961 resultados para LINKAGE DISEQUILIBRIUM


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction The consistency of measuring small field output factors is greatly increased by reporting the measured dosimetric field size of each factor, as opposed to simply stating the nominal field size [1] and therefore requires the measurement of cross-axis profiles in a water tank. However, this makes output factor measurements time consuming. This project establishes at which field size the accuracy of output factors are not affected by the use of potentially inaccurate nominal field sizes, which we believe establishes a practical working definition of a ‘small’ field. The physical components of the radiation beam that contribute to the rapid change in output factor at small field sizes are examined in detail. The physical interaction that dominates the cause of the rapid dose reduction is quantified, and leads to the establishment of a theoretical definition of a ‘small’ field. Methods Current recommendations suggest that radiation collimation systems and isocentre defining lasers should both be calibrated to permit a maximum positioning uncertainty of 1 mm [2]. The proposed practical definition for small field sizes is as follows: if the output factor changes by ±1.0 % given a change in either field size or detector position of up to ±1 mm then the field should be considered small. Monte Carlo modelling was used to simulate output factors of a 6 MV photon beam for square fields with side lengths from 4.0 to 20.0 mm in 1.0 mm increments. The dose was scored to a 0.5 mm wide and 2.0 mm deep cylindrical volume of water within a cubic water phantom, at a depth of 5 cm and SSD of 95 cm. The maximum difference due to a collimator error of ±1 mm was found by comparing the output factors of adjacent field sizes. The output factor simulations were repeated 1 mm off-axis to quantify the effect of detector misalignment. Further simulations separated the total output factor into collimator scatter factor and phantom scatter factor. The collimator scatter factor was further separated into primary source occlusion effects and ‘traditional’ effects (a combination of flattening filter and jaw scatter etc.). The phantom scatter was separated in photon scatter and electronic disequilibrium. Each of these factors was plotted as a function of field size in order to quantify how each affected the change in small field size. Results The use of our practical definition resulted in field sizes of 15 mm or less being characterised as ‘small’. The change in field size had a greater effect than that of detector misalignment. For field sizes of 12 mm or less, electronic disequilibrium was found to cause the largest change in dose to the central axis (d = 5 cm). Source occlusion also caused a large change in output factor for field sizes less than 8 mm. Discussion and conclusions The measurement of cross-axis profiles are only required for output factor measurements for field sizes of 15 mm or less (for a 6 MV beam on Varian iX linear accelerator). This is expected to be dependent on linear accelerator spot size and photon energy. While some electronic disequilibrium was shown to occur at field sizes as large as 30 mm (the ‘traditional’ definition of small field [3]), it has been shown that it does not cause a greater change than photon scatter until a field size of 12 mm, at which point it becomes by far the most dominant effect.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction Total scatter factor (or output factor) in megavoltage photon dosimetry is a measure of relative dose relating a certain field size to a reference field size. The use of solid phantoms has been well established for output factor measurements, however to date these phantoms have not been tested with small fields. In this work, we evaluate the water equivalency of a number of solid phantoms for small field output factor measurements using the EGSnrc Monte Carlo code. Methods The following small square field sizes were simulated using BEAMnrc: 5, 6, 7, 8, 10 and 30 mm. Each simulated phantom geometry was created in DOSXYZnrc and consisted of a silicon diode (of length and width 1.5 mm and depth 0.5 mm) submersed in the phantom at a depth of 5 g/cm2. The source-to-detector distance was 100 cm for all simulations. The dose was scored in a single voxel at the location of the diode. Interaction probabilities and radiation transport parameters for each material were created using custom PEGS4 files. Results A comparison of the resultant output factors in the solid phantoms, compared to the same factors in a water phantom are shown in Fig. 1. The statistical uncertainty in each point was less than or equal to 0.4 %. The results in Fig. 1 show that the density of the phantoms affected the output factor results, with higher density materials (such as PMMA) resulting in higher output factors. Additionally, it was also calculated that scaling the depth for equivalent path length had negligible effect on the output factor results at these field sizes. Discussion and conclusions Electron stopping power and photon mass energy absorption change minimally with small field size [1]. Also, it can be seen from Fig. 1 that the difference from water decreases with increasing field size. Therefore, the most likely cause for the observed discrepancies in output factors is differing electron disequilibrium as a function of phantom density. When measuring small field output factors in a solid phantom, it is important that the density is very close to that of water.