982 resultados para Llull, Ramon, 1232 o 3-1315 o 6


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study arose from the need to determine inorganic arsenic (iAs) at low levels in cereal-based food. Validated methods with a low limit of detection (LOD) are required to analyse these kinds of food. An analytical method for the determination of iAs, methylarsonic acid (MA) and dimethylarsinic acid (DMA) in cereal-based food and infant cereals is reported. The method was optimised and validated to achieve low LODs. Ion chromatography-inductively coupled plasma mass spectrometry (LC-ICPMS) was used for arsenic speciation. The main quality parameters were established. To expand the applicability of the method, different cereal products were analysed: bread, biscuits, breakfast cereals, wheat flour, corn snacks, pasta and infant cereals. The total and inorganic arsenic content of 29 cereal-based food samples ranged between 3.7-35.6 and 3.1-26.0 microg As kg-1, respectively. The present method could be considered a valuable tool for assessing inorganic arsenic contents in cereal-based foods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The caja (Spondias mombin L.) is used in the manufacture of ice-cream, jams, pulps, beverages being also consumed in natura. One of the most important procedures in food conservation is drying, considering that most fresh fruits contain approximately 80% of water. Food drying is used to obtain two basic aspects: (1) the economic factor; in the shipping and handling of the product; (2) at the manipulation; once dried and grinded, the material is rehydrated, at desirable levels, to formulate a new product as in ice cream, jams, yoghurts and drinks and may also be added to pasta, biscuits and other industrialized products. The aim of this study was to investigate the kinetics of caja bagasse drying in a fixed-bed tray dryer, using central composite factorial planning. The following factors were evaluated: temperature (55, 65 and 75 ºC), dryer inlet air velocity (3.2, 4.6 and 6.0 m.s-1) and cake thickness (0.8, 1.2 and 1.6 cm) where the response of the considered variable was caja bagasse moisture content (b.s.) and the results showed that the main effects and their interactions were significant at a 95% confidence level being the best condition obtained at temperature of 75 ºC, velocity of 6.0 m.s-1 and cake thickness of 0.8 cm.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Second line endocrine therapy has limited antitumour activity. Fulvestrant inhibits and downregulates the oestrogen receptor. The mitogen-activated protein kinase (MAPK) pathway is one of the major cascades involved in resistance to endocrine therapy. We assessed the efficacy and safety of fulvestrant with selumetinib, a MEK 1/2 inhibitor, in advanced stage breast cancer progressing after aromatase inhibitor (AI). PATIENTS AND METHODS: This randomised phase II trial included postmenopausal patients with endocrine-sensitive breast cancer. They were ramdomised to fulvestrant combined with selumetinib or placebo. The primary endpoint was disease control rate (DCR) in the experimental arm. ClinicalTrials.gov Indentifier: NCT01160718. RESULTS: Following the planned interim efficacy analysis, recruitment was interrupted after the inclusion of 46 patients (23 in each arm), because the selumetinib-fulvestrant arm did not reach the pre-specified DCR. DCR was 23% (95% confidence interval (CI) 8-45%) in the selumetinib arm and 50% (95% CI 27-75%) in the placebo arm. Median progression-free survival was 3.7months (95% CI 1.9-5.8) in the selumetinib arm and 5.6months (95% CI 3.4-13.6) in the placebo arm. Median time to treatment failure was 5.1 (95% CI 2.3-6.7) and 5.6 (95% CI 3.4-10.2) months, respectively. The most frequent treatment-related adverse events observed in the selumetinib-fulvestrant arm were skin disorders, fatigue, nausea/vomiting, oedema, diarrhoea, mouth disorders and muscle disorders. CONCLUSIONS: The addition of selumetinib to fulvestrant did not show improving patients' outcome and was poorly tolerated at the recommended monotherapy dose. Selumetinib may have deteriorated the efficacy of the endocrine therapy in some patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Clinical experience and experimental data suggest that intradialytic hemodynamic profiles could be influenced by the characteristics of the dialysis membranes. Even within the worldwide used polysulfone family, intolerance to specific membranes was occasionally evoked. The aim of this study was to compare hemodynamically some of the commonly used polysulfone dialyzers in Switzerland. We performed an open-label, randomized, cross-over trial, including 25 hemodialysis patients. Four polysulfone dialyzers, A (Revaclear high-flux, Gambro, Stockholm, Sweden), B (Helixone high-flux, Fresenius), C (Xevonta high-flux, BBraun, Melsungen, Germany), and D (Helixone low-flux, Fresenius, Bad Homburg vor der Höhe, Germany), were compared. The hemodynamic profile was assessed and patients were asked to provide tolerance feedback. The mean score (±SD) subjectively assigned to dialysis quality on a 1-10 scale was A 8.4 ± 1.3, B 8.6 ± 1.3, C 8.5 ± 1.6, D 8.5 ± 1.5. Kt/V was A 1.58 ± 0.30, B 1.67 ± 