents (SSC) and tritratable acidity (TA). Fruits from different orchards and locations were significantly different according to these parameters. Fruits from Cova da Beira were less firm comparing with other two regions, Valle de Jerte and Portalegre, which may indicate a higher maturation rate at harvest in those fruits. This is in accordance with SSC/titratable acidity rate suggesting a late harvest in Cova da Beira comparing with other two orchards, however fruits from Cova da Beira exhibit a poor color at harvest. These results clearly showed a lower correlation between SSC and firmness considering fruits origin.
Resumo:
SHORT-TERM EFFECTS OF SALINITY ON SOME PHYSIOLOGICAL PARAMETERS OF YOUNG OLIVE TREES OF ARBEQUINA, COBRANÇOSA AND GALEGA VARIETIES Ana Elisa Rato1,4, Renato Coelho1, Margarida Vaz1, Teresa Carola2, Dália Barbosa2, Nádia Silva1, José dos Santos2, Lourenço Machado2, João Godinho2, Luzia Ruas2, Margarida Barradas2, Hernani Pereira2, Sara Porfírio4 1 ICAAM, Universidade de Évora, Apartado 94, 7002-554 Évora, Portugal 2 Master students, Universidade de Évora, Apartado 94, 7002-554 Évora, Portugal 3 Ph.D. student, Universidade de Évora, Apartado 94, 7002-554 Évora, Portugal 4 aerato@uevora.pt Due to the desertification in some regions, the interest in plant’s tolerance to salinity has been increasing, as this response is determining for plant survival in stress conditions. This work reports the investigation of tolerance to salt in two year-old olive trees (Olea europaea L.) of three varieties, Arbequina, Cobrançosa and Galega vulgar. Plants were grown in 10 L plastic pots containing approximately 9 Kg of a sandy granitic soil, on a greenhouse. For 3 months (from the beginning of February to the end of April 2012), they were subjected to three levels of salinity in the irrigation water, 0 mM, 80 mM and 200 mM NaCl (6 plants per salinity level in a total of 18 plants of each variety),. Stomatal conductance (gs) and relative leaf chlorophyll content were assessed on each plant in February, March and April. Mid-day leaf water potential () and soil salinity were measured at the end of the experiment (April). On average, concerning all treatments and dates of determination, stomatal conductance of Arbequina and Galega vulgar was quite similar, around 40 mmol m-2 s-1, but Cobrançosa had a value of gs 36% higher, almost 50% higher (61 mmol m-2 s-1) when compared with the controls (0 mM salt) of the other two varieties. In percentage of controls, there was little difference in gs between varieties and between salinities during February and March. In contrast, in April, after about 90 days of exposure to salt, there was a clear decrease in gs with salt irrigation, proportional to salt concentration. Compared with controls, plants irrigated with 200 mM salt showed around 80% (Arbequina) or 85% (Cobrançosa and Galega vulgar) decrease in gs. Chlorophyll content of leaves showed less than 5% difference between varieties on the average of all treatments and dates of determination. During the course of this experiment, the salinity levels used did not show any relevant effect on chlorophyll content. Overall, at the end of the experimental period (April), leaf water potential () at midday was significantly higher in Cobrançosa (-1,4 MPa) than in Galega vulgar (-1,7 MPa) or Arbequina (-1,8 MPa), and salt decreased of control plants (-1,25 MPa) by an average 30% (with 80 mM) and 65% (with 200 mM). At the end of the experiment, salinity in the soil irrigated with 0 mM, 80 mM or 200 mM NaCl was, on average of all varieties, 0,2 mS, 1,0 mS or 2,0 mS, respectively. Soil salinity was quite similar in Arbequina and Galega vulgar but about 35% lower in the pots of Cobrançosa, on average of all salt-irrigation levels. Plants of Cobrançosa had higher stomatal conductance, however they showed higher water potential and lower salinity in the soil. These apparently contradictory results seem to suggest that Cobrançosa responds to salt differently from the other two varieties. This issue needs further investigation.
Resumo:
Esta tese pretende contribuir para o estudo e análise dos factores relacionados com as técnicas de aquisição de imagens radiológicas digitais, a qualidade diagnóstica e a gestão da dose de radiação em sistema de radiologia digital. A metodologia encontra-se organizada em duas componentes. A componente observacional, baseada num desenho do estudo de natureza retrospectiva e transversal. Os dados recolhidos a partir de sistemas CR e DR permitiram a avaliação dos parâmetros técnicos de exposição utilizados em radiologia digital, a avaliação da dose absorvida e o índice de exposição no detector. No contexto desta classificação metodológica (retrospectiva e transversal), também foi possível desenvolver estudos da qualidade diagnóstica em sistemas digitais: estudos de observadores a partir de imagens arquivadas no sistema PACS. A componente experimental da tese baseou-se na realização de experiências em fantomas para avaliar a relação entre dose e qualidade de imagem. As experiências efectuadas permitiram caracterizar as propriedades físicas dos sistemas de radiologia digital, através da manipulação das variáveis relacionadas com os parâmetros de exposição e a avaliação da influência destas na dose e na qualidade da imagem. Utilizando um fantoma contrastedetalhe, fantomas antropomórficos e um fantoma de osso animal, foi possível objectivar medidas de quantificação da qualidade diagnóstica e medidas de detectabilidade de objectos. Da investigação efectuada, foi possível salientar algumas conclusões. As medidas quantitativas referentes à performance dos detectores são a base do processo de optimização, permitindo a medição e a determinação dos parâmetros físicos dos sistemas de radiologia digital. Os parâmetros de exposição utilizados na prática clínica mostram que a prática não está em conformidade com o referencial Europeu. Verifica-se a necessidade de avaliar, melhorar e implementar um padrão de referência para o processo de optimização, através de novos referenciais de boa prática ajustados aos sistemas digitais. Os parâmetros de exposição influenciam a dose no paciente, mas a percepção da qualidade de imagem digital não parece afectada com a variação da exposição. Os estudos que se realizaram envolvendo tanto imagens de fantomas como imagens de pacientes mostram que a sobreexposição é um risco potencial em radiologia digital. A avaliação da qualidade diagnóstica das imagens mostrou que com a variação da exposição não se observou degradação substancial da qualidade das imagens quando a redução de dose é efectuada. Propõe-se o estudo e a implementação de novos níveis de referência de diagnóstico ajustados aos sistemas de radiologia digital. Como contributo da tese, é proposto um modelo (STDI) para a optimização de sistemas de radiologia digital.
Resumo:
This work investigates new channel estimation schemes for the forthcoming and future generation of cellular systems for which cooperative techniques are regarded. The studied cooperative systems are designed to re-transmit the received information to the user terminal via the relay nodes, in order to make use of benefits such as high throughput, fairness in access and extra coverage. The cooperative scenarios rely on OFDM-based systems employing classical and pilot-based channel estimators, which were originally designed to pointto-point links. The analytical studies consider two relaying protocols, namely, the Amplifyand-Forward and the Equalise-and-Forward, both for the downlink case. The relaying channels statistics show that such channels entail specific characteristics that comply to a proper filter and equalisation designs. Therefore, adjustments in the estimation process are needed in order to obtain the relay channel estimates, refine these initial estimates via iterative processing and obtain others system parameters that are required in the equalisation. The system performance is evaluated considering standardised specifications and the International Telecommunication Union multipath channel models.