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction This study investigated the sensitivity of calculated stereotactic radiotherapy and radiosurgery doses to the accuracy of the beam data used by the treatment planning system. Methods Two sets of field output factors were acquired using fields smaller than approximately 1 cm2, for inclusion in beam data used by the iPlan treatment planning system (Brainlab, Feldkirchen, Germany). One set of output factors were measured using an Exradin A16 ion chamber (Standard Imaging, Middleton, USA). Although this chamber has a relatively small collecting volume (0.007 cm3), measurements made in small fields using this chamber are subject to the effects of volume averaging, electronic disequilibrium and chamber perturbations. The second, more accurate, set of measurements were obtained by applying perturbation correction factors, calculated using Monte Carlo simulations according to a method recommended by Cranmer-Sargison et al. [1] to measurements made using a 60017 unshielded electron diode (PTW, Freiburg, Germany). A series of 12 sample patient treatments were used to investigate the effects of beam data accuracy on resulting planned dose. These treatments, which involved 135 fields, were planned for delivery via static conformal arcs and 3DCRT techniques, to targets ranging from prostates (up to 8 cm across) to meningiomas (usually more than 2 cm across) to arterioveinous malformations, acoustic neuromas and brain metastases (often less than 2 cm across). Isocentre doses were calculated for all of these fields using iPlan, and the results of using the two different sets of beam data were evaluated. Results While the isocentre doses for many fields are identical (difference = 0.0 %), there is a general trend for the doses calculated using the data obtained from corrected diode measurements to exceed the doses calculated using the less-accurate Exradin ion chamber measurements (difference\0.0 %). There are several alarming outliers (circled in the Fig. 1) where doses differ by more than 3 %, in beams from sample treatments planned for volumes up to 2 cm across. Discussion and conclusions These results demonstrate that treatment planning dose calculations for SRT/SRS treatments can be substantially affected when beam data for fields smaller than approximately 1 cm2 are measured inaccurately, even when treatment volumes are up to 2 cm across.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A trypsin inhibitor locus (Tri) has been mapped close to Vc-2 on Pisum (pea) linkage group 5 using recombinant inbred lines derived from crosses of genotypes showing qualitative variation in seed trypsin inhibitors. F2 seed populations derived from crosses between lines showing qualitative variation in trypsin inhibitors as well as quantitative variation in inhibitor activity showed an association between the segregation of the structural variation and relative activity levels. Clones complementary to Pisum trypsin inhibitor mRNA were used in hybridization analyses which showed that the segregation of protein polymorphisms reflected directly the segregation of polymorphisms associated with the structural genes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The woodland strawberry, Fragaria vesca (2n = 2x = 14), is a versatile experimental plant system. This diminutive herbaceous perennial has a small genome (240 Mb), is amenable to genetic transformation and shares substantial sequence identity with the cultivated strawberry (Fragaria Ã- ananassa) and other economically important rosaceous plants. Here we report the draft F. vesca genome, which was sequenced to ×-39 coverage using second-generation technology, assembled de novo and then anchored to the genetic linkage map into seven pseudochromosomes. This diploid strawberry sequence lacks the large genome duplications seen in other rosids. Gene prediction modeling identified 34,809 genes, with most being supported by transcriptome mapping. Genes critical to valuable horticultural traits including flavor, nutritional value and flowering time were identified. Macrosyntenic relationships between Fragaria and Prunus predict a hypothetical ancestral Rosaceae genome that had nine chromosomes. New phylogenetic analysis of 154 protein-coding genes suggests that assignment of Populus to Malvidae, rather than Fabidae, is warranted.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Restriction fragment length polymorphisms have been used to determine the chromosomal location of the genes encoding the glycine decarboxylase complex (GDC) and serine hydroxymethyltransferase (SHMT) of pea leaf mitochondria. The genes encoding the H subunit of GDC and the genes encoding SHMT both show linkage to the classical group I marker i. In addition, the genes for the P protein of GDC show linkage to the classic group I marker a. The genes for the L and T proteins of GDC are linked to one another and are probably situated on the satellite of chromosome 7. The mRNAs encoding the five polypeptides that make up GDC and SHMT are strongly induced when dark-grown etiolated pea seedlings are placed in the light. Similarly, when mature plants are placed in the dark for 48 h, the levels of both GDC protein and SHMT mRNAs decline dramatically and then are induced strongly when these plants are returned to the light. During both treatments a similar pattern of mRNA induction is observed, with the mRNA encoding the P protein of GDC being the most rapidly induced and the mRNA for the H protein the slowest. Whereas during the greening of etiolated seedlings the polypeptides of GDC and SHMT show patterns of accumulation similar to those of the corresponding mRNAs, very little change in the level of the polypeptides is seen when mature plants are placed in the dark and then re-exposed to the light.