918 resultados para Murmur of Surfaces
Resumo:
In power electronic basedmicrogrids, the computational requirements needed to implement an optimized online control strategy can be prohibitive. The work presented in this dissertation proposes a generalized method of derivation of geometric manifolds in a dc microgrid that is based on the a-priori computation of the optimal reactions and trajectories for classes of events in a dc microgrid. The proposed states are the stored energies in all the energy storage elements of the dc microgrid and power flowing into them. It is anticipated that calculating a large enough set of dissimilar transient scenarios will also span many scenarios not specifically used to develop the surface. These geometric manifolds will then be used as reference surfaces in any type of controller, such as a sliding mode hysteretic controller. The presence of switched power converters in microgrids involve different control actions for different system events. The control of the switch states of the converters is essential for steady state and transient operations. A digital memory look-up based controller that uses a hysteretic sliding mode control strategy is an effective technique to generate the proper switch states for the converters. An example dcmicrogrid with three dc-dc boost converters and resistive loads is considered for this work. The geometric manifolds are successfully generated for transient events, such as step changes in the loads and the sources. The surfaces corresponding to a specific case of step change in the loads are then used as reference surfaces in an EEPROM for experimentally validating the control strategy. The required switch states corresponding to this specific transient scenario are programmed in the EEPROM as a memory table. This controls the switching of the dc-dc boost converters and drives the system states to the reference manifold. In this work, it is shown that this strategy effectively controls the system for a transient condition such as step changes in the loads for the example case.
Resumo:
OBJECTIVE: The aim of this study was to determine the influence of polyvinyl chloride (PVC) wrapping on the performance of two laser fluorescence devices (LF and LFpen) by assessing tooth occlusal surfaces. BACKGROUND DATA: Protection of their tips may influence LF measurements. To date there are no studies evaluating the influence of this protection on the performance of the LFpen on permanent teeth, or comparing it to the original LF device. MATERIALS AND METHODS: One hundred nineteen permanent molars were assessed by two experienced dentists using the LF and the LFpen devices, both with and without PVC wrapping. The teeth were histologically prepared and assessed for caries extension. RESULTS: The LF values with and without PVC wrapping were significantly different. For both LF devices, the sensitivity and accuracy were lower when the PVC wrapping was used. The specificity was statistically significantly higher for the LFpen with PVC. No difference was found between the areas under the ROC curves with and without PVC wrapping. The ICC showed excellent interexaminer agreement. The Bland and Altman method showed a range between the upper and the lower limits of agreement of 63.4 and 57.8 units for the LF device, and 49.4 and 74.2 for the LFpen device, with and without PVC wrapping, respectively. CONCLUSIONS: We found an influence of the PVC wrapping on the performance of the LF and LFpen devices. However, since its influence on detection of occlusal caries lesions is considered for, the use of one PVC layer is suggested to avoid cross-contamination in clinical practice.
Resumo:
Transparent and translucent objects involve both light reflection and transmission at surfaces. This paper presents a physically based transmission model of rough surface. The surface is assumed to be locally smooth, and statistical techniques is applied to calculate light transmission through a local illumination area. We have obtained an analytical expression for single scattering. The analytical model has been compared to our Monte Carlo simulations as well as to the previous simulations, and good agreements have been achieved. The presented model has potential applications for realistic rendering of transparent and translucent objects.
Resumo:
The extents of functional surfaces (villi, microvilli) have been estimated at different longitudinal sites, and in the entire small intestine, for three species of bats belonging to two feeding groups: insect- and fruit-eaters. In all species, surface areas and other structural quantities tended to be greatest at more cranial sites and to decline caudally. The entomophagous bat (Miniopterus inflatus) had a mean body mass (coefficient of variation) of 8.9 g (5%) and a mean intestinal length of 20 cm (6%). The surface area of the basic intestinal tube (primary mucosa) was 9.1 cm2 (10%) but this was amplified to 48 cm2 (13%) by villi and to 0.13 m2 (20%) by microvilli. The total number of microvilli per intestine was 4 x 10(11) (20%). The average microvillus had a diameter of 8 nm (10%), a length of 1.1 microns (22%) and a membrane surface area of 0.32 micron 2 (31%). In two species of fruit bats (Epomophorus wahlbergi and Lisonycteris angolensis), body masses were greater and intestines longer, the values being 76.0 g (18%) and 76.9 g (4%), and 73 cm (16%) and 72 cm (7%), respectively. Surface areas were also greater, amounting to 76 cm2 (26%) and 45 cm2 (8%) for the primary mucosa, 547 cm2 (29%) and 314 cm2 (16%) for villi and 2.7 m2 (23%) and 1.5 m2 (18%) for microvilli. An increase in the number of microvilli, 33 x 10(11) (19%) and 15 x 10(11) (24%) per intestine, contributed to the more extensive surface area but there were concomitant changes in the dimensions of microvilli. Mean diameters were 94 nm (8%) and 111 nm (4%), and mean lengths were 2.8 microns (12%) and 2.9 microns (10%), respectively. Thus, an increase in the surface area of the average microvillus to 0.83 micron 2 (12%) and 1.02 microns 2 (11%) also contributed to the greater total surface area of microvilli. The lifestyle-related differences in total microvillous surface areas persisted when structural quantities were normalised for the differences in body masses. The values for total microvillous surface area were 148 cm2g-1 (20%) in the entomophagous bat, 355 cm2g-1 (20%) in E. wahlbergi and 192 cm2g-1 (17%) in L. angolensis. This was true despite the fact that the insecteater possessed a greater length of intestine per unit of body mass: 22 mm g-1 (8%) versus 9-10 mm g-1 (9-10%) for the fruit-eaters.
