929 resultados para Nuclear saline water conversion plants.
Resumo:
1. Water intake induced by injection of 0.2 M-NaCl into the lateral preoptic area was increased by the injection of angiotensin II into the subfornical organ of rats. The injection of hypertonic saline solution into the subfornical organ increased water intake. However, the increase was lower than when the solution was injected into the lateral preoptic area. The injection of 4 μg angiotensin II into the lateral preoptic area further augmented this effect. 2. Injection of angiotensin II into the subfornical organ caused a rise in blood pressure which preceded the thirst-inducing effect. The injection of 0.2 M NaCl into the subfornical organ caused no changes in blood pressure, whereas the injection of angiotensin II into the lateral preoptic area caused some increase. 3. Dehydration of the lateral preoptic area by means of 0.2 M NaCl in combination with intravenous infusion of angiotensin II caused a summation of effects in terms of the water intake, without changing cardiovascular alterations induced by the infusion of angiotensin II. A summation of effects in the water intake, but not in blood pressure, was also observed when 0.5 M NaCl was infused intravenously in combination with the injection of angiotensin II into the subfornical organ and into the lateral preoptic area. 4. The results indicate that there are interactions between the subfornical organ and lateral preoptic area in the regulation of cardiovascular and thirst mechanisms.
Resumo:
Two projects of water treatment for public water supply were developed and operated by using combined systems of constructed wetlands. One of the projects was carried out in the town of Analandia, Sao Paulo, Brazil and wetlands with floating aquatic plants associated to the HDS system were used. Nearly 6480 inhabitants were supplied. The other conducted project was an experimental station in partnership with SABESP (Sao Paulo State Sanitation Agency/Brazil), for the pretreatment of 1700 l.s-1 of waters from the Cotia River, which is used for the population's supply after conventional treatment at the Lower Cotia Water Treatment Station. For this pilot project, wetlands with emergents and floating plants associated to the HDS system were used. The proposed objectives were achieved in both projects.
Resumo:
Technical and economic feasibility of using natural gas as a non-polluting energy source was studied. Conversion of electric ovens to gas-fired ovens for the preparation of aluminum plates for laminations was used as an example of this application. Four cases were evaluated for the use of heat derived from residual gases following combustion of the natural gas. Additionally, two possibilities are included for the use of systems of co-generation; one using an internal combustion engine, and second using a gas turbine. Results suggested that it was technically and economically feasible to convert the electric ovens considered to natural gas-operated ovens.
Resumo:
It is presented two study cases about the approach in root analysis at field and laboratory conditions based on digital image analysis. Grapevine (Vitis vinifera L.) and date palm (Phoenix dactylifera L.) root systems were analyzed by both the monolith and trench wall method aided by digital image analysis. Correlation between root parameters and their fractional distribution over the soil profile were obtained, as well as the root diameter estimation. Results have shown the feasibility of digital image analysis for evaluation of root distribution.
Resumo:
The project is being conducted in the town of Analândia, São Paulo, Brazil. The constructed wetlands system for water supply consists of a channel with floating aquatic macrophytes, HDS system (Water Decontamination with Soil - Patent PI 850.3030), chlorinating system, filtering system and distribution. The project objectives include investigating the process variables to further optimize design and operation factors, evaluating the relation of nutrients and plants development, biomass production, shoot development, nutrient cycling and total and fecal coliforms removal, comparing the treatment efficiency among the seasons of the year; and moreover to compare the average values obtained between February and June 1998 (Salati et al., 1998) with the average obtained for the same parameters between March and June 2000. Studies have been developed in order to verify during one year the drinking quality of the water for the following parameters: turbidity, color, pH, dissolved oxygen, total of dissolved solids, COD, chloride, among others, according to the Ministry of Health's Regulation 36. This system of water supply projected to treat 15 L s-1 has been in continuous operation for 2 years, it was implemented with support of the National Environment Fund (FNMA), administered by the Center of Environmental Studies (CEA-UNESP), while the technical supervision and design were performed by the Institute of Applied Ecology. The actual research project is being supported by FAPESP.
