985 resultados para Landsat Satellite Images
Resumo:
This paper explores the extent and limits of non-state authority in international affairs. While a number of studies have emphasised the role of state support and the ability of strategically situated actors to capture regulatory processes, they often fail to unpack the conditions under which this takes place. In order to probe the assumption that structural market power, backed by political support, equates regulatory capture, the article examines the interplay of political and economic considerations in the negotiations to establish worldwide interoperability standards needed for the development of Galileo as a genuinely European global navigation satellite system under civil control. It argues that industries supported and identified as strategic by public actors are more likely to capture standardisation processes than those with the largest market share expected to be created by the standards. This suggests that the influence of industries in space, air and maritime traffic control closely related to the militaro-industrial complex remains disproportionate in comparison to the prospective market of location-based services expected to vastly transform business practices, labour relations and many aspects of our daily life.
Les images dans la construction et la communication du savoir scientifique: note pour une généalogie
Resumo:
To compare autofluorescence (AF) images obtained with the confocal scanning laser ophthalmoscope (using the Heidelberg retina angiograph; HRA) and the modified Topcon fundus camera, in a routine clinical setting. A prospective comparative study conducted at the Jules-Gonin Eye Hospital. Fifty-six patients from the medical retina clinic. All patients had complete ophthalmic slit-lamp and fundus examinations, colour and red-free fundus photography, AF imaging with both instruments, and fluorescein angiography. Cataract and fixation were graded clinically. AF patterns were analyzed for healthy and pathological features. Differences of image noise were analyzed by cataract grading and fixation. A total of 105 eyes were included. AF patterns discovered by the retina angiograph and the fundus camera images, respectively, were a dark optic disc in 72 % versus 15 %, a dark fovea in 92 % versus 4 %, sub- and intraretinal fluid visible as hyperautofluorescence on HRA images only, lipid exudates visible as hypoautofluorescence on HRA images only. The same autofluorescent pattern was found on both images for geographic atrophy, retinal pigment changes, drusen and haemorrhage. Image noise was significantly associated with the degree of cataract and/or poor fixation, favouring the fundus camera. Images acquired by the fundus camera before and after fluorescein angiography were identical. Fundus AF images differ according to the technical differences of the instruments used. Knowledge of these differences is important not only for correctly interpreting images, but also for selecting the most appropriate instrument for the clinical situation.
Resumo:
BACKGROUND AND PURPOSE: The posterior circulation Acute Stroke Prognosis Early CT Score (pc-ASPECTS) quantifies the extent of early ischemic changes in the posterior circulation with a 10-point grading system. We hypothesized that pc-ASPECTS applied to CT angiography source images predicts functional outcome of patients in the Basilar Artery International Cooperation Study (BASICS). METHODS: BASICS was a prospective, observational registry of consecutive patients with acute symptomatic basilar artery occlusion. Functional outcome was assessed at 1 month. We applied pc-ASPECTS to CT angiography source images of patients with CT angiography for confirmation of basilar artery occlusion. We calculated unadjusted and adjusted risk ratios (RRs) of pc-ASPECTS dichotomized at ≥8 versus <8. Primary outcome measure was favorable outcome (modified Rankin Scale scores 0-3). Secondary outcome measures were mortality and functional independence (modified Rankin Scale scores 0-2). RESULTS: Of 158 patients included, 78 patients had a CT angiography source images pc-ASPECTS≥8. Patients with a pc-ASPECTS≥8 more often had a favorable outcome than patients with a pc-ASPECTS<8 (crude RR, 1.7; 95% CI, 0.98-3.0). After adjustment for age, baseline National Institutes of Health Stroke Scale score, and thrombolysis, pc-ASPECTS≥8 was not related to favorable outcome (RR, 1.3; 95% CI, 0.8-2.2), but it was related to reduced mortality (RR, 0.7; 95% CI, 0.5-0.98) and functional independence (RR, 2.0; 95% CI, 1.1-3.8). In post hoc analysis, pc-ASPECTS dichotomized at ≥6 versus <6 predicted a favorable outcome (adjusted RR, 3.1; 95% CI, 1.2-7.5). CONCLUSIONS: pc-ASPECTS on CT angiography source images independently predicted death and functional independence at 1 month in the CT angiography subgroup of patients in the BASICS registry.
Resumo:
Une double démarche est proposée pour appréhender comment des enfants en âge préscolaire élaborent leur compréhension du récit d'un album sans texte, à l'aide d'un adulte dans le contexte d'une Institution de la Petite Enfance (IPE). Si la première analyse porte sur la construction de la compétence narrative et met l'accent sur la nécessité d'un ajustement entre partenaires de l'interaction pour y parvenir, la deuxième se concentre sur les moments de désajustement et leur dépassement, constitutifs eux-aussi de l'apprentissage d'un savoir et de celui de la compétence communicative. Des extraits d'interactions d'une séance de lecture d'images sont analysés pour illustrer ces deux démarches.