977 resultados para Pain-evaluation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this chapter we introduce and explore the notion of “intentionally enriched awareness”. Intentional enrichment refers to the process of actively engaging users in the awareness process by enabling them to express intentions. We initially look at the phenomenon if sharing intentional information in related collaborative systems. We then explore the concept of intentional enrichment through designing and evaluating the AnyBiff system which allows users to freely create, share and use a variety of biff applications. Biffs are simple representation of pre-defined activities. Users can select biffs to indicate that they are engaged in an activity. We summarise the results of a trial which allowed us to gain insights into the potential of the AnyBiff prototype and the underlying biff concept to implement intentionally enriched awareness. Our findings show that intentional disclosure mechanisms in the form of biffs were successfully used in a variety of contexts. Users actively engaged in the design of a large variety of biffs and explored many different uses of the concept. The study revealed a whole host of issues with regard to intentionally enriched awareness which give valuable insight into the conception and design of future applications in this area.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Procedural sedation and analgesia (PSA) is used to attenuate the pain and distress that may otherwise be experienced during diagnostic and interventional medical or dental procedures. As the risk of adverse events increases with the depth of sedation induced, frequent monitoring of level of consciousness is recommended. Level of consciousness is usually monitored during PSA with clinical observation. Processed electroencephalogram-based depth of anaesthesia (DoA) monitoring devices provide an alternative method to monitor level of consciousness that can be used in addition to clinical observation. However, there is uncertainty as to whether their routine use in PSA would be justified. Rigorous evaluation of the clinical benefits of DoA monitors during PSA, including comprehensive syntheses of the available evidence, is therefore required. One potential clinical benefit of using DoA monitoring during PSA is that the technology could improve patient safety by reducing sedation-related adverse events, such as death or permanent neurological disability. We hypothesise that earlier identification of lapses into deeper than intended levels of sedation using DoA monitoring leads to more effective titration of sedative and analgesic medications, and results in a reduction in the risk of adverse events caused by the consequences of over-sedation, such as hypoxaemia. The primary objective of this review is to determine whether using DoA monitoring during PSA in the hospital setting improves patient safety by reducing the risk of hypoxaemia (defined as an arterial partial pressure of oxygen below 60 mmHg or percentage of haemoglobin that is saturated with oxygen [SpO2] less than 90 %). Other potential clinical benefits of using DoA monitoring devices during sedation will be assessed as secondary outcomes. Methods/design Electronic databases will be systematically searched for randomized controlled trials comparing the use of depth of anaesthesia monitoring devices with clinical observation of level of consciousness during PSA. Language restrictions will not be imposed. Screening, study selection and data extraction will be performed by two independent reviewers. Disagreements will be resolved by discussion. Meta-analyses will be performed if suitable. Discussion This review will synthesise the evidence on an important potential clinical benefit of DoA monitoring during PSA within hospital settings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Pregabalin is a treatment option for patients with persistent neuropathic pain. Its use has been associated with changes in mood and the development of depression and/or suicidal ideation. Objective Case presentations were reviewed of five patients reporting changes in mood, depression and suicidal ideation from the first 50 (approximately) patients commenced on pregabalin at the clinic. Discussion Although these patients had a history of depression, their mood had been stable before commencing pregabalin. Soon after commencement they reported changes in mood, and development of depression and/or suicidal ideation, which improved with dose reduction or cessation of pregabalin. Ultimately, all five patients ceased pregabalin treatment. Suicidal ideation is a recog-nised adverse effect of pregabalin. Patients should be warned of and monitored for deterioration in mood.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neuropathic pain is one of the most difficult medical conditions to treat and although the primary goal is to alleviate pain, many clinicians now recognise that the most appropriate therapeutic goal may be to reduce pain to a more tolerable level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Air Pollution Model and Chemical Transport Model (TAPM-CTM) framework has been tested and applied originally in Sydney to quantify particle and gaseous concentration (Cope et al, 2014). However, the model performance had not been tested in the south-eastern Queensland region (SEQR), Australia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Object detection is a fundamental task in many computer vision applications, therefore the importance of evaluating the quality of object detection is well acknowledged in this domain. This process gives insight into the capabilities of methods in handling environmental changes. In this paper, a new method for object detection is introduced that combines the Selective Search and EdgeBoxes. We tested these three methods under environmental variations. Our experiments demonstrate the outperformance of the combination method under illumination and view point