943 resultados para Metallic Nanowires


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this implant study was to evaluate the transverse stability of the basal maxillary and mandibular structures. The sample included 25 subjects between 12 and 18 years of age who were followed for approximately 2.6 years. Metallic implants were placed bilaterally into the maxillary and mandibular corpora before treatment. Once implant stability had been confirmed, treatment (4 first premolar extractions followed by fixed appliance therapy) was initiated. Changes in the transverse maxillary and mandibular implants were evaluated cephalometrically and two groups (GROW+ and GROW++; selection based on growth changes in facial height and mandibular length) were compared. The GROW++ group showed significant width increases of the posterior maxillary implants (P <.001) and the mandibular implants (P =.009); there was no significant change for the anterior maxillary implants. The GROW+ group showed no significant width changes between the maxillary and mandibular implants. We conclude that (1) there are significant width increases during late adolescence of the basal mandibular and maxillary skeletal structures and (2) the width changes are related with growth potential.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents an investigation into the use of the finite element method and artificial neural networks in the identification of defects in industrial plants metallic tubes, due to the aggressive actions of the fluids contained by them, and/or atmospheric agents. The methodology used in this study consists of simulating a very large number of defects in a metallic tube, using the finite element method. Both variations in width and height of the defects are considered. Then, the obtained results are used to generate a set of vectors for the training of a perceptron multilayer artificial neural network. Finally, the obtained neural network is used to classify a group of new defects, simulated by the finite element method, but that do not belong to the original dataset. The reached results demonstrate the efficiency of the proposed approach, and encourage future works on this subject.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work is to characterize a metallic slurry (Al-4.5%Cu) flow during thixoforming of an automotive valve. The necessary globular structure was obtained by first inoculating the alloy with TIBAL (5%Ti, 1%B, Al - rest) at 750.0°C, and then reheating to a state between liquidus and solidus prior to thixoforming. Two metallic slurries, with a solid phase of approximately 86.1 and 78.2 percent, were used to generate different experimental flow patterns during the thixoforming process. The flow of the material into the die was observed for total, and partial displacement (2.7, 5.4, 7.5mm) of the punch. The first displacement shows formation of the valve rod. The patterns at each step of displacement of the punch were preserved by quenching in water, thus revealing the profile of the die fill and microstructural evolution. Degeneration of the globular phase was observed along the piece thixoextruded. Thixoextrusion forces versus time curves were generated for partial and full displacement of the punch. Porosity was visible along the billet prior to thixoforming. However, some areas show that the porosity gradually decreased to zero as the thixoextrusion pressure increased. Turbulent, transient and laminar flow are analyzed in this work.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors have investigated strain relaxation in InAsInGaAsInP nanowires (NW's). Transmission electron microscopy images show an additional stress field attributed to compositional modulation in the ternary layer, which disrupts NW formation and drives Ga interdiffusion into InAs, according to grazing incidence x-Ray diffraction under anomalous scattering conditions. The strain profile along the NW, however, is not significantly affected when interdiffusion is considered. Results show that the InAs NW energetic stability is preserved with the introduction of ternary buffer layer in the structure. © 2007 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The complexation capacity of humic substances extracted from peat samples taken from the Mogi River in Ribeirao Preto, SP, Brazil, was determined using metal ions (Al(III), Pb(II), Cr(VI) and Cd(II)), yielding the following order of affinity: Cr(VI)< Cd(II)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of the present study was to evaluate in vivo the failure rate of metallic brackets bonded with two orthodontic composites. Nineteen patients with ages ranging from 10.5 to 38.7 years needing corrective orthodontic treatment were selected for study. The enamel surfaces from second premolars to second premolars were treated with Transbond Plus-Self Etching Primer (3M Unitek). Next, 380 orthodontic brackets were bonded on maxillary and mandibular teeth, as follows: 190 with Transbond XT composite (3M Unitek) (control) and 190 with Transbond Plus Color Change (3M Unitek) (experimental) in contralateral quadrants. The bonded brackets were light cured for 40 s, and initial alignment archwires were inserted. Bond failure rates were recorded over a six-month period. At the end of the evaluation, six bond failures occurred, three for each composite. Kaplan-Meyer method and log-rank test (Mantel-Cox) was used for statistical analysis, and no statistically significant difference was found between the materials (p=0.999). Both Transbond XT and Transbond Plus Color Change composites had low debonding rates over the study period.