989 resultados para PET fiber


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Drilling is a major process in the manufacturing of holes required for the assemblies of composite laminates in aerospace industry. Simulation of drilling process is an effective method in optimizing the drill geometry and process parameters in order to improve hole quality and to reduce the drill wear. In this research we have developed three-dimensional (3D) FE model for drilling CFRP. A 3D progressive intra-laminar failure model based on the Hashin's theory is considered. Also an inter-laminar delamination model which includes the onset and growth of delamination by using cohesive contact zone is developed. The developed model with inclusion of the improved delamination model and real drill geometry is used to make comparison between the step drill of different stage ratio and twist drill. Thrust force, torque and work piece stress distributions are estimated to decrease by the use of step drill with high stage ratio. The model indicates that delamination and other workpiece defects could be controlled by selection of suitable step drill geometry. Hence the 3D model could be used as a design tool for drill geometry for minimization of delamination in CFRP drilling. © 2013 Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dietary fiber has several anticarcinogenic effects and is thought to be protective against esophageal cancer. The aim of this systematic review was to quantify the association between dietary fiber and the risk of esophageal cancer by investigating histological subtypes of esophageal cancer and the stage at which fiber may influence the carcinogenic pathway. Systematic search strategies were used to identify relevant studies, and adjusted odds ratios (ORs) were combined using random-effects meta-analyses to assess the risk of cancer when comparing extreme categories of fiber intake. Ten relevant case-control studies were identified within the timeframe searched. Pooled estimates from eight studies of esophageal adenocarcinoma revealed a significant inverse association with the highest fiber intakes (OR 0.66; 95% confidence interval [CI] 0.44-0.98). Two studies also identified protective effects of dietary fiber against Barrett's esophagus. Similar, though nonsignificant, associations were observed when results from five studies of fiber intake and risk of squamous cell carcinoma were combined (OR 0.61; 95%CI 0.31-1.20). Dietary fiber is associated with protective effects against esophageal carcinogenesis, most notably esophageal adenocarcinoma. Potential methods of action include modification of gastroesophageal reflux and/or weight control.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the design, commissioning, and evaluation of a ?ber-optic strain sensor system for the structural health monitoring of a prestressed concrete posttensioned box girder railway bridge in Mumbai, India, which shows a number of well-documented structural problems. Preliminary laboratory trials to design the most appropriate sensor system that could be readily transported and used on site are described, followed by a description of load tests on the actual bridge undertaken in collaboration with Indian Railways and using locomotives of known weight. Results from the load tests using the optical system are compared with similar results obtained using electrical resistance strain gages. Conclusions are summarized concerning the integrity of the structure and for the future use of the sensor system for monitoring bridges of this type. Crack width measurements obtained during the load tests are also described.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction
PET-computed tomography (PET-CT) is a useful staging imaging modality in colorectal liver metastases (CRLM). This study aimed to determine whether PET-CT parameters, standardized uptake value (SUV) and reconstructed tumour volume (RTV), are predictors of prognosis and survival.

Methods
A study of all resectable CRLM patients in the regional HPB unit from 2007–2009 was performed. Preoperative PET-CT scans were retrospectively reviewed; SUV, diameter and RTV for each lesion was recorded. Correlation analysis was performed with other pathological and biochemical parameters, by Pearson’s correlation analysis. Survival analysis was performed using Cox regression hazard model. A P value of less than 0.05 was considered statistically significant.

Results
A total of 79 patients were included. SUV moderately correlated with tumour diameter, both PET-CT (r=0.4927; P<0.0001) and histology (r=0.4513; P=0.0003); RTV (r=0.4489; P<0.001), preoperative carcinoembryonic antigen (CEA) (r=0.4977; P=0.0001), and postoperative CEA (r=0.3727; P=0.004). Multivariate analysis found that an independent predictor of SUVmax was preoperative CEA (P=0.03). RTV strongly correlated with preoperative CEA (r=0.9389; P<0.0001). SUV and RTV had a negative effect on survival.