variations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intelligent Transport Systems (ITS) have the potential to substantially reduce the number of crashes caused by human errors at railway levels crossings. However, such systems could overwhelm drivers, generate different types of driver errors and have negative effects on safety at level crossing. The literature shows an increasing interest for new ITS for increasing driver situational awareness at level crossings, as well as evaluations of such new systems on compliance. To our knowledge, the potential negative effects of such technologies have not been comprehensively evaluated yet. This study aimed at assessing the effect of different ITS interventions, designed to enhance driver behaviour at railway crossings, on driver’s cognitive loads. Fifty eight participants took part in a driving simulator study in which three ITS devices were tested: an in-vehicle visual ITS, an in-vehicle audio ITS, and an on-road valet system. Driver cognitive load was objectively and subjectively assessed for each ITS intervention. Objective data were collected from a heart rate monitor and an eye tracker, while subjective data was collected with the NASA-TLX questionnaire. Overall, results indicated that the three trialled technologies did not result in significant changes in cognitive load while approaching crossings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The project investigated the molecular response of Tra catfish (Pangasianodon hypophthalmus) to elevated salinity conditions. We employed Next generation sequencing platform to evaluate differential gene expression profiles of key genes under two salinity conditions. Results of the current project can form the basis for further studies to confirm the functional roles of specific genes that influence salinity tolerance in the target species and more broadly in other freshwater teleost fishes. Ultimately, the approach can contribute to developing superior culture stocks of the target species.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Partial evaluation of infrastructure investments have resulted in expensive mistakes, unsatisfactory outcomes and increased uncertainties for too many stakeholders, communities and economies in both developing and developed nations. "Complex Stakeholder Perception Mapping" (CSPM), is a novel approach that can address existing limitations by inclusively framing, capturing and mapping the spectrum of insights and perceptions using extended Geographic Information Systems. Maps generated in CSPM offer presentations of flexibly combined, complex perceptions of stakeholders on multiple aspects of development. CSPM extends the applications of GIS software in non-spatial mapping and of Multi-Criteria Analysis with a multidimensional evaluation platform and augments decision science capabilities in addressing complexities. Application of CSPM can improve local and regional economic gains from infrastructure projects and aid any multi-objective and multi-stakeholder decision situations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Embedded many-core architectures contain dozens to hundreds of CPU cores that are connected via a highly scalable NoC interconnect. Our Multiprocessor-System-on-Chip CoreVAMPSoC combines the advantages of tightly coupled bus-based communication with the scalability of NoC approaches by adding a CPU cluster as an additional level of hierarchy. In this work, we analyze different cluster interconnect implementations with 8 to 32 CPUs and compare them in terms of resource requirements and performance to hierarchical NoCs approaches. Using 28nm FD-SOI technology the area requirement for 32 CPUs and AXI crossbar is 5.59mm2 including 23.61% for the interconnect at a clock frequency of 830 MHz. In comparison, a hierarchical MPSoC with 4 CPU cluster and 8 CPUs in each cluster requires only 4.83mm2 including 11.61% for the interconnect. To evaluate the performance, we use a compiler for streaming applications to map programs to the different MPSoC configurations. We use this approach for a design-space exploration to find the most efficient architecture and partitioning for an application.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives The rapid uptake of nurse practitioner (NP) services in Australia has outpaced evaluation of this service model. A randomized controlled trial was conducted to compare the effectiveness of NP service versus standard medical care in the emergency department (ED) of a major referral hospital in Australia. Methods Patients presenting with pain were randomly assigned to receive either standard ED medical care or NP care. Primary investigators were blinded to treatment allocation for data analyses. The primary outcome measure was the proportion of patients receiving analgesia within 30 minutes from being seen by care group. Secondary outcome measures were time to analgesia from presentation and documentation of and changes in pain scores. Results There were 260 patients randomized; 128 received standard care (medical practitioner led), and 130 received NP care. Two patients needed to be excluded due to incomplete consent forms. The proportion of patients who received analgesia within 30 minutes from being seen was 49.2% (n = 64) in the NP group and 29.7% (n = 38) in the standard group, a difference of 19.5% (95% confidence interval [CI] = 7.9% to 31.2%; p = 0.001). Of 165 patients who received analgesia, 64 (84.2%) received analgesia within 30 minutes in the NP group compared to 38 (42.7%) in the standard care group, a difference in proportions of 41.5% (95% CI = 28.3% to 54.7%; p < 0.001). The mean (±SD) time from being seen to analgesia was 25.4 (±39.2) minutes for NP care and 43.0 (±35.5) minutes for standard care, a difference of 17.6 minutes (95% CI = 6.1 to 29.1 minutes; p = 0.003). There was a difference in the median change in pain score of 0.5 between care groups, but this was not statistically significant (p = 0.13). Conclusions Nurse