906 resultados para Molecular diagnostic test


Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Detection of HIV-1 p24 antigen permits early identification of primary HIV infection and timely intervention to limit further spread of the infection. Principally, HIV screening should equally detect all viral variants, but reagents for a standardised test evaluation are limited. Therefore, we aimed to create an inexhaustible panel of diverse HIV-1 p24 antigens. METHODS We generated a panel of 43 recombinantly expressed virus-like particles (VLPs), containing the structural Gag proteins of HIV-1 subtypes A-H and circulating recombinant forms (CRF) CRF01_AE, CRF02_AG, CRF12_BF, CRF20_BG and group O. Eleven 4th generation antigen/antibody tests and five antigen-only tests were evaluated for their ability to detect VLPs diluted in human plasma to p24 concentrations equivalent to 50, 10 and 2 IU/ml of the WHO p24 standard. Three tests were also evaluated for their ability to detect p24 after heat-denaturation for immune-complex disruption, a pre-requisite for ultrasensitive p24 detection. RESULTS Our VLP panel exhibited an average intra-clade p24 diversity of 6.7%. Among the 4th generation tests, the Abbott Architect and Siemens Enzygnost Integral 4 had the highest sensitivity of 97.7% and 93%, respectively. Alere Determine Combo and BioRad Access were least sensitive with 10.1% and 40.3%, respectively. Antigen-only tests were slightly more sensitive than combination tests. Almost all tests detected the WHO HIV-1 p24 standard at a concentration of 2 IU/ml, but their ability to detect this input for different subtypes varied greatly. Heat-treatment lowered overall detectability of HIV-1 p24 in two of the three tests, but only few VLPs had a more than 3-fold loss in p24 detection. CONCLUSIONS The HIV-1 Gag subtype panel has a broad diversity and proved useful for a standardised evaluation of the detection limit and breadth of subtype detection of p24 antigen-detecting tests. Several tests exhibited problems, particularly with non-B subtypes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aimed at evaluating a peak oxygen uptake test as a simple diagnostic tool to assess growth-hormone deficiency (GHD) in adults. Based on the findings of multiple growth hormone (GH) samplings after the exercise, a single GH sample taken 15 min postexercise revealed high accuracy in the diagnosis of GHD in the present study. A standardized peak oxygen uptake test may, therefore, provide an accurate alternative to more invasive tests of GHD.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

IgG autoantibodies against the alpha-chain of the high affinity IgE receptor are claimed to play a pathogenetic role in autoimmune urticaria. The best methods for detection of functional autoantibodies are currently the autologous serum skin test and the basophil histamine release assay. A simplified and feasible screening test would facilitate the diagnosis of autoimmune urticaria. Here we offer an explanation for the difficulties in establishing a screening test for autoantibodies directed against the alpha-chain of the high affinity IgE receptor in autoimmune urticaria. Identical autoantibodies in chronic urticaria patients and healthy donors belonging to the natural autoantibody repertoire were found by sequence analysis of anti-alpha-chain autoantibodies isolated by repertoire cloning from antibody libraries. These natural autoantibodies bound to the receptor and triggered histamine release but only if IgE was previously removed from the receptor. Diagnostic assays used for detection of antibodies directed against the IgE receptor may require signal comparison with and without the artificial removal of IgE, immune complexes, and complement in order to avoid false positive or negative results. After IgE removal diagnostic tests will detect natural autoantibodies against the high affinity IgE receptor regardless of whether they are pathogenic or not.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND General practitioners (GPs) are in best position to suspect dementia. Mini-Mental State Examination (MMSE) and Clock Drawing Test (CDT) are widely used. Additional neurological tests may increase the accuracy of diagnosis. We aimed to evaluate diagnostic ability to detect dementia with a Short Smell Test (SST) and Palmo-Mental Reflex (PMR) in patients whose MMSE and CDT are normal, but who show signs of cognitive dysfunction. METHODS This was a 3.5-year cross-sectional observational study in the Memory Clinic of the University Department of Geriatrics in Bern, Switzerland. Participating patients with normal MMSE (>26 points) and CDT (>5 points) were referred by GPs because they suspected dementia. All were examined according to a standardized protocol. Diagnosis of dementia was based on DSM-IV TR criteria. We used SST and PMR to determine if they accurately detected dementia. RESULTS In our cohort, 154 patients suspected of dementia had normal MMSE and CDT test results. Of these, 17 (11 %) were demented. If SST or PMR were abnormal, sensitivity was 71 % (95 % CI 44-90 %), and specificity 64 % (95 % CI 55-72 %) for detecting dementia. If both tests were abnormal, sensitivity