938 resultados para Implant-supported prosthesis
Resumo:
In cases of total or partial maxillectomies, the prosthetic rehabilitation is an effective alternative to minimize the sequelae left by surgical resection. The present study reports a clinical case of a 52-year-old patient who underwent partial maxillectomy, with upper lip involvement. The oronasal communication, resultant from surgical resection, did not allow the patient to return to her normal social life. Besides, the upper lip partial resection damaged her face's aesthetics. The proposed treatment was the confection of an upper lip prosthesis retained by a palatal obturator. The prosthesis insertion restored the patient's facial aesthetics, contributing not only to function, but also to psychosocial adaptation.
Resumo:
Purpose: The aim of this study was to compare splinting techniques for impression copings of osseointegrated implants with different angulations.Materials and Methods: Replicas (N = 24) of a metal matrix (control) containing two implants at 90 degrees and 65 degrees in relation to the horizontal surface were obtained by using four impression techniques: Technique 1 (T1), direct technique with square copings without union in open trays; Technique 2 (T2), square copings splinted with dental floss and autopolymerizing acrylic resin; Technique 3 (T3), square copings splinted with dental floss and autopolymerizing acrylic resin, sectioned and splinted again with autopolymerizing acrylic resin; Technique 4 (T4), square copings splinted with prefabricated acrylic resin bar. The impression material was polyether. The replicas were individually scanned to capture the images, which were assessed in a graphic computation program. The program allowed the angulation between the bases of the replicas and the reading screws to be measured. The images of the replicas were compared with the matrix image (control), and the differences in angulations from the control image were calculated. The analysis of variance and the Tukey test for comparisons (p < 0.05) were used for statistical analysis.Results: All groups showed significant differences in the implant angulations in comparison with the control group (p < 0.05). Group T1 showed the highest difference (1.019 degrees) followed by groups T2 (0.747 degrees), T3 (0.516 degrees), and T4 (0.325 degrees), which showed the lowest angular alteration compared to the control group. There were significant differences between inclined and straight implants in all the groups, except in group T4.Conclusions: Based on the results, the splinting of pick-up impression copings is indicated for osseointegrated implant impressions. The square copings splinted with a prefabricated acrylic resin bar presented the best results among the pick-up impression techniques evaluated in this study.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Purpose: The purpose of this study was to evaluate the color stability of MDX4-4210 maxillofacial elastomer with opacifier addition submitted to chemical disinfection and accelerated aging.Materials and Methods: Ninety specimens were obtained from Silastic MDX4-4210 silicone. The specimens were divided into three groups (n = 30): Group I: colorless, Group II: barium sulfate opacifier, Group III: titanium dioxide opacifier. Specimens of each group (n = 10) were disinfected with effervescent tablets, neutral soap, or 4% chlorhexidine gluconate. Disinfection was conducted three times a week for 2 months. Afterward, the specimens were submitted to different periods of accelerated aging. Color evaluation was carried out after 60 days (disinfection period) and after 252, 504, and 1008 hours of accelerated aging, using a reflection spectrophotometer. Color alterations were calculated by the CIE L*a*b* system. Data were analyzed by three-way ANOVA and Tukey test (alpha = 0.05).Results: Group II exhibited the lowest color change, whereas Group III the highest (p < 0.05), regardless of the chemical disinfection and accelerated aging periods.Conclusion: Opacifier addition, chemical disinfection, and accelerated aging procedures affected the color stability of the maxillofacial silicone.
