888 resultados para Leon Tolstoi
Resumo:
The heparin-binding epidermal growth factor-like growth factor (HB-EGF) has been implicated in wound-healing processes of various tissues. However, it is not known whether HB-EGF may represent a factor implicated in overstimulated wound-healing processes of the retina during proliferative retinopathies. Therefore, we investigated whether human retinal pigment epithelial (RPE) cells, which are crucially involved in proliferative retinopathies, express and respond to HB-EGF. RPE cells express mRNAs for various members of the EGF-related growth factor family, among them for HB-EGF, as well as for the EGF receptors ErbB1, -2, -3, and -4. The gene expression of HB-EGF is stimulated in the presence of transforming and basic fibroblast growth factors and by oxidative stress and is suppressed during chemical hypoxia. Exogenous HB-EGF stimulates proliferation and migration of RPE cells and the gene and protein expression of the vascular endothelial growth factor (VEGF). HB-EGF activates at least three signal transduction pathways in RPE cells including the extracellular signal-regulated kinases (involved in the proliferation-stimulating action of HB-EGF), p38 (mediates the effects on chemotaxis and secretion of VEGF), and the phosphatidylinositol-3 kinase (necessary for the stimulation of chemotaxis). In epiretinal membranes of patients with proliferative retinopathies, HB-EGF immunoreactivity was partially colocalized with the RPE cell marker, cytokeratins; this observation suggests that RPE cell-derived HB-EGF may represent one factor that drives the uncontrolled wound-healing process of the retina. The stimulating effect on the secretion of VEGF may suggest that HB-EGF is also implicated in the pathological angiogenesis of the retina.
Resumo:
OBJECTIVES: The purpose of this research was to determine the relative safety and efficacy of multiple (> or =2) overlapping Cypher sirolimus-eluting stents (SES) (Johnson ; Johnson, New Brunswick, New Jersey). BACKGROUND: Overlapping coronary stents are common. The periprocedural and late clinical and angiographic consequences of overlapped coronary stents are not clearly defined, particularly for drug-eluting stents. METHODS: All patients enrolled into five clinical trials of the SES were analyzed. Three of these trials were prospective randomized comparisons of the SES to the bare-metal stent (BMS), and two were prospective non-randomized trials of SES-treated patients with historical controls. All clinical and angiographic outcomes in overlap-stent-treated patients were compared by stent type and with single-stent-treated patients for the same stent device. RESULTS: In all, 575 patients with stent overlap (337 SES, 238 BMS) and 1,162 patients with single stents (697 SES, 465 BMS) were analyzed. Stent overlap was associated with a greater late lumen loss in stent and more frequent angiographic restenosis regardless of stent type. Among overlap-stent-treated patients, the SES provided similar magnitude of restenosis benefit as observed for single-stent-treated patients. Overlapped SES was not associated with an increase in myocardial infarction. CONCLUSIONS: The strategy of SES overlap, when required, is both safe and efficacious in reducing restenosis with no increase in the incidence of myocardial infarction or major adverse cardiovascular events, when compared with a bare metal coronary stent prosthesis.
Resumo:
Various inference procedures for linear regression models with censored failure times have been studied extensively. Recent developments on efficient algorithms to implement these procedures enhance the practical usage of such models in survival analysis. In this article, we present robust inferences for certain covariate effects on the failure time in the presence of "nuisance" confounders under a semiparametric, partial linear regression setting. Specifically, the estimation procedures for the regression coefficients of interest are derived from a working linear model and are valid even when the function of the confounders in the model is not correctly specified. The new proposals are illustrated with two examples and their validity for cases with practical sample sizes is demonstrated via a simulation study.
Resumo:
Whether the two drug-eluting stents approved by the US Food and Drug Administration-a sirolimus-eluting stent and a paclitaxel-eluting stent-are associated with increased risks of death, myocardial infarction, or stent thrombosis compared with bare-metal stents is uncertain. Our aim was to compare the safety and effectiveness of these stents.
