883 resultados para Interior lighting.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Spanish Ministry of Economy and Competitiveness is funding the SHERIF Research Project, which falls under the INNPACTO pr ogram. This project aims to increase the rate of the existing building refurbishment fro m the energy efficiency point of view by designing a facade system that must be an economica l, flexible and integrated solution 1 . Under this project has been performing several task s regarding the constructive characterization and energy evaluation of the therm al behaviour of facades on existing buildings . In order to perform the latter task, in which this article will focus, has been developing a survey of various buildings in the nei ghbourhood Ciudad de los Angeles, which has as main objective the comparison between the ac tual energy and light behaviour of different buildings, prior and posterior to any ref urbishment works have been undertaken. The evaluation of the actual performance of buildin gs before and after being refurbished is aimed to determine the impact of the work developed as well as learn from the work performed for future interventions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El objetivo del presente trabajo es realizar una evaluación realista de la incertidumbre en los ensayos de ruido transmitido al interior de una sala según el Anexo IV del Real Decreto 1367/2007, contemplando todas las posibles causas que intervienen en la incertidumbre de forma que las imprecisiones observadas en los ejercicios de intercomparación se cubran con un único ensayo. Otra parte fundamental del trabajo es cuantificar la fuente de incertidumbre generada en la elección del punto de medición. En primer lugar se realiza la medición del nivel continuo equivalente ponderado A en habitaciones de distinto tamaño, a la que llegan los distintos tipos de ruido emitido desde el exterior de las mismas. El siguiente paso es realizar un análisis de los niveles medidos, tanto en su distribución espacial como en su evolución temporal, incidiendo en los valores máximos, LAeq,5s. A continuación se comprueba si la distribución de los niveles medidos se ajusta a una distribución normal mediante el software de análisis estadístico STATGRAPHICS. Determinando, en base al tamaño de las muestras escogidas, por medio de análisis estadísticos, la aportación a la incertidumbre generada en la elección del punto de medida, cuantificando su valor. Por último se realiza una medición del ruido de actividades según el Real Decreto 1367/2007, aportando una evaluación de la incertidumbre, teniendo en cuenta todas las fuentes que la generan, mediante el enfoque clásico de la GUM. ABSTRACT. The objective of this work is to carry out a realistic assessment of the uncertainty in the trials of noise transmitted into the interior of a room according to Annex IV of the Royal Decree 136772997, considering all of the causes involved in uncertainty in such a way that the inaccuracies observed in intercomparison exercises are covered with a single trial. Another fundamental part of the work is to quantify the source of uncertainty in the choice of the point of measurement. First is the weighted equivalent of the continuous level measurement in rooms of different sizes, which reach different types of noise emitted from outside of them. The next step is to perform an analysis of the measured levels, both in their spatial distribution and their temporal evolution, influencing the maximum values, LAeq,5s. Then it is checked to see whether the distribution of the measured levels conforms to a normal distribution using the STATGRAPHICS statistical analysis software. Determining therefore, based on the size of the selected samples, through statistical analysis, the contribution to the uncertainty generated in the choice of the measurement point, quantifying its value. At last is the measure of the noise of activities according to the Royal Decree 1367/2007, providing an assessment of the uncertainty, taking into account all sources that generate it, using the classical approach to the GUM.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A full Hybrid lighting-CPV prototype has been assembled. This new concept mixes a classical CPV module with the production of light for illumination without a double conversion (solar energy to electricity and electricity to light) allowing a higher efficiency to the whole system. The present prototype is based on a commercial CPV module that has been adapted in order to be hybrid, adjusting the receivers to pass the fibers into the module, inserting a holder to adjust x,y and z position of the fibers and changing the original parquet of lenses by a bifocal one composed most of the original lenses and the inclusion of other lenses in the position of the corners. Results show that with a minimal loss in the CPV part, a luminous flux is obtained that can be used to illuminate. Adding an additional electrical lamp and a light sensor that enables this lamp when no light from the sun is received, a 38% saving on lighting electricity is expected in Madrid during a year.