was 24 % (95 % CI 7-50 %), but specificity increased to 93 % (95 % CI 88-97 %). CONCLUSION Patients suspected of dementia, but with normal MMSE and CDT results, may benefit if SST and PMR are added as diagnostic tools. If both SST and PMR are abnormal, this is a red flag to investigate these patients further, even though their negative neuropsychological screening results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Psychological assessment is a central component of applied sport psychology. Despite obvious and well-documented advantages of diagnostic online tools, there is a lack of a system for such tools for sport psychologists so far in Switzerland. Having the most frequently used questionnaires available online in one single tool for all listed Swiss sport psychologists would make the work of practitioners a lot easier and less time consuming. Therefore, the main goal of this project is to develop a diagnostic online tool system with the possibility to make available different questionnaires often used in sport psychology. Furthermore, we intend to survey status and use of this diagnostic online tool system and the questionnaires by Swiss sport psychologists. A specific challenge is to limit the access to qualified sport psychologists and to secure the confidentiality for the client. In particular, approved sport psychologists get an individual code for each of their athletes for the required questionnaire. With the help of this code, athletes can access the test via a secure website at any place of the world. As soon as they complete and submit the online questionnaire, analysed and interpreted data reach the sport psychologist via E-Mail, which is timesaving and easy applicable for the sport psychologist. Furthermore, data are available for interpretation with athletes and documentation of individual development over time is possible. Later on, completed and anonymised questionnaires will be collected and analysed. Bigger number of collected data give more insight in the psychometric properties, thus helping to improve and further develop the questionnaires. In this presentation, we demonstrate the tool and its feasibility using the German version of the Test of Performance Strategies (TOPS, Schmid et al., 2010). To conclude, this diagnostic online tool system offers new possibilities for sport psychologists working as practitioner.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Chronic hepatitis B virus (HBV) infection affects up to 7 % of the European population. Specific HBV genotypes are associated with rapid progression to end-stage liver disease and sub-optimal interferon treatment responses. Although the geographic distribution of HBV genotypes differs between regions, it has not been studied in Switzerland, which lies at the crossroads of Europe. METHODS In a retrospective analysis of 465 HBV samples collected between 2002 and 2013, we evaluated the HBV genotype distribution and phylogenetic determinants, as well as the prevalence of serological evidence of hepatitis delta, hepatitis C and HIV infections in Switzerland. Baseline characteristics of patients were compared across their region of origin using Fisher's exact test and ANOVA, and risk factors for HBeAg positivity were assessed using logistic regression. RESULTS The Swiss native population represented 15.7 % of HBV-infected patients living in Switzerland. In the overall population, genotype D was most prevalent (58.3 %), whereas genotype A (58.9 %) was the predominant genotype among the Swiss native population. The prevalence of patients with anti-HDV antibodies was 4.4 %. Patients of Swiss origin were most likely to be HBeAg-positive (38.1 %). HBV genotypes of patients living in Switzerland but sharing the same original region of origin were consistent with their place of birth. CONCLUSIONS The molecular epidemiology of HBV infection in Switzerland is driven by migration patterns and not by the genotype distribution of the native population. The prevalence of positive anti-HDV antibodies in our cohort was very low.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to test a newly developed LED-based fluorescence device for approximal caries detection in vitro. We assembled 120 extracted molars without frank cavitations or fillings pairwise in order to create contact areas. The teeth were independently assessed by two examiners using visual caries detection (International Caries Detection and Assessment System, ICDAS), bitewing radiography (BW), laser fluorescence (LFpen), and LED fluorescence (Midwest Caries I.D., MW). The measurements were repeated at least 1 week later. The diagnostic performance was calculated with Bayesian analyses. Post-test probabilities were calculated in order to judge the diagnostic performance of combined methods. Reliability analyses were performed using kappa statistics for nominal data and intraclass correlation (ICC) for absolute data. Histology served as the gold standard. Sensitivities/specificities at the enamel threshold were 0.33/0.84 for ICDAS, 0.23/0.86 for BW, 0.47/0.78 for LFpen, and 0.32/0.87 for MW. Sensitivities/specificities at the dentine threshold were 0.04/0.89 for ICDAS, 0.27/0.94 for BW, 0.39/0.84 for LFpen, and 0.07/0.96 for MW. Reliability data were fair to moderate for MW and good for BW and LFpen. The combination of ICDAS and radiography yielded the best diagnostic performance (post-test probability of 0.73 at the dentine threshold). The newly developed LED device is not able to be recommended for approximal caries detection. There might be too much signal loss during signal transduction from the occlusal aspect to the proximal lesion site and the reverse.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

