947 resultados para Intermittent microwave


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Institute of Applied Physics observes middle atmospheric trace gases, such as ozone and water vapour, by microwave radiometry. We report on the comparison of measurements using a novel digital Fast Fourier Transform and accousto optical spectrometers. First tests made on ground are presented as well as first experience about the use of such spectrometers under aircraft conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite changes in patient demographics and short-ened length of hospital stay deep vein thrombosis (DVT) remains a major health care problem which may lead to a variety of other high risk complications. Current treatment guidelines focus on preventive measures. Beside drug therapy, physical measures executed by nursing professionals exist, the outcomes of which are discussed controversially. Based on 25 studies that were found in MEDLINE and the Cochrane library, this systematic literature review identifies the effectiveness of intermittent pneumatic compression (IPC) on thrombosis prophylaxis. In almost all medical settings IPC contributes to a significant reduction of the incidence of DVT. At the same time, IPC has minimal negative side effects and is also cost effective. Correct application of IPC and patient compliance are essential to achieve its effectiveness. An increased awareness within the healthcare team in identifying the risk for and implementing measures against DVT is needed. Guidelines need to be developed in order to improve the effectiveness of thrombosis prophylaxis with the implementation of IPC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To investigate whether intermittent pneumatic compression (IPC) augments skin blood flow through transient suspension of local vasoregulation, the veno-arteriolar response (VAR), in healthy controls and in patients with peripheral arterial disease (PAD). METHODS: Nineteen healthy limbs and twenty-two limbs with PAD were examined. To assess VAR, skin blood flow (SBF) was measured using laser Doppler fluxmetry in the horizontal and sitting positions and was defined as percentage change with postural alteration [(horizontal SBF--sitting SBF)/horizontal SBF x 100]. On IPC application to the foot, the calf, or both, SBF was measured with laser Doppler fluxmetry, the probe being attached to the pulp of the big toe. RESULTS: Baseline VAR was higher in the controls 63.8 +/- 6.4% than in patients with PAD (31.7 +/- 13.4%, P = .0162). In both groups SBF was significantly higher with IPC than at rest (P < .0001). A higher percentage increase with IPC was demonstrated in the controls (242 +/- 85% to 788 +/- 318%) than in subjects with PAD, for each one of the three different IPC modes investigated (98 +/- 33% to 275 +/- 72%) with IPC was demonstrated. The SBF enhancement with IPC correlated with VAR for all three compression modes (r = 0.58, P = .002 for calf compression, r = 0.65, P < .0001 for foot compression alone, and r = 0.64, P = .0002 for combined foot and calf compression). CONCLUSION: The integrity of the veno-arteriolar response correlates with the level of skin blood flow augmentation generated with intermittent pneumatic compression, indicating that this may be associated with a transient suspension of the autoregulatory vasoconstriction both in healthy controls and in patients with PAD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Supervised exercise training has been shown to improve walking capacity in several studies of patients with intermittent claudication. However, data on long-term outcome are quite limited. The aim of this prospective study was to evaluate long-term effects of supervised exercise training on walking capacity and quality of life in patients with intermittent claudication. Patients and methods: Sixty-seven consecutive patients with intermittent claudication who completed a supervised 12-week exercise training program were asked for follow up evaluation 39 +/- 20 months after program completion. Pain-free walking distance (PWD) and maximum walking distances (MWD) were assessed by treadmill test and several questionnaires. Results: Forty (60%) patients agreed to participate, 22 (33%) refused participation, and 5 (7%) died during follow-up. PWD and MWD significantly improved at completion of 12-weeks supervised exercise training as compared to baseline (PWD 114 +/- 100 vs. 235 +/- 248, p = 0.002; MWD 297 +/- 273 vs. 474 +/- 359, p = 0.001). Improvement of PWD and MWD could be maintained at follow up (197 +/- 254, p = 0.014; 390 +/- 324, p = 0.035, respectively) with non-smokers showing significantly better sustained PWD and MWD improvement as compared to baseline. Overall, walking capacity correlated with functional status of quality of life. Conclusions: Major findings of this investigation were that improvement in walking capacity is sustained after completion of supervised exercise training program with best results in patients who quitted or never smoked. Improved walking capacity is associated with increased functional status of quality of life.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Heat transfer is considered as one of the most critical issues for design and implement of large-scale microwave heating systems, in which improvement of the microwave absorption of materials and suppression of uneven temperature distribution are the two main objectives. The present work focuses on the analysis of heat transfer in microwave heating for achieving highly efficient microwave assisted steelmaking through the investigations on the following aspects: (1) characterization of microwave dissipation using the derived equations, (2) quantification of magnetic loss, (3) determination of microwave absorption properties of materials, (4) modeling of microwave propagation, (5) simulation of heat transfer, and (6) improvement of microwave absorption and heating uniformity. Microwave heating is attributed to the heat generation in materials, which depends on the microwave dissipation. To theoretically characterize microwave heating, simplified equations for determining the transverse electromagnetic mode (TEM) power penetration depth, microwave field attenuation length, and half-power depth of