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hoy en día, el proceso de un proyecto sostenible persigue realizar edificios de elevadas prestaciones que son, energéticamente eficientes, saludables y económicamente viables utilizando sabiamente recursos renovables para minimizar el impacto sobre el medio ambiente reduciendo, en lo posible, la demanda de energía, lo que se ha convertido, en la última década, en una prioridad. La Directiva 2002/91/CE "Eficiencia Energética de los Edificios" (y actualizaciones posteriores) ha establecido el marco regulatorio general para el cálculo de los requerimientos energéticos mínimos. Desde esa fecha, el objetivo de cumplir con las nuevas directivas y protocolos ha conducido las políticas energéticas de los distintos países en la misma dirección, centrándose en la necesidad de aumentar la eficiencia energética en los edificios, la adopción de medidas para reducir el consumo, y el fomento de la generación de energía a través de fuentes renovables. Los edificios de energía nula o casi nula (ZEB, Zero Energy Buildings ó NZEB, Net Zero Energy Buildings) deberán convertirse en un estándar de la construcción en Europa y con el fin de equilibrar el consumo de energía, además de reducirlo al mínimo, los edificios necesariamente deberán ser autoproductores de energía. Por esta razón, la envolvente del edifico y en particular las fachadas son importantes para el logro de estos objetivos y la tecnología fotovoltaica puede tener un papel preponderante en este reto. Para promover el uso de la tecnología fotovoltaica, diferentes programas de investigación internacionales fomentan y apoyan soluciones para favorecer la integración completa de éstos sistemas como elementos arquitectónicos y constructivos, los sistemas BIPV (Building Integrated Photovoltaic), sobre todo considerando el próximo futuro hacia edificios NZEB. Se ha constatado en este estudio que todavía hay una falta de información útil disponible sobre los sistemas BIPV, a pesar de que el mercado ofrece una interesante gama de soluciones, en algunos aspectos comparables a los sistemas tradicionales de construcción. Pero por el momento, la falta estandarización y de una regulación armonizada, además de la falta de información en las hojas de datos técnicos (todavía no comparables con las mismas que están disponibles para los materiales de construcción), hacen difícil evaluar adecuadamente la conveniencia y factibilidad de utilizar los componentes BIPV como parte integrante de la envolvente del edificio. Organizaciones internacionales están trabajando para establecer las normas adecuadas y procedimientos de prueba y ensayo para comprobar la seguridad, viabilidad y fiabilidad estos sistemas. Sin embargo, hoy en día, no hay reglas específicas para la evaluación y caracterización completa de un componente fotovoltaico de integración arquitectónica de acuerdo con el Reglamento Europeo de Productos de la Construcción, CPR 305/2011. Los productos BIPV, como elementos de construcción, deben cumplir con diferentes aspectos prácticos como resistencia mecánica y la estabilidad; integridad estructural; seguridad de utilización; protección contra el clima (lluvia, nieve, viento, granizo), el fuego y el ruido, aspectos que se han convertido en requisitos esenciales, en la perspectiva de obtener productos ambientalmente sostenibles, saludables, eficientes energéticamente y económicamente asequibles. Por lo tanto, el módulo / sistema BIPV se convierte en una parte multifuncional del edificio no sólo para ser física y técnicamente "integrado", además de ser una oportunidad innovadora del diseño. Las normas IEC, de uso común en Europa para certificar módulos fotovoltaicos -IEC 61215 e IEC 61646 cualificación de diseño y homologación del tipo para módulos fotovoltaicos de uso terrestre, respectivamente para módulos fotovoltaicos de silicio cristalino y de lámina delgada- atestan únicamente la potencia del módulo fotovoltaico y dan fe de su fiabilidad por un período de tiempo definido, certificando una disminución de potencia dentro de unos límites. Existe también un estándar, en parte en desarrollo, el IEC 61853 (“Ensayos de rendimiento de módulos fotovoltaicos y evaluación energética") cuyo objetivo es la búsqueda de procedimientos y metodologías de prueba apropiados para calcular el rendimiento energético de los módulos fotovoltaicos en diferentes condiciones climáticas. Sin embargo, no existen ensayos normalizados en las condiciones específicas de la instalación (p. ej. sistemas BIPV de fachada). Eso significa que es imposible conocer las efectivas prestaciones de estos sistemas y las condiciones ambientales que se generan en el interior del edificio. La potencia nominal de pico Wp, de un módulo fotovoltaico identifica la máxima potencia eléctrica que éste puede generar bajo condiciones estándares de medida (STC: irradición 1000 W/m2, 25 °C de temperatura del módulo y distribución espectral, AM 1,5) caracterizando eléctricamente el módulo PV en condiciones específicas con el fin de poder comparar los diferentes módulos y tecnologías. El vatio pico (Wp por su abreviatura en inglés) es la medida de la potencia nominal del módulo PV y no es suficiente para evaluar el comportamiento y producción del panel en términos de vatios hora en las diferentes condiciones de operación, y tampoco permite predecir con convicción la eficiencia y el comportamiento energético de un determinado módulo en condiciones ambientales y de instalación reales. Un adecuado elemento de integración arquitectónica de fachada, por ejemplo, debería tener en cuenta propiedades térmicas y de aislamiento, factores como la transparencia para permitir ganancias solares o un buen control solar si es necesario, aspectos vinculados y dependientes en gran medida de las condiciones climáticas y del nivel de confort requerido en el edificio, lo que implica una necesidad de adaptación a cada contexto específico para obtener el mejor resultado. Sin embargo, la influencia en condiciones reales de operación de las diferentes soluciones fotovoltaicas de integración, en el consumo de energía del edificio no es fácil de evaluar. Los aspectos térmicos del interior del ambiente o de iluminación, al utilizar módulos BIPV semitransparentes por ejemplo, son aún desconocidos. Como se dijo antes, la utilización de componentes de integración arquitectónica fotovoltaicos y el uso de energía renovable ya es un hecho para producir energía limpia, pero también sería importante conocer su posible contribución para mejorar el confort y la salud de los ocupantes del edificio. Aspectos como el confort, la protección o transmisión de luz natural, el aislamiento térmico, el consumo energético o la generación de energía son aspectos