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Lipoprotein(a) (Lp(a)) is bound to apolipoprotein B-100 by disulfide linkage and is associated in the upper density range of low density lipoprotein cholesterol. Persons with elevated concentrations of Lp(a) are regarded as having an increased risk for premature coronary artery disease. Although many studies exist evaluating the effects of a single session of exercise on lipids and lipoproteins, little information is available concerning the effects of exercise on Lp(a). Therefore, the purpose of this study was to determine the effects of a single exercise session on plasma Lp(a). Twelve physically active men completed two 30-min submaximal treadmill exercise sessions: low intensity (LI, 50% VO2max) and high intensity (HI, 80% VO2max). Blood samples were obtained immediately before and after exercise. Total cholesterol (LI: before 4.22 +/- 0.26, after 4.24 +/- 0.28; HI: before 4.24 +/- 0.31, after 4.11 +/- 0.28 mmol . l(-1), mean +/- SE) and triglyceride (LI: before 1.14 +/- 0.16, after 1.06 +/- 0.16; HI: before 1.12 +/- 0.19, after 1.21 +/- 0.19 mmol . l(-1)) concentrations did not differ immediately after either exercise session, nor did Lp(a) concentrations differ immediately after either exercise session (LI: before 4.1 +/- 2.2, after 4.0 +/- 2.1; HI: before 3.9 +/- 2.2, after 3.7 +/- 2.0 mg . dl(-1)). These results suggest that neither a low nor a high intensity exercise session lasting 30 min in duration has an immediate effect on plasma Lp(a).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This research was a step forward to developing data sets for thin layer mortared concrete masonry through systematic experimental and numerical studies. Since thin layer mortared concrete masonry is relatively new type of masonry construction, methodical research studies have been undertaken to properly address the gaps in understanding of this masonry system. As part of the ARC Linkage research project, this thesis has been developed to extend the knowledge on thin layer mortared concrete masonry.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This research first asks ‘What happens when young people leave state care?’ in respect of Victoria and Queensland and second ‘What are the service support implications of this?’ A number of methods were used to explore these questions including semi-structured interviews with 27 young adults aged 19-23 years who had been homeless or at risk of homelessness, and focus groups with young people and service providers. This study provides support for the proposition that young people should be proactively and voluntarily involved in periodic monitoring of their lived experience post care and linkage of this monitoring to the activation of timely support. The great majority of young people involved in this study thought this was not only desirable but important. Whilst some young people will be in close contact with leaving care services many others will not. New research is recommended to develop a mentoring and support activation process using participatory monitoring and action research methods. This type of approach reflects the importance of utilising processes with young people in care and leaving care which acknowledge their personhood and capacity to contribute voluntarily to the processes which seek to support them.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study investigates the price linkage among the US major energy sources, considering structural breaks in time series, to provide information for diversifying the US energy sources. We find that only a weak linkage sustains among crude oil, gasoline, heating oil, coal, natural gas, uranium and ethanol futures prices. This implies that the US major energy source markets are not integrated as one primary energy market. Our tests also reveal that uranium and ethanol futures prices have very weak linkages with other major energy source prices. This indicates that the US energy market is still at a stage where none of the probable alternative energy source markets are playing the role as substitute or complement markets for the fossil fuel energy markets.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study investigates how markets for different levels of copper purity are interrelated by testing the long-run price linkage and causalities among the copper futures, primary, copper scrap, and brass scrap markets. It is expected that copper markets that deal with high purity levels, such as the futures, primary, and copper scrap markets, have a long-run relationship. However, brass scrap markets where copper with a lower purity is traded may not have a price linkage with other copper markets. The results reveal that a long-run relationship holds between the futures, primary, and copper scrap markets but the brass scrap market does not have a long-run relationship with the other markets. From the short-run and long-run causality tests, we determine that the futures market plays an important role in transmitting price information to other copper markets while such information flow is not found for the brass scrap market.