microwaves in materials having both magnetic and dielectric responses were derived. It was followed by developing a simplified equation for quantifying magnetic loss in materials under microwave irradiation to demonstrate the importance of magnetic loss in microwave heating. The permittivity and permeability measurements of various materials, namely, hematite, magnetite concentrate, wüstite, and coal were performed. Microwave loss calculations for these materials were carried out. It is suggested that magnetic loss can play a major role in the heating of magnetic dielectrics. Microwave propagation in various media was predicted using the finite-difference time-domain method. For lossy magnetic dielectrics, the dissipation of microwaves in the medium is ascribed to the decay of both electric and magnetic fields. The heat transfer process in microwave heating of magnetite, which is a typical magnetic dielectric, was simulated by using an explicit finite-difference approach. It is demonstrated that the heat generation due to microwave irradiation dominates the initial temperature rise in the heating and the heat radiation heavily affects the temperature distribution, giving rise to a hot spot in the predicted temperature profile. Microwave heating at 915 MHz exhibits better heating homogeneity than that at 2450 MHz due to larger microwave penetration depth. To minimize/avoid temperature nonuniformity during microwave heating the optimization of object dimension should be considered. The calculated reflection loss over the temperature range of heating is found to be useful for obtaining a rapid optimization of absorber dimension, which increases microwave absorption and achieves relatively uniform heating. To further improve the heating effectiveness, a function for evaluating absorber impedance matching in microwave heating was proposed. It is found that the maximum absorption is associated with perfect impedance matching, which can be achieved by either selecting a reasonable sample dimension or modifying the microwave parameters of the sample.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

LiFePO4 is a Co-free battery material. Its advantages of low cost, non-toxic and flat discharge plateau show promising for vehicle propulsion applications. A major problem associated with this material is its low electrical conductivity. Use of nanosized LiFePO4 coated with carbon is considered a solution because the nanosized particles have much shorter path for L+ ions to travel from the LiFePO4 crystal lattice to electrolytes. As other nano material powders, however, nano LiFePO4 could have processing and health issues. In order to achieve high electrical conductivity while maintaining a satisfactory manufacturability, the particles should possess both of the nano- and the microcharacteristics correspondingly. These two contradictory requirements could only be fulfilled if the LiFePO4 powders have a hierarchical structure: micron-sized parent particles assembled by nanosized crystallites with appropriate electrolyte communication channels. This study addressed the issue by study of the formation and development mechanisms of the LiFePO4 crystallites and their microstructures. Microwaveassisted wet chemical (MAWC) synthesis approach was employed in order to facilitate the evolvement of the nanostructures. The results reveal that the LiFePO4 crystallites were directly nucleated from amorphous precursors by competition against other low temperature phases, Li3PO4 and Fe3(PO4)2•8H2O. Growth of the crystalline LiFePO4 particles went through oriented attachment first, followed by revised Ostwald ripening and then recrystallization. While recrystallization played the role in growth of well crystallized particles, oriented attachment and revised Ostwald ripening were responsible for formation of the straight edge and plate-like shaped LiFePO4 particles comprised of nanoscale substructure. Oriented attachment and revised Ostwald ripening seemed to be also responsible for clustering the plate-like LiFePO4 particles into a high-level aggregated structure. The finding from this study indicates a hope for obtaining the hierarchical structure of LiFePO4 particles that could exhibit the both micro- and nano- scale characteristics. Future study is proposed to further advance the understanding of the structural development mechanisms, so that they can be manipulated for new LiFePO4 structures ideal for battery application.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: In male patients with ileal bladder substitute we ascertained the likelihood of spontaneous voiding failure, the corrective procedures required and the eventual outcomes. MATERIALS AND METHODS: Following cystectomy and ileal bladder substitution for urothelial cancer between April 1985 and September 2002 male patients were identified and analyzed from the prospective departmental database. Four patients underwent ileum conduit conversion following urethral recurrence or pouch necrosis and were excluded from study. Funnel-shaped outlets were avoided during bladder substitute surgery after the first 4 patients with this configuration experienced voiding failure and required corrective procedures. Only patients with a minimum 5-year followup were assessed for voiding failure, corrective procedures and final outcomes. RESULTS: Of 354 patients with a median age of 65 years (range 36 to 84) treated with bladder substitute 180 (51%) were alive at 5 years. All 180 of these patients spontaneously voided within 3 months of surgery. During this 5-year observation period 22 (12%) patients experienced voiding problems requiring de-obstructive procedures. Following intervention 177 (98%) patients were spontaneously voiding by 5 years. Of 237 patients 77 (32%) were alive at 10 years. Of these 77 patients followed for another 5 years 10 (13%) had similar voiding problems requiring de-obstructive procedures. Subsequently 74 (96%) were voiding spontaneously by 10 years. CONCLUSIONS: Patients often fail to void spontaneously after ileal bladder substitution. However, if a funnel-shaped outlet is avoided and de-obstructive surgery is appropriately implemented, excellent long-term results are seen with spontaneous voiding and clean intermittent catheterization can be avoided.