Resumo:
The aim of this study was to use two-dimensional finite element method to evaluate the displacement and stress distribution transmitted by a distal extension removable partial denture (DERPD) associated with an implant placed at different inclinations (0, 5, 15, and 30 degrees) in the second molar region of the edentulous mandible ridge. Six hemimandibular models were created: model A, only with the presence of the natural tooth 33; model B, similar to model A, with the presence of a conventional DERPD replacing the missing teeth; model C, similar to the previous model, with a straight implant (0 degrees) in the distal region of the ridge, under the denture base; model D, similar to model C, with the implant angled at 5 degrees in the mesial direction; model E, similar to model C, with the implant angled at 15 degrees in the mesial direction; and model F, similar to ME, with the implant angled at 30 degrees in the mesial direction. The models were created with the use of the AutoCAD 2000 program (Autodesk, Inc, San Rafael, CA) and processed for finite element analysis by the ANSYS 8.0 program (Swanson Analysis Systems, Houston, PA). The force applied was vertical of 50 N on each cusp tip. The results showed that the introduction of the RPD overloaded the supporting structures of the RPD and that the introduction of the implant helped to relieve the stresses of the mucosa alveolar, cortical bone, and trabecular bone. The best stress distribution occurred in model D with the implant angled at 5 degrees. The use of an implant as a support decreased the displacement of alveolar mucosa for all inclinations simulated. The stress distribution transmitted by the DERPD to the supporting structures was improved by the use of straight or slightly inclined implants. According to the displacement analysis and von Mises stress, it could be expected that straight or slightly inclined implants do not represent biomechanical risks to use.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Purpose: This study evaluated the influence of distal extension removable partial denture associated with implant in cases of different bone level of abutment tooth, using 2D finite element analysis.Materials and Methods: Eight hemiarch models were simulated: model A-presenting tooth 33 and distal extension removable partial denture replacing others teeth, using distal rest connection and no bone lost; model B-similar to model A but presenting distal guide plate connection; model C-similar to model A but presenting osseointegrated implant with ERA retention system associated under prosthetic base; model D-similar to model B but presenting osseointegrated implant as described in model C; models E, F, G, and H were similar to models A, B, C, and D but presenting reduced periodontal support around tooth 33. Using ANSYS 9.0 software, the models were loaded vertically with 50 N on each cusp tip. For results, von Mises Stress Maps were plotted.Results: Maximum stress value was encountered in model G (201.023 MPa). Stress distribution was concentrated on implant and retention system. The implant/removable partial denture association decreases stress levels on alveolar mucosa for all models.Conclusions: Use of implant and ERA system decreased stress concentrations on supporting structures in all models. Use of distal guide plate decreased stress levels on abutment tooth and cortical and trabecular bone. Tooth apex of models with reduced periodontal support presented increased stress when using distal rest. (Implant Dent 2011;20:192-201)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The artificial iris is the structure responsible for the dissimulation and aesthetics of ocular prosthesis. The objective of the present study was to evaluate the color stability of artificial iris of microwaveable polymerized ocular prosthesis, as a function of paint type, drying method and accelerated aging. A total of 40 discs of microwaveable polymerized acrylic resin were fabricated, and divided according to the blue paint type ( n = 5): hydrosoluble acrylic, nitrocellulose automotive, hydrosoluble gouache and oil paints. Paints where dried either at natural or at infrared light bulb method. Each specimen was constituted of one disc in colorless acrylic resin and another colored with a basic sclera pigment. Painting was performed in one surface of one of the discs. The specimens were submitted to an artificial aging chamber under ultraviolet light, during 1008 h. A reflective spectrophotometer was used to evaluate color changes. Data were evaluated by 3-way repeated-measures ANOVA and the Tukey HSD test (alpha = 0.05). All paints suffered color alteration. The oil paint presented the highest color resistance to artificial aging regardless of drying method. (C) 2010 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Resumo:
The failure of facial prostheses is caused by limitations in the properties of existing materials, especially flexibility and durability. Therefore, this study evaluated the Shore A hardness of silicone used for fabrication of facial prostheses, Silastic MDX4-4210, according to the influence of storage period, daily disinfection, and 2 types of pigmentation. Thirty specimens were fabricated and divided in 3 groups: colorless, pigmented with makeup, and pigmented with iron oxide. Analysis of results was assessed on a Shore A hardness meter immediately, 6 months, and 1 year after fabrication of specimens, following the guidelines of the American Society for Testing and Materials. The hardness values were statistically analyzed by the Tukey test. The silicone exhibited an increase in hardness with time. However, the hardness was stable from 6 months to 1 year. It was concluded that the silicone is within the values of Shore A hardness reported in the literature, regardless of the storage period, pigmentation, and chemical disinfection.