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have prepared heavy metal oxide glasses containing metallic copper nanoparticles with promising nonlinear optical properties which were determined by Z-scan and pump-probe measurements using femtosecond laser pulses. For the wavelengths within the plasmon band, we have observed saturable absorption and response times of 2.3 ps. For the other regions of the spectrum, reverse saturable absorption and lifetimes shorter than 200 fs were verified. The nonlinear refractive index is about 2.0 × 10-19 m2/W from visible to telecom region, thus presenting an enhancement effect at wavelengths near the plasmon and Cu+2 d-d band. © 2013 Springer Science+Business Media New York.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The correlative light-electron fractography technique combines correlative microscopy concepts to the extended depth-from-focus reconstruction method, associating the reliable topographic information of 3-D maps from light microscopy ordered Z-stacks to the finest lateral resolution and large focus depth from scanning electron microscopy. Fatigue striations spacing analysis can be precisely measured, by correcting the mean surface tilting with the knowledge of local elevation data from elevation maps. This new technique aims to improve the accuracy of quantitative fractography in fatigue fracture investigations. Microsc. Res. Tech. 76:909-913, 2013. © 2013 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The vortex matter in a superconducting disk with a linear configuration of metallic and superconducting defects is studied. Effects associated to the pinning (anti-pinning) force of the metallic (superconducting) defect on the vortex configuration and on the thermodynamic critical fields are analyzed in the framework of the Ginzburg Landau theory. We calculate the loop of the magnetization, vorticity and free energy curves as a function of the magnetic field for a thin disk. Due to vortex-defect attraction for a metallic defect (repulsion for a superconducting defect), the vortices always (never) are found to be sitting on the defect position. © 2013.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Motivados por estudos experimentais acerca de monocamadas de metais de transição 3d sobre superfícies de Pd, nesta dissertação investigamos o complexo magnetismo de nanoestruturas, embebidas ou adsorvidas, em superfícies metálicas através de cálculos de primeiros princípios. Utilizamos o método RS-LMTO-ASA (Real Space - Linear MuffinTin Orbital - Atomic Sphere Approximation), o qual é baseado na teoria do funcional da densidade (DFT - Density Functional Theory) e implementado para o cálculo de estruturas magnéticas não colineares. Com este propósito, investigamos nanoestruturas embebidas e ligas (2 x 2) de metais 3d (Cr, Mn, Fe, Co e Ni) na superfície Pd (110), além de nanoestruturas de Cr adsorvidas sobre a superfície de Pd (111). Primeiro, para as nanoestruturas embebidas na superfície Pd (110), analisamos a variação do momento magnético de spin orbital com relação ao número de vizinhos e de valência dos metais 3d. Também mostramos que estas estruturas têm ordenamento magnético colinear, exceto as de Cr e Mn, que apresentam magnetismo não colinear associado à frustração geométrica. Para o caso de nanofios de Cr adsorvidos sobre a superfície de Pd (111), verificamos uma configuração colinear antiferromagnética para cadeias com até 9 átomos. Para o nanofio com 10 átomos obtivemos uma configuração tipo antiferromagnética inclinada (canted). No caso de nanoestruturas de Cr bidimensionais, verificamos complexas configurações magnéticas não colineares com diferentes quiralidades.