903 resultados para Lethal dose
Resumo:
IgA nephropathy, one of the most frequent forms of glomerulonephritis, characterized by mesangial hypercellularity and glomerular extracellular matrix (ECM) expansion, often leads to end-stage renal disease over a prolonged period. We investigated whether antiproliferative treatment in a single low dose specifically targeted to the glomerular mesangium by immunoliposomes (ILs) results in an amelioration of mesangial proliferative glomerulonephritis in rats (anti-Thy1.1 nephritis). Mycophenolate mofetil (MMF) containing ILs was generated that targets the Thy1.1 antigen (OX-7) in rat mesangial cells. Treatment benefit of a single intravenous dose of these ILs given 2 days after disease induction was investigated by stereology, immunohistochemistry, and functional analyses (creatinine, albuminuria) until day +9 and was compared among untreated and free MMF-treated rats using six male Wistar rats per group. MMF-loaded OX7-IL prevented creatinine increase and albuminuria. Stereological analyses of MMF OX7-IL-treated animals yielded 30% reduction of mesangial cells on day +9 and a 40% reduction of glomerular ECM volume on day +5, compared with all of the other nephritic animals. Furthermore, at days +5 and +9 we observed decreased ECM content and decreased glomerular volume (day +5) in the MMF-OX7-IL-treated group compared with the nephritic group treated with free MMF. In conclusion, MMF-OX7-IL-based directed drug delivery represents a novel approach for treating mesangial cell-mediated forms of glomerulonephritis.
Resumo:
Apart from its role in bone metabolism, vitamin D may also influence cardiovascular disease. The objective of this study was: (1) to determine the effect of a single, oral, high-dose vitamin D supplementation on endothelial function and arterial stiffness in patients with peripheral arterial disease (PAD) and (2) to investigate the impact of this supplementation on coagulation and inflammation parameters.
Resumo:
Several clinical studies have compared single with tandem (also called double) autologous stem cell transplantation (ASCT) as first-line treatment in patients with symptomatic multiple myeloma (MM), one of the leading indications for ASCT worldwide.
Resumo:
A new generation of high definition computed tomography (HDCT) 64-slice devices complemented by a new iterative image reconstruction algorithm-adaptive statistical iterative reconstruction, offer substantially higher resolution compared to standard definition CT (SDCT) scanners. As high resolution confers higher noise we have compared image quality and radiation dose of coronary computed tomography angiography (CCTA) from HDCT versus SDCT. Consecutive patients (n = 93) underwent HDCT, and were compared to 93 patients who had previously undergone CCTA with SDCT matched for heart rate (HR), HR variability and body mass index (BMI). Tube voltage and current were adapted to the patient's BMI, using identical protocols in both groups. The image quality of all CCTA scans was evaluated by two independent readers in all coronary segments using a 4-point scale (1, excellent image quality; 2, blurring of the vessel wall; 3, image with artefacts but evaluative; 4, non-evaluative). Effective radiation dose was calculated from DLP multiplied by a conversion factor (0.014 mSv/mGy × cm). The mean image quality score from HDCT versus SDCT was comparable (2.02 ± 0.68 vs. 2.00 ± 0.76). Mean effective radiation dose did not significantly differ between HDCT (1.7 ± 0.6 mSv, range 1.0-3.7 mSv) and SDCT (1.9 ± 0.8 mSv, range 0.8-5.5 mSv; P = n.s.). HDCT scanners allow low-dose 64-slice CCTA scanning with higher resolution than SDCT but maintained image quality and equally low radiation dose. Whether this will translate into higher accuracy of HDCT for CAD detection remains to be evaluated.
Resumo:
This phase I trial was designed to develop a new effective and well-tolerated regimen for patients with aggressive B cell lymphoma not eligible for front-line anthracycline-based chemotherapy or aggressive second-line treatment strategies. The combination of rituximab (375 mg/m(2) on day 1), bendamustine (70 mg/m(2) on days 1 and 2), and lenalidomide was tested with a dose escalation of lenalidomide at three dose levels (10, 15, or 20 mg/day) using a 3 + 3 design. Courses were repeated every 4 weeks. The recommended dose was defined as one level below the dose level identifying ≥2/6 patients with a dose-limiting toxicity (DLT) during the first cycle. Thirteen patients were eligible for analysis. Median age was 77 years. WHO performance status was 0 or 1 in 12 patients. The Charlson Comorbidity Index showed relevant comorbidities in all patients. Two DLTs occurred at the second dose level (15 mg/day) within the first cycle: one patient had prolonged grade 3 neutropenia, and one patient experienced grade 4 cardiac adverse event (myocardial infarction). Additional grade 3 and 4 toxicities were as follows: neutropenia (31 %), thrombocytopenia (23 %), cardiac toxicity (31 %), fatigue (15 %), and rash (15 %). The dose of lenalidomide of 10 mg/day was recommended for a subsequent phase II in combination with rituximab 375 mg/m(2) on day 1 and bendamustine 70 mg/m(2) on days 1 and 2.