que suelen considerarse independientemente, mientras que todos juntos contribuyen, sin embargo, al balance energético global del edificio. Además, la necesidad de dar prioridad a una orientación determinada del edificio, para alcanzar el mayor beneficio de la producción de energía eléctrica o térmica, en el caso de sistemas activos y pasivos, respectivamente, podría hacer estos últimos incompatibles, pero no necesariamente. Se necesita un enfoque holístico que permita arquitectos e ingenieros implementar sistemas tecnológicos que trabajen en sinergia. Se ha planteado por ello un nuevo concepto: "C-BIPV, elemento fotovoltaico consciente integrado", esto significa necesariamente conocer los efectos positivos o negativos (en términos de confort y de energía) en condiciones reales de funcionamiento e instalación. Propósito de la tesis, método y resultados Los sistemas fotovoltaicos integrados en fachada son a menudo soluciones de vidrio fácilmente integrables, ya que por lo general están hechos a medida. Estos componentes BIPV semitransparentes, integrados en el cerramiento proporcionan iluminación natural y también sombra, lo que evita el sobrecalentamiento en los momentos de excesivo calor, aunque como componente estático, asimismo evitan las posibles contribuciones pasivas de ganancias solares en los meses fríos. Además, la temperatura del módulo varía considerablemente en ciertas circunstancias influenciada por la tecnología fotovoltaica instalada, la radiación solar, el sistema de montaje, la tipología de instalación, falta de ventilación, etc. Este factor, puede suponer un aumento adicional de la carga térmica en el edificio, altamente variable y difícil de cuantificar. Se necesitan, en relación con esto, más conocimientos sobre el confort ambiental interior en los edificios que utilizan tecnologías fotovoltaicas integradas, para abrir de ese modo, una nueva perspectiva de la investigación. Con este fin, se ha diseñado, proyectado y construido una instalación de pruebas al aire libre, el BIPV Env-lab "BIPV Test Laboratory", para la caracterización integral de los diferentes módulos semitransparentes BIPV. Se han definido también el método y el protocolo de ensayos de caracterización en el contexto de un edificio y en condiciones climáticas y de funcionamiento reales. Esto ha sido posible una vez evaluado el estado de la técnica y la investigación, los aspectos que influyen en la integración arquitectónica y los diferentes tipos de integración, después de haber examinado los métodos de ensayo para los componentes de construcción y fotovoltaicos, en condiciones de operación utilizadas hasta ahora. El laboratorio de pruebas experimentales, que consiste en dos habitaciones idénticas a escala real, 1:1, ha sido equipado con sensores y todos los sistemas de monitorización gracias a los cuales es posible obtener datos fiables para evaluar las prestaciones térmicas, de iluminación y el rendimiento eléctrico de los módulos fotovoltaicos. Este laboratorio permite el estudio de tres diferentes aspectos que influencian el confort y consumo de energía del edificio: el confort térmico, lumínico, y el rendimiento energético global (demanda/producción de energía) de los módulos BIPV. Conociendo el balance de energía para cada tecnología solar fotovoltaica experimentada, es posible determinar cuál funciona mejor en cada caso específico. Se ha propuesto una metodología teórica para la evaluación de estos parámetros, definidos en esta tesis como índices o indicadores que consideran cuestiones relacionados con el bienestar, la energía y el rendimiento energético global de los componentes BIPV. Esta metodología considera y tiene en cuenta las normas reglamentarias y estándares existentes para cada aspecto, relacionándolos entre sí. Diferentes módulos BIPV de doble vidrio aislante, semitransparentes, representativos de diferentes tecnologías fotovoltaicas (tecnología de silicio monocristalino, m-Si; de capa fina en silicio amorfo unión simple, a-Si y de capa fina en diseleniuro de cobre e indio, CIS) fueron seleccionados para llevar a cabo una serie de pruebas experimentales al objeto de demostrar la validez del método de caracterización propuesto. Como resultado final, se ha desarrollado y generado el Diagrama Caracterización Integral DCI, un sistema gráfico y visual para representar los resultados y gestionar la información, una herramienta operativa útil para la toma de decisiones con respecto a las instalaciones fotovoltaicas. Este diagrama muestra todos los conceptos y parámetros estudiados en relación con los demás y ofrece visualmente toda la información cualitativa y cuantitativa sobre la eficiencia energética de los componentes BIPV, por caracterizarlos de manera integral. ABSTRACT A sustainable design process today is intended to produce high-performance buildings that are energy-efficient, healthy and economically feasible, by wisely using renewable resources to minimize the impact on the environment and to reduce, as much as possible, the energy demand. In the last decade, the reduction of energy needs in buildings has become a top priority. The Directive 2002/91/EC “Energy Performance of Buildings” (and its subsequent updates) established a general regulatory framework’s methodology for calculation of minimum energy requirements. Since then, the aim of fulfilling new directives and protocols has led the energy policies in several countries in a similar direction that is, focusing on the need of increasing energy efficiency in buildings, taking measures to reduce energy consumption, and fostering the use of renewable sources. Zero Energy Buildings or Net Zero Energy Buildings will become a standard in the European building industry and in order to balance energy consumption, buildings, in addition to reduce the end-use consumption should necessarily become selfenergy producers. For this reason, the façade system plays an important role for achieving