practitioner service effectiveness was demonstrated through superior performance in achieving timely analgesia for ED patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper details the design and performance assessment of a unique collision avoidance decision and control strategy for autonomous vision-based See and Avoid systems. The general approach revolves around re-positioning a collision object in the image using image-based visual servoing, without estimating range or time to collision. The decision strategy thus involves determining where to move the collision object, to induce a safe avoidance manuever, and when to cease the avoidance behaviour. These tasks are accomplished by exploiting human navigation models, spiral motion properties, expected image feature uncertainty and the rules of the air. The result is a simple threshold based system that can be tuned and statistically evaluated by extending performance assessment techniques derived for alerting systems. Our results demonstrate how autonomous vision-only See and Avoid systems may be designed under realistic problem constraints, and then evaluated in a manner consistent to aviation expectations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, a novel 2×2 multiple-input multiple-output orthogonal frequency division multiplexing (MIMO-OFDM) testbed based on an Analog Devices AD9361 highly integrated radio frequency (RF) agile transceiver was specifically implemented for the purpose of estimating and analyzing MIMO-OFDM channel capacity in vehicle-to-infrastructure (V2I) environments using the 920 MHz industrial, scientific, and medical (ISM) band. We implemented two-dimensional discrete cosine transform-based filtering to reduce the channel estimation errors and show its effectiveness on our measurement results. We have also analyzed the effects of channel estimation error on the MIMO channel capacity by simulation. Three different scenarios of subcarrier spacing were investigated which correspond to IEEE 802.11p, Long-Term Evolution (LTE), and Digital Video Broadcasting Terrestrial (DVB-T)(2k) standards. An extensive MIMO-OFDM V2I channel measurement campaign was performed in a suburban environment. Analysis of the measured MIMO channel capacity results as a function of the transmitter-to-receiver (TX-RX) separation distance up to 250 m shows that the variance of the MIMO channel capacity is larger for the near-range line-of-sight (LOS) scenarios than for the long-range non-LOS cases, using a fixed receiver signal-to-noise ratio (SNR) criterion. We observed that the largest capacity values were achieved at LOS propagation despite the common assumption of a degenerated MIMO channel in LOS. We consider that this is due to the large angular spacing between MIMO subchannels which occurs when the receiver vehicle rooftop antennas pass by the fixed transmitter antennas at close range, causing MIMO subchannels to be orthogonal. In addition, analysis on the effects of different subcarrier spacings on MIMO-OFDM channel capacity showed negligible differences in mean channel capacity for the subcarrier spacing range investigated. Measured channels described in this paper are available on request.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Study design Retrospective validation study. Objectives To propose a method to evaluate, from a clinical standpoint, the ability of a finite-element model (FEM) of the trunk to simulate orthotic correction of spinal deformity and to apply it to validate a previously described FEM. Summary of background data Several FEMs of the scoliotic spine have been described in the literature. These models can prove useful in understanding the mechanisms of scoliosis progression and in optimizing its treatment, but their validation has often been lacking or incomplete. Methods Three-dimensional (3D) geometries of 10 patients before and during conservative treatment were reconstructed from biplanar radiographs. The effect of bracing was simulated by modeling displacements induced by the brace pads. Simulated clinical indices (Cobb angle, T1–T12 and T4–T12 kyphosis, L1–L5 lordosis, apical vertebral rotation, torsion, rib hump) and vertebral orientations and positions were compared to those measured in the patients' 3D geometries. Results Errors in clinical indices were of the same order of magnitude as the uncertainties due to 3D reconstruction; for instance, Cobb angle was simulated with a root mean square error of 5.7°, and rib hump error was 5.6°. Vertebral orientation was simulated with a root mean square error of 4.8° and vertebral position with an error of 2.5 mm. Conclusions The methodology proposed here allowed in-depth evaluation of subject-specific simulations, confirming that FEMs of the trunk have the potential to accurately simulate brace action. These promising results provide a basis for ongoing 3D model development, toward the design of more efficient orthoses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The QUT-NOISE-SRE protocol is designed to mix the large QUT-NOISE database, consisting of over 10 hours of back- ground noise, collected across 10 unique locations covering 5 common noise scenarios, with commonly used speaker recognition datasets such as Switchboard, Mixer and the speaker recognition evaluation (SRE) datasets provided by NIST. By allowing common, clean, speech corpora to be mixed with a wide variety of noise conditions, environmental reverberant responses, and signal-to-noise ratios, this protocol provides a solid basis for the development, evaluation and benchmarking of robust speaker recognition algorithms, and is freely available to download alongside the QUT-NOISE database. In this work, we use the QUT-NOISE-SRE protocol to evaluate a state-of-the-art PLDA i-vector speaker recognition system, demonstrating the importance of designing voice-activity-detection front-ends specifically for speaker recognition, rather than aiming for perfect coherence with the true speech/non-speech boundaries.