Resumo:
The electron Monte Carlo (eMC) dose calculation algorithm available in the Eclipse treatment planning system (Varian Medical Systems) is based on the macro MC method and uses a beam model applicable to Varian linear accelerators. This leads to limitations in accuracy if eMC is applied to non-Varian machines. In this work eMC is generalized to also allow accurate dose calculations for electron beams from Elekta and Siemens accelerators. First, changes made in the previous study to use eMC for low electron beam energies of Varian accelerators are applied. Then, a generalized beam model is developed using a main electron source and a main photon source representing electrons and photons from the scattering foil, respectively, an edge source of electrons, a transmission source of photons and a line source of electrons and photons representing the particles from the scrapers or inserts and head scatter radiation. Regarding the macro MC dose calculation algorithm, the transport code of the secondary particles is improved. The macro MC dose calculations are validated with corresponding dose calculations using EGSnrc in homogeneous and inhomogeneous phantoms. The validation of the generalized eMC is carried out by comparing calculated and measured dose distributions in water for Varian, Elekta and Siemens machines for a variety of beam energies, applicator sizes and SSDs. The comparisons are performed in units of cGy per MU. Overall, a general agreement between calculated and measured dose distributions for all machine types and all combinations of parameters investigated is found to be within 2% or 2 mm. The results of the dose comparisons suggest that the generalized eMC is now suitable to calculate dose distributions for Varian, Elekta and Siemens linear accelerators with sufficient accuracy in the range of the investigated combinations of beam energies, applicator sizes and SSDs.
Resumo:
Although the Monte Carlo (MC) method allows accurate dose calculation for proton radiotherapy, its usage is limited due to long computing time. In order to gain efficiency, a new macro MC (MMC) technique for proton dose calculations has been developed. The basic principle of the MMC transport is a local to global MC approach. The local simulations using GEANT4 consist of mono-energetic proton pencil beams impinging perpendicularly on slabs of different thicknesses and different materials (water, air, lung, adipose, muscle, spongiosa, cortical bone). During the local simulation multiple scattering, ionization as well as elastic and inelastic interactions have been taken into account and the physical characteristics such as lateral displacement, direction distributions and energy loss have been scored for primary and secondary particles. The scored data from appropriate slabs is then used for the stepwise transport of the protons in the MMC simulation while calculating the energy loss along the path between entrance and exit position. Additionally, based on local simulations the radiation transport of neutrons and the generated ions are included into the MMC simulations for the dose calculations. In order to validate the MMC transport, calculated dose distributions using the MMC transport and GEANT4 have been compared for different mono-energetic proton pencil beams impinging on different phantoms including homogeneous and inhomogeneous situations as well as on a patient CT scan. The agreement of calculated integral depth dose curves is better than 1% or 1 mm for all pencil beams and phantoms considered. For the dose profiles the agreement is within 1% or 1 mm in all phantoms for all energies and depths. The comparison of the dose distribution calculated using either GEANT4 or MMC in the patient also shows an agreement of within 1% or 1 mm. The efficiency of MMC is up to 200 times higher than for GEANT4. The very good level of agreement in the dose comparisons demonstrate that the newly developed MMC transport results in very accurate and efficient dose calculations for proton beams.
Resumo:
Cannabinoids exert neuroprotective and symptomatic effects in amyotrophic lateral sclerosis (ALS). We assessed the pharmacokinetics (PK) and tolerability of delta-9-tetrahydrocannabinol (THC) in ALS patients.
Resumo:
To quantify the dose of pancuronium required to obtain moderate neuromuscular blockade as monitored by acceleromyography (NMB(mod) : train-of-four count of ≤2) as a part of a balanced anaesthetic protocol in pigs used in cardiovascular research.
Resumo:
To assess the ability of low-dose CT to detect and characterize the most common CT patterns of pulmonary disease.
Resumo:
To determine sirolimus steady-state pharmacokinetics, and to assess the relationship between time-normalized trough sirolimus concentration (C(min,TN)) and evidence of efficacy (rejection and death) and adverse reactions (stomatitis and pneumonia) in liver allograft patients.
Resumo:
To evaluate the antibiotic treatment regime in patients with indwelling JJ stents, the benefits and disadvantages of a peri-interventional antibiotic prophylaxis were compared with those of a continuous low-dose antibiotic treatment in a prospective randomised trial.
Resumo:
There is no consensus regarding optimal dosing of high dose methotrexate (HDMTX) in patients with primary CNS lymphoma. Our aim was to develop a convenient dosing algorithm to target AUC(MTX) in the range between 1000 and 1100 µmol l(-1) h.