these energy and environmental goals and Photovoltaic can play a leading role in this challenge. To promote the use of photovoltaic technology in buildings, international research programs encourage and support solutions, which favors the complete integration of photovoltaic devices as an architectural element, the so-called BIPV (Building Integrated Photovoltaic), furthermore facing to next future towards net-zero energy buildings. Therefore, the BIPV module/system becomes a multifunctional building layer, not only physically and functionally “integrated” in the building, but also used as an innovative chance for the building envelope design. It has been found in this study that there is still a lack of useful information about BIPV for architects and designers even though the market is providing more and more interesting solutions, sometimes comparable to the existing traditional building systems. However at the moment, the lack of an harmonized regulation and standardization besides to the non-accuracy in the technical BIPV datasheets (not yet comparable with the same ones available for building materials), makes difficult for a designer to properly evaluate the fesibility of this BIPV components when used as a technological system of the building skin. International organizations are working to establish the most suitable standards and test procedures to check the safety, feasibility and reliability of BIPV systems. Anyway, nowadays, there are no specific rules for a complete characterization and evaluation of a BIPV component according to the European Construction Product Regulation, CPR 305/2011. BIPV products, as building components, must comply with different practical aspects such as mechanical resistance and stability; structural integrity; safety in use; protection against weather (rain, snow, wind, hail); fire and noise: aspects that have become essential requirements in the perspective of more and more environmentally sustainable, healthy, energy efficient and economically affordable products. IEC standards, commonly used in Europe to certify PV modules (IEC 61215 and IEC 61646 respectively crystalline and thin-film ‘Terrestrial PV Modules-Design Qualification and Type Approval’), attest the feasibility and reliability of PV modules for a defined period of time with a limited power decrease. There is also a standard (IEC 61853, ‘Performance Testing and Energy Rating of Terrestrial PV Modules’) still under preparation, whose aim is finding appropriate test procedures and methodologies to calculate the energy yield of PV modules under different climate conditions. Furthermore, the lack of tests in specific conditions of installation (e.g. façade BIPV devices) means that it is difficult knowing the exact effective performance of these systems and the environmental conditions in which the building will operate. The nominal PV power at Standard Test Conditions, STC (1.000 W/m2, 25 °C temperature and AM 1.5) is usually measured in indoor laboratories, and it characterizes the PV module at specific conditions in order to be able to compare different modules and technologies on a first step. The “Watt-peak” is not enough to evaluate the panel performance in terms of Watt-hours of various modules under different operating conditions, and it gives no assurance of being able to predict the energy performance of a certain module at given environmental conditions. A proper BIPV element for façade should take into account thermal and insulation properties, factors as transparency to allow solar gains if possible or a good solar control if necessary, aspects that are linked and high dependent on climate conditions and on the level of comfort to be reached. However, the influence of different façade integrated photovoltaic solutions on the building energy consumption is not easy to assess under real operating conditions. Thermal aspects, indoor temperatures or luminance level that can be expected using building integrated PV (BIPV) modules are not well known. As said before, integrated photovoltaic BIPV components and the use of renewable energy is already a standard for green energy production, but would also be important to know the possible contribution to improve the comfort and health of building occupants. Comfort, light transmission or protection, thermal insulation or thermal/electricity power production are aspects that are usually considered alone, while all together contribute to the building global energy balance. Besides, the need to prioritize a particular building envelope orientation to harvest the most benefit from the electrical or thermal energy production, in the case of active and passive systems respectively might be not compatible, but also not necessary. A holistic approach is needed to enable architects and engineers implementing technological systems working in synergy. A new concept have been suggested: “C-BIPV, conscious integrated BIPV”. BIPV systems have to be “consciously integrated” which means that it is essential to know the positive and negative effects in terms of comfort and energy under real operating conditions. Purpose of the work, method and results The façade-integrated photovoltaic systems are often glass solutions easily integrable, as they usually are custommade. These BIPV semi-transparent components integrated as a window element provides natural lighting and shade that prevents overheating at times of excessive heat, but as static component, likewise avoid the possible solar gains contributions in the cold months. In addition, the temperature of the module varies considerably in certain circumstances influenced by the PV technology installed, solar radiation, mounting system, lack of ventilation, etc. This factor may result in additional heat input in the building highly variable and difficult to quantify. In addition, further insights into the indoor environmental comfort in buildings using integrated