CONTEXT The polyuria-polydipsia syndrome comprises primary polydipsia (PP) and central and nephrogenic diabetes insipidus (DI). Correctly discriminating these entities is mandatory, given that inadequate treatment causes serious complications. The diagnostic "gold standard" is the water deprivation test with assessment of arginine vasopressin (AVP) activity. However, test interpretation and AVP measurement are challenging. OBJECTIVE The objective was to evaluate the accuracy of copeptin, a stable peptide stoichiometrically cosecreted with AVP, in the differential diagnosis of polyuria-polydipsia syndrome. DESIGN, SETTING, AND PATIENTS This was a prospective multicenter observational cohort study from four Swiss or German tertiary referral centers of adults >18 years old with the history of polyuria and polydipsia. MEASUREMENTS A standardized combined water deprivation/3% saline infusion test was performed and terminated when serum sodium exceeded 147 mmol/L. Circulating copeptin and AVP levels were measured regularly throughout the test. Final diagnosis was based on the water deprivation/saline infusion test results, clinical information, and the treatment response. RESULTS Fifty-five patients were enrolled (11 with complete central DI, 16 with partial central DI, 18 with PP, and 10 with nephrogenic DI). Without prior thirsting, a single baseline copeptin level >21.4 pmol/L differentiated nephrogenic DI from other etiologies with a 100% sensitivity and specificity, rendering a water deprivation testing unnecessary in such cases. A stimulated copeptin >4.9 pmol/L (at sodium levels >147 mmol/L) differentiated between patients with PP and patients with partial central DI with a 94.0% specificity and a 94.4% sensitivity. A stimulated AVP >1.8 pg/mL differentiated between the same categories with a 93.0% specificity and a 83.0% sensitivity. LIMITATION This study was limited by incorporation bias from including AVP levels as a diagnostic criterion. CONCLUSION Copeptin is a promising new tool in the differential diagnosis of the polyuria-polydipsia syndrome, and a valid surrogate marker for AVP. Primary Funding Sources: Swiss National Science Foundation, University of Basel.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background. Prenatal diagnosis of Optiz G/BBB syndrome (OS) is challenging because the characteristic clinical features, such as facial and genitourinary anomalies, may be subtle at sonography and rather unspecific. Furthermore, molecular testing of the disease gene is not routinely performed, unless a specific diagnosis is suggested. Method. Both familial and ultrasound data were used to achieve the diagnosis of X-linked OS (XLOS), which was confirmed by molecular testing of MID1 gene (Xp22.3) at birth. Results. Sequencing of MID1 gene disclosed the nucleotide change c.1285 +1 G>T, previously associated with XLOS. Conclusions. This case illustrates current challenges of the prenatal diagnostic work-up of XLOS and exemplifies how clinical investigation, including family history, and accurate US foetal investigations can lead to the correct diagnosis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Immunoassays are essential in the workup of patients with suspected heparin-induced thrombocytopenia. However, the diagnostic accuracy is uncertain with regard to different classes of assays, antibody specificities, thresholds, test variations, and manufacturers. We aimed to assess diagnostic accuracy measures of available immunoassays and to explore sources of heterogeneity. We performed comprehensive literature searches and applied strict inclusion criteria. Finally, 49 publications comprising 128 test evaluations in 15 199 patients were included in the analysis. Methodological quality according to the revised tool for quality assessment of diagnostic accuracy studies was moderate. Diagnostic accuracy measures were calculated with the unified model (comprising a bivariate random-effects model and a hierarchical summary receiver operating characteristics model). Important differences were observed between classes of immunoassays, type of antibody specificity, thresholds, application of confirmation step, and manufacturers. Combination of high sensitivity (>95%) and high specificity (>90%) was found in 5 tests only: polyspecific enzyme-linked immunosorbent assay (ELISA) with intermediate threshold (Genetic Testing Institute, Asserachrom), particle gel immunoassay, lateral flow immunoassay, polyspecific chemiluminescent immunoassay (CLIA) with a high threshold, and immunoglobulin G (IgG)-specific CLIA with low threshold. Borderline results (sensitivity, 99.6%; specificity, 89.9%) were observed for IgG-specific Genetic Testing Institute-ELISA with low threshold. Diagnostic accuracy appears to be inadequate in tests with high thresholds (ELISA; IgG-specific CLIA), combination of IgG specificity and intermediate thresholds (ELISA, CLIA), high-dose heparin confirmation step (ELISA), and particle immunofiltration assay. When making treatment decisions, clinicians should be a aware of diagnostic characteristics of the tests used and it is recommended they estimate posttest probabilities according to likelihood ratios as well as pretest probabilities using clinical scoring tools.