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Building healthcare resilience is an important step towards creating more resilient communities to better cope with future disasters. To date, however, there appears to be little literature on how the concept of healthcare resilience should be defined and operationalized with a conceptual framework. This article aims to build a comprehensive healthcare disaster management approach guided by the concept of resilience. Methods: Google and major health electronic databases were searched to retrieve critical relevant publications. A total of 61 related publications were included, to provide a comprehensive overview of theories and definitions relevant to disaster resilience. Results and Discussions: Resilience is an inherent and adaptive capacity to cope with future uncertainty, through multiple strategies with all hazards approaches, in an attempt to achieve a positive outcome with linkage and cooperation. Healthcare resilience can be defined as the capability of healthcare organisations to resist, absorb, and respond to the shock of disasters while maintaining the most essential functions, then recover to their original state or adapt to a new state. It can be assessed by criteria, namely: robustness, redundancy, resourcefulness; and a complex of key dimensions, namely: vulnerability and safety, disaster resources and preparedness, continuity of essential health services, recovery and adaptation. Conclusions: This new concept places healthcare organisations’ disaster capabilities, management tasks, activities and disaster outcomes together into a comprehensive whole view, using an integrated approach and establishing achievable goals.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim A new method of penumbral analysis is implemented which allows an unambiguous determination of field size and penumbra size and quality for small fields and other non-standard fields. Both source occlusion and lateral electronic disequilibrium will affect the size and shape of cross-axis profile penumbrae; each is examined in detail. Method A new method of penumbral analysis is implemented where the square of the derivative of the cross-axis profile is plotted. The resultant graph displays two peaks in the place of the two penumbrae. This allows a strong visualisation of the quality of a field penumbra, as well as a mathematically consistent method of determining field size (distance between the two peak’s maxima), and penumbra (full-widthtenth-maximum of peak). Cross-axis profiles were simulated in a water phantom at a depth of 5 cm using Monte Carlo modelling, for field sizes between 5 and 30 mm. The field size and penumbra size of each field was calculated using the method above, as well as traditional definitions set out in IEC976. The effect of source occlusion and lateral electronic disequilibrium on the penumbrae was isolated by repeating the simulations removing electron transport and using an electron spot size of 0 mm, respectively. Results All field sizes calculated using the traditional and proposed methods agreed within 0.2 mm. The penumbra size measured using the proposed method was systematically 1.8 mm larger than the traditional method at all field sizes. The size of the source had a larger effect on the size of the penumbra than did lateral electronic disequilibrium, particularly at very small field sizes. Conclusion Traditional methods of calculating field size and penumbra are proved to be mathematically adequate for small fields. However, the field size definition proposed in this study would be more robust amongst other nonstandard fields, such as flattening filter free. Source occlusion plays a bigger role than lateral electronic disequilibrium in small field penumbra size.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper we propose a novel scheme for carrying out speaker diarization in an iterative manner. We aim to show that the information obtained through the first pass of speaker diarization can be reused to refine and improve the original diarization results. We call this technique speaker rediarization and demonstrate the practical application of our rediarization algorithm using a large archive of two-speaker telephone conversation recordings. We use the NIST 2008 SRE summed telephone corpora for evaluating our speaker rediarization system. This corpus contains recurring speaker identities across independent recording sessions that need to be linked across the entire corpus. We show that our speaker rediarization scheme can take advantage of inter-session speaker information, linked in the initial diarization pass, to achieve a 30% relative improvement over the original diarization error rate (DER) after only two iterations of rediarization.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Our presentation today will introduce our current ARC Linkage project on Australian screen content in education. We will then go on to discuss our initial research, which is attempting to quantify the use of screen content in Australian education. The presentation concludes with a brief discussion of some of the emerging video on demand services available to schools and universities.