photovoltaic technologies are needed to open up thereby, a new research perspective. This research aims to study their behaviour through a series of experiments in order to define the real influence on comfort aspects and on global energy building consumption, as well as, electrical and thermal characteristics of these devices. The final objective was to analyze a whole set of issues that influence the global energy consumption/production in a building using BIPV modules by quantifying the global energy balance and the BIPV system real performances. Other qualitative issues to be studied were comfort aspect (thermal and lighting aspects) and the electrical behaviour of different BIPV technologies for vertical integration, aspects that influence both energy consumption and electricity production. Thus, it will be possible to obtain a comprehensive global characterization of BIPV systems. A specific design of an outdoor test facility, the BIPV Env-lab “BIPV Test Laboratory”, for the integral characterization of different BIPV semi-transparent modules was developed and built. The method and test protocol for the BIPV characterization was also defined in a real building context and weather conditions. This has been possible once assessed the state of the art and research, the aspects that influence the architectural integration and the different possibilities and types of integration for PV and after having examined the test methods for building and photovoltaic components, under operation conditions heretofore used. The test laboratory that consists in two equivalent test rooms (1:1) has a monitoring system in which reliable data of thermal, daylighting and electrical performances can be obtained for the evaluation of PV modules. The experimental set-up facility (testing room) allows studying three different aspects that affect building energy consumption and comfort issues: the thermal indoor comfort, the lighting comfort and the energy performance of BIPV modules tested under real environmental conditions. Knowing the energy balance for each experimented solar technology, it is possible to determine which one performs best. A theoretical methodology has been proposed for evaluating these parameters, as defined in this thesis as indices or indicators, which regard comfort issues, energy and the overall performance of BIPV components. This methodology considers the existing regulatory standards for each aspect, relating them to one another. A set of insulated glass BIPV modules see-through and light-through, representative of different PV technologies (mono-crystalline silicon technology, mc-Si, amorphous silicon thin film single junction, a-Si and copper indium selenide thin film technology CIS) were selected for a series of experimental tests in order to demonstrate the validity of the proposed characterization method. As result, it has been developed and generated the ICD Integral Characterization Diagram, a graphic and visual system to represent the results and manage information, a useful operational tool for decision-making regarding to photovoltaic installations. This diagram shows all concepts and parameters studied in relation to each other and visually provides access to all the results obtained during the experimental phase to make available all the qualitative and quantitative information on the energy performance of the BIPV components by characterizing them in a comprehensive way.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nombre del autor tomado de monograma

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El atrio incorporado en los edificios ha sido un recurso espacial que tempranamente se difundió a nivel global, siendo adoptado por las distintas arquitecturas locales en gran parte del mundo. Su masificación estuvo favorecida primero por la rápida evolución de la tecnología del acero y el vidrio, a partir del siglo XIX, y en segundo termino por el posterior desarrollo del hormigón armado. Otro aspecto que explica tal aceptación en la arquitectura contemporánea, es de orden social y radica en la llamativa cavidad del espacio describiendo grandes dimensiones y favoreciendo con ello, el desarrollo de una multiplicidad de usos en su interior que antes eran impensados. Al interior del atrio, la luz natural es clave en las múltiples vivencias que alberga y sea tal vez la condición ambiental más valorada, ya que entrega una sensación de bienestar al conectarnos visualmente con el ambiente natural. Por esta razón de acuerdo al método hipotético deductivo, se evaluaron los efectos de la configuración geométrica, la cubierta y la orientación en el desempeño de la iluminación natural en la planta baja, a partir un modelo extraído desde el inventario de los edificios atrio construidos en Santiago de Chile, en los últimos 30 años que fue desarrollado en el capitulo 2. El análisis cuantitativo de los edificios inventariados se elaboró en el capítulo 3, considerando las dimensiones de los atrios. Simultáneamente fueron clasificados los aspectos constructivos, los materiales y las características del ambiente interior de cada edificio. En esta etapa además, fueron identificadas las variables de estudio de las proporciones geométricas de la cavidad del atrio con los coeficientes de aspecto de las proporciones, en planta (PAR), en corte (SAR) y de la cavidad según (WI), (AR) y (RI). Del análisis de todos estos parámetros se extrajo el modelo de prueba. El enfoque del estudio del capítulo 4 fue la iluminación natural, se revisaron los conceptos y el comportamiento en el atrio, a partir de un modelo físico construido a escala para registro de la iluminancia bajo cielo soleado de la ciudad. Más adelante se construyó el modelo en ambiente virtual, relacionando las variables determinadas por la geometría de la cavidad y el cerramiento superior; examinándose de esta manera distintas transparencias, proporciones de apertura, en definitiva