0.33, C 1.62 ± 0.32, D 1.45 ± 0.31. The low- compared with the high-flux membranes, correlated to higher systolic (128.1 ± 13.1 vs. 125.6 ± 12.1 mmHg, P < 0.01) and diastolic (76.8 ± 8.7 vs. 75.3 ± 9.0 mmHg; P < 0.05) pressures, higher peripheral resistance (1.44 ± 0.19 vs. 1.40 ± 0.18 s × mmHg/mL; P < 0.05) and lower cardiac output (3.76 ± 0.62 vs. 3.82 ± 0.59 L/min; P < 0.05). Hypotension events (decrease in systolic blood pressure by >20 mmHg) were 70 with A, 87 with B, 73 with C, and 75 with D (P < 0.01 B vs. A, 0.05 B vs. C and 0.07 B vs. D). The low-flux membrane correlated to higher blood pressure levels compared with the high-flux ones. The Helixone high-flux membrane ensured the best efficiency. Unfortunately, the very same dialyzer correlated to a higher incidence of hypotensive episodes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

CONTEXT: The current standard for diagnosing prostate cancer in men at risk relies on a transrectal ultrasound-guided biopsy test that is blind to the location of the cancer. To increase the accuracy of this diagnostic pathway, a software-based magnetic resonance imaging-ultrasound (MRI-US) fusion targeted biopsy approach has been proposed. OBJECTIVE: Our main objective was to compare the detection rate of clinically significant prostate cancer with software-based MRI-US fusion targeted biopsy against standard biopsy. The two strategies were also compared in terms of detection of all cancers, sampling utility and efficiency, and rate of serious adverse events. The outcomes of different targeted approaches were also compared. EVIDENCE ACQUISITION: We performed a systematic review of PubMed/Medline, Embase (via Ovid), and Cochrane Review databases in December 2013 following the Preferred Reported Items for Systematic reviews and Meta-analysis statement. The risk of bias was evaluated using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. EVIDENCE SYNTHESIS: Fourteen papers reporting the outcomes of 15 studies (n=2293; range: 13-582) were included. We found that MRI-US fusion targeted biopsies detect more clinically significant cancers (median: 33.3% vs 23.6%; range: 13.2-50% vs 4.8-52%) using fewer cores (median: 9.2 vs 37.1) compared with standard biopsy techniques, respectively. Some studies showed a lower detection rate of all cancer (median: 50.5% vs 43.4%; range: 23.7-82.1% vs 14.3-59%). MRI-US fusion targeted biopsy was able to detect some clinically significant cancers that would have been missed by using only standard biopsy (median: 9.1%; range: 5-16.2%). It was not possible to determine which of the two biopsy approaches led most to serious adverse events because standard and targeted biopsies were performed in the same session. Software-based MRI-US fusion targeted biopsy detected more clinically significant disease than visual targeted biopsy in the only study reporting on this outcome (20.3% vs 15.1%). CONCLUSIONS: Software-based MRI-US fusion targeted biopsy seems to detect more clinically significant cancers deploying fewer cores than standard biopsy. Because there was significant study heterogeneity in patient inclusion, definition of significant cancer, and the protocol used to conduct the standard biopsy, these findings need to be confirmed by further large multicentre validating studies. PATIENT SUMMARY: We compared the ability of standard biopsy to diagnose prostate cancer against a novel approach using software to overlay the images from magnetic resonance imaging and ultrasound to guide biopsies towards the suspicious areas of the prostate. We found consistent findings showing the superiority of this novel targeted approach, although further high-quality evidence is needed to change current practice.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The study assessed growth and physiological parameters of 'Sunrise Golden' and 'Tainung 01' papaya seedlings grown in 280mL plastic tubes and watered using a low-cost automatic irrigation system adjusted to operate at substrate water tension for starting irrigation (STI) of 3.0, 6.0 or 9.0 kPa. The water depths applied by the dripping system and drainage were monitored during germination and seedling growth. Germination, emergence velocity index (EVI), leaf area, plant height, shoot and root dry weight, stomatal conductance, relative water content (RWC) and relative chlorophyll content (RCC) were evaluated. Soil nutrient levels were determined by electrical conductivity (EC). Water use efficiency (WUE) corresponded to the ratio of plant dry mass to depth of water applied. STI settings did not affect papaya germination or EVI. System configuration to 3.0 and 6.0 kPa STI exhibited the highest drainage and lowest EC and RCC, indicating soil nutrient loss and plant nutrient deficiency. Drainage was greater in tubes planted with the 'Tainung 01' variety, which developed smaller root systems and lower stomatal conductance than 'Sunrise Golden' seedlings. The highest values for shoot dry weight and WEU were obtained at 6.0 kPa STI for 'Sunrise Golden' (0.62 g and 0.69 g L-1) and at 9.0 kPa in 'Tainung 01' (0.35 g and 0.82 g L-1). RWC at 9.0 kPa STI was lower than at 3.0 kPa in both varieties. The results indicate that the low-cost technology developed for irrigation automation is promising. Even so, new studies are needed to evaluate low-flow irrigation systems as well as the nutrient and water needs of different papaya varieties.