Resumo:
A study was conducted during 23 days in order to evaluate the impact of floating aquatic macrophyte on the water quality of a fishpond. Water samples were collected in four points, three inside the pond and one in water inlet. Drastic reduction of dissolved oxygen was observed in the pond, down to 0.87 mg/L. No significant differences (P > 0.05) were observed for total CO 2, nitrite and ammonia with respect to inlet water (P1) and inside the pond (P2, P3 e P4). Chlorophyll a displayed an inverse relationship with phosphorus. Among nitrogen compounds, ammonia presented the highest concentrations except in water inlet where nitrate was higher, 513.33 μg/l, as well as the highest conductivity values. The pH was slightly acid. The results obtained showed that the macrophyte cover promoted an adverse effect in the medium. Under control, aquatic plants might impact positively due to its capacity to reduce total phosphorus and nitrate in the water column as observed in this study.
Resumo:
In this paper, a methodology for the study of a fuel cell cogeneration system and applied to a university campus is developed. The cogeneration system consists of a molten carbonate fuel cell associated to an absorption refrigeration system. The electrical and cold-water demands of the campus are about 1,000 kW and 1,840 kW (at 7°C), respectively. The energy, exergy and economic analyses are presented. This system uses natural gas as the fuel and operates on electric parity. In conclusion, the fuel cell cogeneration system may have an excellent opportunity to strengthen the decentralized energy production in the Brazilian tertiary sector.
Resumo:
Germination of pelleted seeds of different lettuce cultivars was evaluated. The experimental design used was completely randomized, with four replications, in a factorial outline 5 x 4. Seeds of 'Elisa', 'Veronica AF 259', 'Vera' and 'Tainá' were tested. The sodium chloride (NaCl) concentrations used were 0; 50 Mm(2,9222 g/L); 100 Mm (5,8443 g/L); 150 Mm (8,7665 g/L); and 200 Mm (11,6886 g/L). Germination percentage, germination rate and number of normal seedling were evaluated. The concentration of 200 Mm of NaCl resulted in the lowest number of germinated plants. 'Veronica AF 259' germinated in the shortest time using a concentration of 150 Mn of NaCl.
Resumo:
Starting from the deregulated process of the Electric Sector, there was the need to attribute responsibilities to several agents and to elaborate appropriate forms of remuneration of the services rendered by the same. One of the services of great importance within this new electric sector is the Ancillary Services. Among the various types of Ancillary Services, Spinning Reserve is a service necessary for maintaining the integrity of the transmission system from either generation interruptions or load variations. This paper uses the application of the Economic Dispatch theory with the objective of quantifies the availability of Spinning Reserve supply in hydroelectric plants. The proposed methodology utilizes the generating units as well as their efficiencies so as to attend the total demand with the minimum water discharge. The proposed methodology was tested through the data provided by the Água Vermelha Hydroelectric Power Plant. These tests permitted the opportunity cost valuation to the Spinning Reserve supply in hydroelectric plants. © 2005 IEEE.
Resumo:
High-speed countercurrent chromatography (HSCCC) is a leading method for the fast separation of natural products from plants. It was used for the preparative isolation of two flavone monoglucosides present in the capitula of Eriocaulon ligulatum (Veil.) L.B.Smith (Eriocaulaceae). This species, known locally as botão-dourado, is exported to Europe, Japan and North America as an ornamental species, constituting an important source of income for the local population of Minas Gerais State, Brazil. The solvent system, optimized in tests prior to the HSCCC run, consisted of the two phases of the mixture ethyl acetate: n-propanol: water (140:8:80, v/v/v), which led to the successful separation of 6-methoxyluteolin-7-O-β-D-allopyranoside and 6-methoxyapigenin-7-O-β-D-allopyranoside in only 3 hours. The two flavonoids were identified by NMR (1-D and 2-D) and ESI-MS, comparing their spectra with published data.
Resumo:
The coffee crop is expanding to new areas with not enough studies about its response to saline irrigation water. The initial growth of coffee plant was evaluated, in greenhouse at the Engineering Department of the Federal University of Lavras (UFLA), under different levels of irrigation water salinity. The completely randomized design was used with 6 treatments (S0 = 0.0 dS m -1, S1 = 0.6 dS m -1, S2 = 1.2 dS m -1, S3 = 1.8 dS m -1, S4 = 2.4 dS m -1 and S5 = 3.0 dS m -1) and 4 replications. The irrigation was accomplished according to soil water retention curve and resistance block reading, restoring the soil water content to its field capacity. It was verified that water salinity affected the plants characteristics significantly. The water salinity above 1.2 dS m -1 caused damage to plant development resulting, in some cases, in death of plants. The leaf area of plant was the variable most affected by salinity of irrigation water. By the end of the experiment, the soil was classified as saline-sodic.