se evaluó un progresivo cerramiento de las aberturas, verificando el ingreso de la luz y disponibilidad a nivel de piso con la finalidad, de proveer lineamientos útiles en una primera etapa del diseño arquitectónico. Para el análisis de la iluminación natural se revisaron diferentes métodos de cálculo con el propósito de evaluar los niveles de iluminancia en un plano horizontal al interior del atrio. El primero de ellos fue el Factor de Luz Día (FLD) que corresponde, a la proporción de la iluminancia en un punto de evaluación interior respecto, la cantidad proveniente del exterior bajo cielo nublado, a partir de la cual se obtuvo resultados que revelaron la alta luminosidad del cielo nublado de la ciudad. Además fueron evaluadas las recientes métricas dinámicas que dan cuenta, de la cantidad de horas en las cuales de acuerdo a los extensos registros meteorológico de la ciudad, permitieron obtener el porcentajes de horas dentro de las cuales se cumplió el estándar de iluminancia requerido, llamado autonomía lumínica (DA) o mejor aún se permanece dentro de un rango de comodidad visual en el interior del atrio referido a la iluminancia diurna útil (UDI). En el Capítulo 5 se exponen los criterios aplicados al modelo de estudio y cada una de las variantes de análisis, además se profundizó en los antecedentes y procedencia de las fuentes de los registros climáticos utilizados en las simulaciones llevadas a cabo en el programa Daysim operado por Radiance. Que permitieron evaluar el desempeño lumínico y la precisión, de cada uno de los resultados para comprobar la disponibilidad de iluminación natural a través de una matriz. En una etapa posterior se discutieron los resultados, mediante la comparación de los datos logrados según cada una de las metodologías de simulación aplicada. Finalmente se expusieron las conclusiones y futuras lineas de trabajo, las primeras respecto el dominio del atrio de cuatro caras, la incidencia del control de cerramiento de la cubierta y la relación establecida con la altura; indicando en lo específico que las mediciones de iluminancia bajo el cielo soleado de verano, permitieron aclarar, el uso de la herramienta de simulación y método basado en el clima local, que debido a su reciente desarrollo, orienta a futuras líneas de trabajo profundizando en la evaluación dinámica de la iluminancia contrastado con monitorización de casos. ABSTRACT Atriums incorporated into buildings have been a spatial resource that quickly spread throughout the globe, being adopted by several local architecture methods in several places. Their widespread increase was highly favored, in the first place, with the rapid evolution of steel and glass technologies since the nineteen century, and, in second place, by the following development of reinforced concrete. Another issue that explains this success into contemporary architecture is associated with the social approach, and it resides in the impressive cavity that describes vast dimensions, allowing the development of multiple uses in its interior that had never been considered before. Inside the atrium, daylight it is a key element in the many experiences that involves and it is possibly the most relevant environmental factor, since it radiates a feeling of well-being by uniting us visually with the natural environment. It is because of this reason that, following the hypothetical deductive method, the effects in the performance of daylight on the floor plan were evaluated considering the geometric configuration, the deck and orientation factors. This study was based in a model withdrawn from the inventory of atrium buildings that were constructed in Santiago de Chile during the past thirty years, which will be explained later in chapter 2. The quantitative analysis of the inventory of those buildings was elaborated in chapter 3, considering the dimensions of the atriums. Simultaneously, several features such as construction aspects, materials and environmental qualities were identified inside of each building. At this stage, it were identified the variables of the geometric proportions of the atrium’s cavity with the plan aspect ratio of proportions in first plan (PAR), in section (SAR) and cavity according to well index (WI), aspect ratio (AR) and room index (RI). An experimental model was obtained from the analysis of all the mentioned parameters. The main focus of the study developed in chapter 4 is daylight. The atrium’s concept and behavior were analyzed from a physical model built under scale to register the illuminances under clear, sunny sky of the city. Later on, this physical model was built in a virtual environment, connecting the variables determined by the geometry of the cavity and the superior enclosure, allowing the examination of transparencies and opening proportions. To summarize, this stage consisted on evaluating a progressive enclosure of the openings, checking the access of natural light and its availability at the atrium floor, in an effort to provide useful guidelines during the first stage of the architectural design. For the analysis of natural lighting, several calculations methods were used in order to determine the levels of illuminances in a horizontal plane inside of the atrium. The first of these methods is the Daylight Factor (DF), which consists in the proportion of light in an evaluation interior place with the amount of light coming from the outside in a cloudy day. Results determined that the cloudy sky of the city has high levels of luminosity. In addition, the recent dynamic metrics were evaluated which reflects the hours quantity. According to the meteorological records of the city’s climate, the standard of illuminance- a standard measure called Daylight Autonomy (DA) – was met. This is even better when the results stay in the line of visual convenience within the atrium, which is referred to as Useful Daylight Illuminance (UDI). In chapter 5, it was presented