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The vertebrate thyroid system is important for multiple developmental processes, including eye development. Thus, its environmentally induced disruption may impact important fitness-related parameters like visual capacities and behaviour. The present study investigated the relation between molecular effects of thyroid disruption and morphological and physiological changes of eye development in zebrafish (Danio rerio). Two test compounds representing different molecular modes of thyroid disruption were used: propylthiouracil (PTU), which is an enzyme-inhibitor of thyroid hormone synthesis, and tetrabromobisphenol A (TBBPA), which interacts with the thyroid hormone receptors. Both chemicals significantly altered transcript levels of thyroid system-related genes (TRα, TRβ, TPO, TSH, DIO1, DIO2 and DIO3) in a compound-specific way. Despite these different molecular response patterns, both treatments resulted in similar pathological alterations of the eyes such as reduced size, RPE cell diameter and pigmentation, which were concentration-dependent. The morphological changes translated into impaired visual performance of the larvae: the optokinetic response was significantly and concentration-dependently decreased in both treatments, together with a significant increase of light preference of PTU-treated larvae. In addition, swimming activity was impacted. This study provides first evidence that different modes of molecular action of the thyroid disruptors can be associated with uniform apical responses. Furthermore, this study is the first to show that pathological eye development, as it can be induced by exposure to thyroid disruptors, indeed translates into impaired visual capacities of zebrafish early life stages.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Primary ciliary dyskinesia is a rare heterogeneous recessive genetic disorder of motile cilia, leading to chronic upper and lower respiratory symptoms. Prevalence is estimated at around 1:10,000, but many patients remain undiagnosed, while others receive the label incorrectly. Proper diagnosis is complicated by the fact that the key symptoms such as wet cough, chronic rhinitis and recurrent upper and lower respiratory infection, are common and nonspecific. There is no single gold standard test to diagnose PCD. Presently, the diagnosis is made by augmenting the medical history and physical examination with in patients with a compatible medical history following a demanding combination of tests including nasal nitric oxide, high- speed video microscopy, transmission electron microscopy, genetics, and ciliary culture. These tests are costly and need sophisticated equipment and experienced staff, restricting use to highly specialised centers. Therefore, it would be desirable to have a screening test for identifying those patients who should undergo detailed diagnostic testing. Three recent studies focused on potential screening tools: one paper assessed the validity of nasal nitric oxide for screening, and two studies developed new symptom-based screening tools. These simple tools are welcome, and hopefully remind physicians whom to refer for definitive testing. However, they have been developed in tertiary care settings, where 10 to 50% of tested patients have PCD. Sensitivity and specificity of the tools are reasonable, but positive and negative predictive values may be poor in primary or secondary care settings. While these studies take an important step forward towards an earlier diagnosis of PCD, more remains to be done before we have tools tailored to different health care settings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Diagnosis of primary ciliary dyskinesia (PCD) lacks a "gold standard" test and is therefore based on combinations of tests including nasal nitric oxide (nNO), high-speed video microscopy analysis (HSVMA), genotyping and transmission electron microscopy (TEM). There are few published data on the accuracy of this approach.Using prospectively collected data from 654 consecutive patients referred for PCD diagnostics we calculated sensitivity and specificity for individual and combination testing strategies. Not all patients underwent all tests.HSVMA had excellent sensitivity and specificity (100% and 93%, respectively). TEM was 100% specific, but 21% of PCD patients had normal ultrastructure. nNO (30 nL·min(-1) cut-off) had good sensitivity and specificity (91% and 96%, respectively). Simultaneous testing using HSVMA and TEM was 100% sensitive and 92% specific.In conclusion, combination testing was found to be a highly accurate approach for diagnosing PCD. HSVMA alone has excellent accuracy, but requires significant expertise, and repeated sampling or cell culture is often needed. TEM alone is specific but misses 21% of cases. nNO (≤30 nL·min(-1)) contributes well to the diagnostic process. In isolation nNO screening at this cut-off would miss ∼10% of cases, but in combination with HSVMA could reduce unnecessary further testing. Standardisation of testing between centres is a future priority.