Resumo:
The effects of salt concentration levels in electrical conductivity (EC) were evaluated in chrysanthemum root, cultivated in substrate using two sampling methods, under greenhouse conditions. The experiment was carried out in Paranapanema, São Paulo using the experimental design in randomized blocks and four replications. The treatments consisted of eight sampling periods of substrate solutions in pots: 7, 14, 21, 28, 35, 42, 49 and 56 days after strike root and five salt concentration levels of applied saline solution: 1.42; 1.65; 1.89; 2.13 and 2.36 dS m -1 in the vegetative period and during the reproduction period of flower budding: 1.71; 1.97; 2.28; 2.57 and 2.85 dS m -1. The substrate solution EC monitoring was done using two methods: solution extractors and 1:2 water diluted solution. The use of solution extractors and 1:2 water diluted solution allowed substrate solution EC monitoring along the culture cycle; the amount of salt concentration applied in the substrate caused the substrate salinity increase; the method using solution extractors presented higher EC values in the substrate.
Resumo:
Negative effects of soil compaction have been recognized as one of the problems restricting the root system and consequently impairing yields, especially in the Southern Coastal Plain of the USA. Simulations of the root restricting layers in green house studies are necessary for the development of mechanism which alleviates soil compaction problems in these soils. The selection of three distinct bulk densities based on the standard proctor test is also an important factor to determine which bulk density restricts the root layer. The experiment was conducted to assess the root length density and root diameter of the corn (Zea mays L.) crop as a function of bulk density and water stress, characterized by the soil density (1.2; 1.4, and 1.6 g cm -3), and two levels of the water content, approximately (70 and 90% field capacity). The statistical design adopted was completely randomized design, with four replicates in a factorial pattern of (3 × 2). The PVC tubes were superimposed with an internal diameter of 20 cm with a height of 40 cm (the upper tube 20 cm, compacted and inferior tube 10 cm), the hardpan with different levels of soil compaction were located between 20 and 30 cm of the depth of the pot. Results showed that: the main effects of subsoil mechanical impedance were observed on the top layer indicating that the plants had to penetrate beyond the favorable soil conditions before root growth was affected from 3.16; 2.41 to 1.37 cm cm -3 (P<0.005). There was a significant difference at the hardpan layer for the two levels of water and 90% field capacity reduced the root growth from 0.91 to 0.60 cm cm -3 (P<0.005). The root length density and root diameter were affected by increasing soil bulk density from 1.2 to 1.6 g cm -3 which caused penetration resistance to increase to 1.4 MPa. Soil water content of 70% field capacity furnished better root growth in all the layers studied. The increase in root length density resulted in increased root volume. It can also be concluded that the effect of soil compaction impaired the root diameter mostly at the hardpan layer. Soil temperature had detrimental effect on the root growth mostly with higher bulk densities.
Resumo:
The effect of post-polymerization treatments (MW-microwave irradiatron and WB-water-bath) on the degree of conversion (DC) of three reline resins (Ufi Gel hard-U, Kooliner-K, and Tokuso Rebase Fast-T) and one denture base resin (Lucitone 550-L), submitted to two polymerization cycles (LS-short and LL-long), was evaluated by using FT-Raman spectroscopy (n = 5). The molecular weight (Mw) of the powder of all materials and of K polymerized specimens (control; MW; and WB; n = 3) was analyzed using GPC. DC data were analyzed using Kruskal-Wallis test (α = .05). For control specimens, there were no significant differences between U (68%) and LL (77%) and among LL, K (81%), and T (84%). LS (92%) had the highest DC (P<0.05). Only material K exhibited an increased DC after WB (P<0.05). All powders had Mw from 4.0 × 105 to 6.5 × 105 and narrow Mw distributions (2.1 to 3.6). Polymerization and post-polymerization produced K specimens with Mw similar to that of K powder.