the criteria applied to the study model and on each of the variants of the analysis. Moreover, the information of the climate records used for the simulations - carried out in the Daysim program managed by Radiance – are detailed. These simulations allowed the observation of the daylight performance and the accuracy of each of the results to confirm the availability of natural light through a matrix. In a later stage, the results were discussed comparing the collected data in each of the methods of simulation used. Finally, conclusions and further discussion are presented. Overall, the four side atrium’s domain and the effect of the control of the cover’s enclosure. Specifically, the measurements of the daylight under summer’s clear, sunny sky allowing clarifying the use of the simulation tool and the method based on the local climate. This method allows defining new and future lines of work deepening on the dynamic of the light in contrast with the monitoring of the cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La edificación residencial existente en España y en Europa se encuentra abocada a una rehabilitación profunda para cumplir los objetivos marcados en la estrategia europea para el año 2050. Estos, para el sector de la edificación, se proponen una reducción del 90% de emisiones de gases de efecto invernadero (GEI) respecto a niveles del año 1990. Este plan a largo plazo establece hitos intermedios de control, con objetivos parciales para el año 2020 y 2030. El objetivo último es aprovechar el potencial de reducción de demanda energética del sector de la edificación, del cual la edificación residencial supone el 85% en España. Dentro de estos requerimientos, de reducción de demanda energética en la edificación, la ventilación en la edificación residencial se convierte en uno de los retos a resolver por su vinculación directa a la salud y el confort de los ocupantes de la misma, y al mismo tiempo su relación proporcional con la demanda energética que presenta el edificio asociada al acondicionamiento térmico. Gran parte de las pérdidas térmicas de la edificación residencial se producen por el aire de renovación y la infiltración de aire a través de la envolvente. La directiva europea de eficiencia energética de la edificación (EPBD), que establece las directrices necesarias para alcanzar los objetivos de este sector en cuanto a emisiones de CO2 y gases de efecto invernadero (GEI), contempla la ventilación con aire limpio como un requisito fundamental a tener en cuenta de cara a las nuevas construcciones y a la rehabilitación energética de los edificios existentes. El síndrome del edificio enfermo, un conjunto de molestias y síntomas asociados a la baja calidad del aire de edificios no residenciales que surgió a raíz de la crisis del petróleo de 1973, tuvo su origen en una ventilación deficiente y una renovación del aire interior insuficiente de estos edificios, producto del intento de ahorro en la factura energética. Teniendo en cuenta que, de media, pasamos un 58% de nuestro tiempo en las viviendas, es fundamental cuidar la calidad del aire interior y no empeorarla aplicando medidas de “eficiencia energética” con efectos no esperados. Para conseguir esto es fundamental conocer en profundidad cómo se produce la ventilación en la edificación en bloque en España en sus aspectos de calidad del aire interior y demanda energética asociada a la ventilación. El objetivo de esta tesis es establecer una metodología de caracterización y de optimización de las necesidades de ventilación para los espacios residenciales existentes en España que aúne el doble objetivo de garantizar la calidad ambiental y reducir la demanda energética de los mismos. La caracterización del parque edificatorio residencial español en cuanto a ventilación es concluyente: La vivienda en España se distribuye principalmente en tres periodos en los que se encuentran más del 80% del total de las viviendas construidas. El periodo anterior a las normas básicas de la edificación (NBE), de 1960 a 1980, el periodo desde 1980 al año 2005, con el mayor número total de viviendas construidas, guiado por la NTE ISV 75, y el periodo correspondiente a la edificación construida a partir del Código Técnico de la Edificación, en 2006, cuyo documento básico de condiciones de salubridad (DB HS3) es la primera norma de obligado cumplimiento en diseño y dimensionamiento de ventilación residencial en España. La selección de un modelo de bloque de viviendas de referencia, un valor medio y representativo, seleccionado de entre estos periodos, pero con cualidades que se extienden más allá de uno de ellos, nos permite realizar un intensivo análisis comparativo de las condiciones de calidad de aire interior y la demanda energética del mismo, aplicando las distintas configuraciones que presenta la ventilación en viviendas dependiendo del escenario o época constructiva (o normativa) en que esta fuera construida. Este análisis se lleva a cabo apoyándose en un doble enfoque: el modelado numérico de simulaciones y el análisis de datos experimentales, para comprobar y afinar los modelos y observar la situación real de las viviendas en estos dos aspectos. Gracias a las conclusiones del análisis previo, se define una estrategia de optimización de la ventilación basada fundamentalmente en dos medidas: 1) La introducción de un sistema de extracción mecánica y recuperación de calor que permita reducir la demanda energética debida a la renovación del aire y a la vez diluir los contaminantes interiores más eficazmente para mejorar, de esta forma, la calidad del ambiente interior. 