Resumo:
It is widely accepted that peripheral trauma such as soft tissue injuries can trigger dystonia, although little is known about the underlying mechanism. Because peripheral injury only rarely appears to elicit dystonia, a predisposing vulnerability in cortical motor areas might play a role. Using single and paired-pulse pulse transcranial magnetic stimulation, we evaluated motor cortex excitability of a hand muscle in a patient with peripherally induced foot dystonia, in her brother with craniocervical dystonia, and in her unaffected sister, and compared their results to those from a group of normal subjects. In the patient with peripherally induced dystonia, we found a paradoxical intracortical facilitation at short interstimulus intervals of 3 and 5 milliseconds, at which regular intracortical inhibition (ICI) occurred in healthy subjects. These findings suggest that the foot dystonia may have been precipitated as the result of a preexisting abnormality of motor cortex excitability. Furthermore, the abnormality of ICI in her brother and sister indicates that altered motor excitability may be a hereditary predisposition. The study demonstrates that the paired-pulse technique is a useful tool to assess individual vulnerability, which can be particularly relevant when the causal association between trauma and dystonia is less evident.
Resumo:
Objective To compare the effectiveness and safety of three types of stents (sirolimus eluting, paclitaxel eluting, and bare metal) in people with and without diabetes mellitus. Design Collaborative network meta-analysis. Data sources Electronic databases (Medline, Embase, the Cochrane Central Register of Controlled Trials), relevant websites, reference lists, conference abstracts, reviews, book chapters, and proceedings of advisory panels for the US Food and Drug Administration. Manufacturers and trialists provided additional data. Review methods Network meta-analysis with a mixed treatment comparison method to combine direct within trial comparisons between stents with indirect evidence from other trials while maintaining randomisation. Overall mortality was the primary safety end point, target lesion revascularisation the effectiveness end point. Results 35 trials in 3852 people with diabetes and 10 947 people without diabetes contributed to the analyses. Inconsistency of the network was substantial for overall mortality in people with diabetes and seemed to be related to the duration of dual antiplatelet therapy (P value for interaction 0.02). Restricting the analysis to trials with a duration of dual antiplatelet therapy of six months or more, inconsistency was reduced considerably and hazard ratios for overall mortality were near one for all comparisons in people with diabetes: sirolimus eluting stents compared with bare metal stents 0.88 (95% credibility interval 0.55 to 1.30), paclitaxel eluting stents compared with bare metal stents 0.91 (0.60 to 1.38), and sirolimus eluting stents compared with paclitaxel eluting stents 0.95 (0.63 to 1.43). In people without diabetes, hazard ratios were unaffected by the restriction. Both drug eluting stents were associated with a decrease in revascularisation rates compared with bare metal stents in people both with and without diabetes. Conclusion In trials that specified a duration of dual antiplatelet therapy of six months or more after stent implantation, drug eluting stents seemed safe and effective in people both with and without diabetes.
Resumo:
Research in autophagy continues to accelerate,(1) and as a result many new scientists are entering the field. Accordingly, it is important to establish a standard set of criteria for monitoring macroautophagy in different organisms. Recent reviews have described the range of assays that have been used for this purpose.(2,3) There are many useful and convenient methods that can be used to monitor macroautophagy in yeast, but relatively few in other model systems, and there is much confusion regarding acceptable methods to measure macroautophagy in higher eukaryotes. A key point that needs to be emphasized is that there is a difference between measurements that monitor the numbers of autophagosomes versus those that measure flux through the autophagy pathway; thus, a block in macroautophagy that results in autophagosome accumulation needs to be differentiated from fully functional autophagy that includes delivery to, and degradation within, lysosomes (in most higher eukaryotes) or the vacuole (in plants and fungi). Here, we present a set of guidelines for the selection and interpretation of the methods that can be used by investigators who are attempting to examine macroautophagy and related processes, as well as by reviewers who need to provide realistic and reasonable critiques of papers that investigate these processes. This set of guidelines is not meant to be a formulaic set of rules, because the appropriate assays depend in part on the question being asked and the system being used. In addition, we emphasize that no individual assay is guaranteed to be the most appropriate one in every situation, and we strongly recommend the use of multiple assays to verify an autophagic response.
Resumo:
In der Unterkirche San Rocco in Sansepolcro erhebt sich eine Kleinarchitektur, die laut Inschrift als Kopie des Jerusalemer Christusgrabes ausgewiesen ist. Statt sich an die architektonische Gestalt des nahöstlichen Originals anzulehnen orientiert sie sich jedoch an einer älteren Heiliggrabkopie, dem Heiliggrabtempietto von Leon Battista Alberti in San Pancrazio, Florenz. Der Aufsatz untersucht, auf welche Weise die „doppelte Kopie“ ihr Vorbild interpretiert und stellt Überlegungen zu Motivation, Bedeutung und Autorschaft der Heiliggrabkopie von Sansepolcro an.