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O objetivo foi avaliar o efeito dos herbicidas diuron, ametryn e sulfentrazone, e da associação micorrízica na eficiência quântica do fotossistema II de mudas de abacaxizeiro 'Imperial'. Foi utilizado o esquema de parcela subdividida, tendo na parcela o fatorial 2 x 4, sendo dois tipos de mudas: inoculadas com P. indica e sem inoculação, e quatro doses de herbicidas: 0; 1,5; 3,0 e 6,0 L ha-1 para o ametryn, 0; 1,6; 3,2 e 6,4 L ha-1 para o diuron e 0; 0,4; 0,8 e 1,6 L ha-1 para o sulfentrazone, e na subparcela as épocas de avaliação, distribuídos no delineamento inteiramente casualizado, com três repetições. Os herbicidas foram aplicados ao substrato antes do plantio das mudas. A inoculação com o fungo P. indica foi feita no momento do plantio. A avaliação da eficiência quântica foi feita por meio da razão de fluorescência da clorofila a (Fv/Fm), determinada aos 60; 90 e 120 dias após o plantio das mudas, obtendo-se a fluorescência inicial, máxima, e variável. Os dados obtidos foram submetidos à análise de variância e regressão polinomial. O herbicida ametryn não comprometeu a eficiência do fotossistema II das mudas de abacaxizeiro inoculadas com o fungo P. indica. A inoculação com fungo P. indica aumentou a eficiência do fotossistema II das mudas. A aplicação dos herbicidas diuron e sulfentrazone em doses elevadas reduziu a eficiência do fotossistema II de mudas de abacaxizeiro 'Imperial' não inoculadas com o fungo P. indica.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: The aims of the study were to evaluate the prevalence of acute coronary syndrome (ACS) among patients presenting with atypical chest pain who are evaluated for acute aortic syndrome (AAS) or pulmonary embolism (PE) with computed tomoangiography (CTA) and discuss the rationale for the use of triple rule-out (TRO) protocol for triaging these patients. METHODS: This study is a retrospective analysis of patients presenting with atypical chest pain and evaluated with thoracic (CTA), for suspicion of AAS/PE. Two physicians reviewed patient files for demographic characteristics, initial CT and final clinical diagnosis. Patients were classified according to CTA finding into AAS, PE and other diagnoses and according to final clinical diagnosis into AAS, PE, ACS and other diagnoses. RESULTS: Four hundred and sixty-seven patients were evaluated: 396 (84.8%) patients for clinical suspicion of PE and 71 (15.2%) patients for suspicion of AAS. The prevalence of ACS and AAS was low among the PE patients: 5.5% and 0.5% respectively (P = 0.0001), while the prevalence of ACS and PE was 18.3% and 5.6% among AAS patients (P = 0.14 and P = 0.34 respectively). CONCLUSION: The prevalence of ACS and AAS among patients suspected clinically of having PE is limited while the prevalence of ACS and PE among patients suspected clinically of having AAS is significant. Accordingly patients suspected for PE could be evaluated with dedicated PE CTA while those suspected for AAS should still be triaged using TRO protocol.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Wood mice of the genus Apodemus are widely distributed in Eurasia, with the Eastern Mediterranean being considered as a hotspot. Indeed, numerous species have been documented in Iran, including A. witherbyi, A. hyrcanicus, A. uralensis, A. avicennicus, A. hermonensis, and A. arianus. In this study, 129 specimens were collected from different Iranian localities and two specimens from Afghanistan. The animals were identified taxonomically and their phylogenetic relationships were investigated using cytochrome b mitochondrial DNA sequences. Five species of the genus Apodemus were identified in Iran, including A. hyrcanicus, A. witherbyi, A. cf. ponticus, A. uralensis, and A. mystacinus, beside, A. pallipes from Afghanistan. This study found no evidence of A. flavicollis or A. sylvaticus in Iran, despite their occurrence in Turkey, shedding doubt on the status of A. flavicollis in Iran, Asia Minor, and the Levant. Phylogenetic analyses imply that A. witherbyi has priority over A. avicennicus, A. hermonensis, and A. iconicus. Estimation of the divergence time for these taxa suggests a separation at around 7.2 Ma for the subgenera Karstomys (including A. mystacinus and A. epimelas) and Sylvaemus (including A. flavicollis, A. sylvaticus, A. uralensis, A. pallipes, A. hyrcanicus, A. witherbyi, and A. cf. ponticus). Within the subgenus Karstomys, the divergence times for A. mystacinus and A. epimelas were between 3.0 and 6.1 Ma, and divergence times within the subgenus Sylvaemus were between 5.2 and 6.9 Ma for A. witherbyi and other species in this subgenus. It is postulated that vicariance events including the uplifting of the Zagros Mountains and Anatolian Plateau in the middle Miocene and climate oscillations during the Messinian Salinity Crisis besides formation of the Hyrcanian tertiary forests during the Neogene probably played substantial roles in the radiation and distribution of the genus Apodemus in the Eastern Mediterranean.