Resumo:
To assess the prevalence of tooth wear on buccal/facial and lingual/palatal tooth surfaces and identify related risk factors in a sample of young European adults, aged 18-35 years. Calibrated and trained examiners measured tooth wear, using the basic erosive wear examination (BEWE) on in 3187 patients in seven European countries and assessed the impact of risk factors with a previously validated questionnaire. Each individual was characterized by the highest BEWE score recorded for any scoreable surface. Bivariate analyses examined the proportion of participants who scored 2 or 3 in relation to a range of demographic, dietary and oral care variables. The highest tooth wear BEWE score was 0 for 1368 patients (42.9%), 1 for 883 (27.7%), 2 for 831 (26.1%) and 3 for 105 (3.3%). There were large differences between different countries with the highest levels of tooth wear observed in the UK. Important risk factors for tooth wear included heartburn or acid reflux, repeated vomiting, residence in rural areas, electric tooth brushing and snoring. We found no evidence that waiting after breakfast before tooth brushing has any effect on the degree of tooth wear (p=0.088). Fresh fruit and juice intake was positively associated with tooth wear. In this adult sample 29% had signs of tooth wear making it a common presenting feature in European adults.
Resumo:
The adsorption interactions of thallium and its compounds with gold and quartz surfaces were investigated. Carrier-free amounts of thallium were produced in nuclear fusion reactions of alpha particles with thick gold targets. The method chosen for the studies was gas thermochromatography and varying the redox potential of the carrier gases. It was observed that thallium is extremely sensitive to trace amounts of oxygen and water, and can even be oxidized by the hydroxyl groups located on the quartz surface. The experiments on a quartz surface with O2, He, H2 gas in addition with water revealed the formation and deposition of only one thallium species – TlOH. The adsorption enthalpy was determined to be Δ HSiO2ads(TlOH) = −134 ± 5 kJ mol−1. A series of experiments using gold as stationary surface and different carrier gases resulted in the detection of two thallium species – metallic Tl (H2 as carrier gas) and TlOH (O2, O2+H2O and H2+H2O as pure carrier gas or carrier gas mixture) with Δ HAuads(Tl) = −270 ± 10 kJ mol− and Δ HAuads(TlOH) = −146 ± 3 kJ mol−1. These data demonstrate a weak interaction of TlOH with both quartz and gold surfaces. The data represent important information for the design of future experiments with the heavier homologue of Tl in group 13 of the periodic table – element 113 (E113).
Resumo:
We present 3-D simulations of impacts into Asteroid 21 Lutetia, the subject of a fly-by by the European Space Agency's Rosetta mission to Comet 67P/Churyumov-Gerasimenko. Using a 3-D shape model of the asteroid, impacts of sizes sufficient to reproduce the observed craters in Lutetia's North Polar Crater Cluster (NPCC) as observed by the OSIRIS experiment have been simulated using the Smoothed Particle Hydrodynamics technique. The asteroid itself has been modelled both as a homogeneous body and as a body with an iron core.
Resumo:
Two polycrystalline diamond surfaces, manufactured by chemical vapour deposition (CVD) technique, are investigated regarding their applicability as charge state conversion surfaces (CS) for use in a low energy neutral atom imaging instrument in space research. The capability of the surfaces for converting neutral atoms into negative ions via surface ionisation processes was measured for hydrogen and oxygen with particle energies in the range from 100 eV to 1 keV and for angles of incidence between 6 deg and 15 deg. We observed surface charging during the surface ionisation processes for one of the CVD samples due to low electrical conductivity of the material. Measurements on the other CVD diamond sample resulted in ionisation efficiencies of ~2 % for H and up to 12 % for O. Analysis of the angular scattering revealed very narrow and almost circular scattering distributions. Comparison of the results with the data of the CS of the IBEX-Lo sensor shows that CVD diamond has great potential as CS material for future space missions.
Resumo:
This study aimed to evaluate the effectiveness of fluorescence-based methods (DIAGNOdent, LF; DIAGNOdent pen, LFpen, and VistaProof fluorescence camera, FC) in detecting demineralization and remineralization on smooth surfaces in situ. Ten volunteers wore acrylic palatal appliances, each containing 6 enamel blocks that were demineralized for 14 days by exposure to a 20% sucrose solution and 3 of them were remineralized for 7 days with fluoride dentifrice. Sixty enamel blocks were evaluated at baseline, after demineralization and 30 blocks after remineralization by two examiners using LF, LFpen and FC. They were submitted to surface microhardness (SMH) and cross-sectional microhardness analysis. The integrated loss of surface hardness (ΔKHN) was calculated. The intraclass correlation coefficient for interexaminer reproducibility ranged from 0.21 (FC) to 0.86 (LFpen). SMH, LF and LFpen values presented significant differences among the three phases. However, FC fluorescence values showed no significant differences between the demineralization and remineralization phases. Fluorescence values for baseline, demineralized and remineralized enamel were, respectively, 5.4 ± 1.0, 9.2 ± 2.2 and 7.0 ± 1.5 for LF; 10.5 ± 2.0, 15.0 ± 3.2 and 12.5 ± 2.9 for LFpen, and 1.0 ± 0.0, 1.0 ± 0.1 and 1.0 ± 0.1 for FC. SMH and ΔKHN showed significant differences between demineralization and remineralization phases. There was a negative and significant correlation between SMH and LF and LFpen in the remineralization phase. In conclusion, LF and LFpen devices were effective in detecting demineralization and remineralization on smooth surfaces provoked in situ.