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neste trabalho, utilizamos o método de primeiros princípios RS-LMTO-ASA (Real Space – Linear Muffin-Tin Orbital - Atomic Sphere Approximation) baseado na Teoria do Funcional da Densidade (DFT - Density Functional Theory) e implementado para o cálculo de estruturas magnéticas não-colineares, para investigar as propriedades magnéticas de nanoestruturas adsorvidas em superfícies metálicas. Consideramos aglomerados com diferentes geometrias e tamanhos como adátomos, dímeros, trímeros, nanofios e nanoestruturas de geometria triangular de Fe, Fe-Co e Fe-Pt adsorvidos sobre a superfície de Pt(111) e tratamos também nanoestruturas de Mn sobre a superfície de Ag(111). Mostramos que os nanofios de Fe-Co sobre a superfície de Pt(111) apresentam um ordenamento ferromagnético. Devido à redução do número de coordenação presente na superfície, os momentos de spin e orbital nos sítios de Fe e Co mostram-se elevados comparados com os respectivos valores dos momentos destes metais como bulk. Analisamos também como estes momentos variam em função da concentração destes elementos nos nanofios. Para os sistemas compostos por nanofios Fe-Pt adsorvidos em Pt(111), mostramos que é possível sintonizar as interações de troca entre os adátomos magnéticos Fe através da introdução de um diferente número de átomos Pt para ligá-los. Por exemplo, a interação de troca entre os adátomos de Fe pode ser consideravelmente aumentada pela introdução de cadeias de Pt que os conectem e tanto configurações ferromagnéticas, antiferromagnéticas ou não-colineares entre os adátomos de Fe podem ser estabilizadas, dependendo da espessura do espaçador Pt. Para os aglomerados Mn sobre a Ag(111) mostramos que a interação de troca entre os sítios de Mn depende não somente da distância entre os átomos, mas também do número de coordenação de cada sítio. Desta forma, verificamos um magnetismo não-colinear nestas nanoestruturas causado tanto por frustração geométrica, quanto pela competição de interações de curto e longo alcance. Nossos resultados estão em boa concordância com os resultados experimentais da literatura e com os resultados teóricos obtidos por outros métodos, quando existentes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: avaliar, in vitro, a influência do clareamento dentário com gel contendo fosfato de cálcio amorfo (ACP) na resistência da união adesiva de braquetes metálicos. MÉTODOS: trinta e seis dentes incisivos bovinos foram seccionados no limite coronorradicular e tiveram suas coroas incluídas em cilindros de PVC. Os corpos de prova foram divididos em três grupos (n = 12), de acordo com a realização do tratamento clareador e tipo de gel utilizado, sendo: G1 (controle) - sem clareamento; G2 - clareamento com gel sem ACP (Whiteness Perfect, FGM); G3 - clareamento com gel contendo ACP (Nite White ACP, Discus Dental). Os grupos G2 e G3 foram submetidos a 14 ciclos de clareamento, seguidos de intervalo de espera de 15 dias para a fixação adesiva dos braquetes metálicos. O ensaio mecânico de cisalhamento foi realizado em máquina universal Kratos, com velocidade de 0,5mm/min. Após o teste mecânico, os corpos de prova foram avaliados quanto ao índice de remanescente adesivo (ARI). Os resultados foram submetidos à ANOVA, ao teste de Tukey e ao de Kruskall-Wallis (α = 5%). RESULTADOS: diferenças significativas foram observadas entre os grupos testados. O grupo controle G1 (11,1MPa) mostrou uma resistência ao cisalhamento estatisticamente superior aos grupos submetidos ao clareamento (G2 = 5,40MPa; G3 = 3,73MPa), os quais não diferiram entre si. Não se observou diferença significativa para o ARI entre os grupos estudados. CONCLUSÃO: o clareamento dentário reduz a resistência da união adesiva de braquetes metálicos, enquanto a presença de ACP no gel clareador não influencia os resultados encontrados.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: avaliar in vitro a degradação iônica e corrosão do fundo do slot de braquetes metálicos submetidos à escovação com dentifrícios, realizando análises da composição química por Espectroscopia de Energia Dispersiva (EDS) e qualitativa por Microscopia Eletrônica de Varredura (MEV). MÉTODOS: foram selecionados 38 braquetes divididos aleatoriamente em quatro grupos experimentais (n = 7). Dois grupos (n = 5) funcionaram como controles positivo e negativo. Aparelhos ortodônticos simulados foram confeccionados com fios de aço inoxidável 0,019" x 0,025" e anéis elastoméricos. Os grupos foram divididos de acordo com o tratamento de superfície: G1 (Máxima Proteção Anticáries®); G2 (Total 12®); G3 (Sensitive®); G4 (Branqueador®); Controle Positivo (saliva artificial) e Controle Negativo (sem tratamento). Foram realizados 28 ciclos de escovação e avaliações antes (T0) e após (T1) o experimento. RESULTADOS: o teste de Wilcoxon indicou não existir diferença nas concentrações iônicas de titânio (Ti), cromo (Cr), ferro (Fe) e níquel (Ni) entre os grupos. O grupo G2 apresentou redução significativa (p < 0,05) na concentração do íon alumínio (Al) e os grupos G3 e G4 apresentaram aumento significativo (p < 0,05) nas concentrações do íon alumínio. A análise em MEV mostrou aumento nas características indicativas de corrosão dos grupos G2, G3 e G4. CONCLUSÃO: a análise por EDS revelou que os grupos controle e G1 não sofreram alterações na composição química. O grupo G2 apresentou degradação na quantidade de íons Al, e G3 e G4 sofreram aumento na concentração de Al. A imersão em saliva artificial e o dentifrício Máxima Proteção Anticáries® não alteraram o polimento de superfície. Os dentifrícios Total 12®, Sensitive® e Branqueador® alteraram o polimento de superfície.