2) La racionalización del horario de utilización de estos sistemas, no malgastando la energía en periodos de no ocupación, permitiendo una leve ventilación de fondo, debida a la infiltración, que no incida en pérdidas energéticas cuantiosas. A esta optimización, además de aplicar la metodología de análisis previo, en cuanto a demanda energética y calidad del aire, se aplica una valoración económica integradora y comparativa basada en el reglamento delegado EU244/2012 de coste óptimo (Cost Optimal Methodology). Los resultados principales de esta tesis son: • Un diagnóstico de la calidad del aire interior de la edificación residencial en España y su demanda energética asociada, imprescindible para lograr una rehabilitación energética profunda garantizando la calidad del aire interior. • Un indicador de la relación directa entre calidad de aire y demanda energética, para evaluar la adecuación de los sistemas de ventilación, respecto de las nuevas normativas de eficiencia energética y ventilación. • Una estrategia de optimización, que ofrece una alternativa de intervención, y la aplicación de un método de valoración que permite evaluar la amortización comparada de la instalación de los sistemas. ABSTRACT The housing building stock already built in Spain and Europe faces a deep renovation in the present and near future to accomplish with the objectives agreed in the European strategy for 2050. These objectives, for the building sector, are set in a 90% of Green House Gases (GHG) reduction compared to levels in 1990. This long‐term plan has set milestones to control the correct advance of achievement in 2020 and 2030. The main objective is to take advantage of the great potential to reduce energy demand from the building sector, in which housing represents 85% share in Spain. Among this reduction on building energy demand requirements, ventilation of dwellings becomes one of the challenges to solve as it’s directly connected to the indoor air quality (IAQ) and comfort conditions for the users, as well as proportional to the building energy demand on thermal conditioning. A big share of thermal losses in housing is caused by air renovation and infiltration through the envelope leaks. The European Directive on Building energy performance (EPBD), establishes the roots needed to reach the building sector objectives in terms of CO2 and GHG emissions. This directive sets the ventilation and renovation with clean air of the new and existing buildings as a fundamental requirement. The Sick Building Syndrome (SBS), an aggregation of symptoms and annoys associated to low air quality in non residential buildings, appeared as common after the 1973 oil crisis. It is originated in defective ventilation systems and deficient air renovation rates, as a consequence of trying to lower the energy bill. Accounting that we spend 58% of our time in dwellings, it becomes crucial to look after the indoor air quality and focus in not worsening it by applying “energy efficient” measures, with not expected side effects. To do so, it is primary to research in deep how the ventilation takes place in the housing blocks in Spain, in the aspects related to IAQ and ventilation energy demand. This thesis main objective is to establish a characterization and optimization methodology regarding the ventilation needs for existing housing in Spain, considering the twofold objective of guaranteeing the air quality as reducing the energy demand. The characterization of the existing housing building stock in Spain regarding ventilation is conclusive. More of 80% of the housing stock is distributed in 3 main periods: before the implementation of the firsts regulations on building comfort conditions (Normas Básicas de la Edificación), from 1960 to 1980; the period after the first recommendations on ventilation (NTE ISV 75) for housing were set, around 1980 until 2005 and; the period corresponding to the housing built after the existing mandatory regulation in terms of indoor sanity conditions and ventilation (Spanish Building Code, DB HS3) was set, in 2006. Selecting a representative blueprint of a housing block in Spain, which has medium characteristics not just within the 3 periods mention, but which qualities extent beyond the 3 of them, allows the next step, analyzing. This comparative and intense analyzing phase is focused on the air indoor conditions and the related energy demand, applying different configurations to the ventilation systems according to the different constructive or regulation period in which the building is built. This analysis is also twofold: 1) Numerical modeling with computer simulations and 2) experimental data collection from existing housing in real conditions to check and refine the models to be tested. Thanks to the analyzing phase conclusions, an optimization strategy on the ventilation of the housing stock is set, based on two actions to take: 1) To introduce a mechanical exhaust and intake ventilation system with heat recovery that allows reducing energy demand, as improves the capacity of the system to dilute the pollutant load. This way, the environmental quality is improved. 2) To optimize the schedule of the system use, avoids waste of energy in no occupancy periods, relying ventilation during this time in a light infiltration ventilation, intended not to become large and not causing extra energy losses. Apart from applying the previous analyzing methodology to the optimization strategy, regarding energy demand and air quality, a ROI valorization is performed, based on the cost optimal methodology (delegated regulation EU244/2012). The main results from the thesis are: • To obtain a through diagnose regarding air quality and energy demand for the existing housing stock in Spain, unavoidable to reach a energy deep retrofitting scheme with no air quality worsening. • To obtain a marker to relate air quality and energy demand and evaluate adequateness of ventilation systems, for the new regulations to come. • To establish an optimization strategy to improve both air quality and energy demand, applying a compared valorization methodology to obtain the Return On Investment (ROI).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tit. en antep. : Vida interior de un pecador arrepentido