Conclusion
PET-CT, in the setting of CRLM, may have a prognostic role in assessing survival. Although no definite conclusions can be drawn regarding the prognostic role of SUV and RTV, it acts to reinforce the need for further prospective studies to validate these findings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aims to investigate drilling process in carbon-fiber reinforced plastic (CFRP) composites with multilayer TiAlN/TiN PVD-coated tungsten carbide drill. The effect of process parameters have been investigated in drilling of Hexcel M21-T700GC. Thrust force and torque were measured online throughout the drilling experiments. Delamination were observed using optical microscope and analyzed via a developed algorithm based on digital image processing technique. Surface roughness of each hole was measured using a surface profilometer. In addition, the progression of tool wear in various surfaces of drill was observed using tool microscope and measured using image software. Our results indicate that the thrust force and torque increased with the increasing cutting speed and feed rate. Delamination and average surface roughness that rose with the increase in feed rate, however, decreased with the increasing cutting speed. The average surface roughness tended to increase with the increase in feed rate and decrease with the increasing cutting speed in drilling of carbon-fiber reinforced plastic (CFRP). Feed rate was found as the predominant factor on the drilling outputs. Abrasive wear was observed on both flank and relief surfaces, which created edge wear on cutting edges. No sign of chipping or plastic deformation has been observed on the surfaces of drills. © 2012 The Author(s).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A robust finite element scheme for the micro-mechanical modeling of the behavior of fiber reinforced polymeric composites under external loads is developed. The developed model is used to simulate stress distribution throughout the composite domain and to identify the locations where maximum stress concentrations occur. This information is used as a guide to predict dominant failure and crack growth mechanisms in fiber reinforced composites. The differences between continuous fibers, which are susceptible to unidirectional transverse fracture, and short fibers have been demonstrated. To assess the validity and range of applicability of the developed scheme, numerical results obtained by the model are compared with the available experimental data and also with the values found using other methods reported in the literature. These comparisons show that the present finite element scheme can generate meaningful results in the analysis of fiber reinforced composites.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The fluorophore-spacer1-receptor1-spacer2-receptor2 system (where receptor2 alone is photoredox-inactive) shows ionically tunable proton-induced fluorescence off-on switching, which is reminiscent of thermionic triode behavior. This also represents a new extension to modular switch systems based on photoinduced electron transfer (PET) towards the emulation of analogue electronic devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Following a brief introduction to the principle of fluorescent PET (photoinduced electron transfer) sensors and switches, the outputs of laboratories in various countries from the past year or two are categorized and critically discussed. Emphasis is placed on the molecular design and the experimental outcomes in terms of target-induced fluorescence enhancements and input/output wavelengths. The handling of single targets takes up a major fraction of the review, but the extension to multiple targets is also illustrated. Conceptually new channels of investigation are opened up by the latter approach, e.g. ‘lab-on-a-molecule’ systems and molecular keypad locks. The growing trends of theoretically-fortified design and intracellular application are pointed out.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This document describes best practice and evidence based recommendations for the use of FDG-PET/CT for the purposes of radiotherapy target volume delineation (TVD) for curative intent treatment of non-small cell lung cancer (NSCLC). These recommendations have been written by an expert advisory group, convened by the International Atomic Energy Agency (IAEA) to facilitate a Coordinated Research Project (CRP) aiming to improve the applications of PET based radiation treatment planning (RTP) in low and middle income countries. These guidelines can be applied in routine clinical practice of radiotherapy TVD, for NSCLC patients treated with concurrent chemoradiation or radiotherapy alone, where FDG is used, and where a calibrated PET camera system equipped for RTP patient positioning is available. Recommendations are provided for PET and CT image visualization and interpretation, and for tumor delineation using planning CT with and without breathing motion compensation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The two families of fluorescent PET (photoinduced electron transfer) sensors (1-9) show that the effective proton density near the surface of several micelle membranes changes over 2-3 orders of magnitude as the microlocation of the sensor (with respect to the membrane) is altered via hydrophobic tuning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The fluorescence of molecules 1-3 is enhanced by factors of up to 67 in the presence of magnesium and calcium ions in neutral water which allows the selective monitoring of magnesium ions under simulated physiological conditions and permits the construction of truth tables with OR logic when these molecules are viewed as ion input-photon output molecuIar devices.