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Identifying and characterizing the genes responsible for inherited human diseases will ultimately lead to a more holistic understanding of disease pathogenesis, catalyze new diagnostic and treatment modalities, and provide insights into basic biological processes. This dissertation presents research aimed at delineating the genetic and molecular basis of human diseases through epigenetic and functional studies and can be divided into two independent areas of research. The first area of research describes the development of two high-throughput melting curve based methods to assay DNA methylation, referred to as McMSP and McCOBRA. The goal of this project was to develop DNA methylation methods that can be used to rapidly determine the DNA methylation status at a specific locus in a large number of samples. McMSP and McCOBRA provide several advantages over existing methods, as they are simple, accurate, robust, and high-throughput making them applicable to large-scale DNA methylation studies. McMSP and McCOBRA were then used in an epigenetic study of the complex disease Ankylosing spondylitis (AS). Specifically, I tested the hypothesis that aberrant patterns of DNA methylation in five AS candidate genes contribute to disease susceptibility. While no statistically significant methylation differences were observed between cases and controls, this is the first study to investigate the hypothesis that epigenetic variation contributes to AS susceptibility and therefore provides the conceptual framework for future studies. ^ In the second area of research, I performed experiments to better delimit the function of aryl hydrocarbon receptor-interacting protein-like 1 (AIPL1), which when mutated causes various forms of inherited blindness such as Leber congenital amaurosis. A yeast two-hybrid screen was performed to identify putative AIPL1-interacting proteins. After screening 2 × 106 bovine retinal cDNA library clones, 6 unique putative AIPL1-interacting proteins were identified. While these 6 AIPL1 protein-protein interactions must be confirmed, their identification is an important step in understanding the functional role of AIPL1 within the retina and will provide insight into the molecular mechanisms underlying inherited blindness. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Hematopoietic growth factors play important roles in regulating blood cell growth and development in vivo. In this work, we investigated the signaling mechanisms of two growth factors with clinical significance, erythropoietin (Epo) and granulocyte colony-stimulating factor (G-CSF). Epo is essential for the survival, proliferation and differentiation of red blood cell progenitors, while G-CSF plays an important role in controlling mature neutrophil production. To identify which amino acid(s) and/or motif in EpoR is responsible for cell survival, wild type or mutant EpoR isoforms were transfected into the growth factor-dependent 32D cell line. Proliferation and apoptosis assays demonstrated that an EpoR isoform that lacks intracellular tyrosine residues and is truncated after 321 amino acids in the cytoplasmic tail (EpoR 1-321) mediates Epo-dependent cell survival. Furthermore, in absence of fetal calf serum (FCS), Epo signaling through wild type or mutant receptors supported anti-apoptosis, but not proliferation during 72 hours in response to Epo. To investigate the signaling pathway by which EpoR regulates cell survival, a dominant negative Stat5b (dnStat5b) isoform was generated and coexpressed with EpoR in stable cell lines. Expression of dnStat5b causes a significant induction of apoptosis in the presence of Epo in cells expressing EpoR 1-321, indicating that Stat5 is essential for survival signaling through tyrosine independent sequences in the EpoR. In a second project to investigate G-CSF signaling, we studied mechanisms by which G-CSF regulates the expression of PU.1, an important transcription factor in myeloid and B cell development. We demonstrated, by immunoblot and real time RT-PCR, that PU.1 is induced by G-CSF ex vivo as well as in vivo. To test whether G-CSF signaling through Stat3 is required for PU.1 regulation, the upstream region of the PU.1 gene was analyzed for potential Stat3 binding motifs. Four potential sites were identified; chromatin immunoprecipitations demonstrated that G-CSF activated Stat3 binds to 3 of the 4 binding motifs. In addition, PU.1 induction by G-CSF was completely abrogated in bone marrow from hematopoietic conditional Stat3 knockout mice. These results indicate an important role for Stat3 in G-CSF-dependent PU.1 gene regulation. Collectively, our works demonstrate that Stat protein play important and diverse roles in hematopoietic growth factor signaling. ^